Search NASA⌕ Search

SEARCH · Search NASA

Results for “poisoning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Cadmium poisoning of oxygen reduction on platinum electrode in potassium hydroxide

Experiment with a rotating disk and ring apparatus showed no poisoning by cadmium in 8.5 M KOH, alone or with Cl(-) or CO3(=). Poisoning does not occur either in 0.1 M KOH supernatant at CdO, but a partially reversible poisoning results from .0001 M CdCl2 and traces of fatty acid are present. Evidence indicates that the catastrophic poisoning affects the four-electron O2 reduction more than it does the one-electron H3O(+) discharge.

Miller, R. O.↗

Modeling for CO poisoning of a fuel cell anode

Poisoning losses in a half-cell in the 110-190 C temperature range have been measured in 100 wt pct H3PO4 for various mixtures of H2, CO, and CO2 gases in order to investigate the polarization loss due to poisoning by CO of a porous fuel cell Pt anode. At a fixed current density, the poisoning loss was found to vary linearly with ln of the CO/H2 concentration ratio, although deviations from linearity were noted at lower temperatures and higher current densities for high CO/H2 concentration ratios. The surface coverages of CO were also found to vary linearly with ln of the CO/H2 concentration ratio. A general adsorption relationship is derived. Standard free energies for CO adsorption were found to vary from -14.5 to -12.1 kcal/mol in the 130-190 C temperature range. The standard entropy for CO adsorption was found to be -39 cal/mol per deg K.

Dhar, H. P.↗

Lead poisoning: An overview

A problem that should be of great concern to all of us is the lead poisoning of children. First, I would like to present a short overview concerning the reasons everyone should care about lead poisoning, then discuss the history of lead poisoning, what is happening today across the country, and the future.

Gendel, Neil↗

Compatibility of refractory materials for nuclear reactor poison control systems

Metal-clad poison rods have been considered for the control system of an advanced space power reactor concept studied at the NASA Lewis Research Center. Such control rods may be required to operate at temperatures of about 140O C. Selected poison materials (including boron carbide and the diborides of zirconium, hafnium, and tantalum) were subjected to 1000-hour screening tests in contact with candidate refractory metal cladding materials (including tungsten and alloys of tantalum, niobium, and molybdenum) to assess the compatibility of these materials combinations at the temperatures of interest. Zirconium and hafnium diborides were compatible with refractory metals at 1400 C, but boron carbide and tantalum diboride reacted with the refractory metals at this temperature. Zirconium diboride also showed promise as a reaction barrier between boron carbide and tungsten.

Sinclair, J. H.↗

Sulfur poisoning of hydrocarbon oxidation by palladium

Using a differential bed recycle reactor the oxidation of ethane and diethyl ketone by a Pd catalyst was studied at the 0-30 ppm level in air. In both cases first order kinetics were observed. The ethane oxidation rate was characterized n the Arrhenius form by a pre-exponential of 1.0 x 10 to the 8th power cm/sec and an E sub a of 27 kcal/mole. The diethyl ketone oxidation rate was characterized by a pre-exponential of 5.7 x -1000 cm/sec and E sub a of 14 kcal/mole. Poisoning of ethan oxidation was also investigated by hydrogen sulfide and to a smaller extent by the refrigerants Freon 22 and Gentron 142-B. Poisoning by Gentron 142-B was much more severe than by hydrogen sulfide. Kinetic experiments indicated that only the pre-exponential was changing.

