Visualization, understanding, and mitigation of process-induced-membrane irregularities in gas diffusion electrode-based polymer electrolyte membrane fuel cells

Polymer electrolyte membrane fuel cells (PEMFC) show substantial promise for their application in electric vehicles. For large-scale manufacturing of PEMFCs, roll-to-roll coated gas-diffusion-electrodes (GDE) offer certain advantages over other production pathways. Procedures including hot pressing and coating an ionomer overlayer may be necessary for this manufacturing pathway to enable a suitable catalyst layer/membrane interface. The same procedures may potentially introduce membrane irregularities, especially when thin membranes are used. Limited understanding exists regarding if and to what extent such irregularities impact PEMFC performance and lifetime, and therefore be considered defects. In this study, NREL's customized fuel cell hardware that enables quasi in-situ infrared (IR) thermography studies was utilized to visualize spatial hydrogen crossover and identify membrane irregularities that originated from the GDE-based MEA fabrication process. The structure of these membrane irregularities was investigated by scanning electron microscopy (SEM) and its impact on initial H2/air performance was determined. Accelerated stress testing (AST) revealed that these irregularities develop into failure point locations. These results were validated across many MEAs with identified process-induced membrane irregularities. By selecting specific gas diffusion media properties and by fine tuning the MEA hot pressing parameters, the formation of such membrane irregularities was mitigated.

08 HYDROGEN↗

Tailoring electrode microstructure via ink content to enable improved rated power performance for platinum cobalt/high surface area carbon based polymer electrolyte fuel cells

Improvements in polymer electrolyte fuel cell (PEFC) electrode performance have primarily focused on catalyst and ionomer developments, marginalizing the importance of catalyst ink formulation. In this study, the effect of ink formulation is examined across a series of cathodes comprised of PtCo supported on high surface area carbon (PtCo/ HSC ) and Nafion ionomer using an array of in situ electrochemical and ex situ characterization techniques. In contrast to prior work on Pt/Vu systems, ink water content had little effect on the electrochemically determined ionomer coverage for the PtCo/HSC electrocatalyst examined here. Characterization using nano-scale resolution X-ray computed tomography (nano-CT) demonstrated that water-rich ink formulations lead to a reduction in aggregate size (ionomer + PtCo/HSC), improving local O 2 transport. This understanding, combined with the use of a commercially-available electrocatalyst was used to produced state-of-the-art membrane electrode assemblies with Pt loadings of 0.03/0.08 mg Pt /cm 2 on the anode and cathode respectively, having; i) > 1 A/mg Pt (0.9 V iR-free , 150 kPa, 80 °C, 100% RH, H 2 /O 2 ), ii) 320 mA/cm 2 at 0.8 V, 150 kPa, 80 ° C, 100% RH, H 2 /Air), and iii) > 1 W/cm 2 elec at rated power (0.67 V, 250 kPa, 94 °C, 65% RH, H 2 /Air) or < 0.11 g Pt /kW rated .

25 ENERGY STORAGE↗

An Analysis of the Impact of Particle Growth on Transport Losses in Polymer-Electrolyte Fuel Cells

Voltage cycling causes catalyst nanoparticles in polymer-electrolyte fuel cells to grow. The concomitant loss of interfacial area results in larger kinetic, transport, and possibly ohmic overpotentials. This paper uses recently published experimental data and mathematical models to investigate the evolutions of transport and ohmic resistances to platinum nanoparticles located on the surface and inside the micropores of carbon black supports. Resistance to oxygen transport rises as surface area declines primarily because the flux to each remaining larger platinum particle increases. The path lengths governing oxygen diffusion to surface and buried platinum sites also increase as nanoparticles grow. Platinum nanoparticles on the surface become relatively less favorable as voltage cycling proceeds because they grow faster than platinum in micropores. Because voltage cycling causes total interfacial area to decline, and the fraction located inside micropores to increase, nanoscale ohmic losses increase as a catalyst layer decays. The practical importance of this effect is difficult to discern because proton conductivity in carbon micropores is not well characterized.

