Search NASA⌕ Search

SEARCH · Search NASA

Results for “photon counting detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Interferometric two-photon-absorption spectroscopy with three entangled photons

In this work, we propose an interferometric pump-probe technique that employs three entangled photons generated by cascaded spontaneous parametric downconversion. A Mach–Zehnder interferometer made of two three-port waveguide arrays is inserted in the optical path. Two independent phases introduced to manipulate the entangled photon state serve as control parameters and can selectively excite matter pathways. Compared to two-photon-absorption of an entangled photon-pair, the three-photon signals are significantly enhanced by frequency-dispersed photon-counting detection.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Photon-Counting Interferometry to Detect Geontropic Space-Time Fluctuations with GQuEST

The gravity from the quantum entanglement of space-time (GQuEST) experiment uses tabletop-scale Michelson laser interferometers to probe for fluctuations in space-time. We present a practicable interferometer design featuring a novel photon-counting readout method that provides unprecedented sensitivity, as it is not subject to the interferometric standard quantum limit. We evaluate the potential of this design to measure space-time fluctuations motivated by recent “geontropic” quantum gravity models. The accelerated accrual of Fisher information offered by the photon-counting readout enables GQuEST to detect the predicted quantum gravity phenomena within measurement times at least 100 times shorter than equivalent conventional interferometers. The GQuEST design, thus, enables a fast and sensitive search for signatures of quantum gravity in a laboratory-scale experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SQuaD: Smart Quantum Detection for Photon Recognition and Dark Count Elimination

Quantum detectors of single photons are an essential component for quantum information processing across computing, communication and networking. Today's quantum detection system, which consists of single photon detectors, timing electronics, control and data processing software, is primarily used for counting the number of single photon detection events. However, it is largely incapable of extracting other rich physical characteristics of the detected photons, such as their wavelengths, polarization states, photon numbers, or temporal waveforms. This work, for the first time, demonstrates a smart quantum detection system, SQuaD, which integrates a field programmable gate array (FPGA) with a neural network model, and is designed to recognize the features of photons and to eliminate detector dark-count. The SQuaD is a fully integrated quantum system with high timing-resolution data acquisition, onboard multi-scale data analysis, intelligent feature recognition and extraction, and feedback-driven system control. Our \name experimentally demonstrates 1) reliable photon counting on par with the state-of-the art commercial systems; 2) high-throughput data processing for each individual detection events; 3) efficient dark count recognition and elimination; 4) up to 100% accurate feature recognition of photon wavelength and polarization. Additionally, we deploy the SQuaD to an atomic (erbium ion) photon emitter source to realize noise-free control and readout of a spin qubit in the telecom band, enabling critical advances in quantum networks and distributed quantum information processing.

Linne, Karl C. [U. Chicago (main)] (ORCID:00090009↗

Towards a Counting Point Detector for Nanosecond Coherent X-ray Science

We present the technical realization of a high-speed hard X-ray single-photon counting-detection scheme based on a commercial avalanche silicon photodiode and high-speed oscilloscope. The development is motivated by the need to perform pulse-resolved photon-correlation and pump-probe studies at synchrotron sources with densely packed pulse patterns that result in high repetition rate pulses on the order of hundreds of MHz. Commissioning experiments are performed at the 1C PAL-KRISS beamline at PLS-II of South Korea operating at a burst mode maximum repetition rate of 500 MHz. In such a high count-rate measurement, detector dead-time can lead to a distortion of counting statistics. We are able to model the counting behavior of our detector under these conditions with a detector dead-time comparable to time between X-ray pulses, implying that nanosecond X-ray photon correlation spectroscopy should be possible at diffraction-limited light sources.

36 MATERIALS SCIENCE↗

Sensitivity and Detection Limit of Spectroscopic-Grade Perovskite CsPbBr 3 Crystal for Hard X-Ray Detection

We report spectroscopic-grade single crystal detectors can register the energies of individual X-ray interactions enabling photon-counting systems with superior resolution over traditional photoconductive X-ray detection systems. Current technical challenges have limited the preparation of perovskite semiconductors for energy-discrimination X-ray photon-counting detection. Here, this work reports the deployment of a spectroscopic-grade CsPbBr 3 Schottky detector under reverse bias for continuum hard X-ray detection in both the photocurrent and spectroscopic schemes. High surface barriers of approximate to ≈ 1 eV are formed by depositing solid bismuth and gold contacts. The spectroscopic response under a hard X-ray source is assessed in resolving the characteristic X-ray peak. The methodology in enhancing X-ray sensitivity by controlling the X-ray energies and flux, and voltage, is described. The X-ray sensitivity varies between a few tens to over 8000 μC Gy air -1 cm -2 . The detectable dose rate of the CsPbBr 3 detectors is as low as 0.02 nGy air s -1 in the energy discrimination configuration. Finally, the unbiased CsPbBr 3 device forms a spontaneous contact potential difference of about 0.7 V enabling high quality of the CsPbBr 3 single crystals to operate in "passive" self-powered X-ray detection mode and the X-ray sensitivity is estimated as 14 μC Gy air -1 cm -2 . The great potential of spectroscopic-grade CsPbBr 3 devices for X-ray photon-counting systems is anticipated in this work.

