Search NASA⌕ Search

SEARCH · Search NASA

Results for “phase two”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Method of Distributions for Two‐Phase Flow in Heterogeneous Porous Media

Abstract Multiscale heterogeneity and insufficient characterization data for a specific subsurface formation of interest render predictions of multi‐phase fluid flow in geologic formations highly uncertain. Quantification of the uncertainty propagation from the geomodel to the fluid‐flow response is typically done within a probabilistic framework. This task is computationally demanding due to, for example, the slow convergence of Monte Carlo simulations (MCS), especially when computing the tails of a distribution that are necessary for risk assessment and decision‐making under uncertainty. The frozen streamlines method (FROST) accelerates probabilistic predictions of immiscible two‐phase fluid flow problems; however, FROST relies on MCS to compute the travel‐time distribution, which is then used to perform the transport (phase saturation) computations. To alleviate this computational bottleneck, we replace MCS with a deterministic equation for the cumulative distribution function (CDF) of travel time. The resulting CDF‐FROST approach yields the CDF of the saturation field without resorting to sampling‐based strategies. Our numerical experiments demonstrate the high accuracy of CDF‐FROST in computing the CDFs of both saturation and travel time. For the same accuracy, it is about 5 and 10 times faster than FROST and MCS, respectively.

Yang, Hyung Jun↗

Flow Loop Study of ECT-Based Volume Fraction Monitoring in Oil–Water Two-Phase Flows

Measurement of phase volume fractions in water-containing multiphase flows is necessary for the optimization of a host of industrial flow processes. Many water-containing multiphase flows can be classified as either water-dispersed or water-continuous mixtures. A recently developed approach based on Hanai’s mixture formula and utilizing electrical capacitance tomography (ECT) sensors have shown good potential for obtaining water volume fraction estimates in two-phase water-containing flows with different water salinity levels. However, the proposed approach was investigated via controlled experiments restricted to static configurations while, in practice, multiphase flows can be dynamic and unpredictable. In this work, we perform a flow loop study of the proposed ECT-based method for volume fraction estimation in oil–water two-phase flows. Here, we evaluate the performance of the proposed method in both water-dispersed and water-continuous flow regimes by employing different types of capacitive sensors in cylindrical arrangements and parallel-plate rectangular arrangements.

02 PETROLEUM↗

Performance Analysis of High-Temperature Heat Pumps with Two-Phase Ejectors

A two-phase ejector recovers the energy in the refrigerant cycles’ throttling process, improving the coefficient of performance (COP) of high-temperature heat pumps (HTHPs). This study investigated the effects of the mixing pressure on the performance of two-phase ejectors and ejector-assisted HTHPs. A 1D theoretical model of a two-phase ejector was built to predict the internal fluid dynamics and evaluate ejector performance. A thermodynamic model of an ejector-assisted HTHP was built to evaluate the COP of HTHPs and the volumetric heating capacity of low-global warming potential refrigerants. The results demonstrate that an optimum mixing pressure in a two-phase ejector provides the best performance of a two-phase ejector and ejector-assisted HTHP. The optimum mixing pressure was slightly lower than the evaporation pressure. At this pressure, the two-phase flow in the ejector was subsonic. For ejector-assisted HTHPs using low–global warming potential refrigerants at a sink temperature of 120°C, temperature lift of 40°C, and subcooling of 10°C, a two-phase ejector has an average ejector efficiency of 0.334, and the COP and volumetric heating capacity were improved by 7.2% and 7.3%, respectively.

