At least 19 records

Categorizing Plug Load Solutions by Ease of Implementation

Plug loads account for a growing share of U.S. commercial building electricity use, projected to rise from 16% today to 21% by 2050. Managing these loads presents a substantial opportunity for reducing energy costs while providing additional operational benefits, such as improved asset management and occupant comfort. Despite their potential, plug loads are numerous, diverse, and highly occupant-dependent, making control challenging. This publication organizes plug load control strategies by level of effort, offering building owners and operators a staged approach to implement interventions ranging from smart outlets and automatic receptacle controls to behavioral strategies. By following these actionable steps, building stakeholders can reduce energy consumption, lower utility bills, and realize broader operational advantages.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Plug Load Management Through Occupant Engagement at Washington State University

To decrease costs and improve building occupant safety, Washington State University (WSU) began planning a plug load management campaign in 2020, with implementation beginning in 2021. This case study describes the campaign's goals, approach, and results over the past 5 years, ultimately showing that occupant- and behavior-focused strategies can meaningfully reduce plug load energy use while improving health and safety.

29 ENERGY PLANNING, POLICY, AND ECONOMY

Project Report: School Retrofit Demonstration of Lighting and Outlet Controls with LED Upgrades

A technology demonstration project funded by the U.S. Department of Energy (DOE) was hosted by Boston Public Schools (BPS). This project evaluated wireless controls technology for lighting systems and plug loads (energy consumed by devices plugged into electrical outlets), implemented along with LED lighting retrofits in two classrooms. This study assesses technology readiness and effectiveness to determine the deployment potential of the technology in schools.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Low-Cost Identification and Monitoring of Diverse MELs in Residential and Commercial Buildings with PowerBlade (Final Technical Report)

This report describes our progress in developing a scalable wireless metering system that integrates plug-load energy meters that measure real, reactive, and apparent power along with load monitoring based on extracting high-fidelity electrical waveform features collected at every load to capture power profiles and automatically identify and categorize MELs, and make this technology available to the research, commercial, and government sectors.

47 OTHER INSTRUMENTATION

Oversizing and Part-Load Problems

Oversizing, the common engineering practice of specifying devices with capacity exceeding the actual load requirement, is a widespread practice across virtually all building technologies end-use categories, including HVAC, electrical systems, lighting, appliances, and plug loads. This practice, driven by factors like design uncertainty, institutional pressures, and risk aversion, results in wasted capital investment, control difficulties, and excessive energy consumption due to inefficient part-load operation. Part-load operation, where devices run below maximum capacity, is the dominant operating mode in most energy systems and presents a complex design challenge. Solutions to match output to load fall into three broad categories: constraining the output, adjusting the device’s internal behavior, and linking output to energy storage or other waste-heat reuse applications. The energy implications of part-load are critical, as efficiency often drops sharply as load decreases across a wide diversity of devices. To quantify the extent of this problem, we derive a dimensionless Part-Load Metric (PLM) based on device efficiency and its frequency distribution of operating hours at various output levels. The PLM quantifies the deviation of a device's actual efficiency from its maximum design efficiency. This metric also serves as a measure of "capital inefficiency," enabling engineers to compare the impact of different part-load solutions and providing a unified framework for evaluating performance across various devices and systems.

Meier, Alan

NLR HPC Facility Power Usage Effectiveness (PUE) Data

Timeseries of Energy Systems Integration Facility (ESIF) Data Center Power Usage Effectiveness (PUE) Data provided in Parquet and compressed CSV formats Power Metrics Timeseries Fields: ts: Timestamp cooling_kw: Cooling (kilowatts) - Captures the power used by fans and pipe trace heaters associated with outdoor cooling equipment. The dedicated tower filter pump power is also captured as cooling load. energy_reuse: Energy Reuse Effectiveness hvac_kw: Heating, ventilation, and air conditioning (kilowatts) - Captures fan walls, fan coils that support the data center electrical rooms, and the make-up air unit. it_power_kw: IT equipment (kilowatts) - Captures power used by the IT equipment on the data center floor. plug_and_light_kw: Lights and utility plugs (kilowatts) - Captures power associated with the data center and dedicated mechanical room. The crank-case heater for the emergency standby generator is also captured as light and plug load. pue: Power Usage Effectiveness pump_kw: Pumps (kilowatts) - Captures power from pumps that move water in the data center Energy Recover Water loop and the Tower Water loops, and also captures power used by the boost pumps that circulate water through the fan walls. Note: The tower filter pump runs constantly to filter water from the data center cooling tower system, so 2.67 kilowatts are attributed to this pump and that is not reflected in this data field. day: Day of month Outside Weather Station Timeseries Fields: ts: Timestamp outside_air_humidity: Outside air humidity - Relative humidity percent outside_air_temp: Outside air temperature - Degrees Fahrenheit day: Day of month More detail: High-Performance Computing Data Center Power Usage Effectiveness