36 MATERIALS SCIENCE↗

Bennett-Brassard 1984 quantum key distribution using conjugate homodyne detection

Optical homodyne detection has been widely used in continuous-variable (CV) quantum information processing for measuring field quadrature. In this paper we explore the possibility of operating a conjugate homodyne detection system in “photon counting” mode to implement discrete-variable (DV) quantum key distribution (QKD). A conjugate homodyne detection system, which consists of a beam splitter followed by two optical homodyne detectors, can simultaneously measure a pair of conjugate quadratures X and P of the incoming quantum state. In classical electrodynamics, X 2 + P 2 is proportional to the energy (the photon number) of the input light. In quantum optics, X and P do not commute and thus the above photon-number measurement is intrinsically noisy. This implies that a blind application of standard security proofs of QKD could result in pessimistic performance. We overcome this obstacle by taking advantage of two special features of the proposed detection scheme. First, the fundamental detection noise associated with vacuum fluctuations cannot be manipulated by an external adversary. Second, the ability to reconstruct the photon number distribution at the receiver's end can place additional constraints on possible attacks from the adversary. As an example, we study the security of the BB84 QKD using conjugate homodyne detection and evaluate its performance through numerical simulations. This study may open the door to a family of QKD protocols, complementary to the well-established DV-QKD based on single-photon detection and CV-QKD based on coherent detection.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

PhotonIDs: ML-Powered Photon Identification System for Dark Count Elimination

Reliable single photon detection is the foundation for practical quantum communication and networking. However, today's superconducting nanowire single photon detector(SNSPD) inherently fails to distinguish between genuine photon events and dark counts, leading to degraded fidelity in long-distance quantum communication. In this work, we introduce PhotonIDs, a machine learning-powered photon identification system that is the first end-to-end solution for real-time discrimination between photons and dark count based on full SNSPD readout signal waveform analysis. PhotonIDs ~demonstrates: 1) an FPGA-based high-speed data acquisition platform that selectively captures the full waveform of signal only while filtering out the background data in real time; 2) an efficient signal preprocessing pipeline, and a novel pseudo-position metric that is derived from the physical temporal-spatial features of each detected event; 3) a hybrid machine learning model with near 98% accuracy achieved on photon/dark count classification. Additionally, proposed PhotonIDs ~ is evaluated on the dark count elimination performance with two real-world case studies: (1) 20 km quantum link, and (2) Erbium ion-based photon emission system. Our result demonstrates that PhotonIDs ~could improve more than 31.2 times of signal-noise-ratio~(SNR) on dark count elimination. PhotonIDs ~ marks a step forward in noise-resilient quantum communication infrastructure.

Linne, Karl C. [Chicago U.] (ORCID:000900091870358↗

Multifunctional Superconducting Nanowire Quantum Sensors

Superconducting nanowire single-photon detectors (SNSPDs) offer high-quantum-efficiency and low-dark-count-rate single-photon detection. In a growing number of cases, large magnetic fields are being incorporated into quantum microscopes, nanophotonic devices, and sensors for nuclear and high-energy physics that rely on SNSPDs, but superconducting devices generally perform poorly in large magnetic fields. Here, we demonstrate robust performance of amorphous SNSPDs in magnetic fields of up to ±6 T with a negligible dark-count rate and unchanged quantum efficiency at typical bias currents. Critically, we also show that the SNSPD can be used as a magnetometer with a sensitivity of better than 100μT/√Hz and as a thermometer with a sensitivity of 20μK/√Hz at 1 K. Thus, a single-photon detector integrated into a quantum device can be used as a multifunctional quantum sensor capable of describing the temperature and magnetic field on chip simply by varying the bias current to change the operating modality from single-photon detection to thermometry or magnetometry.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Temperature-dependent characterization of large-area superconducting microwire array with single-photon sensitivity in the near-infrared