Wang, Pengtao↗

Relative permeabilities for two-phase flow through wellbore cement fractures

Multiple fluids are likely to exist in fractures and flow paths associated with leaky wellbores, including liquids (e.g., crude oil) and gases (e.g., gas exsolved from liquid). These fluids occupy and move through different portions of the pore spaces within the fractures depending on many factors, including fluid properties, fracture size, and the amount of the different fluids. Upward leakage of any phase, through the fracture, can contaminate water-bearing formations, create hazardous surface conditions, and compromise the functionality of the wellbore. Early signs of wellbore leaks may be expressed by anomalous pressure behavior at surface monitoring points on cavern storage wells. These pressure anomalies are difficult to interpret, necessitating knowledge of the factors that affect the multiphase flow in fractures and porous media. These parameters are critical to modeling multiphase flow in fractures. This insight can guide further diagnosis and maximize leak remediation. Here, our study focuses on the relationship of the liquid–gas relative permeabilities for representative variable-aperture wellbore cement fracture. To obtain the relative permeability of each phase, two-phase flow tests were conducted where both fluids were flowing simultaneously through a fractured wellbore cement specimen under a range of factors, namely (1) aperture size, (2) capillary numbers, and (3) viscosity ratio. The flow experiments were conducted under a range of confining stresses and flow velocities, using nitrogen gas and silicone oils (of different viscosities) in a specially designed pressure vessel. The sum of gas and oil relative permeabilities were found to be less than one under all conditions, which indicates that the presence of one phase affects the permeability of the other phase, and vice versa. Since the gas phase flow conditions include a significant inertial flow component in addition to viscous flow, the inertial flow coefficients at different saturation states are presented. The factors affecting the relationship between the relative permeabilities are discussed in detail. A new mathematical model for estimating the relative permeability of wellbore cement fracture is presented and experimentally validated.

58 GEOSCIENCES↗

Liquid-phase turbulence measurements in air-water two-phase flows using particle image velocimetry

Liquid-phase turbulence plays a vital role in determining various gas-liquid two-phase flow parameters, such as void fraction distribution, bubble morphology, bubble-bubble interactions, and interfacial area concentration. In this study, a two-phase flow database including both the gas- and liquid-phases measurements was developed focusing on three bubbly flow conditions in an air-water two-phase flow loop with a vertical one-inch diameter circular pipe test section. A particle image velocimetry (PIV) system integrating an optical phase separation method, i.e., the planar laser-induced fluorescence (PLIF) technique using fluorescent particles and optical filtration, was applied to measure the liquid-phase turbulence information, including the time-averaged velocity, Reynolds stress, and turbulent kinetic energy for the liquid phase. The PIV measurements were taken at three ports along the test section at 14.5, 51.5, and 88.5 pipe inner diameters downstream of a bubble injector. In addition, a double-sensor conductivity probe was used to measure radial distributions of the local time-averaged void fraction and gas velocity. The measured liquid-phase turbulence was used to benchmark Sato's turbulence model considering the bubble-induced shear stress for the three tested bubbly flows. The benchmark results showed good agreement between the PIV measurements and model predictions. Lastly, in the two bubbly flows tested that have low void fractions being less than 3%, the effect of the bubble-induced turbulence was found not significant. However, the bubble-induced shear stress becomes important with the increase of the void fraction.

42 ENGINEERING↗

Phase Inversion in a Two-phase, BCC+B2, Refractory High Entropy Alloy

A phenomenon of "phase inversion", presumably the first ever experimental evidence in metallic alloys, is shown in a refractory high entropy alloy (RHEA), Al0.5NbTa0.8Ti1.5V0.2Zr. Phase inversion in crystalline solid systems is driven by the differences in elastic modulus of the two phases. Quenching from a high-temperature single phase field, the RHEA exhibits a co-continuous mixture of a disordered BCC and an ordered B2 phase, that upon isothermal annealing at 600°C develops via spinodal decomposition into a continuous B2 matrix with discrete cuboidal BCC precipitates aligned along the <001> directions. Longer term annealing at 600°C results in the development of necking constrictions along the B2 channels, eventually pinching-off these channels and making the BCC phase continuous with discrete B2 precipitates. This inversion the process can be related to the simultaneous operation of two processes:(i) spheroidization of the initially discrete cuboidal BCC precipitates driven by a reduction in the total interface energy and (ii) an increase in the stiffness of the B2 phase, relative to the BCC phase, due to chemical composition changes during annealing, forcing the B2 regions to become discrete driven by the reduction in the total elastic strain energy.

