Search NASA⌕ Search

SEARCH · Search NASA

Results for “photoinjector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Collider-quality electron bunches from an all-optical plasma photoinjector

We present an approach for generating collider-quality electron bunches using a plasma photoinjector. The approach leverages recently developed techniques for the spatiotemporal control of laser pulses to produce a moving ionization front in a nonlinear plasma wave. The moving ionization front generates an electron bunch with a current profile that balances the longitudinal electric field of an electron beam-driven plasma wave, creating a uniform accelerating field across the bunch. Particle-in-cell (PIC) simulations of the ionization stage show the formation of an electron bunch with 220 pC charge and low emittance (ɛ 𝑥 = 171 nm rad, ɛ 𝑦 = 76 nm rad). Quasistatic PIC simulations of the acceleration stage show that the bunch is efficiently accelerated to 24 GeV over 2 m with a final energy spread of less than 1% and emittances of ɛ 𝑥 = 189 nm rad and ɛ 𝑦 = 80 nm rad. This high-quality electron bunch meets the requirements outlined by the Snowmass process for intermediate-energy colliders and compares favorably to the beam quality of proposed and existing accelerator facilities. The results establish the feasibility of plasma photoinjectors for future collider applications making a significant step toward the realization of high-luminosity, compact accelerators for particle physics research.

43 PARTICLE ACCELERATORS↗

Superconducting radio frequency photoinjectors for CW-XFEL

A dependable and consistent electron source is a crucial requirement for the achievement of high-power free electron lasers (FELs). Over the past two decades, it has been demonstrated that photoinjectors based on SRF technology (SRF guns) are suitable for continuous wave (CW) beam generation. SRF guns possess both the high accelerating field gradients of normal conducting RF photoinjectors and the low power dissipation thanks to mature SRF cavity technology, and therefore have the potential to provide the high-brightness, high-current beams required for CW-XFELs. After the demonstration of the first SRF gun in Dresden-Rossendorf, several SRF gun programs based on different approaches have achieved promising progress and even succeeded in routine operation. SRF guns are expected to play an important role in XFEL facilities in the near future. In this paper, we give an overview of design concepts, important parameters and development status of the worldwide SRF gun projects.

47 OTHER INSTRUMENTATION↗

Multiplexed photoinjector optimization for high-repetition-rate free-electron lasers

The multiplexing capabilities of superconducting X-ray free-electron lasers (FELs) have gained much attention in recent years. The demanding requirements for photon properties from multiple undulator lines necessitate more flexible beam manipulation techniques to achieve the goal of “beam on demand”. In this paper, we investigate a multiplexed configuration for the photoinjector of high-repetition-rate FELs that aims to simultaneously provide low-emittance electron beams of different charges. A parallel, multi-objective genetic algorithm is implemented for the photoinjector parameter optimization. The proposed configuration could drastically enhance the flexibility of beam manipulation to improve multiplexing capabilities and realize the full potential of the facility.

47 OTHER INSTRUMENTATION↗

Sub-THz passive detector performance evaluation with RadiaBeam photoinjector

Wakefield accelerators, based on THz and mm-wave structures, promise to reach the highest energies in record small footprints. However, operation at such frequencies is associated with strong generation of dipole modes that can destroy the beams, which requires controlling the electron beam position at the micron scale. The existing conventional techniques for electron beam position monitoring are not applicable for sub-THz structures due to the space constraints. Here, on the other hand, if dipole modes amplitudes can be measured precisely at different planes, one can derive beam position relative to the central axis. For such a technique a reliable and cost-effective sensor capable of operating in high repletion rate regime is required. In this paper we review the experimental evaluation of a passive sensor candidate for such applications using RadiaBeam 4.5 MeV photoinjector.

Accelerator↗

Compensating slice emittance growth in high brightness photoinjectors using sacrificial charge

Achieving maximum electron beam brightness in photoinjectors requires detailed control of the 3D bunch shape and precise tuning of the beam focusing. Even in state-of-the-art designs, slice emittance growth due to nonlinear space charge forces and partial nonlaminarity often remains non-negligible. In this work, we introduce a new means to linearize the transverse slice phase space: a sacrificial portion of the bunch’s own charge distribution, formed into a wavebroken shock front by highly nonlinear space charge forces within the gun, whose downstream purpose is to dynamically linearize the desired bunch core. We show that linearization of an appropriately prepared bunch can be achieved via strongly nonlaminar focusing of the sacrificial shock front, while the inner core focuses laminarly. This leads to a natural spatial separation of the two distributions: a dense core surrounded by a diffuse halo of sacrificial charge that can be collimated. Multiobjective genetic algorithm optimizations of the ultracompact x-ray free electron laser injector employ this concept, and we interpret it with an analytic model that agrees well with the simulations. In simulation, we demonstrate a final bunch charge of 100 pC, peak current ∼ 30 A, and a sacrificial charge of 150 pC (250 pC total emitted from cathode) with normalized emittance growth of < 20 nm rad due to space charge. This implies a maximum achievable brightness approximately an order of magnitude greater than existing free electron laser injector designs. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Design, development and commissioning of a multi-alkali semiconductor photocathode deposition system for the IUAC Delhi light source photoinjector

