Search NASA⌕ Search

SEARCH · Search NASA

Results for “polymer chain conformation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Field Effect Transistor Behavior in Electrospun Polyaniline/Polyethylene Oxide Nanofibers

Novel transistors and logic devices based on nanotechnology concepts are under intense development. The potential for ultra-low-power circuitry makes nanotechnology attractive for applications such as digital electronics and sensors. For NASA applications, nanotechnology offers tremendous opportunities for increased onboard data processing, and thus autonomous decision-making ability, and novel sensors that detect and respond to environmental stimuli with little oversight requirements. Polyaniline (PANi) is an intriguing material because its electrical conductivity can be changed from insulating to metallic by varying the doping levels and conformations of the polymer chain, and when combined with polyethylene oxide (PEO), can be formed into nanofibers with diameters ranging from approximately 50 to 500 nm (depending on the deposition conditions). The initial goal of this work was to demonstrate transistor behavior in these nanofibers, thus creating a foundation for future logic devices.

Miranda, Felix A.↗

Field Effect Transistor Behavior in Electrospun Polyaniline/Polyethylene Oxide Demonstrated

Novel transistors and logic devices based on nanotechnology concepts are under intense development. The potential for ultra-low-power circuitry makes nanotechnology attractive for applications such as digital electronics and sensors. For NASA applications, nanotechnology offers tremendous opportunities for increased onboard data processing, and thus autonomous decisionmaking ability, and novel sensors that detect and respond to environmental stimuli with little oversight requirements. Polyaniline/polyethylene oxide (PANi/PEO) nanofibers are of interest because they have electrical conductivities that can be changed from insulating to metallic by varying the doping levels and conformations of the polymer chain. At the NASA Glenn Research Center, we have observed field effect transistor (FET) behavior in electrospun PANi/PEO nanofibers doped with camphorsulfonic acid. The nanofibers were deposited onto Au electrodes, which had been prepatterned onto oxidized silicon substrates. The preceding scanning electron image shows the device used in the transistor measurements. Saturation channel currents are observed at surprisingly low source/drain voltages (see the following graph). The hole mobility in the depletion regime is 1.4x10(exp -4)sq cm/V sec, whereas the one-dimensional charge density (at zero gate bias) is calculated to be approximately 1 hole per 50 two-ring repeat units of polyaniline, consistent with the rather high channel conductivity (approx.10(exp -3) S/cm). Reducing or eliminating the PEO content in the fiber is expected to enhance device parameters. Electrospinning is thus proposed as a simple method of fabricating one-dimensional polymer FET's.

Mueller, Carl H.↗

Monte Carlo lattice models for adsorbed polymer conformation

The adhesion between a polymer film and a metal surface is of great technological interest. However, the prediction of adhesion and wear properties of polymer coated metals is quite difficult because a fundamental understanding of the polymer surface interaction does not yet exist. A computer model for the conformation of a polymer molecule adsorbed on a surface is discussed. The chain conformation is assumed to be described by a partially directed random walk on a three dimensional simple cubic lattice. An attractive surface potential is incorporated into the model through the use of a random walk step probability distribution that is anisotropic in the direction normal to the attractive surface. The effects of variations in potential characteristics are qualitatively included by varying both the degree of anisotropy of the step distribution and the range of the anisotropy. Polymer conformation is characterized by the average end to end distance, average radius of gyration, and average number of chain segments adsorbed on the surface.

Good, B. S.↗

Determination of physical and chemical states of lubricants in concentrated contacts, part 1

A Fourier emission infrared microspectrometer, set up on a vibration-proof optical table and interfaced to a dedicated minicomputer, was used to record infrared emission spectra from elastohydrodynamic bearing contacts. Its range was extended to cover the entire mid-infrared from 2 to 15 micron. A series of experiments with 5P4E polyphenyl ether showed the existence of a temperature gradient through the lubricant in an ehd contact, which is perpendicular to the flow direction. The experiments also show marked polarization of some of the spectral bands, indicating a molecular alignment. Alignment is less evident at high pressure than at low pressure. To account for this behavior, a model is suggested along the lines developed for the conformational changes observed in long-chain polymers when subjected to increased pressure--to accommodate closer packing, molecules become kinked and curl up. Experiments with a traction fluid showed periodic changes of flow pattern associated with certain spectral changes. These observations will be studied further. A study by infrared attenuated total reflection spectrophotometry was undertaken to determine whether gamma irradiation would change polyethylene wear specimens. The results were negative.

Lauer, J. L.↗

Extended chain crystals of linear high polymers.

Studies of extended chain crystals carried out over the last 10 years have been reviewed. Crystallization in an extended chain conformation is possible either by chain folding followed by extension in the solid state, or by crystallization during polymerization. The equilibrium isometric crystal habit is only rarely exhibited. Crystals which derive from folded chain macroconformation by subsequent chain extension have lamellar habit, crystals which crystallize during polymerization often show fibrillar habit because of nucleation limitation. The morphology of extended chain crystals is analogous to folded chain crystals. Their properties have been shown to be close to the extrapolated equilibrium properties.

