Search NASA⌕ Search

SEARCH · Search NASA

Results for “polycrystalline diamond compact”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

2025 Geothermal Drilling Cost Curves Update: Preprint

Drilling activities account for 30% to 57% of the cost to develop and install a geothermal plant. Therefore, an accurate representation of the cost to drill a well is paramount in techno-economic analysis to determine the feasibility of a geothermal power project. In 2022, the National Renewable Energy Laboratory (NREL) endeavored to revise the U.S. Department of Energy (DOE) GeoVision baseline drilling cost curves due to extensive improvement in drilling rates at the Utah Frontier Observatory Research in Geothermal Energy (FORGE) demonstration site. That effort did not culminate in the recommendation of new curves because the actual project costs did not match the reported performance improvements and were at or above the GeoVision baseline. The need for another iteration of this analysis has arisen from industry record drilling performance reported by recent commercial field-scale and demonstration projects, including Fervo Energy’s Cape Station, the Utah FORGE 16B(78)-32 demonstration and the Geysers Power Company’s GDC-36 demonstration. Therefore, in this work, we have estimated the resulting industry average rate of penetration (ROP) and bit life and applied these parameters as inputs to the Well Cost Simplified model used in the GeoVision analysis. The resulting revised cost curves show a significant decline from the GeoVision baseline. For vertical wells, the magnitude of cost decline ranges between 12% and 24% while for deviated wells, cost reductions between 18% and 26% are estimated. The revised cost curves are in good agreement with actual cost data and therefore, quantify the economic impact of the utilization of (and advances in) polycrystalline diamond compact (PDC) bit technology and the application of physics-based methodologies that optimize mechanical specific energy.

15 GEOTHERMAL ENERGY↗

Experimental Investigation of Drillstring Torsional Vibration Effect on Rate of Penetration with PDC Bits in Hard Rock

Polycrystalline diamond compact (PDC) bits have shown tremendous performance compared to roller cone bits and have gained attraction in deep geothermal drilling applications. While PDC bits can reach a higher rate of penetration compared to other bits, they are more prone to drilling vibrations. The scope of this paper is to quantify the effects of drillstring torsional vibrations on PDC bit performance using a laboratory testing facility. Here, the tests were performed with three drillstring configurations to evaluate the effect of drillstring vibrations. The results showed that rigid testing overestimates the bit rate of penetration by 35% due to torsional vibrations.

15 GEOTHERMAL ENERGY↗

Comparison of Rotary and Linear Cutting Methodology in Determining Specific Cutting Energy of Granite

Abstract Single polycrystalline diamond compact (PDC) cutting is a practical technique to understand the rock–tool interactions in drag-bit-type geothermal drilling operations. This paper introduces a rotary cutting method to determine specific cutting energy (SCE) and compares it with the conventional linear cutting method. In this work, granite is selected to represent hard rock formations in geothermal drilling. Cutting tests are conducted on a Computer Numerical Control (CNC) machine with a realistic cutting speed of 12.7 m/min and several chip loads ranging from 0.08 to 0.25 mm. The cutting force is measured using a dynamometer and then converted to specific cutting energy (SCE). The results show that the rotary method produces an inverse relationship between SCE and chip load, whereas the linear method shows the opposite. As a result, the produced SCE by the rotary method tends to be lower than that of the linear method at a higher chip load at and over 0.16 mm. The difference may be attributed to the cutting configuration and associated force components.

Engineering↗

The Effects of Plasma Pre-Cracking on Drilling of Hard Rocks: A Single Insert Cutting Experiment

Abstract This paper studies the effects of plasma-induced cracks on rock cutting to support the concept of a plasma-integrated drag bit for accelerated geothermal drilling through hard rocks. For this, a single polycrystalline diamond compact (PDC) drilling technique is used in cutting granite to compare thrust and cutting forces between plasma-treated and untreated rock samples. The cracks are produced using underwater plasma at 80 J per pulse. This energy level does not produce visible damage to the rock. The cutting tests are conducted at a cutting speed of 12.7 m/min and four feed rates of 0.127, 0.201, 0.267, and 0.414 mm/s to represent actual drilling scenarios. The results show a general trend of reduction in both thrust and cutting forces for these feed rates, but the magnitude of reduction highly depends on the feed rate. The maximum force reduction of around 50% is found at the 0.267 mm/s feed rate with statistical significance. Cases with a higher force reduction are also found to have rougher surface topography, which indicates more excessive fracturing and, thus, a cracks-accelerated material removal process. This study provides initial evidence of using underwater plasma to increase the downhole drilling rate of hard rocks.