A fourth-generation light source, called Delhi Light Source (DLS) based on photocathode-based RF gun has been commissioned at Inter-University Accelerator Centre, New Delhi. Presently, the electron beam is being generated from copper photocathode and the beam is being used for scheduled experiments. Soon, the semiconductor photocathode will be used to produce higher beam current. Here, to develop the semiconductor photocathode, a dedicated photocathode deposition facility was developed in collaboration with Brookhaven national Laboratory (BNL) and has been successfully commissioned and becomes operational at IUAC. This deposition facility is an integrated system with the electron gun and is a unique system as it is capable of producing, preserving (without residual gas poisoning) and in-vacuum transfer of the deposited photocathodes from the deposition chamber up to the RF electron gun. The system is designed to operate under ultra-high vacuum (UHV) and is equipped with load-lock chambers, substrate heating assembly, thickness monitoring via a quartz crystal microbalance (QCM), and an in-situ setup for quantum efficiency (QE) measurements. After testing of all the subsystems and a detailed calibration, the first deposition of a cesium telluride (Cs 2 Te) photocathode was successfully performed on a copper (Cu) substrate. This successful commissioning and initial deposition mark a significant step toward the indigenous photocathode development and lays the groundwork for further research into advanced photo emissive materials at IUAC. This paper will discuss the salient features, installation, commissioning, first semiconductor photocathode deposition and its results.

47 OTHER INSTRUMENTATION↗

First conduction cooled photoinjector status

SRF photoguns become a promising candidate to produce highly stable electrons for UEM/UED applications because of the ultrahigh shot-to-shot stability compared to room temperature RF photoguns. SRF technology was prohibitively expensive for industrial use until two recent advancements: Nb3Sn and conduction cooling. SRF gun can provide a CW operation capability while consuming only 2W of RF power which eliminates the need of an expensive high power RF system and saves a facility footprint. Euclid is developing a continuous wave (CW), 1.5-cell, MeV-scale SRF conduction cooled photogun operating at 1.3 GHz. We aim for generation of the first beam in 2024. In this paper, we present the most up-to-date progress including results of the first cool down of the gun-cavity in the newly developed conduction cooled cryomodule and LLRF system development.

43 PARTICLE ACCELERATORS↗

Electron diffraction intensity from single crystal silicon in a photoinjector

A method includes simulating diffraction in a transmission geometry of relativistic electron bunches from a crystallographic structure of a crystal thereby simulating diffraction of the relativistic electron bunches into a plurality of Bragg peaks. The method includes selecting a range of angles between a direction of propagation of the relativistic electron bunches and a normal direction of crystal including an angle at which a diffraction portion is maximized. The method includes sequentially accelerating a plurality of physical electron bunches to relativistic energies toward a physical crystal having the crystallographic structure and diffracting the plurality of physical electron bunches off the physical crystal at different angles and measuring the diffraction portion into the respective Bragg peak at the different angles. The method includes selecting a final angle based on the measured diffraction portion into the respective Bragg peak at the different angles and generating a pulse of light.

Graves, William↗

Quantum efficiency, photoemission energy spectra, and mean transverse energy of ultrananocrystalline diamond photocathode

The quantum efficiency and mean transverse energy of electrons emitted from a cathode determine the quality of beams generated from photoinjectors. The nitrogen-incorporated ultrananocrystalline diamond, (N)UNCD, is a new class of robust semiconductor photocathodes, which has been considered in photoinjectors for high peak current extraction. In this work, we measure the spectral response in quantum efficiency, photoemission energy spectra, and mean transverse energy of the (N)UNCD photocathode using a photoemission electron microscope. The observed quantum efficiency was comparable to that of copper photocathodes. Photoemission spectra showed the evidence of scattering of electrons before emission. This relaxation of electrons due to scattering is also observed in the spectral response of the mean transverse energy. The mean transverse energy is limited to ∼70 meV at the threshold. We attribute this to the physical and chemical roughness of the (N)UNCD photocathode and, hence, smoother films will be required to further reduce the mean transverse energy obtained from the (N)UNCD photocathode.

Kachwala, A. (ORCID:0000000301756478)↗

Implementation of a 1550-nm laser system for beam characterization at the Argonne Wakefield Accelerator

Accurately recording an electron bunch’s longitudinal profile is an important diagnostic for wakefield accelerators employing shaped bunches to increase transformer ratios. Electro-optic sampling of terahertz radiation from the bunch is an attractive approach due to its non-destructive nature. In preparation for future characterization experiments, the Argonne Wakefield Accelerator test facility has recently installed a 1550 nm laser system, including the necessary support systems to synchronize with the photoinjector laser system at 81.25 MHz. We report here on the initial installation and synchronization demonstrations.

