Search NASA⌕ Search

SEARCH · Search NASA

Results for “pixelated CdTe detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Characterization of a Pixelated Cadmium Telluride Detector System Using a Polychromatic X-Ray Source and Gold Nanoparticle-Loaded Phantoms for Benchtop X-Ray Fluorescence Imaging

In this paper, the imaging dose and scan time have been considered as the two major constraints for routine benchtop x-ray fluorescence computed tomography (XFCT) imaging. One way to address this issue is to acquire x-ray fluorescence (XRF) signals in parallel through a 2D array of single-crystal detectors or a pixelated detector along with the cone-beam x-ray source. To identify a detector system suitable for this purpose, a commercially available, fully spectroscopic cadmium telluride (CdTe) pixelated detector, HEXITEC (High-Energy X-ray Imaging Technology), was tested under the experimental conditions optimized for benchtop XFCT imaging of gold nanoparticles (GNPs). Specifically, two different parallel-hole stainless steel collimators were fabricated and coupled with the detector for seamless integration into our existing benchtop cone-beam XFCT system. After the detector deployment, this benchtop XFCT system was used to detect XRF photons from GNP-loaded phantoms. A pixel-merging algorithm was introduced to enhance the sensitivity of XRF photon detection thereby minimizing the scan time. The effect of pixel-level charge sharing correction algorithms was investigated within the context of benchtop XFCT imaging. The detector energy resolution, in terms of the full width at half maximum (FWHM) values at different gold K-shell XRF energies, was also determined. Of the two charge sharing correction algorithms examined, the charge sharing addition gave better sensitivity than the charge sharing discrimination (csd). On the other hand, under the current experimental conditions, the energy resolution of the HEXITEC detector was the best with the csd and estimated to be 1.56 keV FWHM at 66-69 keV photon energy. Overall, despite some degradation of the detector energy resolution (compared with typical single crystal CdTe detectors), the HEXITEC detector enabled parallel data acquisition under the experimental conditions typical of benchtop XFCT imaging and operated well within our benchtop XFCT setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SuperHERO: The Next Generation Hard X-ray HEROES Telescope

SuperHERO is a new high-sensitivity Long Duration Balloon (LDB)-capable, hard-x-ray (20-75 keV) telescope for making novel astrophysics and heliophysics observations. The proposed SuperHERO payload will be developed jointly by the Astrophysics Office at NASA Marshall Space Flight Center, the Solar Physics Laboratory and Wallops Flight Facility at NASA Goddard Space Flight Center. SuperHERO is a follow-on payload to the High Energy Replicated Optics to Explore the Sun (HEROES) balloon-borne telescope that recently launched from Fort Sumner, NM in September of 2013. The HEROES core instrument is a hard x-ray telescope consisting of x-ray 109 optics configured into 8 modules. Each module is aligned to a matching gas-filled detector at a focal length of 6 m. SuperHERO will make significant improvements to the HEROES payload, including: new solid-state multi-pixel CdTe detectors, additional optics, the Wallops Arc-Second Pointer, alignment monitoring systems and lighter gondola.

Gaskin, Jessica A.↗

SuperHERO: The Next Generation Hard X-Ray HEROES Telescope

SuperHERO is a new high-sensitivity Long Duration Balloon (LDB)-capable, hard-x-ray (20-75 keV) telescope for making novel astrophysics and heliophysics observations. The proposed SuperHERO payload will be developed jointly by the Astrophysics Office at NASA Marshall Space Flight Center, the Solar Physics Laboratory and Wallops Flight Facility at NASA Goddard Space Flight Center. SuperHERO is a follow-on payload to the High Energy Replicated Optics to Explore the Sun (HEROES) balloon-borne telescope that recently launched from Fort Sumner, NM in September of 2013. The HEROES core instrument is a hard x-ray telescope consisting of x-ray 109 optics configured into 8 modules. Each module is aligned to a matching gas-filled detector at a focal length of 6 m. SuperHERO will make significant improvements to the HEROES payload, including: new solid-state multi-pixel CdTe detectors, additional optics, the Wallops Arc-Second Pointer, alignment monitoring systems and lighter gondola.

