Search NASA⌕ Search

SEARCH · Search NASA

Results for “plant effluent”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Hanford Waste Treatment Plant Effluent Management Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant Effluent Management facility (EMF) stack monitor location was qualified using the LV-S1 scale model stack as a baseline, augmented by the LB-S1 and LV-S2 scale model stacks to address the Direct Feed Low Activity Waste Effluent Management Facility Vessel Vent Process (DVP) injection into the main Active Confinement Ventilation (ACV) system duct. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale models and its sampling locations were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the EMF stack was performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of stack flow rates for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on the LV-S1 scale model test DV values, the corresponding stack flow rates for the EMF stack are as listed in Table S1. Table S1. Effluent Management Facility Stack Qualified Flow Range. Stack Parameter EM-1 Minimum Qualified Stack Flow (scfm) 781 Maximum Qualified Stack Flow (scfm) 53,432 The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack test at the EMF. Flow angle results were less than 5°; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition ranged between 2.2% COV and 4.3% COV, which were all within the range of the target % COV values from the scale model tests on the LV-S1, LB-S1, and LV S2 scale models. Based on these stack verification test results, the EMF filtered exhaust stack sampling location meets the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes each combination of ACV fan with the DVP exhausters. Further changes to the system configuration or operating conditions that are outside the qualified flow rates described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Waste Treatment Plant Effluent Management Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant Effluent Management Facility (EMF) stack monitor location was qualified using a combination of scale model stacks to mitigate the risk of identifying that the sampling location does not meet the qualification criteria on the full-scale stack. The LV-S1 scale model stack was used as a baseline, augmented by the LB-S1 and LV-S2 scale model stacks to address the Direct Feed Low Activity Waste Effluent Management Facility Vessel Vent Process (DVP) injection into the main Active Confinement Ventilation (ACV) system duct. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling locations were geometrically similar to the actual stack, and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. The LV-S1, LB-S1, and LV-S2 scale model stack tests have met the criteria of the ANSI/HPS N13.1-1999 standard to demonstrate the stack sampling locations are well mixed. Verification tests of the EMF stack were performed at normal operating conditions. The minimum 1/6 DV value and the maximum 6 DV value from the scale model testing determine the range of stack flow rates for which the full-scale stack may be operated while remaining in compliance with the stack verification criterion. A practical range for the full-scale stack qualification uses the average DV through 6 DV from the scale model tests to compute the corresponding flow rates. Table S1 lists the operating flow rate along with the average and maximum qualified stack flow rate based on the LV-S1 scale model DV values. The operating flow is below the maximum qualified stack flow, which means that the scale model test results are acceptable for stack qualification. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be ≤20°. Second, the velocity uniformity at the full-scale stack must be ≤20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack test at the EMF. Flow angle results were <5°; all flow angle results were within the ≤20° criterion. The velocity uniformity results for each test condition ranged between 2.2% COV and 4.3% COV, all of which were within the range of the target % COV values from the scale model tests on the LV-S1, LB-S1, and LV S2 scale models. Based on these stack verification test results, the EMF filtered exhaust stack sampling location meets the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all planned fan operating configurations. This includes each combination of ACV fans with DVP exhausters. Further changes to the system configuration or operating conditions that are outside the qualified flow rates described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Subsurface injection of combustion power plant effluent as a solid-phase carbon dioxide storage strategy

Long-term geological storage of CO 2 may be essential for greenhouse gas mitigation, so a number of storage strategies have been developed that utilize a variety of physical processes. Recent work shows that injection of combustion power plant effluent, a mixture of CO 2 and N 2 , into CH 4 hydrate-bearing reservoirs blends CO 2 storage with simultaneous CH 4 production where the CO 2 is stored in hydrate, an immobile, solid compound. This strategy creates economic value from the CH 4 production, reduces the preinjection complexity since costly CO 2 distillation is circumvented, and limits leakage since hydrate is immobile. In this work, we explore the phase behavior of these types of injections and describe the individual roles of H 2 O, CO 2 , CH 4 , and N 2 as these components partition into aqueous, vapor, hydrate, and liquid CO 2 phases. Our results show that CO 2 storage in subpermafrost or submarine hydrate-forming reservoirs requires coinjection of N 2 to maintain two-phase flow and limit plugging.