Wunderlich, B.↗

Simulation studies for surfaces and materials strength

Computer simulation studies were conducted to investigate materials properties. All the calculations were carried out using atomic level simulation techniques which are based on semiempirical or model functions. During this project, functions with varying degrees of complexity were derived and employed in simulations. Investigations include covalently bonded materials as well as systems involving metal atoms. For small clusters calculated results provided information on various energy- and structure-related properties along with vibrational characteristics. Also, energy barriers for configurational transitions were calculated for selected cases. Simulation calculations for surfaces produced new results in areas related to surface energies, reconstructions and relaxations, surface defects, surface stresses as well as adsorption and nucleation processes. Simulations were also performed on bulk materials. Calculated results provided an atomic level understanding on energetics and structures of point defects, crystal stability, elastic properties, and materials strength for various systems. Calculations involving polymeric materials include studies of polar polymer melts and polymer/solid interfaces. Simulations employing specially developed codes provided significant information about energetics and conformational characteristics of different polymeric chains.

Halicioglu, Timur↗

13C and 1H NMR (Nuclear Magnetic Resonance) studies of solid polyolefines

The basis of H-1 and C-13 high-resolution NMR investigations of solid polymers is outlined. The C-13 NMR spectra of solid syndiotactic and isotactic polypropene are discussed and their interpretation in terms of conformation and chain-packing effects are reviewed. The effects of decreasing temperature on the C-13 high-resolution spectrum of an annealed sample of isotactic polypropene is described and interpreted in terms of the crystal structure. The question of the proportion of the sample giving rise to C-13 signals is addressed and some results reported. The main cause for observing only part of the total sample is shown to be the H-1 rotating frame spin-lattice relaxation behavior. The H-1 spin-lattice relaxation and spectral characteristics of a number of polyolefin samples are summarized and the role of spin-diffusion discussed.

Cudby, M. E. A.↗

Flexible Polyimide Aerogels Derived From Use of Neopentyl Spacer in Backbone

Polyimide aerogels have gained much attention in the last decade due to their highly porous structure with low density, low dielectric constant, good mechanical properties and thermal stability. They are desirable for many aerospace and commercial applications including lightweight substrates for antennas for aerospace vehicles, due to the low dielectric constant, approaching one as density decreases. However, with only aromatic diamines in the backbone, the aerogels are flexible only as very thin films, nominally 0.5 mm thick. A more flexible aerogel substrate would allow them to be used as conformal antennas, which would reduce drag and also save space in aerospace vehicles. In this research, we demonstrate that the flexibility can be increased by substituting the aromatic diamines typically used in polyimide aerogels with 1,3-bis(4-aminophenoxy)-2, 2-dimethylpropane (BAPN), which contains a flexible neopentyl spacer group. Using the aliphatic diamine, BAPN, leads to aerogels with a high bend radius even when the aerogels are 2-3 mm thick. Twenty different formulations of polyimide aerogels were synthesized from 3,3’,4,4’-biphenyltetracarboxylic dianhydride (BPDA) and a combination of BAPN and 2,2’-dimethylbenxidine (DMBZ), and cross-linked with 1,3,5-triaminophenoxybenzene (TAB) to understand the effect of polymer concentration, oligomer chain length and concentration of BAPN on the properties of the aerogels. Aerogels made using 50 mol % BAPN with n of 45 and 7 wt % polymer possessed the best combination of properties conducive to use as a flexible substrate for conformal antennas, including low density, good hydrophobicity, low shrinkage with high surface area, a one-inch bend radius in aerogels up to 3 mm thickness, and a dielectric constant of 1.11.

polyimide aerogels↗

Molecular deformation and stress-strain behavior of poly(bisphenol-A-diphenyl sulfone)

The strain-birefringence response of poly(bisphenol-A-diphenyl sulfone) is found to be independent of temperature at temperatures below -100 C; at higher temperatures, the response becomes slightly dependent on temperature, with lower birefringence seen at higher temperatures. The stress-strain behavior and the stress-birefringence response both depend on temperature over the entire testing temperature range (-179 C to 150 C) studied; this dependence, however, is not pronounced. The evidence is seen as suggesting that the polymer molecules respond to deformation by undergoing conformational rearrangements; the mode of the molecular deformation remains unchanged for temperatures of -100 C or lower. At higher temperatures, the average length of the chain segments involved in the rearrangement increases. The stress-strain response is attributed mainly to chain orientation. The entropic contribution deriving from chain orientation at temperatures below -100 C is still substantial. The modest temperature dependence of the stress-strain response suggests that the energy barriers for the chain segments involved in the rearrangement are relatively low.

