Search NASA⌕ Search

SEARCH · Search NASA

Results for “piccolo”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

An Evaluation of Jet Impingement Heat Transfer Correlations for Piccolo Tube Application

Impinging jets have been used for a wide variety of applications where high rates of heat transfer are desired. This report will present a review of heat transfer correlations that have been published. The correlations were then added to the LEWICE software to evaluate the applicability of these correlations to a piccolo tube anti-icing system. The results of this analysis were then compared quantitatively to test results on a representative piccolo tube system.

Bond, Thomas↗

Coupling a recurrent neural network to SPAD TCSPC systems for real-time fluorescence lifetime imaging

Fluorescence lifetime imaging (FLI) has been receiving increased attention in recent years as a powerful diagnostic technique in biological and medical research. However, existing FLI systems often suffer from a tradeoff between processing speed, accuracy, and robustness. Inspired by the concept of Edge Artificial Intelligence (Edge AI), we propose a robust approach that enables fast FLI with no degradation of accuracy. This approach couples a recurrent neural network (RNN), which is trained to estimate the fluorescence lifetime directly from raw timestamps without building histograms, to SPAD TCSPC systems, thereby drastically reducing transfer data volumes and hardware resource utilization, and enabling real-time FLI acquisition. We train two variants of the RNN on a synthetic dataset and compare the results to those obtained using center-of-mass method (CMM) and least squares fitting (LS fitting). Results demonstrate that two RNN variants, gated recurrent unit (GRU) and long short-term memory (LSTM), are comparable to CMM and LS fitting in terms of accuracy, while outperforming them in the presence of background noise by a large margin. To explore the ultimate limits of the approach, we derive the Cramer-Rao lower bound of the measurement, showing that RNN yields lifetime estimations with near-optimal precision. To demonstrate real-time operation, we build a FLI microscope based on an existing SPAD TCSPC system comprising a 32 x 32 SPAD sensor named Piccolo. Four quantized GRU cores, capable of processing up to 4 million photons per second, are deployed on the Xilinx Kintex-7 FPGA that controls the Piccolo. Powered by the GRU, the FLI setup can retrieve real-time fluorescence lifetime images at up to 10 frames per second. The proposed FLI system is promising and ideally suited for biomedical applications, including biological imaging, biomedical diagnostics, and fluorescence-assisted surgery, etc.

47 OTHER INSTRUMENTATION↗

Side-channel Leakage Assessment Metrics: A Case Study of GIFT Block Ciphers

Determination of an adequate level of security and providing subsequent mechanisms to achieve it, is one of the most pressing problems regarding embedded computing devices. While there are some solutions available for resource-rich computer systems, direct application of these solutions to resource-constrained environments are often unfeasible. The fundamental problem for such resource-constrained systems is the fact that current cryptographic algorithms utilize significant energy consumption and storage overhead. Both the cryptographic algorithm and its physical implementation affect the resilience of a cryptosystem against side-channel attacks. A side-channel attack represents a process that exploits leakages in order to extract sensitive information such as the key. This paper focuses on Correlation Power Analysis (CPA) which is side-channel attack based on the power consumption leakage. In 2016 the U.S. Commerce Department’s National Institute of Standards and Technology (NIST) initiated the call for proposals of new cryptographic algorithms to strengthen the cryptographic defense of networked devices against cyberattacks and to protect the data created by those innumerable device. This work evaluates S-boxes used by NIST candidates PICCOLO, GIFT, and PRESENT, as well as several S-box variants that demonstrated sufficient weaknesses against classical cryptanalysis, for a quantitative comparison in terms of resiliency to CPA attack. Three well-known theoretical metrics are evaluated: transparency order (TO and RTO), nonlinearity, and signal-to-noise (SNR) ratio, aiming to characterize the resistance of these S-boxes against adversaries exploiting physical leakages. Experimental results from attacks on an 8- bit XMEGA were obtained via the ChipWhisperer platform and of all the S-boxes evaluated, GIFT64 with a PICCOLO S-box was found to be the most susceptible to CPA. Results showed that variations in TO and RTO were not sufficient to ensure practical CPA resistance and that among S-boxes with equal non-linearity there were no significant differences in the TO and SNR variants.

