NaK Plugging Meter Design for the Feasibility Test Loops

The design and predicted performance of a plugging meter for use in the measurement of NaK impurity levels are presented. The plugging meter is incorporated into a Feasibility Test Loop (FTL), which is a small pumped-NaK loop designed to enable the rapid, small-scale evaluation of techniques such as in situ purification methods and to permit the measurement of bulk material transport effects (not mechanisms) under flow conditions that are representative of a fission surface power reactor. The FTL operates at temperatures similar to those found in a reactor, with a maximum hot side temperature of 900 K and a corresponding cold side temperature of 860 K. In the plugging meter a low flow rate bypass loop is cooled until various impurities (primarily oxides) precipitate out of solution. The temperatures at which these impurities precipitate are indicative of the level of impurities in the NaK. The precipitates incrementally plug a small orifice in the bypass loop, which is detected by monitoring changes in the liquid metal flow rate.

Pearson, J. Boise↗

Unbalanced-flow, fluid-mixing plug with metering capabilities

A fluid mixer plug has holes formed therethrough such that a remaining portion is closed to fluid flow. The plug's inlet face defines a central circuit region and a ring-shaped region with the ring-shaped region including at least some of the plug's remaining portion so-closed to fluid flow. This remaining portion or closed region at each radius R of the ring shaped region satisfies a radius independent, flow-based relationship. Entry openings are defined in the plug's inlet face in correspondence with the holes. The entry openings define an open flow area at each radius of the ring-shaped region. The open flow area at each such radius satisfies the inverse of the flow-based relationship defining the closed regions of the plug.

England, John Dwight↗

Conversion of METL Diagnostic Flowmeters to Permanent Magnet Based Electromagnetic Flowmeters

The Mechanisms Engineering Test Loop (METL) uses three flowmeters to monitor sodium circulation through the main loop, the Cold Trap leg, and the Plugging Meter leg. When constructed, the Cold Trap flowmeter (CTFM) and Plugging Meter flowmeter (PMFM) were equipped with permanent magnets and Hall Sensors. By October of 2019, during normal operations, both the CTFM and PMFM failed, producing either erroneous or zero signals. Repairs to the flowmeters were attempted in January of 2020 but failed to resolve the issues. Therefore, starting in March of 2021, a plan was developed to convert the installed flowmeters to more robust permanent magnet based electromagnetic flowmeters (EMFMs). The Cold Trap EMFM (CT EMFM) and Plugging Meter EMFM (PM EMFM) were fully installed by August of 2021. Initial testing and commissioning were completed in November of 2021. Finally, the first calibration runs were finished in March of 2022. This report discusses the design, conversion, and calibration of the as-built CTFM and PMFM to robust permanent magnet based EMFMs. During the design phase, theoretical models were used to estimate the signal output and required magnet sizes. Then, the CTFM and PMFM were disassembled and converted to EMFMs. After commissioning, the CT EMFM and PM EMFM were calibrated using a ‘Time Transfer Procedure’ carried out with METL Expansion Vessels and Test Vessel Two. The accuracy of the calibration was estimated through an uncertainty analysis. Finally, the report describes some lessons learned for future flowmeter conversions and follow-up work. In total, both METL EMFM’s met the desired performance targets. Testing data showed that the METL EMFMs provide a output signal of roughly 2 mV at 1 GPM and 250 °C. During calibration, flowrates between 0.7 GPM and 2.4 GPM were achieved. In this flow range, calibration coefficients of 0.485 and 0.935 were measured as with errors ranging from 15-5% and 16-5% for the CT EMFM and PM EMFM, respectively. Above 1.5 GPM, the error was assumed to be about 5% for both METL EMFMs. Several points will be considered for future follow-up work on the METL EMFM’s. First, the signal noise issues in the PM EMFM will be addressed. It is likely the source of the noise is due to some stray EMF from a heater. Secondly, the NdFeB magnets will be replaced with a grade that has a Curie temperature above 80 °C. For example, a few grades of NeFeB magnets have Curie temperatures which exceed 150 °C and some SmCo magnets have Curie temperatures as high as 500 °C. Third, more calibration runs will be completed in the range of 0.5-2.5 GPM. This will further improve the accuracy of the calibration coefficient. Fourth, calibration runs will be completed up to 5 GPM. This requires a larger pressure relief valve to be installed on the Expansion Vessel and Test Vessel 2, as well as a revised calibration procedure. Lastly, calibration runs will be completed to account for cold spots in the system, which reduced the inlet temperature of the METL EMFMs. Overall, these points will improve the calibration coefficients derived in this work and also improve the performance of the METL EMFMs.