58 GEOSCIENCES↗

Coal Fired Power Plant Configuration and Operation Impact on Plant Effluent Contaminants and Conditions

The primary objective of this project is to characterize coal contaminants in coal-fired power plant wastewater as a function of coal type, unit configurations, and unit operation profile with uncertainty analysis. This project was in response to the U.S. Department of Energy (DOE) Solicitation DE-FOA-0001842. The project duration was between September 01, 2018, and December 31, 2021 (no-cost extension filed, due to the Covid-19 pandemic restrictions, and approved). Field and lab test program was conducted with the main goal to characterize coal contaminants in coal-fired power plant wastewater as a function of coal type, unit configurations, and unit operation profile with uncertainty analysis. In this project, the team of Lehigh University (prime recipient) and Western Kentucky University identified two suitable Thermoelectric Power Plants (TTPs) firing bituminous and sub-bituminous coals respectively, designed test plans, and performed sample collection. Sampling included coal from each TTPs power generation units, Wet Flue Gas Desulfurization (WFGD) slurry material and waste-water samples taken from the outlet of the water treatment tank prior to discharge and other pertinent locations. Coal samples are dried, crushed, and pulverized according to the American Society for Testing and Materials (ASTM) methods. The prepared coal samples are analyzed for normal proximate and ultimate analysis tests in addition to the toxic metals and anions according to ASTM methods. The FGD slurry materials are analyzed for toxic metals and anions according to Electric Power Research Institute (EPRI) or Environmental Protection Agency (EPA) methods, as appropriate. The wastewater samples from the water treatment tank outlet are analyzed for toxic metals and anions according to EPA methods. The effluent species analyzed include mercury, arsenic, selenium, nitrate/nitrite, bromide, and chlorine. This project provided results of effluent conditions as a function of coal type, unit configuration, and unit operation profile, and identified the levels of uncertainty in the effluent results.

01 COAL, LIGNITE, AND PEAT↗

Measurement techniques for trace metals in coal-plant effluents: A brief review

The strong features and limitations of techniques for determining trace elements in aerosols emitted from coal plants are discussed. Techniques reviewed include atomic absorption spectroscopy, charged particle scattering and activation, instrumental neutron activation analysis, gas/liquid chromatography, gas chromatographic/mass spectrometric methods, X-ray fluorescence, and charged-particle-induced X-ray emission. The latter two methods are emphasized. They provide simultaneous, sensitive multielement analyses and lend themselves readily to depth profiling. It is recommended that whenever feasible, two or more complementary techniques should be used for analyzing environmental samples.

Singh, J. J.↗

Rapid, single-step most-probable-number method for enumerating fecal coliforms in effluents from sewage treatment plants

A single-step most-probable-number method for determining the number of fecal coliform bacteria present in sewage treatment plant effluents is discussed. A single growth medium based on that of Reasoner et al. (1976) and consisting of 5.0 gr. proteose peptone, 3.0 gr. yeast extract, 10.0 gr. lactose, 7.5 gr. NaCl, 0.2 gr. sodium lauryl sulfate, and 0.1 gr. sodium desoxycholate per liter is used. The pH is adjusted to 6.5, and samples are incubated at 44.5 deg C. Bacterial growth is detected either by measuring the increase with time in the electrical impedance ratio between the innoculated sample vial and an uninnoculated reference vial or by visual examination for turbidity. Results obtained by the single-step method for chlorinated and unchlorinated effluent samples are in excellent agreement with those obtained by the standard method. It is suggested that in automated treatment plants impedance ratio data could be automatically matched by computer programs with the appropriate dilution factors and most probable number tables already in the computer memory, with the corresponding result displayed as fecal coliforms per 100 ml of effluent.

Munoz, E. F.↗

Thermal mapping, geothermal source location, natural effluents and plant stress in the Mediterranean coast of Spain

Although no significant results were achieved during the report period, research continues. A sample of imagery showing thermal inertia and temperature differences over the northeastern United States and Europe was received. The project coordinator attended a TELLUS Project meeting in Ispra, Italy at which general guidelines for the future were established and the quality of the data received was discussed.

Delascuevas, R. N.↗

Thermal mapping, geothermal source location, natural effluents and plant stress in the Mediterranean coast of Spain

Data obtained by HCMM satellite over a complex area in eastern Spain were evaluated and found to be most useful in studying macrostructures in geology and in analyzing marine currents, layers, and areas (although other satellites provide more data). The upper scale to work with HCMM data appears to be 1:2.000.000. Techniques used in preprocessing, processing, and analyzing imagery are discussed as well as methods for pattern recognition. Surface temperatures obtained for soils, farmlands, forests, geological structures, and coastal waters are discussed. Suggestions are included for improvements needed to achieve better results in geographic areas similar to the study area.

