Search NASA⌕ Search

SEARCH · Search NASA

Results for “point of care devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A Charge Sensitive Pre-Amplifier for Smart Point-of-Care Devices Employing Polymer Based Lab-on-a-Chip

With increasing emphasis on implantable and portable medical devices, low-power, small-chip-area sensor readout system realized in lab-on-a-chip (LOC) platform is gaining more and more importance these days. The main building blocks of the LOC system include a front-end transducer that generates an electrical signal in response to the presence of an analyte of interest, signal processing electronics to process the signal to comply with a specific transmission protocol and a low-power transmitter, all realized in a single integrated circuit platform. Low power consumption and compactness of the components are essential requirements of the LOC system. This paper presents a novel charge sensitive pre-amplifier developed in a standard 180-nm CMOS process suitable for implementing in an LOC platform. The pre-amplifier converts the charge generated by a pyroelectric transducer into a voltage signal, which provides a measurement of the temperature variation in biological fluids. The proposed design is capable of providing 0.8-mV/pC gain while consuming only 2.1 μW of power. Finally, the pre-amplifier composed of integrated components occupies an area of 0.038 mm 2 .

36 MATERIALS SCIENCE↗

Introduction

The 2014 SPIE Sensing Technologies for Global Health, Military Medicine and Environmental Monitoring conference embraced a wealth of state-of-the-art information in basic and applied science. This event covered the latest developments in the following areas: Non-invasive Disease Diagnostics for Global Health- This opening series of two consecutive sessions focused on oral biospecimen based rapid assays and point-of-care devices for the detection of pathogens causing infectious diseases, biomarkers for cancer, and analytes for noncommunicable diseases such as diabetes. They also covered presentations on the human proteasome and microbiome with linkage to human diseases and diagnostic approaches. The sessions were built on the past experience and expertise of the National Institutes of Health, National Institutes of Dental and Craniofacial Research. Military Medicine I: Traumatic Brain Injury and PTSD-This assembly covered oral-biomarker based diagnostics for brain damage and TBI as well as prevention and rehabilitation technologies. Neurorehabilitation and noninvasive neuromodulation were also discussed as critical approaches for effective functioning. Military Medicine II: Physiology and Medicine of Extreme Environments and Spaceflight-This scientific segment showcased physiological, pharmacological and diagnostic sensing methodologies during spaceflight per the National Aeronautics and Space Administration as well as military-relevant toxicans and future sensing trends per the Department of Defense. It also included latest technologies to determine hydration status in warfighters, eye surgery using the latest laser technologies, and sensing tools for blood analysis.  Sensing Technologies for Disease Diagnostics and Environmental Monitoring-This closing series of two consecutive sessions provided the venues to learn and discuss more results on the next generation of diagnostic tools and field technologies for diseases, including biomarker detection by digital imaging, multiplex technologies, capillary electrophoresis and molecular platforms serving as labs-on-chips. This conference allowed cross-fertilization of ideas, projects and collaborative work by a multidisciplinary audience of national and international colleagues from the academia, industry and federal government: The National Institutes of Health, National Aeronautics and Space Administration, and the Department of Defense.

