Search NASA⌕ Search

SEARCH · Search NASA

Results for “photon-counting measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Measurement of the light-field amplitude-correlation function through joint photon-count distributions.

When an amplitude-stabilized He-Ne laser beam is scattered by a rotating ground glass with small surface inhomogeneities, the probability density of the instantaneous scattered-wave amplitude is Gaussian. In this paper, we suggest the use of the joint photon-count probability distribution to measure the absolute value of the electric-field amplitude-correlation function for random Gaussian light fields, and report the results of an experiment in which the Gaussian field is produced by scattering a light beam through a rotating ground glass. This procedure offers an alternative to other conventional methods, such as self-beating spectroscopy and irradiance-correlation techniques. The correlation time of the scattered-field amplitude in the present experiment has been measured with an accuracy of approximately 0.8%.

Furcinitti, P.↗

Airborne Laser Polar Nephelometer

A polar nephelometer has been developed at NCAR to measure the angular variation of the intensity of light scattered by air molecules and particles. The system has been designed for airborne measurements using outside air ducted through a 5-cm diameter airflow tube; the sample volume is that which is common to the intersection of a collimated source beam and the detector field of view within the airflow tube. The source is a linearly polarized helium-neon laser beam. The optical system defines a collimated field-of-view (0.5deg half-angle) through a series of diaphragms located behind a I72-mm focal length objective lens. A photomultiplier tube is located immediately behind an aperture in the focal plane of the objective lens. The laser beam is mechanically chopped (on-off) at a rate of 5 Hz; a two-channel pulse counter, synchronized to the laser output, measures the photomultiplier pulse rate with the light beam both on and off. The difference in these measured pulse rates is directly proportional to the intensity of the scattered light from the volume common to the intersection of the laser beam and the detector field-of-view. Measurements can be made at scattering angles from 15deg to 165deg with reference to the direction of propagation of the light beam. Intermediate angles are obtained by selecting the angular increments desired between these extreme angles (any multiple of 0.1deg can be selected for the angular increment; 5deg is used in normal operation). Pulses provided by digital circuits control a stepping motor which sequentially rotates the detector by pre-selected angular increments. The synchronous photon-counting system automatically begins measurement of the scattered-light intensity immediately after the rotation to a new angle has been completed. The instrument has been flown on the NASA Convair 990 airborne laboratory to obtain data on the complex index of refraction of atmospheric aerosols. A particle impaction device is operated simultaneously to collect particles from the same airflow tube used to make the scattered-light measurements. A size distribution function is obtained by analysis of the particles collected by the impaction device. Calculated values of the angular variation of the scattered-light intensity are obtained by applying Mie scattering theory to the observed size distribution function and assuming different values of the complex index of refraction of the particles. The calculated values are then compared with data on the actual variation of the scattered-light intensity obtained with the polar nephelometer. The most probable value of the complex refractive index is that which provides the best fit between the experimental light scattering data and the parameters calculated from the observed size distribution function.

Grams, Gerald W.↗

Flux measurements of CA II H and K emission

A four-channel photon-counting spectrophotometer (designated HKP-2) is described which is designed for measuring stellar chromospheric calcium emission. The HKP-2 is calibrated, and its performance and accuracy evaluated, by observing 63 of Wilson's (1968) program stars on the same nights with both the HKP-2 and a coude scanner designated HKP-1. The results of the observations are discussed in terms of the calibration of mean H-K flux indices, variations in individual stellar fluxes, the flux ratio for H and K, and the instrument color index. It is shown that the HKP-2 provides satisfactory performance in the measurement of stellar chromospheric emission in a manner closely analogous to the method of Wilson and that a single observation yields a color index as well as flux indices for H and K that can be calibrated and transferred unambiguously to Wilson's system of measurement.

Vaughan, A. H.↗

The High Spectral Resolution Lidar

The High Spectral Resolution Lidar (HSRL) system was developed for the remote measurement of atmospheric optical properties. Measurements are obtained by the separation of the backscattered signal into aerosol and molecular channels using a high spectral resolution Fabry-Perot optical interferometer to separate the aerosol contributions to backscatter near the laser wavelength from the Doppler-shifted molecular component of the backscatter. The transmitter consists of an optically pumped pulsed dye laser of the oscillator-amplifier design which emits at 467.88 nm, with a bandwidth of less than 0.3 pm. The transmitter and receiver share a common Schmidt-Cassegrain telescope, although they do not share the same field stop, but rather two conjugate stops. The HSRL system uses a computer-controlled dual-channel photon-counting data acquisition system providing for stable measurements at very low power levels and an excellent dynamic range. The system has been used to obtain airborne measurements of height profiles of aerosol and molecular backscatter cross sections.

