Highly stretchable miniature strain sensor for large dynamic strain measurement

In this paper, a new type of highly stretchable strain sensor was developed to measure large strains. The sensor was based on the piezo-resistive response of carbon nanotube (CNT)/polydimethylsiloxane (PDMS) composite thin films. The piezo-resistive response of CNT composite gives accurate strain measurement with high frequency response, while the ultra-soft PDMS matrix provides high flexibility and ductility for large strain measurement. Experimental results show that the CNT/PDMS sensor measures large strains (up to 8 %) with an excellent linearity and a fast frequency response. The new miniature strain sensor also exhibits much higher sensitivities than the conventional foil strain gages, as its gauge factor is 500 times of that of the conventional foil strain gages.

47 OTHER INSTRUMENTATION↗

Self-powered Wireless Dual-mode Langasite Sensor for Pressure/Temperature Monitoring of Nuclear Reactors

Safety issues in nuclear power plants are of extreme importance. Numerous sensors are used within nuclear power plants for sensing and monitoring of its critical operation parameters. As currently implemented, during massive losses of power across the plant in accidents, the backup batteries for the monitoring sensors will ultimately be drained and can cease to operate. The overall objective of this NEUP project is to develop a novel self-powered wireless hybrid sensor which can accurately monitor both pressure and temperature using a single device, even in the extreme harsh environments of severe nuclear accidents, without the requirement of external electricity. At Virginia Tech side, a heat pipe assisted thermoelectric generator (TEG) energy harvester and associated power management and data transmission circuits were developed. The energy harvester can produce electrical power continuously, even in loss of plant and external power situations, providing power for important data transmission for accident diagnosis. The self-powered sensing system could be integrated directly onto key nuclear components including pipes, pump housings, heat exchangers, reactor vessels, and shielding structures inside and outside of the reactor core. Two TEG based energy harvesters which can work in relatively low (50-250 ºC) and high temperature ranges (250-350 ºC) were established and tested. In the prototypes, heat pipes were introduced to reduce the heat resistances of the device at the hot and cold ends. The power output of the heat pipe assisted TEG module is 2.22 W, which is 6 times more than one using an aluminum rod. In-lab tests showed that these devices canmeet the requirement to power the sensors and circuit during normal and off-normal conditions.Amodel was then built to analyze the thermal network in the energy harvester, and was used to optimize its performance and reduce its geometry size. The design and testing of the vibrational energy harvester were completed. The harvester, has shown to effectively increase the vibrational potential of the main coolant pump, though it has been shown that thermal energy has a much higher potential for the powering of sensors. In this project, a self-start charger circuit for the energy harvester was designed to regulate and manage the power. An energy storage element was incorporated into the energy harvesting module for sensors and wireless transceivers in an off-normal situation. The signal conditioning and wireless communication electronic circuits were developed and tested in the lab. An important consideration for an energy harvester within a nuclear power plant is the level of radiation it will encounter during operation. The two main sources of radiation in a nuclear power plant are gamma and neutron radiation. Aradiation experiment was conducted in the Westinghouse Electric Company during which the prototypes were placed in a 106 rad radiation environment to test their ability to operate in the extreme environment. The results showed that this level of radiation had little effect on the performance of the TEGmaterial and heat pipe heat exchanging system. Its influence on the circuit was still under research, however the need for more development on radiation hardened electronics is needed. Pressure measurement based on piezoelectric crystal resonators has advantages over the commercially available methods like capacitive, electromagnetic, optical, potentiometric, and piezo resistive strain gauges. Since the output of piezoelectric based sensors are digital in format, it has a very high resolution, high accuracy, and long-term stability. Quartz is one of the commonly used piezoelectric material in digital pressure sensors design. This material is elastic in nature, providing high stability, high repeatability, high elasticity, repeatable mechanical behavior for many cycles of operation, and is free of hysteresis. The quartz resonator has a high Q, which means that very high vibration can be driven with the very low electric power. Langasite (LGS) is a new promising piezoelectric material that combines the advantageous properties of quartz with a better performance at high temperatures. LGS will not undergo any phase transitions up to its melting temperature of 1473 C, and hence, the application of Langasite in measuring pressure at high temperatures is promising. In this project, the design and fabrication of the piezo oscillator crystal for temperature and pressure measurement has been completed. The entire sensor has been fabricated and tested to see its sensitivity to temperature and pressure changes. The design and optimization of the radiation shielding systems that can effective protect the duel-mode Langasite sensor inside reactor core were demonstrated. To maximize the radiation shielding effectiveness, different types of materials are investigated based upon recent developments of radiation shielding systems including aluminum + Boron carbide and bismuth borosilicate glass B2O3 in addition to tungsten/B4C. New materials based upon metatheses is included as potential shielding to mitigate neutron fluencies. The radiation shielding effectiveness of selected composites are evaluated within a broader neutron spectrum from thermal, epithermal, fast (1 MeV) and 15 MeV neutrons. Performance analysis was also conducted to evaluate the effects of selected composite systems.Aconceptual design was also proposed for the packaging and integration of the radiation shielding system with the sensor, and its applicability within the reactor core was discussed. At end of the project, all components necessary for a complete sensing and monitoring system, including a langasite sensor, electrodes, the TEG harvester, an energy storage device, and power management and transmission electronics were integrated to demonstrate feasibility in powering the sensor. Finally, integration of each component into a full package, and a full demonstration were done.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Elastomeric Nanocomposite with Solvent‐Free, One Step, In Situ Shear Exfoliation of Graphite to Graphene