Wotring, Virginia E.↗

Artificial Intelligence Medical Support for Long-Duration Space Missions

We envision an artificial intelligence (AI) based system that will provide support and recommendations to the crew medical officer (CMO) and ground flight surgeon during long-duration space missions. Such a system would be pretrained on the knowledgebase of clinical knowledge on Earth, minimizing the amount of Earth data that needs to be transferred into space. Then during deployment, the system would be constantly refined through active learning from diverse streams of data from sensors in the spacecraft, data collected daily from individual astronauts, and human-in-the-loop feedback from the crew. The model could be interrogated for predictions and recommendations on personalized crew health based on the overall status of the spacecraft, medicinal stores, and status of other crew members. Adaptation techniques would be used to incorporate spaceflight data that have very different distributions from the training data due to the extreme environment. Edge computing and the most advanced neuromorphic processing would enable computation in scenarios with low power and bandwidth, while dimensionality reduction would be employed to ensure that the input data streams from spaceflight are as small as possible. In order to realize this long-term vision, several hardware and software aspects need to be developed and assembled. First, models pretrained on Earth biomedical data would need to be evaluated for predictive accuracy, and the best one selected. That model would need to be adapted to learn from diverse, sparse, and inconsistently measured data streams, as well as human-in-the-loop feedback. A data integration, standardization, and dimensionality reduction methodology would need to be developed to handle all data types and feed them into the model. Once the software and data infrastructure is developed, it would need to be integrated with small footprint compute processors and tested in high-radiation, high-vibration, unregulated temperature situations. As a short-term goal, we recommend to focus on the development of the data and model software structure. Several large language models (LLM) already exist that have been trained on Earth biomedical and clinical knowledgebases, including BioMedLLM, Med-PaLM, SPOKE LLM, and Foresight. These models need to be evaluated for accuracy and the best one chosen for a proof-of-concept structure, while maintaining awareness of the accelerating AI field and incorporating any newly improved model architectures as needed. Then, we recommend to develop a database of synthetic data types to mimic the diverse data streams that are expected in a long-duration space mission. This should include environmental and microbial data from the spacecraft, non-invasive data from wearables and point-of-care devices employed by astronauts, and more invasive molecular and physiological monitoring of clinical and biomarker data from astronauts. The data standardization methodology should be developed, and these data streams used to refine the clinical LLM. Several scenarios should be developed that could plausibly come up in a long-duration space mission, and changes or aberrations introduced to the data at specific times to mimic these scenarios. Then, question and answer tasks should be designed to interrogate the model for predictions and recommendations, with acceptable answers already identified.

Artificial Intelligence↗

Biological Research and Space Health Enabled by Machine Learning to Support Deep Space Missions

A key science goal of the NASA “Moon to Mars” campaign is to understand how biology responds to the Lunar, Martian, and deep space environments in order to advance fundamental knowledge, reduce risk, and support safe, productive human space missions. Through the powerful emerging approaches of artificial intelligence (AI) and machine learning (ML), a paradigm shift has begun in biomedical science and engineered astronaut health systems, to enable Earth independence and autonomy of mission operations. Here we present an overview of AI/ML architecture to support deep space mission goals, developed with leaders in the field. First, we focus on the fundamental biological research that supports our understanding of physiological responses to spaceflight, and we describe current efforts to support AI/ML research including data standardization and data engineering through maximally open and FAIR (findable, accessible, interoperable, reusable) databases and the generation of AI-ready datasets for reuse and analysis. We also discuss remote data management frameworks for research data as well as environmental and health data that are generated during deep space missions. We highlight several research projects that leverage data standardization and management for fundamental biological discovery to uncover the complex effects of space travel on living systems. Next, we provide an overview of cutting-edge AI/ML approaches that can be integrated to support remote monitoring and analysis during deep space missions, including generative models and large language models to learn the underlying biomedical patterns and predict outcomes or answer questions during off world medical scenarios. We also describe current AI/ML methods to support this research and monitoring through automated cloud-based labs which enable limited human intervention and closed-loop experimentation in remote settings. These labs could support mission autonomy by analyzing environmental data streams, and would be facilitated through in situ analytics capabilities to avoid sending large raw data files through low bandwidth communications. Finally, in the context of deep space missions with limited communications or access to medical advice from Earth, we describe a solution for integrated, real-time mission biomonitoring across hierarchical levels from continuous environmental monitoring, to wearables and point-of-care devices, to molecular and physiological monitoring. We introduce a precision space health system that will ensure that the future of space health is predictive, preventative, participatory and personalized.

artificial intelligence↗

Dean vortex-enhanced blood plasma separation in self-driven spiral microchannel flow with cross-flow microfilters

Point-of-care (POC) diagnostic devices have been developing rapidly in recent years, but they are mainly using saliva instead of blood as a test sample. A highly efficient self-separation during the self-driven flow without power systems is desired for expanding the point-of-care diagnostic devices. Microfiltration stands out as a promising technique for blood plasma separation but faces limitations due to blood cell clogging, resulting in reduced separation speed and efficiency. These limitations are mainly caused by the high viscosity and hematocrit in the blood flow. A small increment in the hematocrit of the blood significantly increases the pressure needed for the blood plasma separation in the micro-filters and decreases the separation speed and efficiency. Addressing this challenge, this study explores the feasibility of diluting whole blood within a microfluidic device without external power systems. This study implemented a spiral microchannel utilizing the inertial focusing and Dean vortex effects to focus the red blood cells and extract the blood with lower hematocrit. The inertial migration of the particles during the capillary flow was first investigated experimentally; a maximum of 88% of the particles migrated to the bottom and top equilibrium positions in the optimized 350 × 60 μm (cross-sectional area, 5.8 aspect ratio) microchannel. With the optimized dimension of the microchannel, the whole blood samples within the physiological hematocrit range were tested in the experiments, and more than 10% of the hematocrit reduction was compared between the outer branch outlet and inner branch outlet in the 350 × 60 μm microchannel.

