Search NASA⌕ Search

SEARCH · Search NASA

Results for “phasor measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Identification of topology changes in power grids using phasor measurements

Phasor measurement units (PMUs) are increasingly important for monitoring the state of an electrical power grid and quickly detecting topology changes caused by events such as lines going down or large loads being dropped. Phasors are complex‐valued measurements of voltage and current at various points of generation and consumption. If a line goes down or a load is removed, power flows change throughout the grid according to known physical laws, and the probability distribution of phasor measurements changes accordingly. This paper develops a method to estimate the current topology of a power grid from phasor measurements and considers the design goal of placing PMUs at strategic points in a distribution system to achieve good sensitivity to single‐line outages. From a vector of phasor measurements, probabilities are computed corresponding to the scenario that all power lines are operational and to alternate scenarios in which each line goes down individually. These probabilities are functions of the joint distributions of phasor measurements under each possible scenario, obtained through Monte Carlo simulations with random load profiles. We use log‐spline densities to estimate marginal distributions of phasor measurements and fold these into a multivariate Gaussian copula to capture important correlations. Sensitivity to outages varies according to which line goes down and where PMUs are placed on the grid. A greedy search algorithm is demonstrated for placing PMUs at locations that provide good sensitivity to single‐line outages. Published 2014. This article is a U.S. Government work and is in the public domain in the USA.

Wiel, Scott Vander↗

Algorithm for Screening Phasor Measurement Unit Data for Power System Events and Categories and Common Characteristics for Events Seen in Phasor Measurement Unit Relative Phase-Angle Differences and Frequency Signals

A network of multiple phasor measurement units (PMU) was created, set up, and maintained at the University of Texas at Austin to obtain actual power system measurements for power system analysis. Power system analysis in this report covers a variety of time ranges, such as short- term analysis for power system disturbances and their effects on power system behavior and long- term power system behavior using modal analysis. The first objective of this report is to screen the PMU data for events. The second objective of the report is to identify and describe common characteristics extracted from power system events as measured by PMUs. The numerical characteristics for each category and how these characteristics are used to create selection rules for the algorithm are also described. Trends in PMU data related to different levels and fluctuations in wind power output are also examined.

17 WIND ENERGY↗

Analytical Identification Method of Generalized Short‐Circuit Ratio Using Phasor Measurement Units

This paper introduces a novel analytical approach for the identification of the admittance matrix and the generalized short-circuit ratio (gSCR) in power systems integrated with renewable energy sources. The proposed method leverages voltage and current measurements from phasor measurement units (PMUs) to construct a least squares objective function, which is then solved using matrix calculus and partial derivatives. Unlike conventional optimization algorithms, this approach provides an analytical solution that substantially reduces data requirements, enabling the efficient and accurate identification of the gSCR with smaller datasets. Additionally, its fixed computational complexity allows for real-time updates as new data are collected, ensuring continuous refinement of the system of equations and enabling rapid, precise gSCR calculations. The method also exhibits strong robustness against measurement noise, making it well-suited for practical applications in dynamic power systems. The combination of reduced data requirements, real-time adaptability, noise robustness and fixed computational load establishes this method as a highly efficient and reliable tool for real-time power system stability analysis. Case studies on an EPRI 36-bus system demonstrate the method's effectiveness, highlighting its accuracy in closely matching true gSCR values, even under diverse disturbances and noisy conditions.

Han, Zelei [Hohai University, Nanjing (China)] (OR↗

Precise synchronization of phasor measurements in electric power systems

Phasors representing positive sequence voltages and currents in a power network are in the most important parameters in several monitoring, control, and protection functions in interconnected electric power networks. Recent advances in computer relaying have led to very efficient and accurate phasor measurement systems. When the phasors to be measured are separated by hundreds of miles, it becomes necessary to synchronize the measurement processes, so that a consistent description of the state of the power system can be established. Global Positioning System (GPS) transmissions offer an ideal source for synchronization of phasor measurements. The concept and implementation of this technique are described. Several uses of synchronized phasor measurements are also described. Among these are improved state estimation algorithms, state estimator enhancements, dynamic state estimates, improved control techniques, and improved protection concepts.

Phadke, Arun G.↗

Performance Evaluation of Phasor Measurement Systems

After two decades of phasor network deployment, phasor measurements are now available at many major substations and power plants. The North American SynchroPhasor Initiative (NASPI), supported by both the US Department of Energy and the North American Electricity Reliability Council (NERC), provides a forum to facilitate the efforts in phasor technology in North America. Phasor applications have been explored and some are in today’s utility practice. IEEE C37.118 Standard is a milestone in standardizing phasor measurements and defining performance requirements. To comply with IEEE C37.118 and to better understand the impact of phasor quality on applications, the NASPI Performance and Standards Task Team (PSTT) initiated and accomplished the development of two important documents to address characterization of PMUs and instrumentation channels, which leverage prior work (esp. in WECC) and international experience. This paper summarizes the accomplished PSTT work and presents the methods for phasor measurement evaluation.

