Ion beam and plasma methods of producing diamondlike carbon films

A variety of plasma and ion beam techniques was employed to generate diamondlike carbon films. These methods included the use of RF sputtering, dc glow discharge, vacuum arc, plasma gun, ion beam sputtering, and both single and dual ion beam deposition. Since films were generated using a wide variety of techniques, the physico-chemical properties of these films varied considerably. In general, these films had characteristics that were desirable in a number of applications. For example, the films generated using both single and dual ion beam systems were evaluated for applications including power electronics as insulated gates and protective coatings on transmitting windows. These films were impervious to reagents which dissolve graphitic and polymeric carbon structures. Nuclear reaction and combustion analysis indicated hydrogen to carbon ratios to be 1.00, which allowed the films to have good transmittance not only in the infrared, but also in the visible. Other evaluated properties of these films include band gap, resistivity, adherence, density, microhardness, and intrinsic stress. The results of these studies and those of the other techniques for depositing diamondlike carbon films are presented.

Swec, Diane M.↗

Coaxial microwave electrothermal thruster performance in hydrogen

The microwave electro thermal thruster (MET) is an electric propulsion concept that offers the promise of high performance combined with a long lifetime. A unique feature of this electric propulsion concept is its ability to create a microwave plasma discharge separated or floating away from any electrodes or enclosing walls. This allows propellant temperatures that are higher than those in resistojets and reduces electrode and wall erosion. It has been demonstrated that microwave energy is coupled into discharges very efficiently at high input power levels. As a result of these advantages, the MET concept has been identified as a future high power electric propulsion possibility. Recently, two additional improvements have been made to the coaxial MET. The first was concerned with improving the microwave matching. Previous experiments were conducted with 10-30 percent reflected power when incident power was in excess of 600 W(exp 6). Power was reflected back to the generator because the impedance of the MET did not match the 50 ohm impedance of the microwave circuit. To solve this problem, a double stub tuning system has been inserted between the MET and the microwave power supply. The addition of the double stub tuners reduces the reflected power below 1 percent. The other improvement has prepared the coaxial MET for hydrogen experiments. To operate with hydrogen, the vacuum window which separates the coaxial line from the discharge chamber has been changed from teflon to boron nitride. All the microwave energy delivered to the plasma discharge passes through this vacuum window. This material change had caused problems in the past because of the increased microwave reflection coefficients associated with the electrical properties of boron nitride. However, by making the boron nitride window electrically one-half of a wavelength long, power reflection in the window has been eliminated. This technical note summarizes the experimental performance of the improved coaxial MET when operating in nitrogen, helium, and hydrogen gases.

Richardson, W.↗

Electrostatic wave observation during a space simulation beam-plasma discharge

ELF waves which were observed during beam-plasma discharge in the large vacuum chamber at Johnson Space Center are studied. Phase delays as a function of radius (obtained from cross-correlation measurements of density fluctuations) along with measurements of frequency and plasma potential, density, and temperature have been compared to a zero-order slab model of nonlocal azimuthal drift wave propagation. The inferred wave phase velocity in the plasma frame after Doppler correction is found to be near one half the electron diamagnetic drift velocity. Although the measurements presented do not uniquely define a propagation mode, a model of azimuthal drift wave propagation is found to be consistent with observations.

Walker, D. N.↗

Absorption of a laser light pulse in a dense plasma.

An experimental study of the absorption of a laser light pulse in a transient, high-density, high-temperature plasma is presented. The plasma is generated around a metallic anode tip by a fast capacitive discharge occurring in vacuum. The amount of transmitted light is measured for plasmas made of different metallic ions in the regions of the discharge of high electronic density. Variation of the transmission during the laser pulse is also recorded. Plasma electrons are considered responsible for the very high absorption observed.

Mehlman-Balloffet, G.↗

TSS-1R Failure Mode Evaluation

Soon after the break of the tether during the Tethered Satellite System (TSS-1R) mission in February, 1996, a Tiger Team was assembled at the George C. Marshall Space Flight Center to determine the tether failure mode. One possible failure scenario was the Kevlar' strength member of the tether failed because of degradation due to electrical discharge or electrical arcing. During the next several weeks, extensive electrical discharge testing in low vacuum and plasma environments was conducted in an attempt to reproduce the electrical activity recorded by on-board science instruments during the mission. The results of these tests are presented in this paper.

Vaughn, Jason A.↗

Arcing in Leo and Geo Simulated Environments: Comparative Analysis

Comprehensive tests of two solar array samples in simulated Low Earth Orbit (LEO) and Geosynchronous Orbit (GEO) environments have demonstrated that the arc inception voltage was 2-3 times lower in the LEO plasma than in the GEO vacuum. Arc current pulse wave forms are also essentially different in these environments. Moreover, the wide variations of pulse forms do not allow introducing the definition of a "standard arc wave form" even in GEO conditions. Visual inspection of the samples after testing in a GEO environment revealed considerable damage on coverglass surfaces and interconnects. These harmful consequences can be explained by the discharge energy being one order of magnitude higher in vacuum than in background plasma. The tests also revealed a potential danger of powerful electrostatic discharges that could be initiated on the solar array surface of a satellite in GEO during the ignition of an arcjet thruster.

