Search NASA⌕ Search

SEARCH · Search NASA

Results for “picometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Sub-Picometer Dynamic Measurements of a Diffuse Surface

Future space observatory missions are forecasting the need for sensing and controlling wave front error and system alignment stability to picometer scale. Picometer stability performance demands precision knowledge of the mirror and metering structure materials to the same degree. A high-speed electronic speckle pattern interferometer was designed and built to demonstrate measurements of both static and dynamic responses of picometer amplitudes in materials of diffuse surface subjected to very low energy disturbances. This paper describes the details of a test to impart a dynamic disturbance of picometer scale and measure the response of a composite material.The results of the test are also reported and show conclusively that sub-picometer scale effects can be accurately measured in an open test environment outside a vacuum chamber.

Saif, Babak↗

Picometer Level Spatial Metrology for Next Generation Telescopes

During the testing of the primary mirror segments for JWST, our team realized that some of the tools and techniques we had developed could be pushed further to achieve picometer resolution.We began developing incremental techniques for measuring, controlling, sensing to picometer levelsSeveral recent peer reviewed papers have shown that we can measure this level of change, control it with actuators, and potentially even develop active architectures using these ideasWe will show how the work on JWST evolved to systems applicable to measure picometer and even sub-picometer levels, show the results, and discuss implications for future telescope like LUVOIR and Habex

Keski-Kuha, R.↗

Picometer-level metrology of test articles on the road to Habitable Worlds Observatory

The Habitable Worlds Observatory will revolutionize our understanding of the universe by directly detecting biosignatures on extrasolar planets and allow us to answer the question if we are alone in the universe. To accomplish the tight science goals associated with this mission, the development of an ultrastable observatory with a coronagraphic instrument is necessary. The observatory itself may need to stay stable on the order of 10 picometers over a wavefront control cycle, orders of magnitude more stable than what is required on current space missions. The metrology to verify stability requirements must be roughly a factor of ten more stable. The ultrastable laboratory at NASA’s Goddard Space Flight Center has further stabilized its testbed to allow for dynamic measurements on diffuse and specular objects on the order of single picometers, and we are currently measuring drifts on the orders of tens of picometers over different temporal bands. This paper will discuss the mechanical updates to the testbed setup, the analysis performed on several test articles, and the path forward on the road to measuring achieving the required stability for Habitable Worlds Observatory.

Inteferometry↗

Picometer-Level Metrology of Test Articles on the Road to Habitable Worlds Observatory

The Habitable Worlds Observatory will revolutionize our understanding of the universe by directly detecting biosignatures on extrasolar planets and allow us to answer the question if we are alone in the universe. To accomplish the tight science goals associated with this mission, the development of an ultrastable observatory with a coronagraphic instrument is necessary. The observatory itself may need to stay stable on the order of 10 picometers over a wavefront control cycle, orders of magnitude more stable than what is required on current space missions. The metrology to verify stability requirements must be roughly a factor of ten more stable. The ultrastable laboratory at NASA’s Goddard Space Flight Center has further stabilized its testbed to allow for dynamic measurements on diffuse and specular objects on the order of single picometers, and we are currently measuring drifts on the orders of tens of picometers over different temporal bands. This paper will discuss the mechanical updates to the testbed setup, the analysis performed on several test articles, and the path forward on the road to measuring achieving the required stability for Habitable Worlds Observatory.

Inteferometry↗

Picometer-Level Metrology on the Road to Habitable Worlds Observatory

The Habitable Worlds Observatory will revolutionize our understanding of the universe by directly detecting biosignatures on extrasolar planets and allow us to answer the question if we are alone in the universe. To accomplish the tight science goals associated with this mission, the development of an ultrastable observatory with a coronagraphic instrument is necessary. The observatory itself may need to stay stable on the order of 10 picometers over a wavefront control cycle, orders of magnitude more stable than what is required on current space missions. The metrology to verify stability requirements must be roughly a factor of ten more stable. The ultrastable laboratory at NASA’s Goddard Space Flight Center has further stabilized its testbed to allow for dynamic measurements on diffuse and specular objects on the order of single picometers, and we are currently measuring drifts on the orders of tens of picometers over different temporal bands. This paper will discuss the mechanical updates to the testbed setup, the analysis performed on several test articles, and the path forward on the road to measuring achieving the required stability for Habitable Worlds Observatory.

Inteferometry↗

Solar Confocal Interferometers for Sub-Picometer-Resolution Spectral Filters

The confocal Fabry-Perot interferometer allows sub-picometer spectral resolution of Fraunhofer line profiles. Such high spectral resolution is needed to keep pace with the higher spatial resolution of the new set of large-aperture solar telescopes. The line-of-sight spatial resolution derived for line profile inversions would then track the improvements of the transverse spatial scale provided by the larger apertures. The confocal interferometer's unique properties allow a simultaneous increase in both etendue and spectral power. Methods: We have constructed and tested two confocal interferometers. Conclusions: In this paper we compare the confocal interferometer with other spectral imaging filters, provide initial design parameters, show construction details for two designs, and report on the laboratory test results for these interferometers, and propose a multiple etalon system for future testing of these units and to obtain sub-picometer spectral resolution information on the photosphere in both the visible and near-infrared.

