Search NASA⌕ Search

SEARCH · Search NASA

Results for “phase-sensitive detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Selectivity enhancement in photoacoustic gas analysis via phase-sensitive detection at high modulation frequency

A method for detecting a target fluid in a fluid sample comprising a first fluid and the target fluid using photoacoustic spectroscopy (PAS), comprises a) providing a light source configured to introduce an optical signal having at least one wavelength into the fluid sample; b) modulating the optical signal at a desired modulation frequency such that the optical signal generates an acoustic signal in the fluid sample; c) measuring the acoustic signal in a resonant acoustic detector; and d) using the phase of the acoustic signal to detect the presence of the target fluid.

Kosterev, Anatoliy↗

Polarization-stabilized 1.15- and 3.39-micron He-Ne lasers

Two methods for polarization stabilization of an internal-mirror 3.39-micron He-Ne laser are reported. The first relies on a concurrently lasing 1.15-micron transition by fixing the relative amplitude of two orthogonally polarized longitudinal modes that are split by a Rochon prism and detected with separate Si photodiodes. In the second method, two spatially separated orthogonally polarized adjacent 3.39-micron modes are optically balanced, differentially chopped, and recombined on a single InSb photodiode for phase-sensitive detection. The dual-wavelength scheme has been tested by beating against a methane-stabilized 3.39-micron He-Ne laser, which yields maximum excursions of less than 0.5 MHz over several hours and comparable reproducibility. The polarization-stabilized He-Ne laser has been used as a reference for a tunable color-center laser molecular-beam optothermal spectrometer and provides a precision of better than 2 MHz.

Junttila, M.-L.↗

Solar Activity and its Impact on Earth's Climate

The Sun's activity is now approaching an expected 2006 minimum, following the dramatic maximum of Solar Cycle 23, that included events such as the 2001 "Bastille Day" Coronal Mass Ejection, and the record-setting Oct-Nov 2003 solar flares, with their associated sunspots and variations in Total Solar Irradiance, or TSI. On Nov 4,2003 the largest X-ray flare ever detected (X-28) was observed in detail. We discuss recent satellite measurements of TSI by ACRIM 2 and 3 and Virgo, and new precision observations of TSI and SSI (Solar Spectral Irradiance) from the SORCE mission, that launched on January 25,2003. TSI variations recorded during the June 8,2004 transit of Venus show the unprecedented precision of the SORCE Total Irradiance Monitor (TIM) instrument, the first of its kind to employ phase-sensitive detection. The SORCE spectral instruments, XPS, Solstice, and SIM, record the Sun's changes over a wide range of wavelengths, from 1 to more than 2000 nanometers, for the first time covering the peak of the solar spectrum, including spectral components that provide energy inputs to key components of the climate system - ultraviolet (UV) into the upper atmospheric ozone layer, infrared (IR) into the lower atmosphere and clouds, and Visible into the Oceans and biosphere. Succeeding satellite missions are planned to monitor both TSI and SSI through Cycle 24. We summarize current ideas about decadal and longer solar variability, and associated potential impacts on Earth's climate on time scales from decades to centuries, especially highlighting the role of feedbacks in the climate system.

Cahalan, Robert F.↗

SORCE and Future Satellite Observations of Solar Irradiance

With solar activity just passing the maximum of cycle 23, SORCE is beginning a 5 year mission to measure total solar irradiance (TSI) with unprecedented accuracy using phase-sensitive detection, and to measure spectral solar irradiance (SSI) with unprecedented spectral coverage, from 1 to 2000 nm. The new Total Irradiance Monitor (TIM) has 4 active cavity radiometers, any one of which can be used as a fixed-temperature reference against any other that is exposed to the Sun via a shutter that cycles at a rate designed to minimize noise at the shutter frequency. The new Spectral Irradiance Monitor (SIM) is a dual Fery prism spectrometer that can employ either prism as a monochromatic source on the other prism, thus monitoring its transmission during the mission lifetime. Either prism can measure SSI from 200 to 2000 nm, employing the same phase-sensitive electrical substitution strategy as TIM. SORCE also carries dual SOLSTICE instruments to cover the spectral range 100-320 nm, similar to the instruments onboard UARS, and also an XUV Photometer System (XPS) similar to that on TIMED. SSI has now been added to TSI as a requirement of EOS and NPOESS, because different spectral components drive different components of the climate system - UV into upper atmosphere and stratospheric ozone, IR into tropospheric water vapor and clouds, and Visible into the oceans and biosphere. Succeeding satellite missions being planned for 2006 and 2011 will continue to monitor these critical solar variables.