Soni, Vishal↗

Impact of particle loading and phase coupling on gas–solid flow dynamics: A case study of a two-phase, gas–solid flow in an annular pipe

The present study is devoted to a two-phase, gas–solid flow in an annular pipe (hollow cylinder) at an elevated pressure of 15 bars and moderate Reynolds number of circa 6000. The influence of the particle loading, the interaction between the phases, and turbulence dispersion on the flow dynamics is systematically studied by means of computational fluid dynamics simulations, employing the Ansys FLUENT commercial package. The cases with a particle volumetric fraction of 1.2% are referred to as “high particle loading,” and those with 0.13% are denoted as “low particle loading.” The following cases are investigated: (1) pure gas flow; (2) low particle loading two-phase flow with one-way coupling and with turbulence dispersion; (3) low particle loading two-phase flow with two-way coupling but without turbulence dispersion; (4) low particle loading two-phase flow with two-way coupling and with turbulence dispersion; (5) high particle loading two-phase flow with one-way coupling and with turbulence dispersion; (6) high particle loading two-phase flow with two-way coupling but without turbulence dispersion; and (7) high particle loading two-phase flow with two-way coupling and with turbulence dispersion. Additionally, the boundary layer is found to grow without fluctuations of the turbulent kinetic energy (TKE) for cases 1, 2, and 5. For case 4, the TKE fluctuations have been identified, although they appear to be less substantial than those in cases 6 and 7. The authors attribute the semi-chaotic nature of the TKE fluctuations to the particle loading and two-way coupling. In addition, the onset and development of the flow instability have been observed at a random axial distance in cases 4, 6, and 7. Such instability is also attributed to the two-way coupling with turbulence dispersion in the flow. It is concluded that the particle loading, one-way, or two-way coupling between the phases, and the turbulence dispersion models significantly influence the development of the flow dynamics with the same inlet and boundary conditions. Consequently, it is not a trivial question, which result a user should trust. The present computational results inspire to perform verification as well as experimental validation of the simulations, so the simulation results can subsequently be used with confidence for design analysis.

42 ENGINEERING↗

Experimental and analytical study of the hydrodynamic and single and two-phase convective heat transfer performance of flexible PDMS microchannels with micropillar arrays

Various copper and silicon based thermal management systems are used in the cooling of electronics. However, the rigid nature of these materials along with their high thermal and electrical conductivity pose a difficulty in developing direct contact embedded flexible cooling systems that can offer robust cooling performance. The low density, thermal stability, chemical inertness, and electrical insulation of Polydimethylsiloxane (PDMS) make it an ideal material to develop lightweight direct contact thermal management systems for electronics. Its ease of fabrication with tunable flexibility provides the opportunity to go beyond traditional electronics and develop advanced active and passive thermal management systems for a wide–range of applications in foldable and wearable electronics, liquid cooling garments, microgravity, and electric motors. In this study, a flexible PDMS based microchannel with micropillar arrays, which enhance the thermal performance of the device through capillary-assisted flow, has been developed. The hydrodynamic and convection heat transfer performance of three PDMS wick pillar geometries, ranging from a porosity of 0.8–0.91, are investigated and compared under single-phase and two-phase conditions. Dielectric coolant FC-3283 is employed and permeability measurements are made for mass fluxes ranging from 53 kg/m 2 s to 369 kg/m 2 s. Given its conformability, the device demonstrates a deviation from Darcy’s Law, within the laminar regime, with an increasing permeability with mass flux at the rate of ~0.5–0.8 Darcy/(kg/m 2 s). A semi-analytical model has been developed and reported to quantify the conformability of the device. The heat transfer performance is experimentally evaluated using the same dielectric fluid for mass flux ranging from 105 kg/m 2 s to 420 kg/m 2 s with heat fluxes ranging from 1.5 W/cm 2 to 16 W/cm 2 . Heat transfer coefficients of up to 7000 W/m 2 K are observed, which are comparable to copper and silicon microchannels. The effect of porosity on the single phase thermal performance has been evaluated against the pumping power to provide a basis for thermal management system design. Finally, high-speed imaging is performed to study the two-phase flow characteristics to provide insight into the vapor formation and removal.

