Search NASA⌕ Search

SEARCH · Search NASA

Results for “physical tests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Real-Time Temperature Field State Observer and Digital Replica to Support Cyber-Physical Testing

Cyber-physical testing is a class of experimental methods in which a system is partitioned into physical and numerical components to study its overall behavior. Transfer systems are typically needed to capture relevant interactions by enforcing appropriate interface conditions between the physical and numerical portions. While cyber-physical testing is often performed using lumped-parameter systems, thermomechanical cyber-physical testing requires the use of thermal actuators as transfer systems to apply a thermal condition over a spatially distributed region or surface. Thus, the interactions between the numerical and physical components are of a distributed nature, i.e., a field rather than point values. In this paper, we develop and experimentally validate a state observer for temperature fields to enable thermomechanical cyber-physical testing. The state observer provides continuous estimates of temperature over a surface of the thermal actuator using only temperature measurements at discrete locations. The estimated temperature field is then leveraged to account for localized mechanical defects in the interface condition. The method consists of building a digital replica of one portion of the control plant. By imposing defects in the digital replica it is used to generate and output the response of a thermal load pattern that represents that of a physical system with mechanical defects.

Manuel Salmeron↗

Thermal Actuator Identification and Control for Thermomechanical Real-Time Cyber–Physical Testing

Thermomechanical cyber–physical testing enables two-way thermal coupling between a numerical and an experimental subsystem. The interactions between the numerical model and the physical specimen occur through transfer systems, which enforce interface conditions. Thus, efficient control methodologies are necessary to achieve the desired interface interaction through thermal actuators with minimal error. This study introduces a novel thermal transfer system that imposes distributed cooling (or heating) thermal loads on a physical subsystem. First, the thermal actuator is identified considering switching-mode continuous dynamics for heating and cooling conditions. A switching-mode estimation algorithm is adopted to estimate the operating thermal cycle of the actuator in real-time. A control system is developed to experimentally impose the desired temperature and reduce tracking error (i.e., the error between the desired and actual temperature) under different thermal cycles. The identification and control of the thermal transfer system are then validated through a set of experiments considering different temperature rates of change. The developed control system is found to effectively minimize tracking errors in real-time cyber–physical experiments.

Herta Montoya↗

Role of Cyber-Physical Testing in Developing Resilient Extraterrestrial Habitats

Extraterrestrial long-term habitat systems (henceforth referred to as habitat systems) require groundbreaking technological advances to overcome the extreme demands introduced by isolation and challenging environments. A habitat system must operate as intended under continuous disruptive conditions. Designing for the demands that challenging environments will place on habitat systems (e.g., wild temperature fluctuations, galactic cosmic rays, destructive dust, meteoroid impacts, vibrations, and solar particle events) represents one of the greatest challenges in this endeavor. This engineering problem necessitates that we design and manage habitat systems to be resilient. System resilience requires a comprehensive approach that accounts for disruptions through the design process and adapts to them in operation. As the habitat system evolves—growing in physical size, complexity, population, and connectivity—and diversifies in operations, it must continue to be safe and resilient. In this endeavor, we should take advantage of lessons learned in developing civil infrastructure responsive to catastrophic natural hazards, autonomous robotics platforms, smart buildings, cyber-physical testing, complex systems, and diagnostics and prognostics for intelligent health management. This study highlights the importance of system resilience and cyber-physical testing to address the grand challenge of developing habitat systems.

Public health and safety↗

Particle Size Measurements From the First Fundamentals of Ice Crystal Icing Physics Test in the NASA Propulsion Systems Laboratory

This paper presents particle measurements by the Artium Technologies, Inc. Phase Doppler Interferometer and High Speed Imaging instruments from the first Fundamental Ice Crystal Icing Physics test conducted in the NASA Propulsion Systems Laboratory. The work focuses on humidity sweeps at a larger and a smaller median volumetric diameter. The particle size distribution, number density, and water content measured by the Phase Doppler Interferometer and High Speed Imaging instruments from the sweeps are presented and compared. The current capability for these two instruments to measure and discriminate ICI conditions is examined.