97 MATHEMATICS AND COMPUTING↗

Side-channel Leakage Assessment Metrics: A Case Study of GIFT Block Ciphers

Determination of an adequate level of security and providing subsequent mechanisms to achieve it, is one of the most pressing problems regarding embedded computing devices. While there are some solutions available for resource-rich computer systems, direct application of these solutions to resource-constrained environments are often unfeasible. The fundamental problem for such resource-constrained systems is the fact that current cryptographic algorithms utilize significant energy consumption and storage overhead. Both the cryptographic algorithm and its physical implementation affect the resilience of a cryptosystem against side-channel attacks. A side-channel attack represents a process that exploits leakages in order to extract sensitive information such as the key. This paper focuses on Correlation Power Analysis (CPA) which is side-channel attack based on the power consumption leakage. In 2016 the U.S. Commerce Department’s National Institute of Standards and Technology (NIST) initiated the call for proposals of new cryptographic algorithms to strengthen the cryptographic defense of networked devices against cyberattacks and to protect the data created by those innumerable device. This work evaluates S-boxes used by NIST candidates PICCOLO, GIFT, and PRESENT, as well as several S-box variants that demonstrated sufficient weaknesses against classical cryptanalysis, for a quantitative comparison in terms of resiliency to CPA attack. Three well-known theoretical metrics are evaluated: transparency order (TO and RTO), nonlinearity, and signal-to-noise (SNR) ratio, aiming to characterize the resistance of these S-boxes against adversaries exploiting physical leakages. Experimental results from attacks on an 8- bit XMEGA were obtained via the ChipWhisperer platform and of all the S-boxes evaluated, GIFT64 with a PICCOLO S-box was found to be the most susceptible to CPA. Results showed that variations in TO and RTO were not sufficient to ensure practical CPA resistance and that among S-boxes with equal non-linearity there were no significant differences in the TO and SNR variants.

97 MATHEMATICS AND COMPUTING↗

Autonomous Soaring 2005 Flight Data Summary

Flight testing of the 14ft span CloudSwift UAV was conducted during the summer of 2005. Test maneuvers included aircraft checkout, Piccolo gain tuning, FTS range tests, and thermal soaring research flights.

Allen, Michael J.↗

Automated UAS Measurements of Reflectance and Solar Induced Florescence (SIF) for Assessment of the Dynamics in Photosynthetic Function, Application for Maize (Zea Mays L.) in Greenbelt, Maryland, US

To enable monitoring of the parameters governing photosynthesis at the temporal frequency relevant to their dynamics and at a spatial scale that allows practical assessment and management there is a strong need for advancement in the UAS remote sensing methods and instruments. Currently, no single sensor can provide data at the desired high temporal, spectral and spatial resolutions. Our field measurements obtained using the integrated UAS Piccolo system during the summers of 2017 and 2018 demonstrate that science quality reflectance and solar induced fluorescence (SIF) data can be retrieved with high temporal frequency using small Unmanned Aerial Systems (UAS). The implemented approach facilitates consistent data comparisons in space and time and facilitates their integration with other spectral satellite and airborne data.

Petya Campbell↗

Automated Uas Measurements of Reflectance and Solar Induced Florescence (SIF) for Assessment Of the Dinamics in Photosynthetic Function, Application for Maze (Zea Mays L.) in Greenbelt, Maryland, Us

