A method to define a minimum-phase transfer function within the bounded region of phase-gain specifications
Method to define minimum phase transfer function within bounded region of phase gain specifications at several discrete frequencies
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Method to define minimum phase transfer function within bounded region of phase gain specifications at several discrete frequencies
A front-illuminated CCD of relative high quantum efficiency (QE) and high charge transfer efficiency (CTE) utilizes an open-phase region for receiving photons and two-phase gate regions (.phi..sub.1 and .phi..sub.2) for transferring electrons collected in one pixel to the next. The open-phase region is implanted with additional n-type elements (phosphorus) in order to increase the potential of the CCD channel in the open-phase region for collection of electrons and additionally implanted with concentrated and very shallow p-type elements (boron) to pin the surface of the n-channel in the open-phase region to OV, while gate region .phi..sub.1 and .phi..sub.2 are biased to -3.5V and driven to +10V by a two-phase transfer clock. The open pinned-phase (OPP) region thus permits two-phase transfer clocking and optimum reception of photons during the integration periods between transfer clock pulses.
A new DSN RF system is being developed that transmits at X-band and receive at both X-band and S-band. End-to-end tests are planned to measure the phase stability of this system. Equations for the phase transfer functions between the error sources in the system and the X-band and S-band Doppler extractor outputs are derived. This analysis considers both test modes, using a test translator, and actual spacecraft tracking where the spacecraft is at some distance from the DSN station. The results indicate that the proposed end-to-end tests will not accurately reflect the error that occurs during actual spacecraft tracking.
An alternative to having a primary frequency standard on board a spacecraft is to phase lock a simple oscillator on the spacecraft to a microwave tone transimitted from the ground.
An alternative to having a primary frequency standard on board a spacecraft is to phase lock a simple oscillator on the spacecraft to a microwave tone transmitted from the ground. The received tone is transponded and rebroadcast to the ground. The round trip phase is measured, and used to correct for effects on time scales longer than the round trip light travel time. This method is used with the TDRSS relay satellites, and will be used for the Japanese space VLBI mission VSOP. There are several sources of error introduced by this process. The most important error source is a loss of the on board standard for all times that the satellite is out of contact with a ground tracking station. The fractional loss will be greater than 10% for almost any orbit, even with a network of several ground tracking stations, and it will be considerably worse for a low earth orbit. Only a geostationary orbit can eliminate this problem. Another error source is connected to the previous one. Round trip phase tracking can remove, after the fact, link effects during a tracking pass on time scales greater than the round trip light travel time. However, there will be a jump in the spacecraft clock when multiple passes are connected (e.g. when the spacecraft is reacquired after passing out of sight). These jumps will be equal in magnitude (except for a geometrical factor) to the accuracy with which the spacecraft orbit is known. With a GPS receiver and GPS-like beacon on a spacecraft, the orbit can be known to a few cm, giving timing jumps on the order of 100 picoseconds. Even with a geostationary orbit, these jumps would occur any time the link was interrupted due to mechanical or electrical problems.
NASA Special Level POD demonstration tests are typically performed on flat plates of a single material containing fatigue cracks with aspect rations between 0.3 and 0.5. In many cases, the inspectors that pass the demonstration tests use (transfer) the NDE technique to inspect different materials and part geometries and for varying types of flaws. The objective of the task is to investigate several of the factors that may influence the transferability of POD demonstration tests. An existing set of 30 6061-T6 aluminum crack panels will be used to create parts with a square tube and pocket type geometries. These same aluminum crack panels were used in a study of the effect of penetrant sensitivity level on POD. Hence, we should be able to directly compare the POD for flat panels versus larger parts with more complex geometries.
Phase change paint tests of a Rockwell International .00593-scale space shuttle orbiter were conducted in the Langley Research Center's Variable Density Wind Tunnel. The test objectives were to determine the effects of various wing/underbody configurations on the aerodynamic heating rates and boundary layer transition during simulated entry conditions. Several models were constructed. Each varied from the other in either wing cuff radius, airfoil thickness, or wing-fuselage underbody blending. Two ventral fins were glued to the fuselage underside of one model to test the interference heating effects. Simulated Mach 8 entry data were obtained for each configuration at angles of attack ranging from 25 to 40 deg, and a Reynolds number variation of one million to eight million. Elevon, bodyflap, and rudder flare deflections were tested. Oil flow visualization and Schlieren photographs were obtained to aid in reducing the phase change paint data as well as to observe the flow patterns peculiar to each configuration.
Tests were conducted in a hypersonic wind tunnel using various truncated space shuttle orbiter configurations in an attempt to establish the optimum model size for other tests examining body shock-wing leading edge interference effects. The tests were conducted at Mach number 8 using the phase change paint technique. A test description, tabulated data, and tracings of isotherms made from photographs taken during the test are presented.
Explore the source record for details and available documents.
A pumped loop two-phase heat transfer system, operating at a nearly constant temperature throughout, includes a plurality of independently operating grooved capillary heat exchanger plates supplied with working fluid through independent flow modulation valves connected to a liquid supply line, a vapor line for collecting vapor from the heat exchangers, a condenser between the vapor and the liquid lines, and a fluid circulating pump between the condenser and the heat exchangers.
A pumped loop two-phase heat transfer system, operating at a nearly constant temperature throughout, includes several independently operating grooved capillary heat exchanger plates supplied with working fluid through independent flow modulation valves connected to a liquid supply line, a vapor line for collecting vapor from the heat exchangers, a condenser between the vapor and the liquid lines, and a fluid circulating pump between the condenser and the heat exchangers.
Direct numerical simulations of fluid flow, heat transfer, and phase changes are presented. The simulations are made possible by a recently developed finite difference/front tracking method based on the one-field formulation of the governing equations where a single set of conservation equations is written for all the phases involved. The conservation equations are solved on a fixed rectangular grid, but the phase boundaries are kept sharp by tracking them explicitly by a moving grid of lower dimension. The method is discussed and applications to boiling heat transfer and the solidification of drops colliding with a wall are shown.
The Two-phase Heat Transfer International Topical Team consists of researchers and members from various space agencies including ESA, JAXA, CSA, and RSA. This presentation included descriptions various fluid experiments either being conducted by or planned by NASA for the International Space Station in the areas of two-phase flow, flow boiling, capillary flow, and crygenic fluid storage.
An innovative pumped loop concept for 600 K space power system radiators utilizing direct contact heat transfer, which facilitates repeated startup/shutdown of the power system without complex and time-consuming coolant thawing during power startup, is under development. The heat transfer process with melting/freezing of Li in an NaK flow was studied through two-dimensional time-dependent numerical simulations to characterize and predict the Li/NaK radiator performance during startup (thawing) and shutdown (cold-trapping). Effects of system parameters and the criteria for the plugging domain are presented together with temperature distribution patterns in solid Li and subsequent melting surface profile variations in time.
Alkali metal two-phase heat transfer and flow characteristics for a rankine-cycle space power system
Alkali metal two-phase heat transfer for space power systems
Two-phase heat-transfer and fluid-flow characteristics in nucleate boiling of potassium for use in space power systems
Two-phase heat transfer instability for subcooled water flow at zero gravity