Aircraft icing↗

Particle Size Measurements from the first Fundamentals of Ice Crystal Icing Physics Test in the NASA Propulsion Systems Laboratory

This presentation shows particle measurements by the Artium Technologies, Inc. Phase Doppler Interferometer and High Speed Imaging instruments from the first Fundamental Ice Crystal Icing Physics test conducted in the NASA Propulsion Systems Laboratory. The work focuses on humidity sweeps at a larger and a smaller median volumetric diameter. The particle size distribution, number density, and water content measured by the Phase Doppler Interferometer and High Speed Imaging instruments from the sweeps are presented and compared. The current capability for these two instruments to measure and discriminate ICI conditions is examined.

thermal scaling↗

Evaluation Methodologies for Early Conceptual Design Using Virtual Reality and Physical Test Environments

In this study, human factor design engineers wanted to know, by using subject matter experts (SMEs), if there would be any differences in testing low-fidelity conceptual designs in a physical environment compared to a digital/virtual one. Results indicated that when testing a design concept at this early stage, a high correlation between the two environments exists, meaning SMEs found little to no difference when evaluating a design in either a physical or a digital/virtual environment. There are advantages and limitations to both environments. The virtual world gave the experts a better sense of the microgravity space environment and the relationships of space and human presence that are difficult to simulate in a 1-g physical environment. However, the interaction between human and mechanics is better enhanced in the physical world compared to the virtual world. These advantages and limitations of each environment are important; however, cost is also an important consideration when early design concepts are being used. With the cost analysis of materials, hardware, and labor conducting for this study, virtual reality showed a 68% decrease in cost over the physical mock-up build. Thus, taking all aspects of the study into consideration, at this early design life cycle phase, virtual reality shows great promise as an evaluation environment for testing early design concepts that will cost less, give more options, and increase designer’s time to design.

Harry L. Litaker Jr↗

Correlation of Chemical and Physical Test Data For the Environment Ageing of Coflon (PVDF)

This report aims to identify correlations between mechanical property changes and chemical/morphological structure changes for Coflon. It is intended both to illustrate the overall methodology and to indicate the testing that needs to be undertaken in order to obtain correlations. Many fluid exposures have now been carried out on Coflon during the project and many data generated as a result. The report summarises the changes observed in mechanical and physical properties and relates these as well as possible to the chemistry thought to be occurring during ageing. For this purpose, data have been collated from already-issued MERL and TRI technical and progress reports. Most of the mechanical testing of aged testpieces has been performed soon after the completion of the exposure; however, there is of necessity a delay in obtaining chemical analysis of the same testpieces, so that more physical than chemical data are shown. Three fluids have so far caused measurable deterioration of Coflon, these being: methanol (Fluid A), a methanol and amine mixture (Fluid G), and a mixture of methane, carbon dioxide gas and hydrogen sulphide gas plus aqueous amine (Fluid F). Only the effects of these fluids will be dealt with in any detail in this report, although other fluids are assessed to give relevant background information. Relevant test data collated here include: tensile modulus and related properties, mode of sample failure at break, fracture toughness, fatigue crack growth rate and resistance, stress relaxation rate, permeation coefficients, % crystallinity and molecular weight distributions together with changes in fluorine levels, and other observations where appropriate. However, not all of these were obtained for every ageing condition. Because of the wide range of tests employed, and the different ways in which their results are obtained, the following section has been included to serve as a background for making comparisons.

Morgan, G. J.↗

Fabrication and physical testing of graphite composite panels utilizing woven graphite fabric with current and advanced state-of-the-art resin systems

Three weaves were evaluated; a balanced plain weave, a balanced 8-harness satin weave, and a semiunidirectional crowfoot satin weave. The current state-of-the-art resin system selected was Fiberite's 934 Epoxy; the advanced resin systems evaluated were Phenolic, Phenolic/Novolac, Benzyl and Bismaleimide. The panels were fabricated for testing on NASA/Ames Research Center's Composites Modification Program. Room temperature mechanical tests only were performed by Hitco; the results are presented.

Lee, S. C. S.↗

Accuracy of gravitational physics tests using ranges to the inner planets

A number of different types of deviations from Kepler's laws for planetary orbits can occur in nonNewtonian metric gravitational theories. These include secular changes in all of the orbital elements and in the mean motion, plus additional periodic perturbations in the coordinates. The first order corrections to the Keplerian motion of a single planet around the Sun due to the parameterized post Newtonian theory parameters were calculated as well as the corrections due to the solar quadrupole moment and a possible secular change in the gravitational constant. The results were applied to the case of proposed high accuracy ranging experiments from the Earth to a Mercury orbiting spacecraft in order to see how well the various parameters can be determined.