For accurate assessment of vegetation function there is a strong need for advancement in the remote sensing methods and instruments, to enable monitoring of the parameters governing photosynthesis at the temporal frequency relevant to their dynamics and at a spatial scale that allows practical assessment and management. Currently, no single sensor can provide data at the desired high temporal, spectral and spatial resolutions. Our field measurements obtained using the integrated UAS Piccolo system during the summers of2017 and 2018 demonstrate that science quality reflectance and solar induced fluorescence (SIF) data can be retrieved with high temporal frequency using small Unmanned Aerial Systems (UAS). The implemented approach facilitates data comparisons through space and time, and the integration with other spectral satellite and airborne data. This investigation contributes for bridging the gap in Earth observation between field and airborne measurements by implementing autonomous methods for obtaining high temporal frequency spectroscopy measurements from an Unmanned Aerial Systems (UAS) at various illumination conditions. An advancement in the Intelligent Payload Module (IPM) facilitated the implementation of an optimization workflow to collect spectral data for characterizing vegetation reflectance and solar induced fluorescence (SIF).

Petya Campbell↗

The Zooplankton International Geospatial dataset: A global repository of spatiotemporal freshwater zooplankton community composition data from lakes and reservoirs to support ecological research

Zooplankton transfer substantial energy in aquatic food webs and are used as indicators of environmental change. Syntheses of zooplankton community dynamics globally require datasets that span a wide range of environmental gradients; however, these datasets are limited due to methodological differences across programs, taxonomic inconsistencies, and a lack of standardized metadata. To reconcile these challenges, we created the Zooplankton International Geospatial (ZIG) dataset, which includes original zooplankton, water physical and chemical variables, and lake morphometric data from 311 inland lakes and reservoirs. ZIG includes waterbodies ranging in size from 0.005 to 82,100 km2 and spanning broad latitudinal (−47.26 to 64.90) and longitudinal ranges (−165.04 to 176.53). Temporal coverage for individual waterbodies ranges between 1 and 60 yr with sampling frequency ranging from annually to weekly. With its extensive coverage and content, we consider ZIG to be a cornerstone for future investigations of global scale lake biodiversity change.

Figary, Stephanie [Cornell University, Ithaca, NY]↗

RPC background studies at CMS experiment

During Run2 the high instantaneous luminosity, up to 2.2 · 10 34 cm -2 s -1 , lead to a substantial hit rate in the Compact Muon Solenoid experiment’s muon chambers due to multiple background sources to physics processes sought for at LHC. In this article we will describe the analysis method devised to measure and identify the contributions to such background in the Resistive Plate Chambers. Thorough understanding of the background rates provides the base for the upgrade of the muon detectors for the High-Luminosity LHC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RPC based tracking system at CERN GIF++ facility

With the HL-LHC upgrade of the LHC machine, an increase of the instantaneous luminosity by a factor of five is expected and the current detection systems need to be validated for such working conditions to ensure stable data taking. At the CERN Gamma Irradiation Facility (GIF++) many muon detectors undergo such studies, but the high gamma background can pose a challenge to the muon trigger system which is exposed to many fake hits from the gamma background. A tracking system using RPCs is implemented to clean the fake hits, taking profit of the high muon efficiency of these chambers. This work will present the tracking system configuration, used detector analysis algorithm and results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CMS RPC system readiness for LHC Run-3 data taking

During Run-3, the LHC is preparing to deliver instantaneous luminosity in the range from 5 × 10 34 cm -2 s -1 to 7.5 × 10 34 cm -2 s -1 . To ensure stable data taking, providing redundant information for robust muon triggering, reconstruction and identification, the CMS RPC collaboration has used the opportunity given by the LHC long shutdown 2 (LS2), to perform a series of maintenance and preparation activities for the new data taking period. The overall performance of the RPC system after the LS2 commissioning period and the activities in preparation for future data taking will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and commissioning of readout electronics for a $K$$^{0}_{L}$ and $μ$ detector at the Belle II experiment

The K-long and muon detector (KLM) constitutes the outer-most volume of the Belle II spectrometer at the interaction region of the SuperKEKB collider in Tsukuba, Japan. The KLM detector was partially upgraded since the Belle experiment by replacing many of its resistive-plate chambers with scintillators containing wavelength-shifting fibers and instrumenting it with silicon photomultipliers. Here, we describe the readout electronics, firmware, and software created to control and acquire data from the scintillators and resistive-plate chambers.

Belle II↗