42 ENGINEERING↗

Thin hybrid capillary two-phase cooling system

A novel hybrid two-phase cooling system was developed that integrated a mechanically pumped two-phase loop with a capillary-driven two-phase cooling device. The latter cooling mechanism was based on evaporation/boiling from wick structures made by sintering copper particles on the interior surfaces of a copper cold plate. The cold plate provided cooling to two surfaces and each of them included four heaters in series. The novelty of the developed technology was preventing flooding of the evaporator wicks by isolating the evaporation surface from the pumped liquid flow that fed them. This arrangement allowed for a high liquid feed flow rate much greater than would be allowed by a capillary pumped system while maintaining a low thermal resistance at the evaporation surface. Using this approach, the cooling system removed over 850 W with a low pumping power below 1.0 W while using R245fa as the working fluid. The equivalent heat fluxes exceeded 970 W/cm 2 over areas less than 0.12 cm 2 . The measured thermal resistance was as low as 0.09 K-cm 2 /W. The presented thermal management solution enables an increase in the power of high heat flux electronic devices beyond the state-of-the-art.

42 ENGINEERING↗

Three and Two Phase Rotating Field Inductive Couplers for Wireless Power Transfer with One Phase per Layer Windings

Multiphase inductive wireless charging coils have been proposed recently to improve coupler surface power density, reduce component stress and size, and provide near-constant power delivery to charge mobile electric systems. Several aspects for the fundamental characterization of multiphase coils are explored up to six phases including approximate mutual inductance with size and turn variation, induced voltage, and output power estimation. The relative component stress and size of passive components for resonant operation are compared between the multiphase variants. A combination of an experimentally validated 3D electromagnetic finite element analysis (FEA) and power electronic co-simulations are used to validate the estimated quantities approximated with a mixture of analytical equations and an artificial neural network model for mutual inductance. A novel three-phase transmitter, two-phase receiver coil pair is also proposed for electric vehicle charging to reduce the number of connections and compensation complexity on the vehicle-side with improved power output compared to a two-phase configuration.

Lewis, Donovin D. [University of Kentucky]↗

Development of a Comprehensive Two-Phase Flow Database for the Validation of NEK-2P

Three-dimensional (3-D) two-phase Computational Fluid Dynamics (CFD) codes are emerging as a powerful and potentially practical tool for applications in which detailed local flow information is needed. However, two-phase flow models and associated closure relations are not well established for CFD applications, which is partly due to the lack of high-quality validation data. The main objective of this work is to develop a comprehensive database of two-phase flows that can be used to validate two-phase CFD codes such as NEK-2P. In this project, four advanced local measurement systems, including Particle Image Velocimetry and Planar Laser-Induced Fluorescence (PIV-PLIF), high-speed imaging, x-ray densitometry, and multi-sensor conductivity probe are employed to measure the local two-phase flow parameters of both gas and liquid phases. By combining these techniques, the local void fraction, bubble velocity, interfacial area concentration, bubble frequency, liquid velocity, turbulence intensity, etc., in various two-phase flow regimes can be obtained. These local measurement techniques are first used in a 25.4 mm circular pipe test section. Seven air-water two-phase flow conditions spanning the bubbly, slug, churn-turbulent, and annular flow regimes are measured in this facility. The obtained database contains the radial profiles of both gas- and liquid-phase parameters at three axial locations along the test section. The second facility used in this work contains a 30 mm × 10 mm rectangular test section, in which three two-phase flow and two single-phase flow conditions are measured. Two-dimensional distributions of local two-phase flow parameters in the cross-sectional plane are measured in this facility at three axial locations as well. A facility featuring a 3×3 electrically heated rod bundle is also designed and being constructed in this project. This facility is specially designed for optical measurements and is expected to provide high-quality boiling data in the future. Preliminary analyses have been performed for the data taken in the 25.4 mm circular pipe. Both center-peaked and wall-peaked void fraction profiles have been observed in the data depending on the two-phase flow conditions and/or developing lengths. The 1-D drift-flux model was evaluated with the newly obtained datasets, in which both gas- and liquid-phases data were directly measured. The distribution parameter model has been optimized based on a new void-profile classification method proposed in this study. The optimized drift-flux model shows a significant improvement in predicting both gas velocity and void fraction. The measured liquid-phase turbulence was used to benchmark Sato’s turbulence model considering the bubble-induced shear stress for the three tested bubbly flows. The benchmark results showed good agreement between the PIV measurements and model predictions. In the bubbly flows tested that have low void fractions less than 3%, the effect of the bubble-induced turbulence was found not significant. However, the bubble-induced shear stress becomes important with the increase of the void fraction. The Conjugate Heat Transfer (CHT) model was developed and implemented in NEK-2P. This model allows the coupled simulation of the solid domain and two-phase fluid domain, allowing the specification of realistic boundary conditions. The CHT implementation was verified first with non-boiling simulations. The predicted temperatures in the fluid domain were shown to be identical in simulations with or without the CHT model. The CHT model was then validated through simulations of three Becker benchmark CHF tests performed under both Dryout (DO) and Departure from Nucleate Boiling (DNB) conditions. Reasonably good agreement was obtained between calculated wall temperatures and corresponding experimental data.

