Autonomous Control of Pneumatically-Powered Percussive Drilling Through Highly Layered Formations.
Abstract not provided.
Costs and benefits of pneumatic collection in three specific New York City cases
Highlights: • Pneumatic and truck collection were compared in three New York City locations. • Relative costs, energy use, and greenhouse gas emissions varied significantly. • Variations were due to location-specific factors (e.g., route density, truck type). • Under appropriate conditions, pneumatic collection reduces TMT, BTU, and GHG. • Pneumatic capex may be offset by operating savings and externality benefits. - Abstract: Truck-based collection of municipal solid waste imposes significant negative externalities on cities and constrains the efficiency of separate collection of recyclables and organics and of unit-price-based waste-reduction systems. In recent decades, hundreds of municipal-scale pneumatic collection systems have been installed in Europe and Asia. Relatively few prior studies have compared the economic or environmental impacts of these systems to those of truck collection. A critical factor to consider when making this comparison is the extent to which the findings reflect the specific geographic, demographic, and operational characteristics of the systems considered. This paper is based on three case studies that consider the specific characteristics of three locations, comparing pneumatic systems with conventional collection on the basis of actual waste tonnages, composition, sources, collection routes, truck trips, and facility locations. In one case, alternative upgrades to an existing pneumatic system are compared to a potential truck-collection operation. In the other cases, existing truck operations are compared to proposed pneumatic systems which, to reduce capital costs, would be installed without new trenching or tunneling through the use of existing linear infrastructure. For the two proposed retrofit pneumatic systems, up to 48,000 truck kilometers travelled would be avoided and energy use would be reduced by up to 60% at an incremental cost of up to $400,000 USD per year over the total operating-plus-capital cost of conventional collection. In the location where a greenfield pneumatic system is already in operation, truck collection would be both less expensive and more energy-efficient than pneumatic collection. The results demonstrate that local geographic, demographic, and operational conditions play a decisive role in determining whether pneumatic collection will reduce energy requirements, produce more or fewer greenhouse gas emissions, and cost more or less over the long-term. These findings point to the local factors that will determine the relative economic and environmental costs and benefits in specific situations.
Methane Emissions Produced by Pneumatic Devices and Produced Water Tanks on Natural Gas Wellsites
In recent years, more scrutiny has been placed on the release of greenhouse gasses (GHGs) by the oil and gas industry in North America as climate concerns increase. In the coming years, stricter regulations proposed by the Environmental Protection Agency (EPA) concerning the release of GHGs will further direct attention to GHG emissions quantification, modeling, and overall reduction. Active natural gas wellsites employ production equipment that routinely emits methane during normal operation. Production equipment often includes, but is not limited to, gas production units (GPUs), pneumatic controllers (PCs) and actuators powered by produced natural gas, and produced water storage tanks. This work details direct methane emission measurements taken at active natural gas wellsites originating from intermittent pneumatic controllers and produced water storage tanks. Efforts to model methane flows originating from these sources are also detailed, and those results are compared to direct measurement. The direct methane emissions measurement campaign collected flow data from two active dry wellsites in the Marcellus shale region. These measurement campaigns captured, in total, several weeks of continuous data from these sites. Data included multiple pneumatic device vent flowrate channels, a single channel monitoring total emissions vented from the produced water storage tanks, and corresponding site weather data. Periodic composition measurements were taken from flows vented from produced water tanks. Computational modeling efforts attempted to mimic a given site’s methane emissions behavior given limited input parameters. Direct measurement data and simulation data yielded, through reduction and analysis, apparent methane emissions factors, statistics on pneumatic device actuation events, important relationships between GPU parameters and pneumatic device actuation events, produced water storage tank vent flows and flow compositions, and parameters most contributing to the magnitude and frequency of these fugitive methane emissions. Measurements, considering data from a 72hr period, produced PC emissions factors from 0.008 to 0.03 SCFH per device with an average device emitting 0.026 SCFH at the first site. The second site produced PC emissions factors spanning from 0.05 to 25.47 SCFH with an average device emitting 1.93 SCFH not including the 25.47 SCFH device, which was assumed to be malfunctioning. Two unique water tank emission measurements were made, 618 g CH4 per hour and 32.6 g CH4 per hour. On a water basis, the water tank emissions factors were 0.66 and 0.042 kg CH4 per bbl of water, respectively.