A graphene nanoflake (GNF)‐enhanced elastomeric nanocomposite (G‐EMC) is fabricated following an innovative, cost‐effective, single‐step, in situ shear exfoliation (ISE) method from low‐cost bulk material, graphite, where uniform mixing happens simultaneously within the elastomer matrix. Electron microscopy, atomic force microscopy, and photo‐induced force microscopy results show good dispersion of GNFs with exfoliation to a few layers and uniform distribution in the elastomer matrix. X‐ray photoelectron spectroscopy analysis shows less than 1% oxygen‐containing functional groups/impurity, enhanced bonding through the formation of edge sites as fracture occurs across the GNF basal plane, and pi‐pi interactions with newly exfoliated planar basal plane surfaces of the GNFs. Raman spectroscopy results confirm the formation of GNFs with only a few layers of graphene formed by the ISE process. Fabricated 10 wt.% G‐EMC nanocomposites show a 400%–500% increase in strength and fracture toughness. And 35 wt.% G‐EMCs provide an electrical conductivity of 25.64 S m −1 and a sensor gauge factor of 45. The resulting intrinsic piezo resistivity of the fabricated nanocomposite has been exploited to fabricate a multi‐functional wired and wireless sensor for detecting different body movements, speech, human vital functions, solvents, and biomolecules.

36 MATERIALS SCIENCE↗

Minimizing manganin/system noise for potential use in small geometry experiments

Manganin gauges are piezo resistive devices often used for pressure measurements on larger, planer impact experiments. These gauges function in this capacity as a result of their ability to change resistance in a consistent fashion relative to the pressure exerted against them. Pressures to 400 kbar have been reliably recorded (H.C. Vantine et al.[1]). Because the mini-manganin is significantly physically smaller than other types, there has been interest in the ability to place these gauges on small geometry (detonator) type experiments. Of primary concern is that the detonator shock front has significant curvature associated with it--especially at small geometries--and that this curvature will cause unknown distortion (stretching) of the manganin gauge and therefore may indicate erroneous data. A problem encountered while configuring this experiment was noise as a result of the proximity and high current levels of the fireset to the manganin gauge. Initial results indicate noise on the order of 130 mV peak-to-peak (p-p) and running as long as the CVR signal from the ringdown charge voltage of 775 V. These noise problems significantly worsened while discharging the full charge voltage of 1500 V on the fireset through the chip slapper.