42 ENGINEERING↗

Preliminary Development of Heat Transfer Model-Based Control Algorithms of Liquid Sodium Purification System: Advanced Sensors and Instrumentation Advanced Controls

Monitoring the operation of sodium purification system is essential for efficient operation of sodium fast reactors. In this work, a heat transfer model has been developed for monitoring the plugging meter and cold trap systems at the Mechanisms Engineering Test Loop (METL) liquid sodium facility at Argonne National Laboratory. The model of the purification system was developed by treating the respective aspects of the cold trap purification loop and plugging meter diagnostic loop as two separate control volumes using information from the METL piping and instrumentation diagram (P&ID). A model predictive controller was designed using first order differential equations with the specified boundary conditions. The system behavior was studied with a tuned optimized procedure using the internal cold trap temperature and plugging meter outlet temperature as control variables, and the air blower temperature as an independent variable respectively. Results of computer simulations obtained in this study compared favorably with experimental data showing very good reference tracking response with negligible overshoot as both plugging meter and cold trap physical models approach the setpoint.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of a Flow Stabilization Algorithm Enabling Measurement of Low Oxygen Concentrations in Liquid Sodium

To enhance the automated control of the plugging meter (PM) and thereby enhance detection fidelity in ultralow oxygen environments [≤1 parts per million by weight (wppm)], a novel proportional derivative controller has been implemented with conventional PM hardware. This ramp sign stabilized flow (RSSF) controller manipulates the sign (heating or cooling direction) at a fixed rate, enabling precise temperature adjustment around the saturation temperature of the bulk sodium. This adjustment helps maintain flow stability in a partially formed sodium oxide plug, thus greatly reducing the temperature amplitude in the plugging cycle and promoting simple and accurate oxygen determinations in addition to an increased sampling rate. Rather than relying on the subjective nature of indexing the time when the flow rate changes due to the plugging or unplugging onset to the PM temperature, a running average of the correlated oxygen concentration with time over multiple plugging events can provide oxygen readings ranging from an absolute uncertainty of 500 wppb in real time to less than 50 wppb for a 24-h sampling window. Finally, the RSSF controller was tested at 508 ± 7 wppb with measured oxygen of 542 ± 179 wppb, further reducing the variance between the saturation temperature and the plugging temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Monitoring and Control in the ANL METL Facility Using an Engineering Digital Twin

The potential benefits of using an engineering digital twin to achieve greater autonomy for monitoring and control functions in advanced reactors was investigated for the Mechanisms Engineering Test Loop (METL) liquid sodium facility at Argonne National Laboratory. The METL sodium purification system served as a representative system as it requires significant human in-the-loop interaction to accomplish its design function. The objective was to demonstrate how real-time operation could be automated while preserving oversight of the operator for ensuring that the system design functions are met. A digital twin model of the purification system was developed for both the cold trap purification loop and plugging meter diagnostic loop using information from the METL piping and instrumentation diagram (P&ID). Automated monitoring and diagnosis of component degradation in the METL facility was demonstrated in tests using the PRO-AID health monitoring software with the digital twin model incorporated in the library of components. Component failures were introduced and were successfully diagnosed in real time. These tests serve to demonstrate an advanced monitoring capability able to differentiate sensor degradation from component degradation, to generate a rank ordering of probabilities of different failure mechanisms that serves to circumvent the false alarm problem with current anomaly detection methods, and how facility monitoring can be transformed from anomaly detection to identification of a specific fault. Automated control of the purification system was demonstrated through simulations that exercised a model predictive controller designed using the digital twin model. Results of these simulations compared favorably with experimental data showing very good reference tracking response with negligible overshoot. In conclusion, these pilot tests and simulations successfully demonstrated the use of a digital twin for improved automation of monitoring and control. It was shown how the digital twin enables switching between control modes from cold trap operation where impurities are removed to plugging meter operation where impurity concentrations are measured.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Office Building Plug Load Disaggregation

This case study focuses on the National Renewable Energy Lab's succesful effort to develop a disaggregated breakdown of device-level power consumption in a zero energy office building by combining smart plug metering with a device inventory.

plug and process loads, PPLs, device-level meterin↗

Investigation of the I-40 Jet-Propulsion Engine in the Cleveland Altitude Wind Tunnel. V - Operational Characteristics: Operational Characteristics - 5