Novel Use of a Pneumatic Compression Device for Haemostasis of Haemodialysis Fistula Access Catheterisation Sites
PurposeTransradial pneumatic compression devices can be used to achieve haemostasis following radial artery puncture. This article describes a novel technique for acquiring haemostasis of arterio-venous haemodialysis fistula access sites without the need for suture placement using one such compression device.Materials and MethodsA retrospective review of fistulograms with or without angioplasty/thrombectomy in a single institution was performed. 20 procedures performed on 12 patients who underwent percutaneous intervention of failing or thrombosed arterio-venous fistulas (AVF) had 27 puncture sites. Haemostasis was achieved using a pneumatic compression device at all access sites. Procedure details including size of access sheath, heparin administration and complications were recorded.ResultsTwo diagnostic fistulograms, 14 fistulograms and angioplasties and four thrombectomies were performed via access sheaths with an average size (±SD) of 6 Fr (±1.12). IV unfractionated heparin was administered in 11 of 20 procedures. Haemostasis was achieved in 26 of 27 access sites following 15–20 min of compression using the pneumatic compression device. One case experienced limited bleeding from an inflow access site that was successfully treated with reinflation of the device for a further 5 min. No other complication was recorded.ConclusionsHaemostasis of arterio-venous haemodialysis fistula access sites can be safely and effectively achieved using a pneumatic compression device. This is a technically simple, safe and sutureless technique for acquiring haemostasis after AVF intervention.
Analytical Solution to the Pneumatic Transient Rod System at ACRR
The ACRR pulse is pneumatically driven by nitrogen in a system of pipes, valves and hoses up to the connection of the pneumatic system and mechanical linkages of the transient rod (TR). The main components of the TR pneumatic system are the regulator, accumulator, solenoid valve and piston-cylinder assembly. The purpose of this analysis is to analyze the flow of nitrogen through the TR pneumatic system in order to develop a motion profile of the piston during the pulse and be able to predict the pressure distributions inside both the cylinder and accumulators. The predicted pressure distributions will be validated against pressure transducer data, while the motion profile will be compared to proximity switch data. By predicting the motion of the piston, pulse timing will be determined and provided to the engineers/operators for verification. The motion profile will provide an acceleration distribution to be used in Razorback to more accurately predict reactivity insertion into the system.
Microfluidic pressure amplifier circuits and electrostatic gates for pneumatic microsystems
An electrostatic actuator is provide that can include a fluidic line, a first electrode, and a second electrode such that a gate chamber portion of the fluidic line is sandwiched between the first electrode and the second electrode. The electrostatic actuator can also include a pressure-balancing channel in fluid communication with the gate chamber portion where the first electrode is sandwiched between the pressure-balancing channel and the gate chamber portion. A pneumatic valve system is provided which includes an electrostatic gate and a fluidic channel fluidly separate from a fluidic control line. A pneumatic valve portion of the fluidic control line can be positioned relative to a portion of the fluidic channel such that expansion of the pneumatic valve portion restricts fluid flow through the fluidic channel. Methods of using an electrostatic actuator and a pneumatic valve system are also provided.
Determination of the Most Likely Wear Zones of Pipe Bends in the Pulsed Pneumatic Conveyor at the RT-1 Plant
The results of an experimental investigation and numerical modeling of the most likely high-wear zones in 90° pipeline bends in the pulsed pneumatic conveyor system at the RT-1 plant of the Mayak Industrial Association are presented. The experimental studies were conducted on a model of a pulsed pneumatic conveyor system; the numerical modeling of the gas-dynamic flow in the pipeline channel was performed in a model of a two-dimensional non-stationary motion of a compressible medium. It was found on the basis of the experimental results obtained using the model and numerical modeling in the homogeneous approximation that local regions with high wear of walls in the 90° pipe bends in the pulsed pneumatic conveyor do indeed exist and their experimentally found positions agree with the calculations.
Controllable pneumatic generator based on the catalytic decomposition of hydrogen peroxide
This paper presents a novel compact and controllable pneumatic generator that uses hydrogen peroxide decomposition. A fuel micro-injector using a piston-pump mechanism is devised and tested to control the chemical decomposition rate. By controlling the injection rate, the feedback controller maintains the pressure of the gas reservoir at a desired pressure level. Thermodynamic analysis and experiments are performed to demonstrate the feasibility of the proposed pneumatic generator. Using a prototype of the pneumatic generator, it takes 6 s to reach 3.5 bars with a reservoir volume of 200 ml at the room temperature, which is sufficiently rapid and effective to maintain the repetitive lifting of a 1 kg mass.