Delascuevas, R. N.↗

Study on Gaseous and Liquid Radioactive Effluents in AP1000 Plants

During normal operation, the gaseous and liquid radioactive effluents will be released in nuclear plants. It is the base of effluents management and environment influence evaluation to analyze the anticipated annual activity releases. In China, both the annual release of radioactive liquid and gaseous effluents limit value (for single plant and whole-site) and the liquid concentration of discharge canal are introduced in GB6249-2011. This standard is mandatory and the limit values must be met. Because the limit values are very strict, it is meaningful to determine a suitable and logical method of liquid and gaseous effluents in China. In this paper, according to the operation actuality and related rules of law in China, the analysis method of nuclides except H-3 and C-14 in the gaseous and liquid effluents of AP1000 plant is introduced. The method and results can be reference for effluents analysis for AP1000 plants. According to the revised method, the gaseous and liquid radioactive effluents for Sanmen 1 and 2 plants are calculated. The results and the comparison with the limit value in GB6249-2011 are given. The liquid concentration of discharge canal is 868.4 Bq/l, which is less than the limit value 1000 Bq/L in GB6249-2011. It can be seen that according to the revised method, the gaseous and liquid radioactive effluents for Sanmen 1 and 2 plants can meet the limit value in GB6249-2011. This revised method considers all the source, the detailed purification process and release pathways for gaseous and liquid radioactive effluents. The effluents calculation in the revised method can be a possible reference to the analysis of the gaseous and liquid radioactive effluents in China, though there may be some detailed optimization and improvement in future. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Decomposition of Select Volatile Organic Compounds by Caustic Hydrolysis for Effluent Management Facility (Rev. 0)

Hydrolysis is a proposed treatment method for organic constituents at the Effluent Management Facility during the Direct-Feed Low-Activity Waste process at the Waste Treatment and Immobilization Plant. Four compounds, acetonitrile, acrylonitrile, acetone, and methylene chloride, comprise a significant portion of the organic constituents identified in the Waste Treatment and Immobilization Plant Effluent Composition Estimate. In support of the Direct-Feed Low-Activity Waste process, the Washington River Protection Solutions Organic Studies Group at the 222-S Laboratory completed a laboratory test of caustic hydrolysis reactions of these four compounds.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Municipal wastewater affects adipose deposition in male mice and increases 3T3-L1 cell differentiation

Trace concentration of EDs (endocrine disrupting compounds) in water bodies caused by wastewater treatment plant effluents is a recognized problem for the health of aquatic organisms and their potential to affect human health. In this paper we show that continuous exposure of male mice from early development to the adult life (140 days) to unrestricted drinking of wastewater collected from a municipal sewage treatment plant, is associated with an increased adipose deposition and weight gain during adulthood because of altered body homeostasis. In parallel, bisphenol A (BPA) at the administration dose of 5 μg/kg/body weight, shows an increasing effect on total body weight and fat mass. In vitro, a solid phase extract (SPE) of the wastewater (eTW), caused stimulation of 3T3-L1 adipocyte differentiation at dilutions of 0.4 and 1 % in the final culture medium which contained a concentration of BPA of 40 nM and 90 nM respectively. Pure BPA also promoted adipocytes differentiation at the concentration of 50 and 80 μM. BPA effect in 3T3-L1 cells was associated to the specific activation of the estrogen receptor alpha (ERα) in undifferentiated cells and the estrogen receptor beta (ERβ) in differentiated cells. BPA also activated the Peroxisome Proliferator Activated Receptor gamma (PPARγ) upregulating a minimal 3XPPARE luciferase reporter and the PPARγ-target promoter of the aP2 gene in adipose cells, while it was not effective in preadipocytes. The pure estrogen receptor agonist diethylstilbestrol (DES) played an opposite action to that of BPA inhibiting PPARγ activity in adipocytes, preventing cell differentiation, activating ERα in preadipocytes and inhibiting ERα and ERβ regulation in adipocytes. The results of this work show that the drinking of chemically-contaminated wastewater promotes fat deposition in male mice and that EDs present in sewage are likely responsible for this effect through a nuclear receptor-mediated mechanism. - Highlights: • Sewage watewaters (TW) sampled from a Municipal Treatment Sewage Plant are biologically active in mice and in vitro. • In male mice TW promotes an increase in adipose mass deposition following exposure from foetal to adult life. A similar effect is produced by BPA. • The expression of key genes of the adipose metabolism is increased in epidydimal fat both by TW and BPA. • An extract from the TW which concentrated the contained chemicals by a factor of 1000, is able to stimulate 3T3-L1 adipocyte differentiation. • The major chemicals contained in the TW, bisphenol A and nonylphenol, are able to promote adipocyte differentiation at the low environmentally relevant doses as are found in the TW.