07 ISOTOPE AND RADIATION SOURCES↗

Standardized protocols for evaluating platinum group metal-free oxygen reduction reaction electrocatalysts in polymer electrolyte fuel cells

Platinum group metal (PGM)-free electrocatalysts for the oxygen reduction reaction at the polymer electrolyte fuel cell cathode have shown substantial improvements in activity—especially those derived from transition metals, nitrogen and carbon. However, their stability and durability remain insufficient. A key to enabling future improvements and performance comparisons lies in the development of test protocols that are relevant to the operating conditions of the fuel cell cathode, can be completed within a reasonable time and are ubiquitously adopted. Here we propose and validate such protocols, designed with special attention to typical catalyst degradation mechanisms of PGM-free catalysts. The results of the cross-laboratory validation study using two different catalysts attest to the strength and feasibility of the proposed approach. We hope that the information provided here can serve as a broad and effective platform for assessing the performance and durability of PGM-free catalysts for polymer electrolyte fuel cells.

25 ENERGY STORAGE↗

Mapping of Heterogeneous Catalyst Degradation in Polymer Electrolyte Fuel Cells

Pt catalysts in polymer electrolyte fuel cells degrade heterogeneously as the catalyst particles are exposed to local variations throughout the catalyst layer during operation. State-of-the-art analytical techniques for studying degradation of Pt catalysts do not possess fine spatial resolution to elucidate such non-uniform degradation behavior at a large electrode level. A new methodology is developed to spatially resolve and quantify the heterogeneous Pt catalyst degradation over a large area (several cm ) of aged MEAs based on synchrotron X-ray microdiffraction. PEFC single cells are aged using voltage cycling as an accelerated stress test and the degradation heterogeneity at a micrometer length scale is visualized by mapping Pt catalyst particle size after voltage cycling. It is demonstrated in detail that the Pt catalyst particle size growth is non-uniform and follows the flow field geometry. The Pt particle size growth is greater in the area under the flow field land, while it is minimal in the area under the flow field channel. Additional non-uniformity is observed with the Pt particle size increasing more rapidly at the air outlet area than the Pt particle size at the inlet area.

36 MATERIALS SCIENCE↗

Modeling Oxygen Transport in High Surface Area Carbon Supports for Polymer-Electrolyte Fuel Cells

Here, an analytical model for resistance to oxygen transport in air electrodes containing carbon black supports with high surface area was developed by combining a Thiele modulus—effectiveness factor approach at the agglomerate scale (~150 nm) with nanoscale diffusional resistance in carbon micropores/pits (~5 nm). This paper extends an earlier model for transport resistance to platinum nanoparticles on low surface area carbon. Differences in transport resistances between catalyst layers with high and low surface area carbon blacks predicted by the model with reasonable geometric dimensions and physical properties are consistent with experimental observations.

08 HYDROGEN↗

Utilizing ink composition to tune bulk-electrode gas transport, performance, and operational robustness for a Fe-N-C catalyst in polymer electrolyte fuel cell

With lower site density and turnover frequency, platinum group metal (PGM)-free catalysts based electrodes are often greater than 50 mu m thick in order to increase performance across the fuel cell operating range. Consequently, PGM-free electrodes have an additional bulk electrode transport resistance beyond the local or aggregate level transport in thin platinum-based electrodes. In parallel to the development of more active and durable PGM-free catalysts, advancements in understanding the interplay between PGM-free electrode fabrication, bulk-electrode transport, proton conductivity and performance are needed. Here, the relationship between ionic and gas phase transport through the electrode thickness is modified by adjusting electrocatalyst and ionomer flocculation/interaction at the ink level. The influence of the ink composition (water/n-propanol content) is examined via various in-situ electrochemical and ex-situ characterization techniques and the resulting electrode structure/performance relationship contrasted with electrode performance robustness across a range of relative humidity (RH). For the electrocatalyst examined here, a water-rich (82 wt% H2O) ink formulation was favorable for operation at high RH due to improved molecular diffusion through larger electrode pores. In contrast, the improved interactions between ionomer and electrocatalyst enabled a more robust electrode and higher performance during low RH operation for the 50 wt% H2O content ink.