Wilson-Hodge, Colleen A.↗

High dynamic range CdTe mixed-mode pixel array detector (MM-PAD) for kilohertz imaging of hard x-rays

A hard x-ray, high-speed, high dynamic range scientific x-ray imager is described. The imager is based on the mixed-mode pixel array detector (MM-PAD) readout chip coupled to a 750 µm thick cadmium telluride (CdTe) sensor. The full imager is a 2 × 3 tiled array of MM-PAD sensor/readout chip hybrids. CdTe improves detection for high energy x-rays as compared to silicon sensors, enabling efficient x-ray imaging to extend to >100 keV. The detector is capable of 1 kHz imaging and in-pixel circuitry has been designed to allow for well depths of greater than 4 × 10 6 80 keV x-rays. Here, a charge integrating front-end allows for quantitative measurement of high flux x-ray images beyond the capabilities of photon counting detectors. Detector performance is summarized and experimental measurements are presented.

99 GENERAL AND MISCELLANEOUS↗

Spatial calibration and synthetic diagnostic of a multi-energy hard x-ray camera at WEST tokamak

WEST (tungsten environment in steady-state tokamak) is starting operation for the first time with a water-cooled full tungsten divertor, enabling long pulse operation. Heating is provided by radiofrequency systems, including lower hybrid current drive (LHCD). In this context, a compact multi-energy hard x-ray camera has been installed for energy and space-resolved measurements of the electron temperature, the fast electron tail density produced by LHCD and runaway electrons, and the beam–target emission of tungsten at the target due to fast electron losses interacting with the divertor plates. The diagnostic is a pinhole camera based on a 2D pixel array detector (Pilatus 3 CdTe CMOS Hybrid-Pixel detector produced by DECTRIS). The novelty of this diagnostic technique is the detector’s capability of adjusting the threshold energy at pixel level. This innovation provides great flexibility in the energy configuration, allowing simultaneous space and energy-resolved x-ray measurements. This contribution details two important steps in the preparation of the diagnostic operation. First, the in-vessel spatial calibration that was carried out with a radioactive source. Second, the synthetic diagnostic is obtained by the suite of codes ALOHA/C3PO/LUKE/R5-X2, which simulates LH wave propagation and absorption, as well as the fast electron bremsstrahlung production.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Detector Characterization for Quantitative Spectral Radiography of Uranium Powder Samples

Pacific Northwest National Laboratory (PNNL) is developing a prototype spectral x-ray radiography (SpecX) non-destructive assay system for noninvasive material mass quantification of uranium-bearing powders. The SpecX system uses a custom material estimation algorithm, which requires a high-fidelity pixel-by-pixel detector response model for accurate quantification. We performed a detailed characterization and built a model of a High-Energy X-ray Imaging Technology (HEXITEC) CdTe pixelated spectral detector. Here we present the detector characterization which led to that model, including a determination of the pixel-wise energy calibration, the detection efficiency, the detector uniformity, the detector stability, and a comparison of methods to remove charge-shared events.

spectral X-ray radiography, pixelated detector, ca↗

Modeling and Measuring Charge-Sharing in Hard X-ray Imagers Using HEXITEC CdTe Detectors

The Rutherford Appleton Laboratory's HEXITEC ASIC has been designed to provide fine pixelated X-ray spectroscopic imaging in combination with a CdTe or CZT detector layer. Although HEXITEC's small pixels enable higher spatial resolution as well as higher spectral resolution via the small-pixel effect, they also increase the probability of charge sharing, a process which degrades spectral performance by dividing the charge induced by a single photon among multiple pixels. In this paper, we investigate the effect of this process on a continuum X-ray spectrum below the Cd and Te fluorescence energies (23 keV). This is done by comparing laboratory measurements with simulations performed with a custom designed model of the HEXITEC ASIC. We find that the simulations closely match the observations implying that we have an adequate understanding of both charge sharing and the HEXITEC ASIC itself. These results can be used to predict the distortion of a spectrum measured with HEXITEC and will help determine to what extent it can be corrected. They also show that models like this one are important tools in developing and interpreting observations from ASICs like HEXITEC.