Superconducting nanowire single photon detectors (SNSPDs) are a leading detector technology for time-resolved single-photon counting from the ultraviolet to the near-infrared regime. The recent advancement in single-photon sensitivity in micrometer-scale superconducting wires opens up promising opportunities to develop large area SNSPDs with applications in low background dark matter detection experiments. Here, we present the first detailed temperature-dependent study of a 4-channel 1×1 mm 2 WSi superconducting microwire single photon detector (SMSPD) array, including the internal detection efficiency, dark count rate, and importantly the coincident dark counts across pixels. The detector shows saturated internal detection efficiency for photon wavelengths ranging from 635 nm to 1650 nm, time jitter of about 160 ps for 1060 nm photons, and a low dark count rate of about 10 -2 Hz. Additionally, the coincidences of dark count rate across pixels are studied for the first time in detail, where we observed an excess of correlated dark counts, which has important implications for low background dark matter experiments. The results presented is the first step towards characterizing and developing SMSPD array systems and associated background for low background dark matter detection experiments.

47 OTHER INSTRUMENTATION↗

Photon temporal-mode readout for inference of neutron star merger remnant gravitational waves

Gravitational waves emitted after neutron star binary coalescences and the information they carry about dense matter are a high-priority target for next-generation detectors. Even though such detectors are expected to observe millions of signals, detectable postmerger emission will remain rare. Here, in this work, we explore postmerger detectability and inference through an alternative detector readout scheme for data dominated by quantum-noise, which is the case above 1 kHz; photon-counting. In such a readout, signals and noise become quantized into discrete distributions corresponding to the detection of single photons measured in a chosen basis of modes. Through simulated data, we demonstrate that photon counting can be efficient even for weak signals. We find ∼1 in 100 signals with a postmerger signal-to-noise ratio of 0.2 can result in a single photon and thus be detected. Furthermore, after 2 ×10 4 signals—equivalent to 10 −2 to 1.5 years of observation—photon counting results in a twofold improvement in the measurement of the radius of a 1.6⁢𝑀 ⊙ neutron star. Constraints can be further tightened if the detector classical noise is reduced. Photon counting offers a promising alternative to traditional homodyne readout techniques for extracting information from low signal-to-noise ratio postmerger signals.

gravitational wave detection↗

Measuring signatures in photon angular spectra to distinguish nonlinear Compton scattering models

The collision of a high-energy electron beam with a laser pulse may be used to study radiation reaction and nonlinear Compton scattering among many other processes in strong-field quantum electrodynamics. Predictions from simulation and theory for these interactions rely on a number of approximations and assumptions that have not been experimentally tested. Here, experimentally measurable signatures are identified that might be able to distinguish between radiation reaction models, i.e., classical or quantum, or between the local constant field and local monochromatic approximations used to calculate the properties of the nonlinear Compton process. These signatures are considered through Monte Carlo simulations of various experimental conditions that are relevant to today's laser facilities. Potential detection schemes for measuring the signatures are proposed. We find that single-photon counting of keV photons to resolve harmonics and scintillator-based detection of MeV photons may allow us to validate nonlinear Compton scattering models and radiation reaction models respectively. This will require electron beams with divergence angles less than 2 mrad and less than 20% energy spread.

Russell, Brandon K↗

Smart quantum statistical imaging beyond the Abbe-Rayleigh criterion

The wave nature of light imposes limits on the resolution of optical imaging systems. For over a century, the Abbe-Rayleigh criterion has been utilized to assess the spatial resolution limits of imaging instruments. Recently, there has been interest in using spatial projective measurements to enhance the resolution of imaging systems. Unfortunately, these schemes require a priori information regarding the coherence properties of “unknown” light beams and impose stringent alignment conditions. Here, we introduce a smart quantum camera for superresolving imaging that exploits the self-learning features of artificial intelligence to identify the statistical fluctuations of unknown mixtures of light sources at each pixel. This is achieved through a universal quantum model that enables the design of artificial neural networks for the identification of photon fluctuations. Our protocol overcomes limitations of existing superresolution schemes based on spatial mode projections, and consequently provides alternative methods for microscopy, remote sensing, and astronomy.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Counting of Hong-Ou-Mandel Bunched Optical Photons Using a Fast Pixel Camera

The uses of a silicon-pixel camera with very good time resolution (∼nanosecond) for detecting multiple, bunched optical photons is explored. We present characteristics of the camera and describe experiments proving its counting capabilities. We use a spontaneous parametric down-conversion source to generate correlated photon pairs, and exploit the Hong-Ou-Mandel (HOM) interference effect in a fiber-coupled beam splitter to bunch the pair onto the same output fiber. It is shown that the time and spatial resolution of the camera enables independent detection of two photons emerging simultaneously from a single spatial mode.