08 HYDROGEN↗

Electrode ink deposition system for high-throughput polymer electrolyte fuel cell

Systems for creating electrodes for polymer electrolyte membrane fuel cells include an XY stage having a heated vacuum table physically coupled to the XY stage. The vacuum table has a working face with a plurality of channels formed therein to communicate vacuum pressure from a port coupled to a vacuum source to the channels. A sheet of perforated heat-conductive material has staggered holes configured to evenly distribute the vacuum pressure from the channels through the perforated sheet. A heat-conductive wire mesh is placed over the perforated sheet, and has openings smaller than the staggered holes such that a membrane material placed on the wire mesh is not deformed by the vacuum pressure. A nanopipette or micropipette coupled to a pump is configured to deposit electrode ink onto an exposed surface of the membrane material as the controller device causes the XY stage to move the vacuum table to control deposition of the electrode ink onto the surface of the membrane material.

Park, Jae Hyung↗

Correlating the Morphological Changes to Electrochemical Performance During Carbon Corrosion in Polymer Electrolyte Fuel Cells

A mechanistic understanding of carbon corrosion in polymer electrolyte fuel cells (PEFCs) is required to design durable catalyst layers. Uncontrolled startup and shutdown of PEFCs cause electrochemical oxidation of carbon, which leads to several degradation phenomena, such as loss in electrochemical surface area (ECSA), pore structure collapse or increase in mass transport resistance. In this study, the chronology of morphological changes in the cathode catalyst layer due to carbon corrosion was identified and correlated with electrochemical performance degradation. PEFCs were subjected to the Department of Energy carbon corrosion accelerated stress test (AST) protocol. The study revealed two phases: in the initial phase (~500 AST cycles), amorphous carbon in contact with Pt nanoparticles oxidized fast. Rapid carbon loss and catalyst layer thinning occurred, but pore structure did not change significantly. Pt nanoparticles detached from the support and ECSA decreased drastically. In the second phase (~1500 AST cycles), carbon corrosion slowed down, but severe pore structure collapse was observed. Porosity and pore connectivity within the cathode catalyst layer decreased considerably. Electrochemical diagnostics corroborated this finding by showing significantly higher O2 mass transport resistance. Lastly, no significant change was observed in the concentration of oxides on the carbon surface after AST. But overall water management in the cathode catalyst layer deteriorated as the pore structure collapsed. This study provides an in-depth understanding of morphological changes during PEFC carbon corrosion AST protocol and motivates novel material design strategies to enable durable PEFCs.

catalyst layers↗

Durability of Pt-Alloy Catalyst for Heavy-Duty Polymer Electrolyte Fuel Cell Applications under Realistic Conditions

As an emerging technology, polymer electrolyte fuel cells (PEFCs) powered by clean hydrogen can be a great source of renewable power generation with flexible utilization because of high gravimetric energy density of hydrogen. To be used in real-life applications, PEFCs need to maintain their performance for long-term use under a wide range of conditions. Therefore, it's important to understand the degradation of the PEFC under protocols that are closely related to the catalyst lifetime. Alloying Pt with transitional metal improves catalyst activity. It is also crucial to understand Pt alloys degradation mechanisms to improve their durability. To study durability of Pt alloys, accelerated stress tests (ASTs) are performed on Pt-Co catalyst supported on two types of carbon. Two different AST protocols were being studied: Membrane Electrolyte Assembly (MEA) AST based on the protocol introduced by the Million Mile Fuel Cell Truck consortium in 2023 and Catalyst AST, adopted from the U.S. Department of Energy (DoE).