An investigation has been conducted in the Cleveland altitude wind tunnel to determine the operational characteristics of the I-40 jet-propulsion engine over a range of pressure altitudes from 10,000 to 50,000 feet and ram-pressure ratios from 1.00 to 1.76. Engine operational data were obtained with the engine in the standard configuration and with various modifications of the fuel system, the electrical system, and the combustion chambers. The effects of altitude and airspeed on operating speed range, starting, windmilli.ng, acceleration, speed regulation, cooling, and vibration of the standard and modified engines were determined, and damage to parts was noted. Maximum engine speed was obtainable at all altitudes and airspeeds wi th each fuel-control system investigated. The minimum idling speed was raised by increases in altitude and airspeed. The lowest minimum stable speeds were obtained with the standard configuration using 40-gallon nozzles with individual metering plugs. The engine was started normally at altitudes as high as 20,000 feet with all of the fuel systems and ignition combinations except one. Ignition at 70,000 feet was difficult and, although successful ignition occurred, acceleration was slow and usually characterized by excessive tail-pipe temperature. During windmilling investigations of the engine equipped with the standard fuel system, the engine could not be started at ram-pressure ratios of 1.1 to 1.7 at altitudes of 10,000, 20,000 and 30,000 feet. When equipped with the production barometric and Monarch 40-gallon nozzles, the engine accelerated in 12 seconds from an engine speed of 6000 rpm to 11,000 rpm at 20,000 feet and an average tail-pipe temperature of 11000 F. At the same altitude and temperature, all the engine configurations had approximately the same rate of acceleration. The Woodward governor produced the safest accelerations, inasmuch as it could be adjusted to automatically prevent acceleration blow out. The engine speed was held constant by the Woodward governor and the Edwards regulator during simulated dives and climbs at constant throttle position. The bearing cooling system was satisfactory at all altitudes and airspeeds. The engines operated without serious failure, although the exhaust cone, the tail pipe, and the airplane fuselage were damaged during altitude starts.

Golladay, Richard L.↗

Flow plug with length-to-hole size uniformity for use in flow conditioning and flow metering

A flow plug of varying thickness has a plurality of holes formed therethrough. The plug fits in a conduit such that a fluid flow in the conduit passes through the plug's holes. Each hole is defined by a parameter indicative of size in terms of the cross-sectional area thereof. A ratio of hole length-to-parameter is approximately the same for all of the holes.

England, John Dwight↗

Low-Cost Identification and Monitoring of Diverse MELs in Residential and Commercial Buildings with PowerBlade (Final Technical Report)

This report describes our progress in developing a scalable wireless metering system that integrates plug-load energy meters that measure real, reactive, and apparent power along with load monitoring based on extracting high-fidelity electrical waveform features collected at every load to capture power profiles and automatically identify and categorize MELs, and make this technology available to the research, commercial, and government sectors.

47 OTHER INSTRUMENTATION↗

Smart Outlets: Wireless Meter and Control Systems for Plug and Process Loads

Smart outlets control the flow of power to devices plugged into them and measure their energy use. The energy use data can be accessed via an online dashboard or smartphone application, allowing the user to turn power to plug-in devices on or off based on a schedule established in the dashboard or application. This four-page resource is a fact sheet meant to educate commercial building owners on smart outlets: what they are, why we use them, and how to use them in a way that will achieve energy savings while maintaining occupant comfort. The resource also describe how to procure a smart outlet system and how to fully capture their benefits over time. This resource was developed to support the Better Buildings Alliance Plug and Process Loads Technology Research Team.

30 DIRECT ENERGY CONVERSION↗

Emerging Technologies for Improved Plug Load Management Systems: Learning Behavior Algorithms and Automatic and Dynamic Load Detection

Plug loads are responsible for a significant portion of the energy consumed in commercial buildings, yet their distributed and ever-changing nature makes them one of the most challenging building end uses to manage. Plug load management systems exist today that utilize smart plugs to meter and control devices at the outlet level, however, their uptake has been relatively slow in part due to the significant labor required for installation and maintenance. Learning behavior algorithms and automatic and dynamic load detection have been identified as two technology areas that could accelerate the adoption of plug load management systems by reducing these labor demands and providing additional energy efficiency and non-energy benefits. Learning behavior algorithms learn occupant behavior and adjust plug load management systems accordingly, allowing for the automatic creation of optimized control schedules. Automatic and dynamic load detection allows a plug load management system to identify devices as they are plugged in to a building and keeps the system up to date as devices are moved throughout a building. In this paper, we present our findings with respect to the current state of these two technologies based on a review of existing research and patents, as well as a series of interviews with companies working in the plug load space. We have found that, as of now, no commercialized solutions exist for these plug load technologies and that more work is needed to bring them to market. In addition, we summarize our findings related to the technology challenges, market barriers, drivers, and opportunities for these technologies moving forward.