Instrumentation and Data Analysis Supporting the Transient Rod Pneumatic System Design Study at the Annular Core Research Reactor
The Sandia National Laboratories Annular Core Research Reactor (ACRR) has been experiencing intermittent failures of its pneumatically operated transient rod system. The most frequent failures have been to the dashpot rod where it connects to the upper aluminum connecting rod. Within the three systems, Transient Rod (TR) A has the most frequent failures. In order to conduct the pulse operations, the Transient Rods are pneumatically driven to quickly remove "poison" from the reactor core. During these pulse operations increased forces and vibrations are placed on the TR system. In an effort to fix these problems, Sandia's TA-V Nuclear Reactor and Systems Engineering Department (Engineering Department) has started an extensive Transient Rod Pneumatic System Design Study. The goal of this study is to determine the causes of the elevated failure rates in TR A. This necessitates an increased understanding of the dynamics in the TR systems. This report will cover the approach taken and reasoning behind the choices of instrumentation, calibration, data collection and data analysis used to diagnose these failures. In order to determine the types and specifications for the sensors that will be installed, estimates of the TR system performance needed to be determined. Using known and assumed parameters, mechanical and thermodynamic models were developed, and calculations performed to estimate ranges of displacement, speed, and acceleration experienced by the transient rod system. After some preliminary data collection, the thermodynamic models were refined for better accuracy. After installation of the full suite of sensors, data can be collected and analyzed in order to determine the cause of the increased failures.
Wireless Pneumatic Thermostat Evaluation, Ronald Reagan Building and International Trade Center
To be effective at maintaining indoor air conditions, a building heating, ventilation, and air conditioning (HVAC) system needs to be controlled in some fashion. The control system needs to sense the temperature of a space, feeding it to a control system, and manipulate the HVAC equipment to maintain desired temperatures for the occupants. Within the portfolio of buildings under the jurisdiction, custody, or control of the General Services Administration (GSA), approximately 20% have HVAC systems that are operated by pneumatic control systems. These buildings are under the same energy conservation mandates as all federal facilities. Unfortunately, the major drawback to pneumatic systems is that they are not capable of implementing automated energy-saving control strategies. They can’t automatically change the thermostat setting at night and on weekends in the same way as more modern control systems such as direct digital controls (DDCs). Converting a building from a pneumatic control system to DDCs is typically cost prohibitive.
Buckling Pneumatic Linear Actuators Inspired by Muscle
To being, the mechanical features of biological muscles are difficult to reproduce completely in synthetic systems. A new class of soft pneumatic structures (vacuum-actuated muscle-inspired pneumatic structures) is described that combines actuation by negative pressure (vacuum), with cooperative buckling of beams fabricated in a slab of elastomer, to achieve motion and demonstrate many features that are similar to that of mammalian muscle.
Pneumatic Microvalve-Based Hydrodynamic Sample Injection for High-Throughput, Quantitative Zone Electrophoresis in Capillaries
A hybrid microchip/capillary CE system was developed to allow unbiased and lossless sample loading and high throughput repeated injections. This new hybrid CE system consists of a polydimethylsiloxane (PDMS) microchip sample injector featuring a pneumatic microvalve that separates a sample introduction channel from a short sample loading channel and a fused silica capillary separation column that connects seamlessly to the sample loading channel. The sample introduction channel is pressurized such that when the pneumatic microvalve opens briefly, a variable-volume sample plug is introduced into the loading channel. A high voltage for CE separation is continuously applied across the loading channel and the fused silica capillary separation column. Analytes are rapidly separated in the fused silica capillary with high resolution. High sensitivity MS detection after CE separation is accomplished via a sheathless CE/ESI-MS interface. The performance evaluation of the complete CE/ESI-MS platform demonstrated that reproducible sample injection with well controlled sample plug volumes could be achieved by using the PDMS microchip injector. The absence of band broadening from microchip to capillary indicated a minimum dead volume at the junction. The capabilities of the new CE/ESI-MS platform in performing high throughput and quantitative sample analyses were demonstrated by the repeated sample injection without interrupting an ongoing separation and a good linear dependence of the total analyte ion abundance on the sample plug volume using a mixture of peptide standards. The separation efficiency of the new platform was also evaluated systematically at different sample injection times, flow rates and CE separation voltages.