Cahalan, Robert F.↗

Photolysis of spacecraft contaminants

A molecular beam facility, which was designed to measure photochemical cross-sections, has been constructed at the Athens College science facility. The integration of this vacuum system into an operational photochemical instrument was performed with signal processing consisting of both dc and ac techniques. Of the experiments performed to date on the vacuum ultraviolet photolysis of water vapor, it is apparent that a larger pumping capacity (preferably with differential pumping) is required to improve upon the background signal. Both phase-sensitive detection and ion-counting techniques are recommended for future studies.

Workman, G. L.↗

Vibration-rotation line strengths of the gas-phase OH radical

Absorption line strengths have been measured at 295 K for the first time for four vibration-rotation transitions of the OH radical, using a tunable, infrared diode-laser in conjunction with a molecular modulation spectrometer. A periodically varying OH concentration was created by photolysis, using a sinusoidally modulated 2537-A Hg lamp, of a flowing mixture of O3 and H2O contained within a quartz-walled White cell. The modulated absorption owing to the OH radical was subsequently observed by phase-sensitive detection. The absolute modulation amplitude of the OH number density was obtained by numerical simulation of the complete time-dependent photochemical system. The strongest transition measured was at 3407.607 kaysers, with a strength of 3.3 + or - 1.5 x 10 to the -20th per(cm molecule) sq cm.

Podolske, J.↗

Ultrasonic Phased-Array Characterization for NDE Applications

Southwest Research Institute (SwRI) recently fabricated and delivered the 100-channel Ultrasonic Phased-Array Testbed System (UPATS) for NASA's Langley Research Center. NASA prepared the specifications and provided the funding to develop UPATS in order to provide a tool for the improvement of ultrasonic nondestructive evaluation (NDE) and characterization of materials. UPATS incorporates state-of-the-art phased-array concepts such as beam steering, focusing, apodization, and phase-sensitive detection which make it possible to develop more sophisticated testing methodologies. It also can be used to investigate fundamental ultrasonic propagation and detection phenomena such as refraction, diffraction, scattering, and beam broadening.

Hanley, John J.↗

Improved Speed and Functionality of a 580-GHz Imaging Radar

With this high-resolution imaging radar system, coherent illumination in the 576-to-589-GHz range and phase-sensitive detection are implemented in an all-solid-state design based on Schottky diode sensors and sources. By employing the frequency-modulated, continuous-wave (FMCW) radar technique, centimeter-scale range resolution has been achieved while using fractional bandwidths of less than 3 percent. The high operating frequencies also permit centimeter-scale cross-range resolution at several-meter standoff distances without large apertures. Scanning of a single-pixel transceiver enables targets to be rapidly mapped in three dimensions, so that the technology can be applied to the detection of concealed objects on persons.

Dengler, Robert↗

Ultrasonic nondestructive evaluation of graphite epoxy composite laminates

Quantitative ultrasonic techniques are summarized with applications to the measurement of frequency-dependent attenuation and backscatter and to the NDE of composite laminates. Results are listed for the ultrasonic NDE of graphite-epoxy composite laminates including impact and fatigue damage as well as porosity. The methods reviewed include transmission measurements of attenuation, reconstructive tomography based on attenuation, estimating attenuation from backscattered ultrasound, and backscatter approaches. Phase-sensitive and -insensitive detection techniques are mentioned such as phase cancellation at piezoelectric receiving transducers and acoustoelectric effects. The techniques permit the NDE of the parameters listed in inhomogeneous media and provide both images from the transmission mode and in the reflection mode.