30 DIRECT ENERGY CONVERSION↗

Eddy Current Minimizing Flow Plug for Use in Flow Conditioning and Flow Metering

An eddy-current-minimizing flow plug has an outer radial wall with open flow channels formed between the plug's inlet and outlet. The plug has a central region coupled to the inner surface of the outer radial wall. Each open flow channel includes (i) a first portion originating at the inlet and converging to a location in the plug where convergence is contributed to by changes in thickness of the outer radial wall and divergence of the central region, and (ii) a second portion originating in the plug and diverging to the outlet where divergence is contributed to by changes in thickness of the outer radial wall and convergence of the central region. For at least a portion of the open flow channels, a central axis passing through the first and second portions is non-parallel with respect to the given direction of the flow.

England, John Dwight↗

Eddy Current Minimizing Flow Plug for Use in Flow Conditioning and Flow Metering

An eddy-current-minimizing flow plug has open flow channels formed between the plug's inlet and outlet. Each open flow channel includes (i) a first portion that originates at the inlet face and converges to a location within the plug that is downstream of the inlet, and (ii) a second portion that originates within the plug and diverges to the outlet. The diverging second portion is approximately twice the length of the converging first portion. The plug is devoid of planar surface regions at its inlet and outlet, and in fluid flow planes of the plug that are perpendicular to the given direction of a fluid flowing therethrough.

England, John Dwight↗

Emerging Plug Load Management Technologies that Save Energy and Time

This fact sheet introduces two emerging technologies that could streamline plug load management (PLM) for increased energy savings for building owners: learning behavior algorithms (LBA) and automatic and dynamic load detection (ADLD). Plug loads are responsible for 47% of the energy consumed in commercial buildings, yet their distributed and ever-changing nature makes them challenging to manage. PLM systems exist today that use smart plugs to meter and control devices at the outlet level, but their uptake has been relatively slow in part because of the significant labor required for installation and maintenance. LBA and ADLD may address these challenges and provide additional energy efficiency and nonenergy benefits.

Plug and process loads, PPL, plug loads, plug load↗

Deployable Emergency Shutoff Device Blocks High-Velocity Fluid Flows

NASA's Marshall Space Flight Center has developed a device and method for blocking the flow of fluid from an open pipe. Motivated by the sea-bed oil-drilling catastrophe in the Gulf of Mexico in 2010, NASA innovators designed the device to plug, control, and meter the flow of gases and liquids. Anchored with friction fittings, spikes, or explosively activated fasteners, the device is well-suited for harsh environments and high fluid velocities and pressures. With the addition of instrumentation, it can also be used as a variable area flow metering valve that can be set based upon flow conditions. With robotic additions, this patent-pending innovation can be configured to crawl into a pipe then anchor and activate itself to block or control fluid flow.

Nabors, Sammy A.↗

FTR for: Reducing plug-load electricity footprint of residential buildings through low-cost, non-intrusive sub-metering and personalized feedback technology

The project started in October 2016 and ended in December 2022. The project's principal goals and achievements were: (i) Measure real and reactive electric power consumption in ~400 apartments in multifamily settings of varying size and vintage and publish the data; data was published according to New York State's recommended 15x15 rule continuously from Jan 2019 through December 2022 (10 second time resolution); with the combination of large number of apartments, real and reactive power, as well as high time resolution (10-seconds), the dataset is first of its kind worldwide; because the dataset New York City apartment consumption pre, during, and post pandemic, it further offers unique insights into changes in residential electricity consumption during lockdowns and after modified work from home schedules. (ii) Measure effectiveness of different feedback types to prompt residents to lower their electricity consumption; achieved 11% (kWh-weighted) reduction versus baseline consumption; confirmed previous studies that social comparisons elicit above average responses; showed, for the first time, that the so called boomerang effect in power consumption feedback projects can be explained by a previously hypothesized norm-conforming "magnet effect" (rather than a non-conforming defiance effect), thus substantially advancing the research in the field. (iii) Disaggregate apartment-level consumption to appliance level; because the hardware for electricity consumption unexpectedly allowed only for 10-second time resolution (rather than the 1-second resolution we had planned on), the disaggregation algorithms we developed on sample data could not be applied to the actual field data we collected. The project has yielded high visibility, with a total of 17 publications, from peer reviewed journals, published data sets (free access), blog posts, NY Times, National Public Radio, and CNN.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