North American SynchroPhasor Initiative (NASPI)↗

Local Power-Voltage Sensitivity and Thevenin Impedance Estimation from Phasor Measurements

This paper describes how to use voltage phasor measurements to produce a sensitivity matrix that describes how real and reactive power injections at a node on a distribution network affect the local voltage magnitude and angle. Rather than estimating the sensitivity directly, the voltage phasor measurements and power commands/measurements are used to estimate the unbalanced, three-phase Thevenin impedance. The Thevenin impedance estimation is conducted using recursive least squares on temporal difference measurements. The Thevenin impedance and voltage phasor measurement are then used to build the local power-voltage sensitivity matrix with the closed form expression for the Jacobian of the power flow manifold. Hardware-in-the-loop simulations with phasor measurement units providing real phasor measurements are used to evaluate the recursive temporal difference Thevenin impedance estimation and Thevenin-based power-voltage sensitivity methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A linear algorithm for minimum Phasor measurement units placement

A Phasor measurement unit (PMU) measures the voltage and current phasors (angle and magnitude) at a bus in a power system. This paper presents a linear algorithm to minimize the number of PMUs to monitor the entire system by modeling the system with topological observation theory. The algorithm is tested by the computation to standard IEEE 14, 18 and 30 bus systems and New England 39 bus system. Results are compared to those of previously implemented topology based formulated algorithms.

Yuan, Xingchen A.↗

Phasor Measurement Units Optimal Placement and Performance Limits for Fault Localization

Here, the performance limits of faults localization are investigated using synchrophasor data. The focus is on a non-trivial operating regime where the number of Phasor Measurement Unit (PMU) sensors available is insufficient to have full observability of the grid state. Proposed analysis uses the Kullback Leibler (KL) divergence between the distributions corresponding to different fault location hypotheses associated with the observation model. This analysis shows that the most likely locations are concentrated in clusters of buses more tightly connected to the actual fault site akin to graph communities. Consequently, a PMU placement strategy is derived that achieves a near-optimal resolution for localizing faults for a given number of sensors. The problem is also analyzed from the perspective of sampling a graph signal, and how the placement of the PMUs i.e. the spatial sampling pattern and the topological characteristic of the grid affect the ability to successfully localize faults. To highlight the superior performance of presented fault localization and placement algorithms, the proposed strategy is applied to a modified IEEE 34, IEEE-123 bus test cases and to data from a real distribution grid. Additionally, the detection of cyber-physical attacks is also examined where PMU data and relevant Supervisory Control and Data Acquisition (SCADA) network traffic information are compared to determine if a network breach has affected the integrity of the system information and/or operations.

42 ENGINEERING↗

Offline Power Systems Applications Enabled by Phasor Measurement Units: Technical Assistance to the Power Sectors of Southeast Asia

This report provides a brief overview of several offline (non-real-time) applications facilitated by high-resolution time-synchronized measurements recorded by phasor measurement units (PMUs). The high reporting rate and time-synchronization of PMU records provide a detailed view of power system dynamics, enabling electric utilities to obtain a better understanding of their systems. In this report, the following applications have been reviewed: Power plant model validation, System model validation, Ringdown oscillation analysis, Frequency response analysis, Postmortem analysis of disturbance events Along with a brief technical background of the applications above, applicable North American Electric Reliability Corporation (NERC) standards have been discussed, and examples of implementation in North American organizations have been provided. Implementing several of the discussed applications may need a preliminary stage of data gathering from multiple entities, and several frameworks and process flows have been formulated by organizations around the world for this purpose. However, the data-gathering stage has not been considered in the scope of the present report.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

GPS Spoofing Mitigation and Timing Risk Analysis in Networked Phasor Measurement Units via Stochastic Reachability

To address phasor measurement unit (PMU) vulnerability to spoofing, we propose the use of a set-valued state estimation technique known as stochastic reachability (SR)-based distributed Kalman filter (DKF) that computes secure global positioning system (GPS) timing across a network of receivers. Utilizing SR, we estimate not only GPS time but also its stochastic reachable set, which is parameterized by probabilistic zonotope (p-Zonotope). While requiring known measurement error bounds in only non-spoofed conditions, we designed a two-tiered approach. We first performed measurement-level spoofing mitigation via deviation of a measurement innovation from its expected p-Zonotope. We then performed state-level timing risk analysis via a determination of the intersection probability of the estimated p-Zonotope with an unsafe set that violates IEEE C37.118.1a-2014 standards. Finally, we validated our SR-DKF algorithm by subjecting it to a simulated receiver network to coordinate signal-level spoofing. We demonstrate improved timing accuracy and successful spoofing mitigation via the use of our SR-DKF algorithm. We also validated the robustness of the estimated timing risk as the number of receivers were varied.