Engineering↗

ROP model for PDC bits in Geothermal drilling

Geothermal energy is a renewable source of energy, where heat extraction is preferentially balanced with the reservoir's natural heat recharge rate. The objective of this paper is to present and validate a novel rate of penetration (ROP) model for drilling hard and abrasive formations including granite formations for polycrystalline diamond compact (PDC) bits. The ROP model was developed based on a derived relationship of a threshold weight on cutter (WOC) and its corresponding depth of cut (DOC) for a single cutter. Laboratory data was used to scale the derived single cutter relationship to a full-hole ROP model for PDC bits. The ROP model includes a non-linear correlation for Phase I (inefficient drilling due to low WOB values) and a linear Phase II (efficient drilling) ROP response to WOB. The ROP model was verified using measured drilling parameter data from Utah FORGE well# 58-32 and data from Chocolate Mountains well # 17-8 in Southern California. When compared to oil and gas well drilling, geothermal drilling in granitic formations can be more difficult and complicated due to rock hardness and high temperatures. PDC bits can increase ROP and optimize drilling for these types of hard formations. This paper provides novel insight into the ROP response of PDC bits to drilling operational parameters.

15 GEOTHERMAL ENERGY↗

Fixed Bit Rotary Drilling Failure Criteria Effect on Drilling Vibration

Polycrystalline diamond compact (PDC) bit use has been expanded to geothermal drilling applications due to their improved performance in drilling compared to roller cone bits. Multiple vibration models have been developed yet and there are limited use of field data to study the ability of numerical vibration model to predict recorded vibration in the field. The objective of this paper is to evaluate the capabilities of two different rock-bit interaction models with two different ROP formulations for predicting the actual behavior seen in the field. The first model (Model-I) considers the rock-bit interaction, incorporating the effect of subsurface formation characteristics. The second model (Model-II) is a PDC bit model that uses calculated threshold weight-on-cutter (WOCt) to study the interaction of the bit with the rock surface. The models, which couple the drill stem axial and torsional motions, are solved numerically using the fourth-order Runge-Kutta method and compared with recorded downhole drilling data from the Chocolate Mountain Aerial Gunnery Range (CMAGR) geothermal well located in California. An 8–½" PDC bit with 8 blades was modeled and vibration simulation was performed to investigate stick-slip vibrations at 1400 ft. depth. Simulation results using field data indicate that Model-II encounters a low range of stick-slip severity (SSV) as compared to Model-I, which is in the moderate range. Comparison with the field value for SSV shows Model-II is the best representative of the field case for this depth. The sensitivity analysis shows that results are sensitive to model constants making prediction of SSV from models uncertain.

15 GEOTHERMAL ENERGY↗

Evaluation of Drilling Performance at The Geysers with Machine Learning Methods Using Geologic Data

A recent well, GDC-36, was drilled in The Geysers Geothermal Field served in a Department of Energy-industry to demonstrate improved drilling performance with polycrystalline diamond compact (PDC) bits. Both PDC and roller cone drill bits were used to drill this well. Key challenges encountered during drilling included lost circulation in the mud-drilled section, and bit damage interfacial severity in the deeper, air-drilled section. The objective of this study is to evaluate the drilling performance in relation to the local geological characteristics using machine learning methods. By applying K-clustering to the sonic log data, we were able to identify areas correlated with measured lost circulation. Also, the boundaries defined by clustering of the mineralogical and lithological data from the mud logs correlate well with interfacial severity during drilling. A random forest model was employed to build correlation between drilling data and rock strength. The confined compressive strength (CCS) of the rock in the training of the machine learning model was inferred from the dipole sonic log. The R-squared of the testing data is 0.78, and the RMSE (Root Mean Squared Error) is 0.06. The trained model was used to forecast rock strength for the section where sonic log data are not available. CCS could also be inferred from mud logs provided the relationship between mineralogy and rock strength is established through core testing data.

15 GEOTHERMAL ENERGY↗

Shallow Geothermal Resources for Cooling Applications at the University of Hawai'i

Drilling activities account for 30% to 57% of the cost to develop and install a geothermal plant. Therefore, an accurate representation of the cost to drill a well is paramount in techno-economic analysis to determine the feasibility of a geothermal power project. In 2022, the National Renewable Energy Laboratory (NREL) endeavored to revise the U.S. Department of Energy (DOE) GeoVision baseline drilling cost curves due to extensive improvement in drilling rates at the Utah Frontier Observatory Research in Geothermal Energy (FORGE) demonstration site. That effort did not culminate in the recommendation of new curves because the actual project costs did not match the reported performance improvements and were at or above the GeoVision baseline. The need for another iteration of this analysis has arisen from industry record drilling performance reported by recent commercial field-scale and demonstration projects, including Fervo Energy's Cape Station, the Utah FORGE 16B(78)-32 demonstration and the Geysers Power Company's GDC-36 demonstration. Therefore, in this work, we have estimated the resulting industry average rate of penetration (ROP) and bit life and applied these parameters as inputs to the Well Cost Simplified model used in the GeoVision analysis. The resulting revised cost curves show a significant decline from the GeoVision baseline. For vertical wells, the magnitude of cost decline ranges between 12% and 24% while for deviated wells, cost reductions between 18% and 26% are estimated. The revised cost curves are in good agreement with actual cost data and therefore, quantify the economic impact of the utilization of (and advances in) polycrystalline diamond compact (PDC) bit technology and the application of physics-based methodologies that optimize mechanical specific energy.

building cooling↗