Biochemistry & Molecular Biology↗

Simple Bioparticle Filtration Device Based on an Ultralow-Fouling Zwitterionic Polyurethane Membrane for Rapid Large-Volume Separation of Plasma and Viruses from Whole Blood

Plasma separation from whole blood is oftent required as an essential first step when performing blood tests with a viral assay. However, developing a point-of-care plasma extraction device with a large output and high virus recovery remains a significant obstacle to the success of on-site viral load tests. Here, we report a portable, easy-to-use, cost-efficient, membrane-filtration-based plasma separation device that enables rapid large-volume plasma extraction from whole blood, designed for point-of-care virus assays. The plasma separation is realized by a low-fouling zwitterionic polyurethane-modified cellulose acetate (PCBU-CA) membrane. The zwitterionic coating on the cellulose acetate membrane can decrease surface protein adsorption by 60% and increase plasma permeation by 46% compared with a pristine membrane. The PCBU-CA membrane, with its ultralow-fouling properties, enables rapid plasma separation. The device can yield a total of 1.33 mL plasma from 10 mL whole blood in 10 min. The extracted plasma is cell-free and exhibits a low hemoglobin level. In addition, our device demonstrated a 57.8% T7 phage recovery in the separated plasma. The results of real-time polymerase chain reaction analysis confirmed that the nucleic acid amplification curve of the plasma extracted by our device is comparable to that obtained by centrifugation. With its high plasma yield and good phage recovery, our plasma separation device provides an excellent replacement for traditional plasma separation protocols for point-of-care virus assays and a broad spectrum of clinical tests.

36 MATERIALS SCIENCE↗

Tunable optical metamaterial-based sensors enabled by closed bipolar electrochemistry

Enabled by the proliferation of nanoscale fabrication techniques required to create spatially repeating, sub-wavelength structures to manipulate the behavior of visible-wavelength radiation, optical metamaterials are of increasing interest. Here we develop and characterize a chemical sensing approach based on electrochemical tuning of the optical response function of large-area, inexpensive nanoaperture metamaterials at visible and near-IR wavelengths. Nanosphere lithography is used to create an ordered array of sub-wavelength apertures in a Au film. The spacing of these apertures is established during fabrication, based on the size of the polystyrene nanospheres. Tunable shifts in the transmission spectrum can be produced post-fabrication by electrodeposition of a dissimilar metal, Ag, using the nanoaperture film as one electrode in a 2- electrode closed bipolar electrochemical (CBE) cell, altering hole size, film thickness, and film composition while maintaining hole spacing dictated by the original pattern. Optical transmission spectra acquired under galvanostatic conditions can be expressed as a linear combination of the initial and final (saturated) spectra, and the resulting response function exhibits a sigmoidal response with respect to the amount of charge (or metal) deposited. This architecture is then used to perform optical coulometry of model analytes in a CBE-based analyte-reporter dual cell device, thus expanding the capability of CBE-based sensors. Increasing the exposed electrode area of the analyte cell increases the response of the device, while modifying the circuit resistance alters the balance between sensitivity and dynamic range. These tunable nanoaperture metamaterials exhibit enhanced sensitivity compared to CBE electrochromic reporter cells to the μM to nM concentration range, suggesting further avenues for development of CBE-based chemical sensors as well as application to inexpensive, point-of-care diagnostic devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bead-based microfluidic immunoassay for diagnosis of Johne's disease