Miller, James G.↗

Optical proximity detector

Sensitive, relatively inexpensive instrument uses phase-detection techniques to sense presence of objects. Phase-sensitive detectors, LED, photodiode with response matched to LED output, and filtering lens allow detector to operate over narrow radiation band, giving selectivity over stray light.

Hermann, W. A.↗

Coherent summation of spatially distorted laser Doppler signals by using a two-dimensional heterodyne detector array

Phase-sensitive coherent summation of individual heterodyne detector array signals was demonstrated for the enhanced detection of spatially distorted laser Doppler returns. With the use of a 2 x 2 heterodyne detector array, the phase and amplitude of a time-varying speckle pattern was detected, and the signal-to-noise ratio of the Doppler shift estimate was shown to be improved by a factor of 2, depending on the extent of spatial coherence loss. These results are shown to agree with a first-order analysis and indicate the advantage of coherent summation for both short-range laser Doppler velocimetry and long-range atmospheric coherent lidar.

Chan, Kin P.↗

Ultrasonic Nondestructive Evaluation Techniques Applied to the Quantitative Characterization of Textile Composite Materials

In this Progress Report, we describe our recent developments of advanced ultrasonic nondestructive evaluation methods applied to the characterization of anisotropic materials. We present images obtained from experimental measurements of ultrasonic diffraction patterns for a thin woven composite in an immersion setup. In addition, we compare apparent signal loss measurements of the thin woven composite for phase-sensitive and phase-insensitive detection methods. All images of diffraction patterns have been included on the accompanying CD-ROM in the Adobe(Trademark) Portable Document Format (PDF). Due to the extensive amount of data, however, hardcopies of only a small representative selection of the images are included within the printed report. This Progress Report presents experimental results that support successful implementation of single element as well as one and two-dimensional ultrasonic array technologies for the inspection of textile composite structures. In our previous reports, we have addressed issues regarding beam profiles of ultrasonic pressure fields transmitted through a water reference path and transmitted through a thin woven composite sample path. Furthermore, we presented experimental results of the effect of a thin woven composite on the magnitude of an insonifying ultrasonic pressure field. In addition to the study of ultrasonic beam profiles, we consider issues relevant to the application of single-element, one-dimensional, and two-dimensional array technologies towards probing the mechanical properties of advanced engineering composites and structures. We provide comparisons between phase-sensitive and phase-insensitive detection methods for determination of textile composite structure parameters. We also compare phase-sensitive and phase-insensitive - - ---- ----- apparent signal loss measurements in an effort to study the phenomenon of phase cancellation at the face of a finite-aperture single-element receiver. Furthermore, in this Progress Report we extend our work on ultrasonic beam profile issues through investigation of the phase fronts of the pressure field. In Section H of this Progress Report we briefly describe the experimental arrangement and methods for data acquisition of the ultrasonic diffraction patterns upon transmission through a thin woven composite. Section III details the analysis of the experimental data followed by the experimental results in Section IV. Finally, a discussion of the observations and conclusions is found in Section V.

Miller, James G.↗

Phase-Insensitive Ultrasonic Testing System

Ultrasonic testing system developed for use in revealing hidden disbonds at rough, inaccessible interfaces between layers of material. Includes array of small piezoelectric transducers, receiving outputs electronically processed individually and combined in such way as to make system phase-insensitive, overcoming limitations imposed by phase-sensitivity. Development of present ultrasonic system and phase-insensitive-array technique which based motivated by need to detect disbonds under conditions of bondline inhibitor, liner, and fuel at ends of segments of solid rocket motor of space shuttle. Here, liner-to-fuel bondline very rough with respect to ultrasonic wavelength.

Madaras, Eric I.↗