Vayner, Boris V.↗

RF wave observations in beam-plasma discharge

The Beam Plasma Discharge (BPD) was produced in the large vacuum chamber at Johnson Space Center (20 x 30 m) using an energetic electron beam of moderately high perveance. A more complete expression of the threshold current I sub c taking into account the pitch angle injection dependence is given. Ambient plasma density inferred from wave measurements under various beam conditions are reported. Maximum frequency of the excited RF band behaves differently than the frequency of the peak amplitude. The latter shows signs of parabolic saturation consistent with the light data. Beam plasma state (pre-BPD or BPD) does not affect the pitch angle dependence. Unexpected strong modulation of the RF spectrum at half odd integer of the electron cyclotron frequency (n + 1/2)f sub ce is reported (5 n 10). Another new feature, the presence of wave emission around 3/2 f sub ce for I sub b is approximate I sub c is reported.

Bernstein, W.↗

Hollow-Cathode Source Generates Plasma

Device generates argon, krypton, or xenon plasma via thermionic emission and electrical discharge within hollow cathode and ejects plasma into surrounding vacuum. Goes from cold start up to full operation in less than 5 s after initial application of power. Exposed to moist air between operations without significant degradation of starting and running characteristics. Plasma generated by electrical discharge in cathode barrel sustained and aided by thermionic emission from emitter tube. Emitter tube does not depend on rare-earth oxides, making it vulnerable to contamination by exposure to atmosphere. Device modified for use as source of plasma in laboratory experiments or industrial processes.

Deininger, W. D.↗

Space plasma laboratory - Experiment in simulated ionospheric plasma

Several experiments with simulated ionospheric plasma were performed in the Johnson Space Center's large (17 m diameter x 27 m height) vacuum chamber. Two of these, the RF discharge and the electron-beam plasma discharge, are described here. The RF experiment involved measurement of the loading on a 5 m dipole and a 5 m loop antenna caused by the presence of a plasma. The results indicate that when the RF frequency is near the electron gyro frequency a self-sustained plasma discharge is set up and the real part of the complex antenna impedance increases. The beam-plasma experiment was carried out to study a discharge produced by an electron beam with an energy of about 1 keV when the electron beam was injected parallel to the ambient magnetic field. As the beam current was raised to a critical level, a spontaneous transition occurred whereby a luminous halo was formed around the electron beam indicating a sustained discharge.

Konradi, A.↗

Optical observations of the beam-plasma discharge phenomenon

Spectroscopic observations of optical emissions from the beam-plasma discharge (BPD) phenomenon were made with NASA's vacuum chamber facility, at the Johnson Space Center, configured to simulate the physical conditions of magnetospheric electron beam injection into the ionospheric/upper-atmospheric environment. Nonlinear N2 and N2(+) optical emission growth rates (with respect to incremental electron beam current values) were observed from the chamber gas during transition to the BPD state. For electron-beam currents (I) near the BPD transition value (I(sub c)), the band emissions from the chamber gas produced by relatively low energy (less than or equal to 50 eV) electrons interacting with N2 were anomalously more intense than those requiring higher energy (greater than 100 eV) electrons to excite them. For I more greater than I(sub c), the optical emissions increased linearly with I (as was the case for I less than I(sub c)) and their ratios decreased significantly from the peak values attained when I approximately equals I(sub c). These observations suggest that during BPD some of the energy of the primary electron beam is efficiently transferred, via wave-particle interactions, to local electrons produced through ionization of the chamber gas; the resulting suprathermal electrons provide an additional source of excitation for the relatively low energy states (A, B and C) of N2. Such nonlinear excitation of upper atmospheric gas may occur in certain auroral events wherein the current due to the precipitating electrons approaches a value close to I(sub c).

Sivjee, G. G.↗

Development of a short pulsed solid propellant plasma thruster

The experimental results are summarized that were obtained in the development of a Teflon solid propellant pulsed plasma thruster. The feasibility was established of storing and feeding solid propellant in the form of an open circular loop into an operational thruster. This technique was verified to be practical by feeding over 20 inches of Teflon into a micro-thruster over an accumulated life test of 1858 hours. High energy density capacitors were evaluated under vacuum conditions when the capacitor is coupled directly to a plasma thruster. Numerous early capacitor failures were encountered. It was concluded that essentially all of the failures encountered in a vacuum environment are due to an internal electrical breakdown that will occur inside a capacitor that is not truly hermetically sealed. A steady input power significantly in excess of 130 watts can safely be tolerated if heat conduction can be provided to a sink whose temperature is about 16 C. A vacuum life test of the capacitor bank was carried out while discharging into a milli-lb. (milli-Newton) type pulsed plasma thruster. More than 1500 hours of vacuum testing of this milli-Newton type system has been accumulated without any capacitor problems. Recommendations are made for future capacitor designs.