Microfluidics technology offers a platform for development of point-of-care diagnostic devices for various infectious diseases. In this study, we examined whether serodiagnosis of Johne s disease (JD) can be conducted in a bead-based microfluidic assay system. Magnetic micro-beads were coated with antigens of the causative agent of JD, Mycobacterium avium subsp. paratuberculosis. The antigen-coated beads were incubated with serum samples of JD-positive or negative serum samples and then with a fluorescently-labeled secondary antibody (SAB). To confirm binding of serum antibodies to the antigen, the beads were subjected to flow cytometric analysis. Different conditions (dilutions of serum and SAB, types of SAB, and types of magnetic beads) were optimized for a great degree of differentiation between the JD-negative and JD-positive samples. Using the optimized conditions, we tested a well-classified set of 155 serum samples from JD negative and JD-positive cattle by using the bead-based flow cytometric assay. Of 105 JD-positive samples, 63 samples (60%) showed higher antibody binding levels than a cut-off value determined by using antibody binding levels of JD-negative samples. In contrast, only 43-49 JD-positive samples showed higher antibody binding levels than the cut-off value when the samples were tested by commercially-available immunoassays. Microfluidic assays were performed by magnetically immobilizing a number of beads within a microchannel of a glass microchip and detecting antibody on the collected beads by laser-induced fluorescence. Antigen-coated magnetic beads treated with bovine serum sample and fluorescently-labeled SAB were loaded into a microchannel to measure the fluorescence (reflecting level of antibody binding) on the beads in the microfluidic system. When the results of five bovine serum samples obtained with the system were compared to those obtained with the flow cytometer, a high level of correlation (linear regression, r2 = 0.994) was observed. In a further experiment, we magnetically immobilized antigen-coated beads in a microchannel, reacted the beads with serum and SAB in the channel, and detected antibody binding to the beads in the microfluidic system. A strong antibody binding in JD-positive serum was detected, whereas there was only negligible binding in negative control experiments. Our data suggest that the bead-based microfluidic system may form a basis for development of an on-site serodiagnosis of JD. Key Words: Mycobacterium avium ssp. paratuberculosis, Johne s disease, microfluidics, lab-on-a-chip.

60 APPLIED LIFE SCIENCES↗

Electrochemical detection of leukemia oncogenes using enzyme-loaded carbon nanotube labels

Here we describe an ultrasensitive electrochemical nucleic acids assay amplified by carbon nanotubes (CNTs)-based labels for the detection of human acute lymphocytic leukemia (ALL) related p185 BCR-ABL fusion transcript. The carboxylated CNTs were functionalized with horseradish peroxidase (HRP) molecules and target-specific detection probes (DP) via diimide-activated amidation, and used to label and amplify target hybridization signal. The activity of captured HRP was monitored by square-wave voltammetry measuring the electroactive enzymatic product in the presence of 2-aminophenol and hydrogen peroxide substrate solution. The effect of DP and HRP loading of the CNT-based labels on its signal-to-noise ratio of electrochemical detection was studied systematically for the first time. Under optimized conditions, the signal-amplified assay achieved a detection limit of 83 fM targets oligonuecleotides and a 4-order wide dynamic range of target concentration. The resulting assay allowed a robust discrimination between the perfect match and a three-base mismatch sequence. When subjected to full-length (491 bp) DNA oncogene, the approach demonstrated a detection limit of approximately 33 pg of the target gene. The high sensitivity and specificity of assay enabled PCR-free detection of target transcripts in as little as 65 ng of mRNA extracted from positive ALL cell lines SUP-B15, in comparison to those obtained from negative cell lines HL-60. The approach holds promise for simple, low cost and ultrasensitive electrochemical nucleic acids detection in portable devices, point-of-care and early disease diagnostic applications.

Environmental Molecular Sciences Laboratory↗

Towards microfluidic reactors for cell-free protein synthesis at the point-of-care

Cell-free protein synthesis (CFPS) is a powerful technology that allows for optimization of protein production without maintenance of a living system. Integrated within micro- and nano-fluidic architectures, CFPS can be optimized for point-of care use. Here, we describe the development of a microfluidic bioreactor designed to facilitate the production of a single-dose of a therapeutic protein, in a small footprint device at the point-of-care. This new design builds on the use of a long, serpentine channel bioreactor and is enhanced by integrating a nanofabricated membrane to allow exchange of materials between parallel reactor and feeder channels. This engineered membrane facilitates the exchange of metabolites, energy, and inhibitory species, prolonging the CFPS reaction and increasing protein yield. Membrane permeability can be altered by plasma-enhanced chemical vapor deposition and atomic layer deposition to tune the exchange rate of small molecules. This allows for extended reaction times and improved yields. Further, the reaction product and higher molecular weight components of the transcription/translation machinery in the reactor channel can be retained. As a result, we show that the microscale bioreactor design produces higher protein yields than conventional tube-based batch formats, and that product yields can be dramatically improved by facilitating small molecule exchange within the dual-channel bioreactor.