Eloranta, E. W.↗

An evaluation of an ICCD imager of dynamic range expansion technique and application of insitu procedures for life-time extension

Research toward practical implementation of the Intensified Charge Coupled Device (ICCD) as a photon-counting array detector for astronomy is reported. The first area of concentration was to determine the rate and extent of the lifetime limiting damage to the CCD caused by the impact of high energy electrons, and to find whether various methods of annealing the damage were productive. The second effort was to determine the performance of the ICCD in a photon-counting mode to produce extended dynamic range measurements. There are two main effects that appear as the practical results of the electron damage to the CCD. One is an increase in the leakage current, i.e., the normal thermal generation of charge carriers in the silicon that provides a background dark signal that adds to the light produced image. In an undamaged CCD, the leakage current is usually fairly uniform across the photosensitive area of the silicon chip, with the exception of various bright pixels which have an anomalous leakage current well above the overall level.

Currie, D. G.↗

Evaluation of some wide dynamic range readout systems for photoelectric integrating spectrometers

Five types of electronic circuits commonly used for readout of currents from photomultiplier tubes were evaluated. This evaluation was conducted to define the experimental limits of achieving the widest possible dynamic range of light detection and concentration measurements in spectrochemical analysis. The circuits evaluated included the photon-counting technique and four dc circuits. These circuits displayed a dynamic range from 3 to about 4.5 decades within a repeatability criterion of 1 percent, or better. The maximum dynamic range allowed by the photomultiplier tube in this application was estimated to be about 6 decades.

Franklin, M. L.↗

Scientific applications of frequency-stabilized laser technology in space

A synoptic investigation of the uses of frequency-stabilized lasers for scientific applications in space is presented. It begins by summarizing properties of lasers, characterizing their frequency stability, and describing limitations and techniques to achieve certain levels of frequency stability. Limits to precision set by laser frequency stability for various kinds of measurements are investigated and compared with other sources of error. These other sources include photon-counting statistics, scattered laser light, fluctuations in laser power, and intensity distribution across the beam, propagation effects, mechanical and thermal noise, and radiation pressure. Methods are explored to improve the sensitivity of laser-based interferometric and range-rate measurements. Several specific types of science experiments that rely on highly precise measurements made with lasers are analyzed, and anticipated errors and overall performance are discussed. Qualitative descriptions are given of a number of other possible science applications involving frequency-stabilized lasers and related laser technology in space. These applications will warrant more careful analysis as technology develops.

Schumaker, Bonny L.↗

Coding for optical channels with photon-counting

The problem of coding for Pierce's recent model for optical communications is studied. It was concluded that for any positive rate rho (measured in nats per photon), the best code of length n has an error probability bounded by an exponentially decaying function of n. Explicit practical schemes are shown for rho less than or = to 1; and evidence is given that rho approximating 1 may be the practical limit for optical communication.

Mceliece, R. J.↗

Delay-Line Anode For Microchannel-Plate Spectrometer

Photon-counting read-out system for microchannel-plate spectrometer includes delay line and timing circuit to measure wavelength coordinate and wedge/wedge charge-division system to measure orthogonal spatial coordinate. System proves advantageous for portable two-dimensional spectrometers having large image planes and for which design requirements include simplicity, reliability, low power consumption, and low mass.

Lampton, M.↗

Coding for the photon channel

Motivated by a recent paper of Pierce, we consider the problem associated with coding for optical communications systems that use photon-counting techniques. Making certain realistic assumptions, we find that external noise sources are negligible, and that channel capacity (measured in nats per photon) is infinite. However, quantum effects made the design of an efficient system at rates above about 5 nats per photon very difficult.

Mceliece, R. J.↗

A cooled avalanche photodiode with high photon detection probability

An avalanche photodiode has been operated as a photon-counting detector with 2 to 3 times the sensitivity of currently-available photomultiplier tubes. APD (avalanche photodiodes) detection probabilities that exceed 27% and approach 50% have been measured at an optimum operating temperature which minimizes noise. The sources of noise and their dependence on operating temperature and bias voltage are discussed.

Robinson, D. L.↗

ORFEUS focal plane instrumentation: The Berkeley spectrometer

A spectrograph for the ORFEUS mission that incorporates four varied line-space, spherically figured diffraction gratings was designed. The ORFEUS, a 1-m normal incidence telescope is equipped with 2 focal plane spectrographs. The Berkeley spectrograph was developed with an optimizing raytracing computer code. Each grating accepts the light from 20 percent of the aperture of the telescope primary mirror and has a unique set of characteristics to cover a sub-bandpass within the 390 to 1200 A spectral range. Two photon-counting detectors incorporating a time delay readout system are used to record the spectra from all four gratings simultaneously. The nominal design achieves a spectral resolution (FWHM) in excess of 5500 at all wavelengths within the bandpass. The resolution is limited primarily by the detector spatial resolution. The 1 sigma astigmatism of this design varies between 13 and 150 micrometer on the same focal surface. An independent, direct imaging system tracks the drift of the target within the spectrometer aperture and allows measurement of the misalignment between the telescope optical axis and that of the external star tracker. The resolution and astigmatism achievable with this design are superior to those of a standard Rowland spectrograph designed with the same constraints.