Guman, W. J.↗

Suprathermal electrons produced by beam-plasma-discharge

Experiments conducted with a low energy plasma lens, HARP, in the electron beam of the large vacuum chamber at Johnson Space Center indicate that an enhanced population of 50 to 300 volt electrons appear when the beam goes into the Beam-Plasma Discharge (BPD) mode. Below the BPD instability the electron distribution appears to be characterized as non-energized single particle scattering and energy loss. At 100 cm from the beam core in the BPD mode the fluxes parallel to the beam are reduced by a factor of 20 with respect to the fluxes at 25 cm. Some evidence for isotropy near the beam core is presented.

Sharp, W. E.↗

Can a Penning ionization discharge simulate the tokamak scrape-off plasma conditions?

The tokamak scrape-off (the region between the vacuum vessel wall and the magnetically confined fusion plasma edge), represents a source/sink for the hot fusion plasma. The electron densities and temperatures are in the ranges 10 to the 11th - 10 to the 13th/cu cm and 1-40 eV, respectively (depending on the size, magnetic field intensity and configuration, plasma current, etc). In the work reported, the electron temperature and density have been estimated in a Penning ionization discharge by comparing its spectroscopic emission in the VUV with that predicted by a collisional radiative model. An attempt to directly compare this emission with that of the tokamak edge is briefly described.

Finkenthal, M.↗

Environmental Testing of the HERMeS TDU-2 Hall Thruster

The Hall Effect Rocket with Magnetic Shielding (HERMeS) is a 12.5 kW magnetically shielded Hall thruster presently under development for deep-space missions. A development model HERMeS thruster, TDU-2, with borosilicate channel walls, has successfully undergone proto-qualification testing including random vibration and thermal-vacuum, demonstrating the thruster can survive critical launch and operational environmental requirements. The three-axis random vibrational tests were performed with the thruster body mounted directly to the shaker table using a modified loading schedule to compensate for the vibration isolation dampers under design for the flight thruster. Initial random vibration testing revealed issues with fragmentation of magnetic coil potting material and thruster spool mount fabrication weaknesses that were addressed with an alternate potting material and fabrication revisions that were then successfully retested with an additional round of random vibration tests. Thermal-vacuum testing involved three cycles of full-power 600 V 12.5 kW thruster operation from -121°C to +373°C which included eight hours at peak temperature as well as a hot restart. A thermal model of the test configuration was developed and validated with the experiment results within an average difference of 5°C. Before and after the random vibrational and thermal-vacuum tests, the thruster performance, plasma plume, thrust vector angle, discharge characteristics, and magnetic field profile were measured. The thruster performance, magnetic field, and most other parameters remained invariant throughout the environmental testing campaign. During the thermal testing, an increase in the discharge oscillation amplitude of 11% was observed as well as subtle thrust vector changes of ±0.2° as the thruster warmed from -121°C to +373°C.

Sorenson, Ryan↗

Studies of beam plasma interactions in a space simulation chamber using prototype Space Shuttle instruments

In March, 1981, electron beam experiments were conducted in a large space simulation chamber using equipment destined to be flown aboard NASA's Office of Space Science-1 pallet (OSS-1). Two major flight experiments were involved. They include the Vehicle Charging and Potential (VCAP) experiment and the Plasma Diagnostics Package (PDP). Apparatus connected with VCAP included a Fast Pulse Electron Gun (FPEG), and a Charge and Current Probe (CCP). A preliminary view is provided of the results obtained when the electron emissions were held steady over relatively long periods of time such that steady state conditions could be obtained with respect to the electron beam interaction with the neutral gases and plasma of the vacuum chamber. Of particular interest was the plasma instability feature known as the Beam Plasma Discharge. For the present experiments the FPEG was used in a dc mode with a range of currents of 2 to 80 mA at a beam energy of 970 eV. Attention is given to the emissions of VLF and HF noise associated with the dc beam.

Banks, P. M.↗

Beam-generated waves in a large plasma chamber

The beam plasma discharge (BPD) and pre-BPD states of plasma waves generated in a large vacuum chamber by an electron beam of energy 0.5-2 keV are measured, and three wave categories are found. The low-frequency waves are suggested to be surface waves on a nonneutral plasma column, with measured properties consistent with the lower hybrid drift instability. The whistler mode spectrum is thought to be a Cerenkov resonance with the lower Trivelpiece-Gould mode, and it may not play an important role in modifying the particle distributions. The high frequency spectrum is seen to be a Cerenkov resonance with the upper Trivelpiece-Gould mode, and it is responsible for the major perturbation of the BPD beam energy.

Kellogg, Paul J.↗

A theoretical analysis of vacuum arc thruster performance

In vacuum arc discharges the current is conducted through vapor evaporated from the cathode surface. In these devices very dense, highly ionized plasmas can be created from any metallic or conducting solid used as the cathode. This paper describes theoretical models of performance for several thruster configurations which use vacuum arc plasma sources. This analysis suggests that thrusters using vacuum arc sources can be operated efficiently with a range of propellant options that gives great flexibility in specific impulse. In addition, the efficiency of plasma production in these devices appears to be largely independent of scale because the metal vapor is ionized within a few microns of the cathode electron emission sites, so this approach is well-suited for micropropulsion.

thruster↗