60 APPLIED LIFE SCIENCES↗

Sensitive electrochemical detection of horseradish peroxidase at disposable screen-printed carbon electrode

A rapid, simple and sensitive electrochemical assay of horseradish peroxidase (HRP) performed on disposable screen-printed carbon electrode was developed. HRP activities were monitored by square-wave voltammetric (SWV) measuring the electroactive enzymatic product in the presence of o-aminophenol and hydrogen peroxide substrate solution. SWV analysis demonstrated a greater sensitivity and shorter analysis time than the widely used amperometric and differential-pulsed voltammetric methods. The voltammetric characteristics of substrate and enzymatic product as well as the parameters of SWV analysis were optimized. Under optimized conditions, a linear response for HRP from 0.003 - 0.1 U/mL and a detection limit of 0.002 U/mL (1.25×10-15 mol in 25 µL) were obtained with a good precision (RSD = 8%; n = 6). This rapid and sensitive HRP assay with microliters-assay volume could be readily integrated to portable devices and point-of-care (POC) diagnosis applications.

59 BASIC BIOLOGICAL SCIENCES↗

Stretchable Photodiodes with Polymer-Engineered Semiconductor Nanowires for Wearable Photoplethysmography

Healthcare systems worldwide have been stressed to provide sufficient resources to serve the increasing and aging population in our society. The situation became more challenging at the time of pandemic. Technology advancement, especially the adoption of wearable health monitoring devices, has provided an important supplement to current clinical equipment. Most health monitoring devices are rigid, however, human tissues are soft. Such a difference has prohibited intimate contact between the two and jeopardized wearing comfortableness, which hurdles measurement accuracy especially during longtime usage. Here, in this work, we report a soft and stretchable photodiode that can conformally adhere onto the human body without any pressure and measure cardiovascular variables for an extended period with higher reliability than commercial devices. The photodiode used a composite light absorber consisting of an organic bulk heterojunction embedded into an elastic polymer matrix. It is discovered that the elastic polymer matrix not only improves the morphology of the bulk heterojunction for obtaining the desired mechanical properties but also alters its electronic band structure and improves the electrical properties that lead to a reduced dark current and enhanced photovoltage in the stretchable photodiode. The work has demonstrated high fidelity measurements and longtime monitoring of heat rate variability and oxygen saturation, potentially enabling next-generation wearable photoplethysmography devices for point-of-care diagnosis of cardiovascular diseases in a more accessible and affordable way.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Rigid monoclonal antibodies improve detection of SARS-CoV-2 nucleocapsid protein

Monoclonal antibodies (mAbs) are the basis of treatments and diagnostics for pathogens and other biological phenomena. We conducted a structural characterization of mAbs against the N-terminal domain of nucleocapsid protein (NPNTD) from SARS-CoV-2 using small-angle X-ray scattering and transmission electron microscopy. Our solution-based results distinguished the mAbs’ flexibility and how this flexibility affects the assembly of multiple mAbs on an antigen. By pairing two mAbs that bind different epitopes on the NPNTD, we show that flexible mAbs form a closed sandwich-like complex. With rigid mAbs, a juxtaposition of the antigen-binding fragments is prevented, enforcing a linear arrangement of the mAb pair, which facilitates further mAb polymerization. In a modified sandwich enzyme-linked immunosorbent assay, we show that rigid mAb-pairings with linear polymerization led to increased NPNTD detection sensitivity. These enhancements can expedite the development of more sensitive and selective antigen-detecting point-of-care lateral flow devices, which are critical for early diagnosis and epidemiological studies of SARS-CoV-2 and other pathogens.