97 MATHEMATICS AND COMPUTING

Low-Power, Load-Balancing Whole Home Electrification Solution: Cooperative Research and Development (Final Report)

Testing was conducted at the Systems Performance Laboratory in NREL’s Energy Systems Integration Facility to test the performance of 120V wall-mounted heat pumps, 120V heat pump water heaters (HPWH), Electric Vehicle Supply Equipment (EVSE), and other plug-in loads, using NeoCharge Smart Splitters and whole home energy software as appropriate. Four different simulated occupancy scenarios were used to evaluate the package of technology and controls.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Scalability and Effectiveness of Smart Charge Management

The rise in electric vehicle (EV) adoption presents growing challenges for power grids, particularly from simultaneous residential charging, which can cause voltage fluctuations and increase feeder peak loads. Baltimore Gas and Electric (BGE), with support from the U.S. Department of Energy, initiated a pilot program to evaluate managed residential EV charging through Smart Charge Management (SCM). This study analyzes real-world charging behavior data from the pilot and feeder-level base loads from BGE to simulate residential charging scenarios through 2035 across the Washington, DC–Baltimore region. Grid impacts under unmanaged charging are compared to three SCM strategies: TOU-immediate, TOU-distributed, and Load Balancing. Results show that the magnitude of peak reduction is highly feeder-dependent. Some feeders achieve reductions of more than 40% at high enrollment levels, while others show improvements closer to 10–15%. This heterogeneity reflects differences in baseline feeder load shapes, EV penetration, and plug-in behavior across customers. Results also highlight trade-offs between shifting load away from peak periods and minimizing secondary demand peaks, offering practical insights for future utility program design.

Electric vehicle

The Jupiter Experiments: High-240 Plutonium Metal Plates Separated by Lead and Reflected by Copper

Each layer consisted of a 6 by 6 matrix of either these fuel-filled containers or solid blocks of copper of the same outer dimensions. An example of this arrangement, along with one of the copper inner reflectors, is shown in Figure 1.4. This figure shows the same aluminum containers from Figure 1.3 but with the aluminum containers completely closed. The lifting rings shown on the copper inner reflector were only for assembly and were not present for the measurement (in which the holes were filled with copper plugs). Figure 1.5 shows the loading arrangement of the aluminum containers, along with aluminum shims around the container arrays to ensure a tight fit between these layers and the surrounding reflectors. All plates were in the same orientation; none were rotated in any fashion. Additional loading information for the PAHN plates and plate loading respective to the room entrance are provided in Figures 1.6 and 1.7, respectively.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Refining Control, Charging, and Battery Chemistry for CO 2 e Savings in Heavy-Duty Off-Road Plug-In Series Hybrid

With current and future regulations continuing to drive reductions in carbon dioxide equivalent (CO 2 e) emissions in the on-road industry, the off-road industry is also likely to be regulated for fuel and CO 2 e savings. This work focuses on converting a heavy-duty off-road material handler from a conventional diesel powertrain to a plug-in series hybrid, achieving a 49% fuel reduction and 29% CO 2 e reduction via simulation. Control strategies were refined for energy savings, including a regenerative braking strategy to increase regenerative braking and a load-following hydraulic strategy to decrease electrical energy consumption. The load-following hydraulic control shuts off the hydraulic electric machine when it is not needed—an approach not previously seen in a load-sensing, pressure-compensated system. Furthermore, these strategies achieved a 24.1% fuel savings, resulting in total savings of 61% in fuel and 41% in CO 2 e in the plug-in series compared to the conventional machine. Beyond control strategies, this study evaluated battery chemistry and charging strategy refinements for total cost of ownership (TCO) and lifetime CO 2 e. LFP batteries emerged as the most cost-effective and least emitting due to their longer lifespan, which reduced replacement frequency. Charging comparisons showed that Level 2 charging (L2C) typically resulted in lower TCO but higher lifetime CO 2 e than DC fast charging (DCFC). DCFC costs were heavily influenced by local demand charges, and DCFC emissions were heavily influenced by local grid emissions.