42 ENGINEERING↗

Research on pressure sensors for biomedical instruments

The development of a piezo-resistive pressure transducer is discussed suitable for recording pressures typically encountered in biomedical applications. The pressure transducer consists of a thin silicon diaphragm containing four strain-sensitive resistors, and is fabricated using silicon monolithic integrated-circuit technology. The pressure transducers can be as small as 0.7 mm outer diameter, and are, as a result, suitable for mounting at the tip of a catheter. Pressure-induced stress in the diaphragm is sensed by the resistors, which are interconnected to form a Wheatstone bridge.

Angell, J. B.↗

Mars 2020 Entry, Descent, and Landing Instrumentation 2 (MEDLI2) Sensor Suite

The Mars 2020 Entry, Descent, and Landing Instrumentation 2 (MEDLI2) sensor suite seeks to address the aerodynamic, aerothermodynamic, and thermal protection system (TPS) performance issues during atmospheric entry, descent, and landing of the Mars 2020 mission. Based on the highly successful instrumentation suite that flew on Mars Science Laboratory (MEDLI), the new sensor suite expands on the types of measurements and also seeks to answer questions not fully addressed by the previous mission. Sensor Package: MEDLI2 consists of 7 pressure transducers, 17 thermal plugs, 2 heat flux sensors, and one radiometer. The sensors are distributed across both the heatshield and backshell, unlike MEDLI (the first sensor suite), which was located solely on the heat-shield. The sensors will measure supersonic pressure on the forebody, a pressure measurement on the aftbody, near-surface and in-depth temperatures in the heatshield and backshell TPS materials, direct total heat flux on the aftbody, and direct radiative heating on the aftbody. Instrument Development: The supersonic pressure transducers, the direct heat flux sensors, and the radiometer all were tested during the development phase. The status of these sensors, including the piezo-resistive pressure sensors, will be presented. The current plans for qualification and calibration for all of the sensors will also be discussed. Post-Flight Data Analysis: Similar to MEDLI, the estimated flight trajectory will be reconstructed from the data. The aerodynamic parameters that will be reconstructed will be the axial force coefficient, freestream Mach number, base pressure, atmospheric density, and winds. The aerothermal quantities that will be determined are the heatshield and backshell aero-heating, turbulence transition across the heatshield, and TPS in-depth performance of PICA. By directly measuring the radiative and total heat fluxes on the back-shell, the convective portion of the heat flux will be estimated. The status of the current tools to perform the post-flight data analysis will be presented, along with plans for model improvements.

Hwang, Helen H.↗

Mars 2020 Entry, Descent, and Landing Instrumentation 2 (MEDLI2) Sensor Suite

The Mars 2020 Entry, Descent, and Landing Instrumentation 2 (MEDLI2) sensor suite seeks to address the aerodynamic, aerothermodynamic, and thermal protection system (TPS) performance issues during atmospheric entry, descent, and landing of the Mars 2020 mission. Based on the highly successful instrumentation suite that flew on Mars Science Laboratory (MEDLI), the new sensor suite expands on the types of measurements and also seeks to answer questions not fully addressed by the previous mission. Sensor Package: MEDLI2 consists of 7 pressure transducers, 17 thermal plugs, 2 heat flux sensors, and one radiometer. The sensors are distributed across both the heatshield and backshell, unlike MEDLI (the first sensor suite), which was located solely on the heat-shield. The sensors will measure supersonic pressure on the forebody, a pressure measurement on the aftbody, near-surface and in-depth temperatures in the heatshield and backshell TPS materials, direct total heat flux on the aftbody, and direct radiative heating on the aftbody. Instrument Development: The supersonic pressure transducers, the direct heat flux sensors, and the radiometer all were tested during the development phase. The status of these sensors, including the piezo-resistive pressure sensors, will be presented. The current plans for qualification and calibration for all of the sensors will also be discussed. Post-Flight Data Analysis: Similar to MEDLI, the estimated flight trajectory will be reconstructed from the data. The aerodynamic parameters that will be reconstructed will be the axial force coefficient, freestream Mach number, base pressure, atmospheric density, and winds. The aerothermal quantities that will be determined are the heatshield and backshell aero-heating, turbulence transition across the heatshield, and TPS in-depth performance of PICA. By directly measuring the radiative and total heat fluxes on the back-shell, the convective portion of the heat flux will be estimated. The status of the current tools to perform the post-flight data analysis will be presented, along with plans for model improvements.