Gary, G. Allen↗

Solar Confocal interferometers for Sub-Picometer-Resolution Spectral Filters

The confocal Fabry-Perot interferometer allows sub-picometer spectral resolution of Fraunhofer line profiles. Such high spectral resolution is needed to keep pace with the higher spatial resolution of the new set of large-aperture solar telescopes. The line-of-sight spatial resolution derived for line profile inversions would then track the improvements of the transverse spatial scale provided by the larger apertures. In particular, profile inversion allows improved velocity and magnetic field gradients to be determined independent of multiple line analysis using different energy levels and ions. The confocal interferometer's unique properties allow a simultaneous increase in both etendue and spectral power. The higher throughput for the interferometer provides significant decrease in the aperture, which is important in spaceflight considerations. We have constructed and tested two confocal interferometers. A slow-response thermal-controlled interferometer provides a stable system for laboratory investigation, while a piezoelectric interferometer provides a rapid response for solar observations. In this paper we provide design parameters, show construction details, and report on the laboratory test for these interferometers. The field of view versus aperture for confocal interferometers is compared with other types of spectral imaging filters. We propose a multiple etalon system for observing with these units using existing planar interferometers as pre-filters. The radiometry for these tests established that high spectral resolution profiles can be obtained with imaging confocal interferometers. These sub-picometer spectral data of the photosphere in both the visible and near-infrared can provide important height variation information. However, at the diffraction-limited spatial resolution of the telescope, the spectral data is photon starved due to the decreased spectral passband.

Gary, G. Allen↗

Breakthroughs in Picometer Ultra-Stable Spatial Metrology Systems for Next Generation Telescopes

Goal is to discover and characterize habitable planet candidates around Sun-like stars. Need 10(exp -10) contrast between reflected earth like planet and sun like stars. Options are internal Coronagraphs (LUVOIR and Habex) and large starshades (Habex) which each have pros and cons. Coronagraphs require 10(exp -10)contrast stability which means the primary mirror must be stable to roughly 10 picometers RMS wavefront over an exposure(minutes). Simplistically: Primary mirror instabilities of 10 picometers in certain spatial frequencies look like planets!

Feinberg, Lee↗

Picometer knowledge transfer: overview and status

The Picometer Knowledge Transfer testbed is one of several technology testbeds that will help to prove technology readiness for the Space Interferometry Mission (SIM).

picometer interferometer SIM↗

Picometer Level Modeling of a Shared Vertex Double Corner Cube in the Space Interferometry Mission Kite Testbed

The Space Interferometry Mission (SIM) is a microarcsecond interferometric space telescope that requires picometer level precision measurements of its truss and interferometer baselines. Single-gauge metrology errors due to non-ideal physical characteristics of corner cubes reduce the angular measurement capability of the science instrument. Specifically, the non-common vertex error (NCVE) of a shared vertex, double corner cube introduces micrometer level single-gauge errors in addition to errors due to dihedral angles and reflection phase shifts. A modified SIM Kite Testbed containing an articulating double corner cube is modeled and the results are compared to the experimental testbed data. The results confirm modeling capability and viability of calibration techniques.

metrology↗

A Multichannel Averaging Phasemeter for Picometer Precision Laser Metrology

The Micro-Arcsecond Metrology (MAM) team at the Jet Propulsion Laboratory has developed a precision phasemeter for the Space Interferometry Mission (SIM). The current version of the phasemeter is well-suited for picometer accuracy distance measurements and tracks at speeds up to 50 cm/sec, when coupled to SIM's 1.3 micron wavelength heterodyne laser metrology gauges. Since the phasemeter is implemented with industry standard FPGA chips, other accuracy/speed trade-off points can be programmed for applications such as metrology for earth-based long-baseline astronomical interferometry (planet finding), and industrial applications such as translation stage and machine tool positioning. The phasemeter is a standard VME module, supports 6 metrology gauges, a 128 MHz clock, has programmable hardware averaging, and a maximum range of 232 cycles (2000 meters at 1.3 microns).

Halverson, Peter G.↗

Large Stroke, Picometer Resolution Hexapod for Dynamic Mirror Positioning

Viewgraph presentation reviews the Fast Picometer Mirror mounting (FPMM) for the Terrestrial Planet Finder Coronagraph (TPF-C). Included in the presentation are slides with an overviews of the TPF-C, the requirements of the FPMM, the selection of the materials using the ACE system, and the architecture of the FPMM.

Ohl, Raymond G.↗

Picometer Differential Wavefront Metrology by Nonlinear Zernike Wavefront Sensing for LUVOIR

We propose the Nonlinear Zernike wavefront sensor (NLZWFS) for out-of-band differential wavefront sensing to augment primary mirror stability on LUVOIR and similar mission concepts during exoplanet coronagraphy. This new data analysis paradigm involving a full polychromatic scalar physical optics model for the phase-shifting Zernike wavefront sensor removes the linearity assumptions which would otherwise prevent accurate sensing. We show Monte-Carlo simulations of NLZWFS and focus-diverse phase retrieval to understand the exposure times necessary to achieve picometer-level stability in the telescope wavefront.

Redding, David C.↗