A case study of replacing pneumatic tools with battery-powered ones at an automobile assembly plant
Compressed air is ubiquitous in manufacturing facilities and vital for the proper operation of numerous types of manufacturing equipment and processes, but compressed air systems are highly inefficient. One way of reducing compressed air usage and the associated electricity consumption is to replace pneumatic tools with battery-powered ones. This paper studied the energy cost savings and return on investment (ROI) of replacing pneumatic torque wrenches with battery-powered ones at a typical automobile assembly plant. With a total triggered time of 400.6 hours and an assumed electricity rate of $0.10/kWh, the annual energy cost savings was estimated to be $104/year per tool. The simple payback period and ROI were 5.8 years and 17.3%, respectively.
SELF-HEALING PNEUMATIC ACTUATOR DIAPHRAGMS
In the oil and gas industry, damaged diaphragms in pneumatic actuators can lead to unintended methane leaks, increasing emissions. In this work, replacement self-healing diaphragms are manufactured for a commercial pneumatic actuator. To enable self-healing, hollow microvascular networks are created within the diaphragms using sacrificial 3D printed PLA w/ tin(II) oxalate. These microvascular networks are filled with healing chemistries and, upon damage, rupture. After rupturing, the healing chemistries mix and cure to “heal” the damage and reduce leaks. Separate actuator test stands using nitrogen gas and using natural gas were developed to assess the healing performance of diaphragms. A fatigue stand was also developed to evaluate the effects of the different microvascular network geometries on the fatigue life of diaphragms. Our results demonstrate self-healing in diaphragms subjected to damage and tested for leaks. In fatigue testing, our results indicate that the introduction of microvascular networks does not influence the fatigue life.
Optimization Simulations for a Gamma-Ray Calibration Standard for a Cyclic Neutron Activation Analysis Pneumatic System at the Penn State Breazeale Reactor
For new experimental setups, the initial testing and calibrations can be expensive and time consuming without prior optimization. However, these issues can be mitigated using realistic modeling and simulation studies of the proposed system a priori. Specifically, an experiment can be performed virtually using realistic simulations and the expected results evaluated to inform adjustments of the experimental setup to achieve optimum results. At the Penn State Breazeale Reactor, a new pneumatic transfer system has been developed for the detection and characterization of short-lived fission fragments to enhance and complement existing nuclear data. The system accomplishes this task by transporting samples cyclically between an assortment of gamma-ray/neutron detectors and the reactor-core vicinity with sub-second transit times. The measured neutron flux paired with simulations of detector response using Geant4 and a custom module for estimating cascade summing effects and corrections were used to select sample-material masses for system characterization. With the optimized sample masses, an experimental counting plan for characterizing the repeatability of the newly developed pneumatic system was developed. Finally, the predictions made with these simulations allowed for optimization of the irradiation sample characteristics and gamma-ray detection system.
Apparatus, system, and method for providing fabric-elastomer composites as pneumatic actuators
Soft pneumatic actuators based on composites consisting of elastomers with embedded sheet or fiber structures (e.g., paper or fabric) that are flexible but not extensible are described. On pneumatic inflation, these actuators move anisotropically, based on the motions accessible by their composite structures. They are inexpensive, simple to fabricate, light in weight, and easy to actuate. This class of structure is versatile: the same principles of design lead to actuators that respond to pressurization with a wide range of motions (bending, extension, contraction, twisting, and others). Paper, when used to introduce anisotropy into elastomers, can be readily folded into three-dimensional structures following the principles of origami; these folded structures increase the stiffness and anisotropy of the elastomeric actuators, while keeping them light in weight.
Apparatus for pneumatic shuttering of an aerosol particle stream
The invention provides pneumatic shuttering of a focused or collimated aerosol particle stream. The aerosol stream can be collimated by an annular sheath of inert or non-inert gas. The apparatus propagates a sheathed aerosol stream through a series of aerodynamic lenses along the axis of a flow cell. The final lens is typically positioned above a substrate, so that direct material deposition is provided. A substantially perpendicularly-flowing gas external to the aerodynamic lens system is used to redirect the particle stream away from the flow axis and through an exhaust port, thereby shuttering the collimated aerosol stream. The pneumatic shutter enables printing of discreet structures, with on/off shuttering times of approximately 1 to 100 milliseconds.