Hwang, Helen↗

Identification of Noise Sources in a Rocket Engine Test Stand using Microphone Phased Array

A new, phased array of microphones, suitable for the harsh environment of a rocket launch, was built and tested during a static firing of a RS-25 engine. It uses 70 piezo-resistive, dynamic pressure sensors, optimally distributed on a 10.5ft diameter open frame dome structure, and has a 200-ft long cable bundle to carry the signals to a weather-protected cabinet containing the data systems. The test stand was imaged using an infra-red camera and a visible wavelength camera, and the beamformed noise maps were superimposed on the photographs. The first-time data from a full-scale engine test stand showed that the plume deflector at the bottom of the engine to be the primary noise source. The openings of the test stand around the nozzle exit were also found to be noise sources particularly at higher frequencies. The final goal is to use the array during NASA’s Artemis-II launch at Kennedy Space Center.

Identification of Noise Source↗

Conductance control at the LaAlO{sub 3}/SrTiO{sub 3}-interface by a multiferroic BiFeO{sub 3} ad-layer

Multilayered BiFeO{sub 3} (BFO)/LaAlO{sub 3} (LAO) thin film samples were fabricated on SrTiO{sub 3} (STO) substrates by pulsed laser deposition. In this work, the ferroelectric polarization of a multiferroic BFO ad-layer on top of the quasi-two-dimensional electron gas (2DEG) at the LAO/STO interface is used to manipulate the conductivity of the quasi-2DEG. By microstructuring the conductive area of the LAO/STO-interface, a four-point geometry for the measurement of the resistivity was achieved. Piezo force microscopy allows for imaging and poling the spontaneous ferroelectric polarization of the multiferroic layer. The resistance changes showed a linear dependence on the area scanned and a hysteretic behavior with respect to the voltages applied in the scanning process. This is evidence for the ferroelectric polarization of the multiferroic causing the resistance changes. Coupling the antiferromagnetic BFO layer to another ferromagnetic layer could enable a magnetic field control of the conductance of the quasi-2DEG at the LAO/STO interface.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tactile Sensing for Dexterous Robotic Hands

Robotic systems will be used as precursors to human exploration to explore the solar system and expand our knowledge of planetary surfaces. Robotic systems will also be used to build habitats and infrastructure required for human presence in space and on other planetary surfaces . Such robots will require a high level of intelligence and automation. The ability to flexibly manipulate their physical environment is one characteristic that makes humans so effective at these building and exploring tasks . The development of a generic autonomous grasp ing capability will greatly enhance the efficiency and ability of robotics to build, maintain and explore. To tele-operate a robot over vast distances of space, with long communication delays, has proven to be troublesome. Having an autonomous grasping capability that can react in real-time to disturbances or adapt to generic objects, without operator intervention, will reduce the probability of mishandled tools and samples and reduce the number of re-grasp attempts due to dropping. One aspect that separates humans from machines is a rich sensor set. We have the ability to feel objects and respond to forces and textures. The development of touch or tactile sensors for use on a robot that emulates human skin and nerves is the basis for this discussion. We will discuss the use of new piezo-electric and resistive materials that have emerged on the market with the intention of developing a touch sensitive sensor. With viable tacti le sensors we will be one step closer to developing an autonomous grasping capability.