60 APPLIED LIFE SCIENCES↗

Isothermal DNA Assay to Detect Drug-Resistant Tuberculosis for Point-of-Care Diagnostics

Tuberculosis (TB) and multidrug-resistant tuberculosis (MDR-TB) remain a global health issue today. There exists an unmet need for a point-of-care TB diagnostic device that is accurate and suitable for use in resource-limited, high-burden settings. This study is the first demonstration of an isothermal DNA assay to identify MDR-TB, with future applications in a low-cost mobile phone diagnostic device. Using loop-mediated isothermal amplification, three primer signatures were identified to have high specificity, high sensitivity, and low limit of detection in amplifying M. tuberculosis (MTB) DNA. The use of a dsDNA-intercalating fluorescent dye enabled real-time visualization of the reactions and identification of positive amplifications. Moreover, the assay employs the addition of peptide nucleic acid (PNA) clamps to inhibit the amplification of drug-susceptible MTB DNA and allow the amplification of drug-resistant MTB DNA. Study results showed that combinations of two primer signatures and three PNA clamps inhibit the amplification of drug-susceptible MTB DNA. Results further showed that a relatively high concentration of PNA clamp relative to DNA template is required for inhibition. In future work, PNA clamp design will be improved to increase inhibition of drug-susceptible MTB DNA reactions. Additionally, the effects of the clamps on drug-resistant MTB DNA will be investigated; no amplification is expected.

59 BASIC BIOLOGICAL SCIENCES↗

Using CRISPR/Cas13a technologies to detect miRNA [DOE SULI Internship Report]

Micro ribonucleic acids (miRNA) give our immune systems the ability to recognize viruses and other pathogens by their complementary single-stranded RNA (ssRNA) produced in the reproduction of the pathogen in our cells. When miRNA of a specific sequence is detected in a cell sample, it can be assumed that the immune system is activated and attempting to track down the infection. This pathway can be utilized to diagnose infection from a pathogen before the individual even develops symptoms, aiding in early disease detection and proper treatment. One of the ways that we can detect miRNA is through an assay of clustered regularly interspaced short palindromic repeats or “CRISPR” and the bacterial protein Cas13a. This report details discoveries made while attempting to optimize this assay for miRNA detection. After looking at several different factors within the assay, it was determined that some factors, such as reporter type and metallic ion concentration, are more impactful on the overall assay sensitivity than other factors, such as the overall concentration of Cas13a, CRISPR RNA (crRNA), or ssRNA reporter. It was also discovered that different sequences with different lengths require renewed optimization efforts, as each target has a unique binding affinity determined by the sequence length and composition. This information is crucial in the development of point of care molecular detection devices as they become sensitive enough to identify pathogens before they spread.

59 BASIC BIOLOGICAL SCIENCES↗

rHEALTH Laboratory Analyzer - ISS Increment 66 Tech Demo

A multilateral, web-based symposium, featuring ISS Increment 66 investigations will be held on December 14, 15 and 16, 2021 beginning at 0600 CST each day. The purpose of this event is for Principal Investigators to present their science objectives, testing approach, and measurement methods to agency scientists, managers, and other investigators. Participation is encouraged to gather a global picture of the science planned to be performed on ISS during Increment 66. Please note that only Increment 66 new investigations and those that have not been covered by previous science symposia will be included. We will be in touch with the investigations’ POCs to confirm the presentations and identify the speakers as we develop the preliminary agenda for the Symposium. The agenda and additional details will be distributed prior to the symposium. Presentations will be organized by discipline and will be allotted 15 minutes to highlight the main contributions of their experiment. There will be a short question and answer period after each discipline group session is complete. Please include back-up material as needed. The presentations may be made available to ISS crew members as review material for on-orbit science preparation and/or public outreach activities. Therefore, please ensure a comprehensive presentation (additional back-up material may be provided). The presentations should briefly cover the following: - Science background and hypothesis - Investigation goals and objectives - Measurement approach - Importance and reason for ISS - Expected results and how they will advance the field - Earth benefits/spin-off applications Please note that all presentations and discussions should be limited to content approved for export and information that can be shared with participants and the general public.

Laboratory Analysis↗

Single Nanopores in Silicon Nitride Membranes with Applications to Viral Sensing

While current viral sensing methods are extremely sensitive, there is still a need for platforms capable of detecting engineered viruses and being integrated into device architectures for point-of-care assessments. Nanopores could provide a single pathway to achieve these goals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