60 APPLIED LIFE SCIENCES↗

Performance Criteria for Capture and/or Immobilization Technologies (Revision 1)

The capture and subsequent immobilization of regulated volatile radionuclides from the off-gas streams of a used nuclear fuel (UNF) reprocessing facility has been a topic of substantial research interest for the US Department of Energy and its international counterparts. Removal of specific radionuclides from the plant effluent streams before discharge to the environment is required to meet regulations set forth by the US Environmental Protection Agency. Upon removal, the radionuclides, as well as associated sorbents that cannot be regenerated in a cost-effective manner, are destined for conversion to a waste form. Research in separation and capture methodologies has included a wide range of technology types, and studies of waste forms are correspondingly diverse. In considering the future development and implementation of both sorbents and waste forms, it is necessary to identify benchmark measures of performance to objectively evaluate each sorbent system or waste form. Sets of performance criteria and associated metrics have been developed for sorbent and waste form evaluation. These criteria address physical, radiological, and chemical characteristics, technical practicality, technical maturity, cost, and, for sorbents, system performance. The criteria and metrics appear to be robust and should be applicable despite the eventual waste classification (as either high- or low-level waste). They are flexible enough to address both aqueous reprocessing and electrochemical reprocessing of UNF. These criteria sets can serve as tools to evaluate performance at multiple stages within the development process, and in this revision (Revision 1) they have been used to assess technologies relating to krypton/xenon separations and iodine capture from off-gas streams arising from UNF reprocessing. Assessment of krypton/xenon separations using engineered forms of two zeolite minerals (silver mordenite and hydrogen mordenite in a polyacrylonitrile-based binder [AgZ-PAN/HZ-PAN]) found that the zeolite-based separation is relatively advanced in its development, but several key issues require resolution. First, desorption processes for both krypton and xenon require refinement to provide an understanding of the product purity that can be achieved. Second, adsorption rate data is needed in order to calculate the bed depth required for effective separation. Finally, it is strongly recommended that a technical review of krypton/xenon separation by AgZ-PAN/HZ-PAN be performed to synergize available data and assess the cost savings and operational benefits that may be realized from implementation of this technology. Assessment of metal organic frameworks (MOFs) for their use in the separation of krypton/xenon found that the ideal separation would be performed using a single-column system with a MOF selective for krypton over xenon. A robust research effort should work to identify a krypton-selective MOF designed to operate at temperatures of approximately 0°C or higher, which could be preferred over cryogenic krypton/xenon capture for used fuel reprocessing off-gas streams. In the case of the CaSDB-MOF (the most well-understood xenon sorbent to date), two issues are judged of high importance. First, xenon breakthrough capacity for the CaSDB-MOF in prototypical conditions should be determined. Preliminary research indicates that breakthrough may be near immediate, presenting a substantial obstacle in separative system design. Second, development of desorption methodology should be performed to determine regeneration time, energy requirements, and the product stream composition. Silver-based sorbents (AgZ and AgAero) for use in iodine capture from the dissolver off-gas were evaluated against the established criteria. These sorbents are significantly better understood for this application as a result of research efforts over the past decade. The potential implementation of AgAero at a large scale is hindered by its physical degradation by components of the dissolver off-gas stream. Less is known about the adsorption of iodine by these sorbents from other off-gas streams in the plant. Initial experimental efforts have been closely coordinated in an effort to understand organic iodine (such as would be found in the vessel off-gas) adsorption by AgZ and AgAero. Future work should expand this experimental program, and analysis of other reprocessing facility off-gas streams such as the vitrification off-gas stream should be conducted to better understand other potential applications for iodine sorbents. A review of iodine waste form development shows that this area is diverse and that multiple promising waste forms have been identified for the immobilization of radioactive iodine. Efforts related to the direct conversion of iodine sorbents (including AgZ and AgAero) should be continued because of the advantages of direct conversion in a waste management strategy and other sorbents should continue to be advanced as merited.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