Martin, Toby B.↗

A Novel Technology for Complex Rheological Measurements - 16471

As the UK nuclear industry embarks on a second phase of nuclear power generation, the industry is faced with numerous sludge and slurry challenges associated with the decommissioning and clean-up of historical nuclear sites. The remediation of Sellafield, the largest nuclear site in the UK, is anticipated to cost GBP 53 bn over the next 100 years. Substantial cost is associated with the clean-up, transfer and safe storage of legacy particulate wastes encountered in ponds, silos, highly active storage tanks and many more large tanks on site. To develop suitable design strategies for the mobilization and transfer of sludge, the rheology of the sludge should be accurately determined. The current work demonstrates the use of a Quartz Crystal Microbalance to measure sludge rheology, specifically the shear yield stress. The device is simple to operate with no mechanical parts, small and portable enabling deployment into limited access areas, and eliminates the need for operator sampling and laboratory measurement. The measurement principle relates to the resonance frequency and motional resistance of a piezo-electric sensor as the sensor is submerged in the desired test material. The air-to-sample frequency and resistance shifts are shown to correlate with the shear yield stress of the suspension as measured by conventional vane viscometry. As the particle network stiffens (increased yield stress), the sensor motional resistance and its resonant frequency become more positive. These characteristic responses and their correlation to the shear yield stress have been confirmed for a range of particle suspensions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Electrical four-point probing of spherical metallic thin films coated onto micron sized polymer particles

Micron-sized metal-coated polymer spheres are frequently used as filler particles in conductive composites for electronic interconnects. However, the intrinsic electrical resistivity of the spherical thin films has not been attainable due to deficiency in methods that eliminate the effect of contact resistance. In this work, a four-point probing method using vacuum compatible piezo-actuated micro robots was developed to directly investigate the electric properties of individual silver-coated spheres under real-time observation in a scanning electron microscope. Poly(methyl methacrylate) spheres with a diameter of 30 μm and four different film thicknesses (270 nm, 150 nm, 100 nm, and 60 nm) were investigated. By multiplying the experimental results with geometrical correction factors obtained using finite element models, the resistivities of the thin films were estimated for the four thicknesses. These were higher than the resistivity of bulk silver.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Synthesis and optical characterization of LiKB4O7, Li2B6O10, and LiCsB6O10 glasses

In the current work we report on the synthesis of LiKB4O7, Li2B6O10, and LiCsB6O10 borate glasses. The results for their piezo-optic, acousto-optic, acoustic, elastic, refractive, optical transmission, and optical resistance properties are also presented. It is shown that some of these glasses represent efficient acousto-optic materials that are transparent down to the vacuum ultraviolet range and highly resistant to laser radiation.

36 MATERIALS SCIENCE↗

ORNL Quasi-Static Mechanical Characterization and Analysis: FY09 Annual Report to TARDEC

