Search NASA⌕ Search

SEARCH · Search NASA

Results for “photoluminescence pumping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Photoluminescence and optical transmission of diffusion-pump oils.

The photoluminescence and optical transmission of the four widely used diffusion-pump oils, DC-705, DC-704, Convalex-10, and Convoil-20, were measured. Each of the oils was found to be transparent throughout the visible region, showed some absorption in the near-UV region, and became very opaque below approximately 300 nm. Both Convalex-10 and Convoil-20 turned yellow after exposure to UV light. No such change was noted in DC-705 or DC-704. Photoluminescence was produced in each of the four oils when irradiated with UV light. Both DC-705 and DC-704 had a nearly identical luminescence spectra that peaked at 350 nm. The spectra of Convalex-10 and Convoil-20 were fairly complex, with several peaks in the visible region.

Kroes, R. L.↗

Optically controlled absorption modulator based on state filling of In(x)Ga(1-x)As/GaAs quantum wells

The first demonstration of an optically controlled absorption modulator based on state filling in a periodically doped In(x)Ga(1-x)As/GaAs multiple quantum well structure is reported. Differential absorption of approximately 10,000/cm is observed in the quantum wells of the test structure at saturation pump powers. Photoluminescence and time-resolved modulation measurements confirm the predicted behavior of carrier recombination and give a measure of enhanced carrier lifetime of approximately 1 ms. These initial results show the potential for developing these structures into optically addressed spatial light modulators.

Iannelli, J. M.↗

Raman and Photoluminescence Spectroscopy of Er(3+) Doped Heavy Metal Oxide Glasses

The potential applications of rare-earth ion doped materials include fiber lasers which can be pumped conveniently by infrared semiconductor laser diodes. The host material systems most widely studied are fluoride crystals and glasses because fluorides have low nonradiative relaxation rates due to their lower phonon energies. However, the mechanical strength, chemical durability and temperature stability of the oxide glasses are generally much better than fluoride glasses. The objective of this research was to investigate the optical and spectroscopic properties of Er(3+)-doped lead-germanate and lead-tellurium-germanate glasses. The maximum vibrational energy of lead-tellurium-germanate glasses are in the range of 740-820/cm, intermediate between those of silicate (1150/cm) and fluoride (530/cm) glasses.

Dyer, Keith↗

1.54 micron Emission from Erbium implanted GaN for Photonic Applications

The development of efficient and compact light sources operating at 1.54 micron is of enormous importance for the advancement of new optical communication systems. Erbium (1%) doped fiber amplifiers (EDFA's) or semiconductor lasers are currently being employed as near infrared light sources. Both devices, however, have inherent limitations due to their mode of operation. EDFA's employ an elaborate optical pumping scheme, whereas diode lasers have a strongly temperature dependent lasing wavelength. Novel light emitters based on erbium doped III-V semiconductors could overcome these limitations. Er doped semiconductors combine the convenience of electrical excitation with the excellent luminescence properties of Er(3+) ions. Electrically pumped, compact, and temperature stable optoelectronic devices are envisioned from this new class of luminescent materials. In this paper we discuss the potential of Er doped GaN for optoelectronic applications based on temperature dependent photoluminescence excitation studies.

Thaik, Myo↗

Photorefractive effect in CdMnTe:V Crystal

We present two-wave mixing result obtained with a CdMnTe:V crystal. A photorefractive gain coefficient of 0.20 /cm was observed at 633 nm with the signal-to-pump ratio being of the order of 10(exp -3). This crystal was grown by vertical Bridgman Technique and doped with Vanadium during the growth. The crystal were of good optical quality and showed high resistivity. Room temperature absorption and low temperature photoluminescence studies comparing the band edge and defect center at the doped and undoped CdMnTe crystal will also be discussed.

Pour, K. M.↗

Photoluminescence spectroscopy and the effective mass theory of strained (In,Ga)As/GaAs heterostructures grown on (112)B GaAs substrates

The photoluminescence characteristics of pseudomorphic In(0.19)Ga(0.81)As/GaAs quantum well structures grown on both the conventional (001) and the unconventional (112)B GaAs substrate are investigated. It is found that the emission spectra of the structures grown on the (112)B surface exhibit some spectral characteristics not observed on similar structures grown on the (001) surface. A spectral blue shift of the e yields hh1 transition with increasing optical pump intensity is observed for the quantum wells on the (112) surface. This shift is interpreted to be evidence of a strain-induced piezoelectric field. A second spectral feature located within the band gap of the In(0.19)Ga(0.81)As layer is also observed for the (112) structure; this feature is thought to be an impurity-related emission. The expected transition energies of the quantum well structures are calculated using the effective mass theory based on the 4 x 4 Luttinger valence band Hamiltonian, and related strain Hamiltonian.

Henderson, R. H.↗

Spectroscopic Chemical Analysis Methods and Apparatus

Spectroscopic chemical analysis methods and apparatus are disclosed which employ deep ultraviolet (e.g. in the 200 nm to 300 nm spectral range) electron beam pumped wide bandgap semiconductor lasers, incoherent wide bandgap semiconductor light emitting devices, and hollow cathode metal ion lasers to perform non-contact, non-invasive detection of unknown chemical analytes. These deep ultraviolet sources enable dramatic size, weight and power consumption reductions of chemical analysis instruments. In some embodiments, Raman spectroscopic detection methods and apparatus use ultra-narrow-band angle tuning filters, acousto-optic tuning filters, and temperature tuned filters to enable ultra-miniature analyzers for chemical identification. In some embodiments Raman analysis is conducted along with photoluminescence spectroscopy (i.e. fluorescence and/or phosphorescence spectroscopy) to provide high levels of sensitivity and specificity in the same instrument.