Ryan, Daniel F.↗

CdTe Focal Plane Detector for Hard X-Ray Focusing Optics

The demand for higher resolution x-ray optics (a few arcseconds or better) in the areas of astrophysics and solar science has, in turn, driven the development of complementary detectors. These detectors should have fine pixels, necessary to appropriately oversample the optics at a given focal length, and an energy response also matched to that of the optics. Rutherford Appleton Laboratory have developed a 3-side buttable, 20 millimeter x 20 millimeter CdTe-based detector with 250 micrometer square pixels (80 x 80 pixels) which achieves 1 kiloelectronvolt FWHM (Full-Width Half-Maximum) @ 60 kiloelectronvolts and gives full spectroscopy between 5 kiloelectronvolts and 200 kiloelectronvolts. An added advantage of these detectors is that they have a full-frame readout rate of 10 kilohertz. Working with NASA Goddard Space Flight Center and Marshall Space Flight Center, 4 of these 1 millimeter-thick CdTe detectors are tiled into a 2 x 2 array for use at the focal plane of a balloon-borne hard-x-ray telescope, and a similar configuration could be suitable for astrophysics and solar space-based missions. This effort encompasses the fabrication and testing of flight-suitable front-end electronics and calibration of the assembled detector arrays. We explain the operation of the pixelated ASIC readout and measurements, front-end electronics development, preliminary X-ray imaging and spectral performance, and plans for full calibration of the detector assemblies. Work done in conjunction with the NASA Centers is funded through the NASA Science Mission Directorate Astrophysics Research and Analysis Program.

X-ray↗

Versatile multi-energy hard x-ray camera to study confined and unconfined fast electron dynamics and anisotropies (Invited)

A powerful and flexible hard x-ray (HXR) camera has been recently installed and tested on the WEST tokamak (CEA, France) in collaboration with the Princeton Plasma Physics Laboratory. The diagnostic is a pinhole camera fielded with a 2D pixel detector equipped with a 1 mm thick CdTe sensor. The novelty of this diagnostic technique is the detector’s capability of adjusting the threshold energy at the pixel level. This innovation provides great flexibility in the energy configuration, allowing simultaneous space, energy, and time resolved x-ray measurements. The novel camera has been used to measure the core radiation from non-Maxwellian (fast) electrons accelerated by Lower Hybrid (LH) waves and also the beam–target emission of tungsten in the divertor region produced by fast electron losses interacting with the target. In addition, anisotropic hard x-ray emission has been detected for the first time at the WEST core and edge plasma, with opposite toroidal intensity trends. Finally, experimental vertical and toroidal HXR profiles have been successfully reproduced with the LH code LUKE.

47 OTHER INSTRUMENTATION↗

SuperHERO: Design of a New Hard X-Ray Focusing Telescope

SuperHERO is a hard x-ray (20-75 keV) balloon-borne telescope, currently in its proposal phase, that will utilize high angular-resolution grazing-incidence optics, coupled to novel CdTe multi-pixel, fine-pitch (250 micrometers) detectors. The high-resolution electroformed-nickel, grazing-incidence optics were developed at MSFC, and the detectors were developed at the Rutherford Appleton Laboratory in the UK, and are being readied for flight at GSFC. SuperHERO will use two active pointing systems; one for carrying out astronomical observations and another for solar observations during the same flight. The telescope will reside on a light-weight, carbon-composite structure that will integrate the Wallops Arc Second Pointer into its frame, for arcsecond or better pointing. This configuration will allow for Long Duration Balloon flights that can last up to 4 weeks. This next generation design, which is based on the High Energy Replicated Optics (HERO) and HERO to Explore the Sun (HEROES) payloads, will be discussed, with emphasis on the core telescope components.