Ody, Alexander [Argonne, PHY]↗

Overview and Commissioning Status of the UCLA MITHRA Facility

Presented here are the first results of commissioning of the S-Band hybrid photoinjector and laser systems at the new accelerator and light source facility, MITHRA, at UCLA. The radiation bunker and capabilities of the facility are described with motivation for detailed measurement of beam parameters explained. Following thorough characterization of the photoinjector, a 1.5 m linac is to be installed and experiments up to 30 MeV will begin. These will include experiments in basic plasma physics, space plasma, terahertz production in dielectric structures, and inverse Compton scattering and applications for the X-rays produced.

Williams, Oliver (ORCID:0000000255874982)↗

Characterization of Cs 3 Sb photocathodes at cryogenic temperatures

Here, we report measurements of quantum efficiency (QE) and mean transverse energy (MTE) from Cs 3 Sb photocathodes in a wide range of photon energies at both room and cryogenic temperatures. Our measurements show a strong temperature dependence of MTE even at photon energies well above threshold, indicating the presence of strong inelastic scattering of excited electrons during transport before emission into vacuum. We also demonstrate a cathode cooling method that largely preserves the QE while reducing MTE, allowing us to achieve MTEs as low as 58 meV with 3% QE in green light from Cs 3 Sb photocathodes. Our results are crucial for producing brighter electron beams for various photoinjector applications like ultrafast electron diffraction and microscopy, x-ray free-electron lasers, and particle colliders.

36 MATERIALS SCIENCE↗

X-ray free electron laser linear accelerator without a laser heater

Linear accelerator based X-ray free electron laser (FEL) light sources provide an important tool for scientific discoveries. Most of these light source facilities employ a laser heater to increase the electron beam’s uncorrelated energy spread to suppress microbunching instability through the linear accelerators. In this paper, we first studied the microbunching instability in an X-ray FEL linear accelerator with lower initial peak current (~ 10 A) and moderate final peak currents (1-2 kA). In this regime, the microbunching instability can be substantially mitigated with modest initial uncorrelated energy spread. Here, we then suggested a less expensive method to mitigate the microbunching instability using a section of low beta FODO lattice instead of the laser heater. With the use of the high brightness electron beam from a photoinjector, the intrabeam scattering effect inside the beam through the FODO lattice can generate sufficient uncorrelated energy spread to mitigate the microbunching instability. At last, we demonstrated the feasibility of this method with self-consistent solution of the Fokker–Planck equation through the X-ray FEL linear accelerator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A parallel variable population multi-objective optimizer for accelerator beam dynamics optimization

The simultaneous optimization of multiple objective functions is needed in many particle accelerator applications. In this paper, we present a parallel evolution based multi-objective optimizer that uses a variable population from generation to generation and an external storage to save good solutions. Two heuristic optimization methods, one uses the unified differential evolution and the other uses the real-coded genetic algorithm, are included in the optimizer to generate next generation candidate solutions, and are compared in the test examples. Finally, as an application, we applied this optimizer to the beam dynamics design optimization of a photoinjector and attained the optimal front solutions after 200 generations with the unified differential evolution offspring production scheme.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vector-based feedback of continuous wave radiofrequency compression cavity for ultrafast electron diffraction

The temporal resolution of ultrafast electron diffraction at weakly relativistic beam energies (⁠≲100 keV) suffers from space-charge induced electron pulse broadening. We describe the implementation of a radio frequency (RF) cavity operating in the continuous wave regime to compress high repetition rate electron bunches from a 40.4 kV DC photoinjector for ultrafast electron diffraction applications. Active stabilization of the RF amplitude and phase through a feedback loop based on the demodulated in-phase and quadrature components of the RF signal is demonstrated. This scheme yields 144 ± 19 fs RMS temporal resolution in pump–probe studies.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Theory of photoemission from cathodes with disordered surfaces

Linear-accelerator-based applications like x-ray free electron lasers, ultrafast electron diffraction, electron beam cooling, and energy recovery linacs use photoemission-based cathodes in photoinjectors for electron sources. Most of these photocathodes are typically grown as polycrystalline materials with disordered surfaces. In order to understand the mechanism of photoemission from such cathodes and completely exploit their photoemissive properties, it is important to develop a photoemission formalism that properly describes the subtleties of these cathodes. Here, the Dowell–Schmerge (D–S) model often used to describe the properties of such cathodes gives the correct trends for photoemission properties like the quantum efficiency (QE) and the mean transverse energy (MTE) for metals; however, it is based on several unphysical assumptions. In the present work, we use Spicer’s three-step photoemission formalism to develop a photoemission model that results in the same trends for QE and MTE as the D–S model without the need for any unphysical assumptions and is applicable to defective thin-film semiconductor cathodes along with metal cathodes. As an example, we apply our model to Cs 3 Sb thin films and show that their near-threshold QE and MTE performance is largely explained by the exponentially decaying defect density of states near the valence band maximum.

43 PARTICLE ACCELERATORS↗