The testing and evaluation of candidate glasses for transparent armor served as a primary goal. Other armor ceramics were evaluated too, in support of the development of innovative test methods, whose use will ultimately help in the improvement of armor ceramics or help in better predicting their ballistic performance. The following summarizes this report and this year's work: (1) The elastic properties of a spherical indenter affect the forces necessary to initiate fracture in a target ceramics. The lower the elastic modulus of an indenter material, the easier (i.e., lower forces required) it is to initiate fracture. This implies the fracture initiation of an armor ceramic will depend on the elastic properties of a projectile material, and that this effect, represented by the Dundurs Parameter, can be managed to guide improvement of both armor and projectile materials. (2) The largest flaws in a population dictate both contact damage and fracture initiations. This implies the ballistic response of armor ceramics will improve if those large flaws are precluded from appearing in the materials during their processing. (3) Failure stress dependence on effective area for Hertzian indentation was developed. Such analysis is adaptable to predict ballistically produced fracture initiation as a function of projectile material and projectile size. (4) A simple, quick, and inexpensive test method was developed to measure the apparent yield stress of armor ceramics. This is significant because yield stress is used as input in ballistic models, and yield stress is traditionally measured using (complex, timeconsuming, and expensive) shock physics experiments. (5) Radial confinement increases the necessary indentation forces to initiate fracture and yield-like responses in ceramics. Ballistic improvement of an armor ceramic will occur if the ceramic can be compressively pre-stressed. (6) The median crack produced by a Hertzian indent is associated with a dramatic increase in target ceramic compliance. More so than any other produced damage mechanism. This suggests that a ballistically induced median crack in an armor ceramic may be associated with the dwell penetration event. (7) Glass exhibits tensile strength that is very much dependent on the amount of material, the side being tested (air versus tin if a float glass), and where it is being tensile stressed (in the middle or near an edge). The management of these effects will improve ballistic resistance of transparent armor (or any ceramic armor that is undergoing deflection as a consequence of a ballistic impact). (8) Plasma-arc heat treatment is a quick and relatively inexpensive method to improve the strength of glass. It is implementable into the production line for the mass production of glass. Increased strain-to-failure and bending deflections are concomitant with increased strength, and therefore, ballistic resistance is improvable using this method. (9) The Hertzian stress field at high contact stresses is very similar to the stress field from a ballistic impact. This is significant because the results from Hertzian indentation measurements have the prospect of being used as input in ballistic models to predict dwell conditions. (10) The understanding of glass densification and fragmentation behaviors are aided by piezo-Raman spectroscopy and quasi-static, high-energy fracture. Continued refinement of these test methods will improve the understanding of glass impact resistance. (11) In addition to glass, strength-size scaling was evident in SiC and B{sub 4}C. Previously proposed strength dependencies on rate from shock experiments may instead be explained by this strength-size scaling effect. (12) The quantification of strength-size scaling in armor ceramics clearly shows there is no single strength value that can be used to describe that ceramic. A ballistic modeler can therefore use more appropriate failure stress value(s) as input to predict deflection and expanding cavity responses in the ceramic target. These follow-on efforts are recommended based on the above statements: (1) Dynamic Hertzian indentation using a dynamic hardness tester; (2) Quantify flaw population size in strategic armor ceramics; (3) Refine and increase robustness of apparent yield stress measurement; (4) Quantify fracture and yield processed in armor ceramics as a function of confined stress; (5) Develop test method to accurately measure stress condition of median crack formation; (6) Measure strength-size scaling in glass ceramic candidates for transparent armor; (7) Refine plasma-arc heat treating to maximize strengthening of glasses and glass ceramics; (8) Refine ballistic modeling analysis to improve adaptability of Hertzian indentation results; (9) Refine densification and fragmentation test methods and interpretations; and (10) Predict ballistically-induced armor deflection and expanding cavity performance using strength-size scaling results.

36 MATERIALS SCIENCE↗

Note: A rigid piezo motor with large output force and an effective method to reduce sliding friction force

We present a completely practical TunaDrive piezo motor. It consists of a central piezo stack sandwiched by two arm piezo stacks and two leg piezo stacks, respectively, which is then sandwiched and spring-clamped by a pair of parallel polished sapphire rods. It works by alternatively fast expanding and contracting the arm/leg stacks while slowly expanding/contracting the central stack simultaneously. The key point is that sufficiently fast expanding and contracting a limb stack can make its two sliding friction forces well cancel, resulting in the total sliding friction force is <10% of the total static friction force, which can help increase output force greatly. The piezo motor's high compactness, precision, and output force make it perfect in building a high-quality harsh-condition (vibration resistant) atomic resolution scanning probe microscope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Point contact tunneling spectroscopy apparatus for large scale mapping of surface superconducting properties

In this paper, we describe the design and testing of a point contact tunneling spectroscopy device that can measure material surface superconducting properties (i.e., the superconducting gap Δ and the critical temperature T C ) and density of states over large surface areas with size up to mm 2 . The tip lateral (X,Y) motion, mounted on a (X,Y,Z) piezo-stage, was calibrated on a patterned substrate consisting of Nb lines sputtered on a gold film using both normal (Al) and superconducting (PbSn) tips at 1.5 K. The tip vertical (Z) motion control enables some adjustment of the tip-sample junction resistance that can be measured over 7 orders of magnitudes from a quasi-ohmic regime (few hundred Ω) to the tunnel regime (from tens of kΩ up to few GΩ). The low noise electronic and LabVIEW program interface are also presented. Finally, the point contact regime and the large-scale motion capabilities are of particular interest for mapping and testing the superconducting properties of macroscopic scale superconductor-based devices.