SuperHERO↗

The HEXITEC Hard X-Ray Pixelated CdTe Imager for Fast Solar Observations

There is an increasing demand in solar and astrophysics for high resolution X-ray spectroscopic imaging. Such observations would present ground breaking opportunities to study the poorly understood high energy processes in our solar system and beyond, such as solar flares, X-ray binaries, and active galactic nuclei. However, such observations require a new breed of solid state detectors sensitive to high energy X-rays with fine independent pixels to sub-sample the point spread function (PSF) of the X-ray optics. For solar observations in particular, they must also be capable of handling very high count rates as photon fluxes from solar flares often cause pile up and saturation in present generation detectors. The Rutherford Appleton Laboratory (RAL) has recently developed a new cadmium telluride (CdTe) detector system, called HEXITEC (High Energy X-ray Imaging Technology). It is an 80 x 80 array of 250 micron independent pixels sensitive in the 2-200 keV band and capable of a high full frame read out rate of 10 kHz. HEXITEC provides the smallest independently read out CdTe pixels currently available, and are well matched to the few arcsecond PSF produced by current and next generation hard X-ray focusing optics. NASA's Goddard and Marshall Space Flight Centers are collaborating with RAL to develop these detectors for use on future space borne hard X-ray focusing telescopes. We show the latest results on HEXITEC's imaging capability, energy resolution, high read out rate, and reveal it to be ideal for such future instruments.

Baumgartner, Wayne H.↗

Characterizing electron-collecting CdTe for use in a 77 ns burst-rate imager

The Keck-PAD (pixel array detector) was developed at Cornell as a burst-rate imager capable of recording images from successive electron bunches (153 ns period) from the Advanced Photon Source (APS). Both Si and hole-collecting Schottky CdTe have been successfully bonded to this ASIC (application-specific integrated circuit) and used with this frame rate. The facility upgrades at the APS will lower the bunch period to 77 ns, which will require modifications to the Keck-PAD electronics to image properly at this reduced period. In addition, operation at high X-ray energies will require a different sensor material having a shorter charge collection time. For the target energy of 40 keV for this project, simulations have shown that electron-collecting CdTe should allow >90% charge collection within 35 ns. This collection time will be sufficient to sample the signal from one frame and prepare for the next. 750 µm-thick electron-collecting Schottky CdTe has been obtained from Acrorad and bonded to two different charge-integrating ASICs developed at Cornell, the Keck-PAD and the CU-APS-PAD. Carrier mobility has been investigated using the detector response to single X-ray bunches at the Cornell High Energy Synchrotron Source and to a pulsed optical laser. The tests indicate that the collection time will meet the requirements for 77 ns imaging.

36 MATERIALS SCIENCE↗

The future of large format HgCdTe arrays for astronomy

Rockwell has developed the 256 x 256 Near Infrared Camera and Multi-Object Spectrometer 3 (NICMOS3) FPA for the Hubble Space Telescope under funding from NASA through the University of Arizona. Since 1989, dozens of science grade devices have been delivered to astronomers throughout the world for ground based infrared observations. These devices have excellent sensitivity at 77 K with mean dark currents of 0.1 e(-)/s, noise of 25 e(-), and quantum efficiency of 55-70%. Pixel yields as high as 99.9% have been achieved. Our present plans are to develop a 1024 x 1024 focal plane array (FPA) with 2.5 micron cutoff and make it available to astronomers. Such large arrays are made possible by the advances in detector material size (3 in. diameter producible alternative to CdTe for epitaxy (PACE-I) wafers), multiplexer advances (ability to verify the design in detail and availability of advanced foundries), and novel hybridization and reliability approaches.

Vural, K.↗

256 x 256 PACE-1 PV HgCdTe focal plane arrays for medium and short wavelength infrared applications

The development of two 256 by 256 hybrid HgCdTe focal plane array (FPA) families is described, and their performance is discussed. The hybrid FPAs employ a PV HgCdTe detector array and custom Si CMOS readouts. The PACE-1 process was used to fabricate the detectors, whereby the liquid phase epitaxial growth of HgCdTe occurs on sapphire substrates buffered by a layer of CdTe. The performance characteristics of the detector arrays are given. A tactical 256 by 256 CMOS readout is tested, in which a high functional yield was achieved. Updated test results are given for a 256 by 256 readout circuit developed for use in an orbital replacement instrument for the Hubble Space Telescope. The characterizations of several MWIR and SWIR FPAs were thorough and shown to be reliable. The pixel yield, maximum FPA responsivity nonuniformity, and SWIR FPA read noise for the tests are given. The high contrast and insignificant fixed pattern noise of the imagery from the MWIR 256 by 256 FPA are emphasized. These qualities were obtained when the device was operating at 80 k and utilizing f/2 optics with an 8-in. focal length and a 4.4 micron high pass filter.