Ashby, N.↗

Preparation, characterization, physical testing and performance of flurocarbon membranes and separators

The direct fluorination method of converting carefully selected hydrocarbon substrates to fluorinated membranes was successfully applied to produce promising, novel membranes for electrochemical devices. A family of polymer blends was identified which permits wide latitude in the concentration of both crosslinks and carboxyl groups in hydrocarbon membranes. The membranes of paragraph two were successfully fluorinated.

Lagow, R. J.↗

Preparation, characterization, physical testing and performance of fluorocarbon membranes and separators

The direct fluorination method of converting carefully selected hydrocarbon substrates to fluorinated membranes was successfully applied to produce promising, novel membranes for electrochemical devices. A family of polymer blends was identified which permits wide latitude in the concentration of both crosslinks and carboxyl groups in hydrocarbon membranes. These membranes were successfully fluorinated and are potentially competitive with commercial membranes in performance, and potentially much cheaper in price.

Lagow, R. J.↗

Correlation of Chemical and Physical Test Data for the Environmental Ageing of Tefzel (ETFE)

In a similar approach to that used for the previously issued correlation report for Coflon (CAPP/M.10), this report aims to identify any correlations between mechanical property changes and chemical/morphological changes for Tefzel, using information supplied in other MERL and TRI project reports (plus latest data which will be included in final reports for Phase 1). Differences identified with Coflon behaviour will be of scientific interest as well as appropriate to project applications, as Tefzel and Coflon are chemical isomers. Owing to the considerable chemical resistance of Tefzel, much of its testing so far has been based on mechanical properties. Where changes have occurred, chemical analysis can now be targeted more effectively. Relevant test data collated here include: tensile modulus and related properties, permeation coefficients, % crystallinity, and other observations where significant. Fluids based on methanol and amine (Fluid G), a mixture of methane, carbon dioxide and hydrogen sulphide gases plus an aqueous amine solution (Fluid F), and an aromatic oil mix of heptane, cyclohexane, toluene and I-propanol (Fluid 1) have affected Tefzel to varying degrees, and are discussed in some detail herein.

Morgan, G. J.↗

Correlation of Chemical and Physical Test Data for the Environmental Ageing of Tefzel (ETFE)

In a similar approach to that used for the previously issued correlation report for Coflon (CAPP/M.10), this report aims to identify any correlations between mechanical property changes and chemical/morphological changes for Tefzel, using information supplied in other MERL and TRI project reports. Differences identified with Coflon behaviour will be of scientific interest as well as appropriate to project applications, as Tefzel and Coflon are chemical isomers. Owing to the considerable chemical resistance of Tefzel, much of its testing so far has been based on mechanical properties. Where changes have occurred, chemical analysis can now be targeted more effectively. Relevant test data collated here include: tensile modulus and related properties, permeation coefficients, % crystallinity, some crack growth resistance measurements, and other observations where significant. Fluids based on methanol and amine (Fluid G), a mixture of methane, carbon dioxide and hydrogen sulphide gases plus an aqueous amine solution (Fluid F), and an aromatic oil mix of heptane, cyclohexane, toluene and 1-propanol (Fluid I) have affected Tefzel to varying degrees, and are discussed in some detail herein.

Morgan, G. J.↗

Spacecraft environmental testing

Physical testing of Relay I satellite to approximate environment and stress during handling, launch, and orbital flight

RELAY I SATELLITE↗

Synthetic aperture radar images of ocean waves, theories of imaging physics and experimental tests

The physical mechanism for the synthetic Aperture Radar (SAR) imaging of ocean waves is investigated through the use of analytical models. The models are tested by comparison with data sets from the SEASAT mission and airborne SAR's. Dominant ocean wavelengths from SAR estimates are biased towards longer wavelengths. The quasispecular scattering mechanism agrees with experimental data. The Doppler shift for ship wakes is that of the mean sea surface.

Vesecky, J. F.↗

Simple test for physical stability of cryogenic tank insulation

Qualitative test determines the ability of insulation liners used on liquid hydrogen tanks to withstand stresses produced by the thermal shocks imparted to the insulation during tank filling and drainage. Test specimens are bonded to metal plates with a low thermal expansion coefficient and are immersed in liquid hydrogen.

Rossello, D.↗