47 OTHER INSTRUMENTATION↗

Binary particle swarm optimisation‐based optimal substation coverage algorithm for phasor measurement unit installations in practical systems

Phasor measurement units (PMUs) play an important role in the wide‐area monitoring and protection of modern power systems. Historically, their deployment was limited by the prohibitive cost of the device itself. Therefore, the objective of the conventional optimal PMU placement problem was to find minimum number of devices, which when carefully placed throughout the network, maximised observability subject to different constraints. Due to improvements in relay technology, digital relays can now serve as both relays and PMUs. Under such circumstances, the substation installations consume the largest portion of the deployment cost, and not the devices themselves. Thus, for minimising cost of synchrophasor deployment, number of substation installations must be minimised. This study uses binary particle swarm optimisation to minimise number of substations in which installations must be performed for making all voltage levels observable, while being subject to various practical constraints. Standard IEEE systems have been used to explain the technique. Finally, a large‐scale network of Dominion Virginia Power is used as the test bed for implementation.

Mishra, Chetan↗

Synchronous Phasor-like Measurements

Phasor measurement units struggle to make acceptable estimates of frequency and rate of change of frequency. The most important cause of the problem is that the quantity being measured is not actually a phasor. The paper substitutes a different equation for the phasor equatin, and obtains its solution by curve-fitting.

Kirkham, Harold↗

Phasor Measurement Unit and Its Application in Modern Power Systems

The introduction of phasor measuring units (PMUs) in power systems significantly improves the possibilities for monitoring and analyzing power system dynamics. Synchronized measurements make it possible to directly measure phase angles between corresponding phasors in different locations within the power system. Improved monitoring and remedial action capabilities allow network operators to utilize the existing power system in a more efficient way. Improved information allows fast and reliable emergency actions, which reduces the need for relatively high transmission margins required by potential power system disturbances. In this chapter, the applications of PMU in modern power systems are presented. Specifically, the topics touched in this chapter include state estimation, voltage and transient stability, oscillation monitoring, event and fault detection, situation awareness, and model validation. A case study using Characteristic Ellipsoid method based on PMU to monitor power system dynamic is presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effects of Phasor Measurement Uncertainty on Power Line Outage Detection

Phasor measurement unit (PMU) technology provides an effective tool to enhance the wide-area monitoring systems (WAMSs) in power grids. Although extensive studies have been conducted to develop several PMU applications in power systems (e.g., state estimation, oscillation detection and control, voltage stability analysis, and line outage detection), the uncertainty aspects of PMUs have not been adequately investigated. This paper focuses on quantifying the impact of PMU uncertainty on power line outage detection and identification, in which a limited number of PMUs installed at a subset of buses are utilized to detect and identify the line outage events. Specifically, the line outage detection problem is formulated as a multi-hypothesis test, and a general Bayesian criterion is used for the detection procedure, in which the PMU uncertainty is analytically characterized. We further apply the minimum detection error criterion for the multi-hypothesis test and derive the expected detection error probability in terms of PMU uncertainty. The framework proposed provides fundamental guidance for quantifying the effects of PMU uncertainty on power line outage detection. Case studies are provided to validate our analysis and show how PMU uncertainty influences power line outage detection.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Event Classification and Identification Based on the Characteristic Ellipsoid of Phasor Measurement

In this paper, a method to classify and identify power system events based on the characteristic ellipsoid of phasor measurement is presented. The decision tree technique is used to perform the event classification and identification. Event types, event locations and clearance times are identified by decision trees based on the indices of the characteristic ellipsoid. A sufficiently large number of transient events were simulated on the New England 10-machine 39-bus system based on different system configurations. Transient simulations taking into account different event types, clearance times and various locations are conducted to simulate phasor measurement. Bus voltage magnitudes and recorded reactive and active power flows are used to build the characteristic ellipsoid. The volume, eccentricity, center and projection of the longest axis in the parameter space coordinates of the characteristic ellipsoids are used to classify and identify events. Results demonstrate that the characteristic ellipsoid and the decision tree are capable to detect the event type, location, and clearance time with very high accuracy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Utilization of optical sensors for phasor measurement units

With the help of GPS signals for synchronization, increasingly ubiquitous phasor measurement units (PMUs) provide power grid operators unprecedented system monitoring and control opportunities. However, the performance of PMUs is limited by the inherent deficiencies in traditional transformers. To address these issues, an optical sensor is used in PMU for signal acquisition to replace the traditional transformers. This is the first time the utilization of an optical sensor in PMUs has ever been reported. The accuracy of frequency, angle, and amplitude are evaluated via experiments. Lastly, the optical sensor based PMU can achieve the accuracy of 9.03 × 10 –4 Hz for frequency, 6.38 × 10 –3 rad for angle and 6.73 × 10 –2 V for amplitude with real power grid signal, demonstrating the practicability of optical sensors in future PMUs.

24 POWER TRANSMISSION AND DISTRIBUTION↗