Hurwitz, Mark↗

Signal-to-noise ratios in IUE SWP-LO spectra of chromospheric emission-line sources

The short-wavelength-prime (SWP) detector of the International Ultraviolet Explorer should operate near the photon-counting limit, but the noise levels in flat-field images are several times higher. The exaggerated noise can be traced to the incomplete removal of the pixel-to-pixel granularity of the television frames by the prevailing spectral image processing system. An empirical noise model for the current-epoch photometric linearization strategy and one for a hypothetical processing system that achieves complete flat fielding of the raw images are derived. A formula is then proposed to predict the signal-to-noise ratio in the measured flux of an emission line (possibly superimposed on a smooth continuum) in an IUE low-dispersion (5 A resolution) far-ultraviolet (1150 A-1950 A) spectrum as recorded with the SWP camera. For illustration, the formula is specialized to the important C IV 1549 A feature of F-K stars. The S/N relation permits one to determine sensitivity limits, upper limits in faint exposures, and optimum exposure times.

Ayres, Thomas R.↗

The application of laser Rayleigh scattering to gas density measurements in hypersonic helium flows

Measurements of the mean static free-stream gas density have been made in two Langley Research Center helium facilities, the 3-inch leg of the high-Reynolds-number helium complex and the 22-inch hypersonic helium tunnel. Rayleigh scattering of a CW argon ion laser beam at 514.5 nm provided the basic physical mechanism. The behavior of the scattered signal was linear, confirmed by a preliminary laboratory study. That study also revealed the need to introduce baffles to reduce stray light. A relatively simple optical system and associated photon-counting electronics were utilized to obtain data for densities from 10 to the 23rd to 10 to the 25th per cu m. The major purpose, to confirm the applicability of this technique in the hypersonic helium flow, was accomplished.

Hoppe, J. C.↗

The multichannel astrometric photometer and atmospheric limitations in the measurement of relative positions

The operational Multichannel Astrometric Photometer (MAP) now in use in the Allegheny Observatory astrometric program is the culmination of a decade of design and development effort. A detailed description of the system and its related software is followed by analysis of data acquired in four stellar regions. The study indicates an accuracy (in the sense of conformity to the best model), per night, for stars of the eighth magnitude or brighter, of 0.003 arcsec or better. These data points each have approximately twice the precision of the annual normal points obtained in our photographic program. Accuracy is shown to depend on: (1) the photon-count rate of the target star (it follows that the number of photons from the reference frame is also in important factor), (2) the duration of the observation, (3) the angular size of the reference frame, and (4) the quality of the astronomical seeing. Since (4) and, to a lesser extent, (1) involve the atmospheric characteristics at the time of observation, the probable performance at more favorable sites is discussed briefly.

Gatewood, George D.↗

Image plane detector for the dynamics explorer Fabry-Perot interferometer

A compact twelve-channel photon-counting device based on existing Generation II imaging technology has been developed for use as the image-plane detector of the Dynamics Explorer Fabry-Perot interferometer. The device has an S-20 photocathode, three-microchannel plate electron multiplication stages, and an equal-area concentric-ring segmented anode whose geometry mimics that of the interference ring pattern produced by a plane etalon. The twelve channels sample equal and contiguous intervals in the spectrum. The purpose of the delopment has been to utilize the signal multiplex advantage of a multichannel detector in the measurement of Doppler shifts and line-broadening effects for naturally occurring atmospheric emission features of low intensity. The design, testing, calibration, and flight performance of the novel detector system are presented. In addition, measured emission line profiles at high resolution from the satellite instrument are presented to illustrate the operation of the device.

Killeen, T. L.↗

Charge coupled devices

The results are presented of a program to design, fabricate, and test CCD arrays suitable for operation in an electron-bombarded mode. These intensified charge coupled devices have potential application to astronomy as photon-counting arrays. The objectives of this program were to deliver arrays of 250 lines of 400 pixels each and some associated electronics. Some arrays were delivered on tube-compatible headers and some were delivered after incorporation in vacuum tubes. Delivery of these devices required considerable improvements to be made in the processing associated with intensified operation. These improvements resulted in a high yield in the thinning process, reproducible results in the accumulation process, elimination of a dark current source in the accumulation process, solution of a number of header related problems, and the identification of a remaining major source of dark current. Two systematic failure modes were identified and protective measures established. The effects of tube processing on the arrays in the delivered ICCDs were determined and are reported along with the characterization data on the arrays.

Walker, J. W.↗

A photon-counting multichannel spectrometer

A multichannel detector system is described in which the positions of individual photon events in a high-gain image intensifier are decoded in the output of a video detector. The high-gain intensifier consists of a pair of three-stage electrostatic image-tube assemblies each containing three fiber-optically-coupled tubes potted in a rugged package with an internal high-voltage supply. Operation of the electrooptical system is discussed along with the pulse-detection process and the operation of the spectrograph in which the image-tube assembly is mounted. It is noted that the spectrometer detects 1.0 count/sec per A for an object of magnitude 13.0 at the peak of its response in the visual band when no light is lost on the slit, that a 10% coincidence correction is reached at an overall count rate of 860 per sec, and that the response follows an exponential law up to count rates of about 4000 per sec. The measured spectrum of the Seyfert galaxy NGC 5548 is provided as an example of the raw data produced by the instrument on a 1.5 meter telescope.

Shectman, S. A.↗