Hong, S.-D.↗

TPSAS-NF1676L-34417-DND

A boron nitride nanotube (BNNT), an electrically-insulating counterpart of a carbon nanotube (CNT), is a great nanofiller candidate for ferroelectric polymeric nanocomposites due to BNNT?s exceptional properties in piezoelectricity, thermal stability, mechanical strength, and radiation shielding capability. Fast and high-yield polar crystallization of polyvinylidene fluoride (PVDF) was accomplished by incorporating BNNTs as a nucleating agent. As-fabricated BNNT-PVDF nanocomposites were characterized by Fourier-transform infrared spectroscopy (FTIR), wide-angle X-ray diffraction (XRD), and differential scanning calorimetry (DSC) to identify and quantify chain conformations. Besides, piezoelectric constants, d33 of BNNT-PVDF nanocomposites were measured and compared with that of a mechanically drawn beta phase polar PVDF. The polar transformation due to BNNT incorporation has a great advantage over conventional beta or gamma transformation methods that require (1) mechanical drawing often resulting in defects or (2) high-temperature annealing for an extended time. In addition to the fast polar crystallization, BNNTs had a role of reinforcement of the polymer matrix. The improved Young?s modulus and electromechanical coupling coefficient of BNNT-PVDF nanocomposites indicated potential applications in energy harvesting under harsh environments such as large deformation, wide temperature cycles, and high radiation.

Dongwon Lee↗

Rational Design of Nanoplasmonic Array Geometries for Biosensing

Background: Molecular diagnostics provide early and accurate diagnosis, which is essential for the prevention and treatment of infectious as well as chronic diseases. These tests are designed to detect disease-specific bioanalytes such as nucleic acid (DNA or RNA) or protein (antigens, antibodies) biomarkers. In the context of infectious disease diagnosis, nucleic acid-based detection methods are known to provide more specific and sensitive results. Here, the presence of a unique sequence belonging to the pathogenic genomic material is targeted to identify species, organism, genera and/or antimicrobial resistant gene markers. The majority of the common nucleic acid based diagnostic techniques require amplification (polymerase chain reaction, isothermal amplification etc.) of the pathogenic genetic material prior to detection impacting diagnostic speed, complexity, and cost thereby limiting ease of use. Thus, the development of simplified nucleic acid-based diagnostics that can be even used in resource-poor settings may hugely benefit patients across the globe. Nanopath is a molecular diagnostics company utilizing a solid-state nanosensor to enable sequence-specific detection of target nucleic acids without the need of amplification. These nanostructures enable ultra-sensitive biomarker detection using geometric, feature-dependent properties highly dependent on the local dielectric environment, allowing them to be sensitive to low concentration binding events. This paper describes an application of this approach to provide highly relevant clinical information within a single doctor’s office visit. Intro: The Nanopath team is in collaboration with NASA (National Aeronautics and Space Administration) and NIST (National Institute of Standards and Technology) to push the bounds of the fundamental physics associated with their biosensing platform. The ability of metals to support electromagnetic surface waves gives rise to surface plasmons when optically illuminated. This property, and its strong sensitivity to changes in the local refractive index, allows for the use of metal nanoparticles as ultra-sensitive transducers. In prior work by members of this team, ensembles of randomly oriented nanoparticles (i.e., colloidal nanorods dispersed on chip) were employed for sequence-specific nucleic acid sensing (1-3). While these particle sensors have the advantage of rapid fabrication, they suffer from low sensitivity and quality factor due to the random particle dispersity. In contrast, in this study we employ ordered array nanoparticle ensembles which can be used to improve sensor sensitivity and figure-of-merit. Study Methods Overview: In this talk, we detail the results of sensing experiments and computational simulations to outline a rational design of the structure of these plasmonic nanoparticle arrays for biomolecular sensing. Through simulation and experiment, we iteratively tailor nanostructure dimension to provide high quality signal and large resonance shifts upon modeled nucleic acid binding. In particular, full-wave electromagnetic simulations were conducted using Lumerical photonic simulation software in which periodic boundary conditions were applied in the x- and y- dimensions for each of the nanoplasmonic sensor geometries. To simulate the resonance response to changes in the bulk solution in contact with the sensor surface, the refractive index of the surrounding media was changed appropriately. Nucleic acid hybridization events were modeled using either using spherical structures approximating the relevant radius of genomic material as estimated by polymer models, or as conformal layers with the known refractive indices for nucleic acids. On the basis of initial simulations, nanosensors were fabricated using traditional electron-beam lithography protocols at NIST. To evaluate consensus between simulations and experiments, bulk sensing experiments were carried out in which the resonance peaks were obtained by submerging the sensors in refractive index standards. Key nanosensor characteristics including resonance peak locations, resonance peak shifts as a function of refractive index, and figure of merit (FOM) of extinction curves were examined between the experimental and simulation results prior to proceeding with simulations on additional geometries and more complex solution conditions, and further device fabrication. This iterative process is repeated toward a rational design of nanoplasmonic array geometries for biosensing optimizing response for targeted disease detection. In summary, this study puts forth a methodology for rational design and characterization of regularly spaced nanoparticle arrays for optics-based biosensing. The results of this study will allow for more informed design of nanostructure geometries towards sequence-specific nucleic acid detection. These improved designs have the potential to improve clinical sensitivity and limit-of-detection across disease indication.

sensor↗