Hug, William F.↗

Spectroscopic Chemical Analysis Methods and Apparatus

Spectroscopic chemical analysis methods and apparatus are disclosed which employ deep ultraviolet (e.g. in the 200 nm to 300 nm spectral range) electron beam pumped wide bandgap semiconductor lasers, incoherent wide bandgap semiconductor light emitting devices, and hollow cathode metal ion lasers to perform non-contact, non-invasive detection of unknown chemical analytes. These deep ultraviolet sources enable dramatic size, weight and power consumption reductions of chemical analysis instruments. In some embodiments, Raman spectroscopic detection methods and apparatus use ultra-narrow-band angle tuning filters, acousto-optic tuning filters, and temperature tuned filters to enable ultra-miniature analyzers for chemical identification. In some embodiments Raman analysis is conducted along with photoluminescence spectroscopy (i.e. fluorescence and/or phosphorescence spectroscopy) to provide high levels of sensitivity and specificity in the same instrument.

Hug, William F.↗

Low-cost DH and quantum well laser array development

The intial results of a program aimed at developing low-cost diode laser arrays for use as solid-state laser pumps are reported. MOCVD is used to demonstrate excellent run-to-run reproducibility in emission wavelength, threshold current density, and quantum efficiency. For this first experimental series, J(th) values of approximately 1310 Amps/sq cm were obtained for broad-area unthinned devices from the growth runs. Differential quantum efficiencies of between 41 percent and 47 percent were measured on the non-facet-coated devices from all four runs. Single quantum well, separate confinement heterostructure lasers fabricated from wafers grown in the same MOCVD reactor exhibited near single-mode emission, with J(th) values of approximately 300 Amps/sq cm. Photoluminescence data confirm quantum well widths of 80 A and 150 A for two different MOCVD growth runs.

Linden, Kurt J.↗

Investigation of the basic physics of high efficiency semiconductor hot carrier solar cell

The main purpose of this research program is to investigate potential semiconductor materials and their multi-band-gap MQW (multiple quantum wells) structures for high efficiency solar cells for aerospace and commercial applications. The absorption and PL (photoluminescence) spectra, the carrier dynamics, and band structures have been investigated for semiconductors of InP, GaP, GaInP, and InGaAsP/InP MQW structures, and for semiconductors of GaAs and AlGaAs by previous measurements. The barrier potential design criteria for achieving maximum energy conversion efficiency, and the resonant tunneling time as a function of barrier width in high efficiency MQW solar cell structures have also been investigated in the first two years. Based on previous carrier dynamics measurements and the time-dependent short circuit current density calculations, an InAs/InGaAs - InGaAs/GaAs - GaAs/AlGaAs MQW solar cell structure with 15 bandgaps has been designed. The absorption and PL spectra in InGaAsP/InP bulk and MQW structures were measured at room temperature and 77 K with different pump wavelength and intensity, to search for resonant states that may affect the solar cell activities. Time-resolved IR absorption for InGaAsP/InP bulk and MQW structures has been measured by femtosecond visible-pump and IR-probe absorption spectroscopy. This, with the absorption and PL measurements, will be helpful to understand the basic physics and device performance in multi-bandgap InAs/InGaAs - InGaAs/InP - InP/InGaP MQW solar cells. In particular, the lifetime of the photoexcited hot electrons is an important parameter for the device operation of InGaAsP/InP MQW solar cells working in the resonant tunneling conditions. Lastly, time evolution of the hot electron relaxation in GaAs has been measured in the temperature range of 4 K through 288 K using femtosecond pump-IR-probe absorption technique. The temperature dependence of the hot electron relaxation time in the X valley has been measured.

Alfano, R. R.↗

Spectroscopic chemical analysis methods and apparatus

Spectroscopic chemical analysis methods and apparatus are disclosed which employ deep ultraviolet (e.g. in the 200 nm to 300 nm spectral range) electron beam pumped wide bandgap semiconductor lasers, incoherent wide bandgap semiconductor light emitting devices, and hollow cathode metal ion lasers to perform non-contact, non-invasive detection of unknown chemical analytes. These deep ultraviolet sources enable dramatic size, weight and power consumption reductions of chemical analysis instruments. Chemical analysis instruments employed in some embodiments include capillary and gel plane electrophoresis, capillary electrochromatography, high performance liquid chromatography, flow cytometry, flow cells for liquids and aerosols, and surface detection instruments. In some embodiments, Raman spectroscopic detection methods and apparatus use ultra-narrow-band angle tuning filters, acousto-optic tuning filters, and temperature tuned filters to enable ultra-miniature analyzers for chemical identification. In some embodiments Raman analysis is conducted along with photoluminescence spectroscopy (i.e. fluorescence and/or phosphorescence spectroscopy) to provide high levels of sensitivity and specificity in the same instrument.

Hug, William F.↗