Kozlowski, L. J.↗

Multi-energy calibration of a PILATUS3 CdTe detector for hard x-ray measurements of magnetically confined fusion plasmas

A multi-energy hard x-ray pin-hole camera based on the PILATUS3 X 100K-M CdTe detector has been developed at the Princeton Plasma Physics Laboratory for installation on the Tungsten Environment in Steady State Tokamak. This camera will be employed to study thermal plasma features such as electron temperature as well as non-thermal effects such as fast electron tails produced by a lower hybrid radiofrequency current drive and the birth of runaway electrons. The innovative aspect of the system lies in the possibility of setting the threshold energy independently for each of the ~100k pixels of the detector. This feature allows for the measurement of the x-ray emission in multiple energy ranges with adequate space and time resolution (~1 cm, 2 ms) and coarse energy resolution. In this work, the energy dependence of each pixel was calibrated within the range 15 keV–100 keV using a tungsten x-ray tube and emission from a variety of fluorescence targets (from yttrium to uranium). The data corresponding to pairs of K α emission lines are fit to the characteristic responsivity (“S-curve”), which describes the detector sensitivity across the 64 possible energy threshold values for each pixel; this novel capability is explored by fine-tuning the voltage of a six-bit digital-analog converter after the charge-sensitive amplifier for each of the ~100k pixels. Here, this work presents the results of the calibration including a statistical analysis. It was found that the achievable energy resolution is mainly limited by the width of the S-curve to 3 keV–10 keV for threshold energies up to 50 keV, and to ≥20 keV for energies above 60 keV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

CEPS - A Compact Electron-Proton Spectrometer

Small mass/power sensors are needed for autonomous Moon surface ops that provide alerts to impending adverse space weather conditions. In order to use current operational forecasting tools, a sensor capable of measuring both high-energy electrons and protons is needed. By combining high-TRL Timepix technology with a CdTe layer, this project leverages known technology to fill a critical gap for surface operations. The proposed work will bring ability to provide warnings to crews to shelter with a device that can easily be carried on the Lunar and Martian surfaces.

Radiation↗

Characterization of 128 × 128 MM-PAD-2.1 ASIC: a fast framing hard x-ray detector with high dynamic range

Here, we characterize a new x-ray Mixed-Mode Pixel Array Detector (MM-PAD-2.1) Application Specific Integrated Circuit (ASIC). Using an integrating pixel front-end with dynamic charge removal architecture, the MM-PAD-2.1 ASIC extends the maximum measurable x-ray signal (in 20 keV photon units) to > 10 7 x-rays/pixel/frame while maintaining a low read noise across the full dynamic range, all while imaging continuously at a frame rate of up to 10 kHz. The in-pixel dynamic charge removal mechanism prevents saturation of the input amplifier and proceeds in parallel with signal integration to achieve deadtime-less measurements with incident x-ray rates of > 10 10 x-rays/pixel/s. The ASIC format consists of 128 × 128 square pixels each 150 μm on a side and is designed to be 3-side buttable so large arrays can be effectively tiled. Here we use both laboratory x-ray sources and the Cornell High Energy Synchrotron Source (CHESS) to characterize two single ASIC prototype detectors for both low (single x-ray) and high incident flux detection. In the first detector the ASIC was solder bump-bonded to a 500 μm thick Si sensor for efficient detection of x-rays below 20 keV, whereas the second detector used a 750 μm thick CdTe sensor for x-rays above ~20 keV.

36 MATERIALS SCIENCE↗