33 ADVANCED PROPULSION SYSTEMS

Exploring the Model Design Space for Battery Health Management

Battery Health Management (BHM) is a core enabling technology for the success and widespread adoption of the emerging electric vehicles of today. Although battery chemistries have been studied in detail in literature, an accurate run-time battery life prediction algorithm has eluded us. Current reliability-based techniques are insufficient to manage the use of such batteries when they are an active power source with frequently varying loads in uncertain environments. The amount of usable charge of a battery for a given discharge profile is not only dependent on the starting state-of-charge (SOC), but also other factors like battery health and the discharge or load profile imposed. This paper presents a Particle Filter (PF) based BHM framework with plug-and-play modules for battery models and uncertainty management. The batteries are modeled at three different levels of granularity with associated uncertainty distributions, encoding the basic electrochemical processes of a Lithium-polymer battery. The effects of different choices in the model design space are explored in the context of prediction performance in an electric unmanned aerial vehicle (UAV) application with emulated flight profiles.

Saha, Bhaskar

Evaluation of Commercially Available Proprietary Vehicle-to-Home Systems: A V2X Connect Project Report

Bidirectional charging and Vehicle-to-Home (V2H) technologies enable the energy stored in a plug-in hybrid electric vehicle’s (PHEV) or battery electric vehicle’s (BEV) onboard battery to supply residential loads during grid outages and support broader energy management objectives. Conventional backup solutions, such as Uninterruptible Power Supplies (UPS) and standalone inverter systems, are limited in capacity and scalability, whereas PHEV/BEV-based storage offers substantially greater energy reserves that can sustain household loads for extended periods.

33 ADVANCED PROPULSION SYSTEMS

ELECTRIFICATION OF A HEAVY-DUTY OFF-ROAD MATERIAL HANDLER: ENERGY SAVINGS AND EMISSION REDUCTIONS

Federal regulations are driving the adoption of electrification technologies to reduce carbon dioxide equivalent (CO2e) emissions, a metric that quantifies the global warming potential of various greenhouse gases in terms of carbon dioxide (CO2). Although no specific CO2 regulations exist for heavy-duty off-road machines, future reductions are likely, given stricter emissions standards for on-road vehicles. The heavy-duty off-road sector offers significant fuel-saving potential, as its focus has traditionally been on reliability and performance rather than fuel efficiency. This dissertation examines fuel and CO2e savings opportunities on a heavy-duty off-road material handler, the Pettibone Cary-Lift 204i, from stock configuration to simple modifications to a complete teardown and reconfiguration of the machine with a plug-in series hybrid architecture using electrified hydraulics. The study begins by modeling the baseline machine’s fuel and energy consumption, calibrating with experimental data from custom operating cycles. An energy analysis identifies key areas for fuel savings. Two simple powertrain modifications result in a combined 16.2% fuel savings. Next, a Pugh-style analysis narrows a list of electrified architectures, leading to high-fidelity models that evaluate total lifetime CO2e and costs. Higher electrification levels reduce CO2e emissions but increase costs, and electricity grid emissions significantly impact CO2e for plug-in architectures. A plug-in series hybrid is chosen for the project. In its base control form, 49% fuel and 29% CO2e savings are expected from the plug-in series hybrid compared to the baseline machine. Further savings are pursued through regenerative braking (6.3%) and load-following hydraulic control (17.8%), totaling 24.1% fuel savings, and leading to a total of 61% fuel and 41% CO2e savings compared to the baseline. Battery chemistries and charging strategies are also analyzed for cost and CO2e impacts, finding LFP batteries as superior due to longevity, and overnight level 2 charging usually at a lower cost but resulting in higher emissions than opportunity DC fast-charging (DCFC). DCFC emissions are highly dependent on grid emissions, and DCFC cost is highly dependent on grid demand charges. Finally, artificial intelligence is applied to operating cycle recognition. Neural network accuracy ranges from 81% to 99%, with applications to worksite efficiency and safety improvements.