42 ENGINEERING↗

High flux boiling heat transfer enhancement using triangle shaped vertical walls in two-phase microchannel heat exchangers

Two-phase heat exchangers allow heat loads to be dissipated with lower fluid flow rates without inducing thermal gradients, and high surface area microchannels further reduce the thermal resistance of these heat exchangers. However, there are many practical limits that prevent widespread use of two-phase microchannel heat exchangers. Many authors have looked to address these practical limits by treating the channel floors or creating artificial nucleation sites. Few works look to enhance heat transfer in the walls of channels with hydraulic diameters below 200 μm. This work is aimed at increasing the efficacy of high aspect ratio silicon microchannels that use R134a as the working fluid. The 125 parallel channels are 40 μm wide, 200 μm deep, and 2 mm long and contain a 15 μm wide, 150 μm long restriction at each inlet. The thermal resistance and dryout characteristics of traditional, plain-walled channels are compared to channels with 2 area enhancement patterns each of which increases the area available for heat transfer by 41%. Furthermore, a resistance to dryout is seen in both area-enhanced test sections, and a 15.5% reduction in thermal resistance is shown for the area-enhanced part with a 6 μm triangular pitch. Only a 7.8% performance increase is seen in the test section with a 3 μm pitch. Both area enhancement patterns induce an average 27% increase in pressure drop for all tests. Heat transfer characteristics are solved for using a finite element analysis (FEA) model. By examining heat transfer coefficients and local heat fluxes, it is postulated that the area enhancement reduces heat transfer coefficients and the performance increase is caused by increasing the number of active nucleation sites.

42 ENGINEERING↗

Two-Phase Turbulent Kinetic Energy Budget Computation in Co-Current Taylor Bubble Flow

Simulation of two-phase flows is relevant for reactor design and safety at normal operation or during accident scenarios. Often, the two-phase flow is in a regime in which slugs are formed or where the flow stratifies. Modeling such situations using standard single-phase Reynolds-averaged Navier-Stokes (RANS) turbulence models fails due to an overestimation of the eddy viscosity at the resolved two-phase interface. To solve this, an ad hoc turbulence damping term has been proposed in the literature that reduces the turbulence production locally at a two-phase interface, analogously to turbulence wall functions. However, this approach must be tailored to the specific setting and does not consider physical contributions such as surface tension or flow topology. Therefore, the problem of two-phase interfacial turbulence must be studied more in-depth. In this work, we consider co-current turbulent Taylor bubble flow using high-fidelity numerical simulation. The Basilisk code is used to simulate a Taylor bubble rising in a vertical pipe. By simulating the bubble in a moving frame of reference, we may study the turbulent kinetic energy (TKE) budgets ahead of the bubble, in its wake, and across the interface. The implementation of the TKE budget computation and the underlying averaging techniques are validated for the single-phase region ahead of the Taylor bubble using reference direct numerical simulation data. The analysis of the TKE budgets in the setting of Taylor bubble flow allows for the study of how turbulence behaves due to the presence of a two-phase interface and, in turn, supports the improvement of two-phase RANS models.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