Baumgartner, A. J.↗

Using Quasiparticle Poisoning To Detect Photons

According to a proposal, a phenomenon associated with excitation of quasiparticles in certain superconducting quantum devices would be exploited as a means of detecting photons with exquisite sensitivity. The phenomenon could also be exploited to perform medium-resolution spectroscopy. The proposal was inspired by the observation that Coulomb blockade devices upon which some quantum logic gates are based are extremely sensitive to quasiparticles excited above the superconducting gaps in their leads. The presence of quasiparticles in the leads can be easily detected via the charge states. If quasiparticles could be generated in the leads by absorption of photons, then the devices could be used as very sensitive detectors of electromagnetic radiation over the spectral range from x-rays to submillimeter waves. The devices in question are single-Cooper-pair boxes (SCBs), which are mesoscopic superconducting devices developed for quantum computing. An SCB consists of a small superconducting island connected to a reservoir via a small tunnel junction and connected to a voltage source through a gate capacitor. An SCB is an artificial two-level quantum system, the Hamiltonian of which can be controlled by the gate voltage. One measures the expected value of the charge of the eigenvectors of this quantum system by use of a radio-frequency single-electron transistor. A plot of this expected value of charge as a function of gate voltage resembles a staircase that, in the ideal case, consists of steps of height 2 e (where e is the charge of one electron). Experiments have shown that depending on the parameters of the device, quasiparticles in the form of "broken" Cooper pairs present in the reservoir can tunnel to the island, giving rise to steps of 1 e. This effect is sometimes called "poisoning." Simulations have shown that an extremely small average number of quasiparticles can generate a 1-e periodic signal. In a device according to the proposal, this poisoning would be turned to advantage. Depending on the wavelength, an antenna or other component would be used to couple radiation into the reservoir, wherein the absorption of photons would break Cooper pairs, thereby creating quasiparticles that, in turn, would tunnel to the island, creating a 1-e signal. On the basis of conservative estimates of device parameters derived from experimental data and computational simulations that fit the data, it has been estimated that the noise equivalent power of a device according to the proposal could be as low as 6 10(exp -22) W/Hz(exp 1/2). It has also been estimated that the spectroscopic resolution (photon energy divided by increment of photon energy) of such a device in visible light would exceed 100.

Echternach, Pierre↗

A Case of near Fatal Ammonia Gas Poisoning

A report is given of the near fatal effects of anhydrous ammonia poisoning to a repairman working on a compression room cooling system. The repairman was exposed for approximately 5 minutes to an environment of nearly 100% ammonia gas. Descriptions are given of body burns, breathing problems, and eye burns suffered by the worker.

White, E.↗

Narcosis studies and oxygen poisoning of mice

The research for a mechanism by which narcotic gases alter metabolism is reported. Possible sites of action by narcotic and anesthetic gases in isolated electron transport particles were explored. Using the relative activities of the NADH-oxygen, NADH-ferricyanide, succinate-cytochrome C and succinate-NAD oxidoreductase systems as parameters, the relative potency of volatile anesthetics were tested. Testing the relative ability of human subjects to contract and repay an oxygen debt while in the narcotic versus alert state, it was found that narcosis induced by 33% nitrous oxide increased the size of the oxygen debt contracted and the amount of oxygen required to repay it during recovery. Mice acclimatized to sea level (760 mm Hg), 5000 feet (632 mm Hg) or 15,000 feet 437 mm Hg) for from one to eight weeks were found to be more susceptible to convulsion and death as a function of altitude acclimatization when tested in hyperoxic environments. There were no reasonable explanations for the connection between hypoxia and oxygen poisoning but several practical implications for persons living at altitude are discussed.

Source record↗

Lead Poison Detection

With NASA contracts, Whittaker Corporations Space Science division has developed an electro-optical instrument to mass screen for lead poisoning. Device is portable and detects protoporphyrin in whole blood. Free corpuscular porphyrins occur as an early effect of lead ingestion. Also detects lead in urine used to confirm blood tests. Test is inexpensive and can be applied by relatively unskilled personnel. Similar Whittaker fluorometry device called "drug screen" can measure morphine and quinine in urine much faster and cheaper than other methods.

Source record↗

Sabatier Catalyst Poisoning Investigation

The Carbon Dioxide Reduction Assembly (CRA) on the International Space Station (ISS) has been operational since 2010. The CRA uses a Sabatier reactor to produce water and methane by reaction of the metabolic CO2 scrubbed from the cabin air and the hydrogen byproduct from the water electrolysis system used for metabolic oxygen generation. Incorporating the CRA into the overall air revitalization system has facilitated life support system loop closure on the ISS reducing resupply logistics and thereby enhancing longer term missions. The CRA utilizes CO2 which has been adsorbed in a 5A molecular sieve within the Carbon Dioxide Removal Assembly, CDRA. There is a potential of compounds with molecular dimensions similar to, or less than CO2 to also be adsorbed. In this fashion trace contaminants may be concentrated within the CDRA and subsequently desorbed with the CO2 to the CRA. Currently, there is no provision to remove contaminants prior to entering the Sabatier catalyst bed. The risk associated with this is potential catalyst degradation due to trace organic contaminants in the CRA carbon dioxide feed acting as catalyst poisons. To better understand this risk, United Technologies Aerospace System (UTAS) has teamed with MSFC to investigate the impact of various trace contaminants on the CRA catalyst performance at relative ISS cabin air concentrations and at about 200/400 times of ISS concentrations, representative of the potential concentrating effect of the CDRA molecular sieve. This paper summarizes our initial assessment results.

Nallette, Tim↗