24 POWER TRANSMISSION AND DISTRIBUTION

Total Cost of Ownership Reduction Using Passive Pre-Chamber Ignition in Natural Gas Engines

Spark plug durability is a factor affecting the total cost of ownership (TCO) of spark-ignited natural gas engines, with some heavy-duty platforms requiring plug replacement after only 750 hours of operation. The high ignition energy demand under lean or diluted conditions accelerates electrode wear, shortening plug life and increasing maintenance frequency. This work evaluates passive pre-chamber (PC) ignition operating at lowered spark energies as a strategy to reduce spark energy requirements and extend plug durability, thereby lowering TCO. Experiments were conducted on a medium-duty Cummins 6.7L ISB engine at 1600 RPM and 50% load under varying exhaust gas recirculation (EGR) dilution levels (0–40%). Two passive pre-chambers with 1.1 mm and 1.6 mm nozzle diameters were compared with conventional spark ignition (SI). SI was operated with a fixed coil dwell of 4 ms (~90 mJ), while the PC configuration was tested across 2–4 ms dwell times (~30–90 mJ). Cylinder pressure analysis revealed that PC ignition sustained stable combustion at significantly lower spark energies than SI, with improved combustion stability at ~30 mJ compared with SI at ~90 mJ. The PC system also extended the dilution tolerance beyond that achievable with SI, while delivering up to ~2% higher indicated thermal efficiency and reducing the COV by nearly 90% at 30% EGR. A TCO analysis was conducted to assess the economic benefit of adopting a passive PC system operating at reduced spark energies compared to SI. It was found that adopting a passive PC system could reduce TCO by approximately $11,000 per engine over a five-year operational period, primarily due to fuel savings, extended spark plug life, and reduced maintenance frequency. These projections were weighed against the additional hardware cost of the pre-chamber, yielding a rapid estimated return on investment of ~300 operating hours. Therefore, this work motivates continued research and development of passive PC technology and its commercial adoption in natural gas engines used in transportation applications.

Dhotre, Akash [University of Minnesota]

The standard 20 AH battery

The modular power system, which is the first intended use for the NASA standard battery, is basically a four foot by four foot by eighteen inch box which can handle a complement of three 20 ampere hour batteries or later on the intended use is for three 50 ampere hour batteries to be the full complement. The system is designed to be used as a plug on component on a multi mission modular spacecraft. It has as a design point a basically 1250 watt orbital average load. The way it breaks up in a near earth orbit it would be somewhere around 1,000 watts for everything except 10 minutes, and during any 10 minute period it may go up to a peak of 3,000 watt load. Features of the battery reviewed include criteria to store electrical energy, the battery package, the covers and cases, and electrolytes. The capacities expected are 90 percent, the average cell capacity for 24 C, 90 percent of the actual battery capacity of 19 C, and 85 percent of the actual 25 degree battery capacity at zero discharge voltage for 50 percent DOD new battery is in the vicinity expected or predicted of 26.4 volts.

Zollner, M. T.

Ferroresonant Flux-Coupled Battery Charger

Portable battery charger operates at about 20 kHz to take advantage of relatively low weight and low acoustical noise of ferroresonant circuits operating in this frequency range. Charger split into stationary unit connected to powerline and mobile unit connected to battery or other load. Power transferred to mobile unit by magnetic coupling between mating transformer halves. Advantage where sparking at electrical connection might pose explosion hazard or where operator disabled and cannot manipulate plug into wall outlet. Likely applications for charger include wheelchairs and robots.

Mclyman, C. W.

An economic and technical feasibility analysis of a dual-source heat pump using both the air and the ground

The study investigates the economic and technical performance of a novel dual-source heat pump (DSHP) compared with that of air-source heat pumps (ASHPs) and ground-source heat pumps (GSHPs). The DSHP can use both ambient air and the ground as a heat source or heat sink. It uses ambient air when its temperature is favorable for efficient heat pump operation. When the ambient temperature is too hot or cold, the ground source is used to retain high-efficiency heat pump operation. Since the DSHP can alternately use either the ground heat exchanger (GHE) or ambient air to meet the thermal load, the required size of GHE can be smaller than those of GSHPs. This study models the DSHP using a whole building energy simulation tool (EnergyPlus) coupled with a Python plug-in and Heat Pump Design Model (HPDM) to simulate its heating and cooling performance for a typical single-family home in 15 US climate zones. The required GHE size of the DSHP system is determined through simulations and compared with that of GSHPs. DSHP deployment can reduce electricity use compared to ASHPs, especially in cold climates where it shows a reduction of around 50%. When compared to GSHPs, DSHPs use 20%–40% more electricity in warm climates but consume around the same amount in moderate and colder climates. Since the DSHP can use air source when the ambient temperature is mild, the GHE size needed for the DSHP is about 40% less than that needed for GSHPs in hot climates and about 25% less in cold climates. In conclusion, the life cycle cost analysis shows that the DSHP is economically more feasible than ASHPs in colder regions and economically more feasible than GSHPs in hot and cold regions.

Dual-source heat pumps