47 OTHER INSTRUMENTATION↗

A novel integrated time-resolved array avalanche photodiode detection system for nuclear resonant scattering measurements

Here, the nuclear resonant scattering (NRS) experiment requires photon-counting detectors with high time resolution, short dead time, large dynamic range, low noise, and large detection area. An 8-channel avalanche photodiode (APD) array detector system with high integrity, flexibility, and reliability has been developed to adapt to the demands of NRS experiments. The detector system mainly consists of four key parts: (i) an array-APD sensor, (ii) 8-channel integrated fast preamplifiers, (iii) the time-to-digital converter readout electronics, and (iv) a data acquisition system and EPICS support software. Remarkably, the system exhibits a time resolution of better than 500 ps and has a sufficiently low noise level, allowing for the lowest detection energy threshold of 4 keV. The performance of the new array-APD system as well as its real application in nuclear forward scattering (NFS) and nuclear resonant inelastic x-ray scattering (NRIXS) experiments was tested in two synchrotron facilities. With the new system, the NFS signal very close to the prompt electronic scattering signal can be extracted. Thanks to the customized EPICS-areaDetector-based control software, NRIXS spectra can be readily measured with time and energy information of the NRIXS signal stored in the raw data, which is promising for developing NRIXS data analysis in the time domain. The array-APD detector can be deployed for nuclear resonant scattering experiments at various synchrotron radiation facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of High Speed Optical and Magnetic Interactions in Superconducting Nanowire Single Photon Detectors

Single-photon detectors are essential tools for quantum photonics. The ideal single photon detector would exhibit a quantum efficiency (QE) of 100% (i.e. no false negatives), zero dark photon counts per second (i.e. no false positives), zero dead time (i.e. the detector is capable of detecting one photon immediately after another), and zero jitter (i.e. the electrical signal produced by the detector perfectly reproduces the timing of the input photon signal). Commercially available avalanche photodiodes (APDs) have generally performed reasonably well for visible wavelengths but they perform poorly at longer wavelengths. For wavelengths spanning the near- ultraviolet (UV) to the mid- infrared (IR), superconducting nanowire single photon detectors (SNSPDs) can exhibit quantum efficiencies exceeding 90% with dark count rates and timing jitter roughly an order of magnitude less than is typically seen in APDs. While SNSPDSs are now commercially available from several small businesses, fundamental questions about the nature of photon interactions with superconducting nanostructures remain.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A novel silicon photomultiplier readout architecture for low-light applications

In this article we describe the photon detection readout electronics for the nEDM@SNS experiment. The chosen "photon counting" architecture, which utilizes high-efficiency silicon photomultipliers (SiPMs) and is appropriate for low-light applications, allows the use of a relatively high SiPM operating voltage. This maximizes photon detection efficiency and minimizes gain/efficiency voltage-dependence while eliminating direct optical cross-talk.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of High-Temperature SiPM Noise

Introduction • Background: Silicon photomultipliers (SiPMs) are compact, low-power, and high-efficiency detectors that are increasingly used in radiation detection applications like medical imaging and nuclear safeguards. The have advantages of PMTs because they are smaller, operate at lower voltages, and offer high photon detection efficiency. • Challenges: SiPMs suffer from increased dark count rate (DCR) and optical crosstalk (OCT), which degrades performance. • Purpose of study: This study compares the Advansid ASD-NUV3S-P-40, Broadcom AFBR-S4K33C0147L, and Onsemi MicroFJ-30035-TSVTR under four different temperatures to compare their performance in harsh environments.

Fritchie, Jacob↗

The working principle of hybrid perovskite gamma-ray photon counter

Gamma-ray spectroscopy that quantifies the gamma-ray energies is a critical technology widely needed in astrophysics, nuclear material detection and medical treatment. The key is to precisely count gamma-ray photons using sensitive detectors. In this paper, we investigate the operational principles of chlorine-doped methylammonium lead tribromide (MAPbBr 3-x Cl x ) perovskite single crystal detectors that can efficiently count gamma-ray photon events with electrical pulses. Specifically, we find the main dark current originates from the thermally activated electron injection from the impurities, and using high work function contacts can block out the dark noise thus allows for efficient pulse collection at higher electrical fields ~500 V/cm. As a result, we observe strong electrical pulses when exposing the detector under radioactive sources emitting gamma-ray photons at various energies. Our results also reveal the fundamental issues that prevent the reliable observation of photo-electric peak. This work suggest pathway towards energy resolved gamma-ray spectroscopy using perovskite crystal detectors.

36 MATERIALS SCIENCE↗