25 ENERGY STORAGE↗

Architecture-Based Control of Temperature Gradient-Driven Water Transport in Polymer Electrolyte Fuel Cells

Temperature gradients can move water within the porous media of a polymer electrolyte fuel cell through phase-change-induced (PCI) flow. It is critical to understand PCI flow so that control and distribution of water within a fuel cell can be accomplished. This work investigates the role of architecture, specifically anode land width, on overall cell water content and distribution in the through-plane direction. A specially-designed 4.8 cm 2 fuel cell with precise thermal boundary conditions was imaged with neutrons using two different anode flow field configurations. A new, non-dimensional thermal transport number was developed which quantifies the relative influence of PCI flow on cell water transport. It was found that anode lands larger than the cathode lands cause large thermal gradients that instigate net water flux from the cathode to the anode. An asymmetric configuration with larger anode lands was found to have large changes in water content that were strongly sensitive to cell operating conditions. The thermal transport number developed here enables deduction of the net flux condition based on operating conditions and architecture. This approach enables design of high-performance systems with balanced water management.

25 ENERGY STORAGE↗

Meso-Structured Polymer Electrolyte Fuel Cell Electrode

Increasing the utilization of Pt and Pt alloy catalysts in polymer electrolyte fuel cell cathodes is critical to improving the high power density operation, particularly at low Pt loadings. State of the art electrodes are fabricated in an ink deposition process that leads to uncontrolled electrode architecture with random aggregates of functional domains (catalyst, ionomer, and pore volume) (1). The randomness in the domains induces high tortuosity transport pathways for ions and fluids, which cause severe transport resistance during high current density operation. Thin ionomer films cause additional transport resistance and poisoning of the Pt catalyst, which becomes more significant at low Pt loadings. Reducing the amount of ionomer in the catalyst domain without affecting the ionic transport resistance is key to improving the utilization of the Pt and reducing the transport resistance at low Pt loading. Rational design of the electrode structure with controlled low tortuous ionic transport pathways could improve performance. The introduction of the ionomer pathways could also enable reduction of the ionomer volume in the catalyst domain, reducing the transport resistance. Middelmen et al. proposed electrode structures consisting of aligned components in a low tortuosity configuration to improve performance (2). In this work, we present an alternative electrode structure based on a vertically aligned array of Nafion pillars in the cathode catalyst layer, as shown in Figure 1a. Figure 1b shows the SEM image of the Nafion pillars. Furthermore, Pt supported on carbon catalyst was deposited on the Nafion pillars to fabricate a meso-structured electrode. Nafion pillars provide high conductive and low tortuous pathways for protons, reducing the effective transport distance, and enabling reduction of the ionomer binder in the catalyst domain.

25 ENERGY STORAGE↗

Novel platinum group metal-free catalyst ink deposition system for combinatorial polymer electrolyte fuel cell performance evaluation

Here, a new system for rapid and precise fabrication of polymer electrolyte fuel cell (PEFC) membrane-electrode assemblies (MEAs) is introduced to facilitate rapid testing and characterization of platinum group metal-free (PGM-free) catalysts, with minimal waste of materials, using commercial combinatorial hardware and multi-channel potentiostat. The commercial combinatorial system, designed for high-throughput catalyst activity evaluation (i.e., low overpotential and current densities) using gas-diffusion electrodes (GDEs), has been further developed to enable simultaneous evaluation of the high current density performance on air of twenty-five cathodes prepared by coating catalyst-ionomer inks directly onto the membrane using a newly-developed deposition system. A nanopipette or micropipette coupled to a precise peristaltic pump is being used for precise and even catalyst ink deposition onto the membrane in each of twenty-five circular electrodes with areas of <1 cm 2 and in the precise locations required by the commercial combinatorial MEA hardware. The automated ink deposition system is coupled with a custom-designed heated vacuum table mounted on a computer-controlled XY stage to prevent deformation of the membrane and electrode layers during ink deposition onto the membrane. This system was utilized to evaluate the impact of ionomer to catalyst ratio on the hydrogen-air fuel cell performance of the PGM-free catalyst.

25 ENERGY STORAGE↗

Recent advancements in high performance polymer electrolyte fuel cell electrode fabrication – Novel materials and manufacturing processes

The global effort to introduce polymer electrolyte fuel cells for clean and renewable energy to the market is increasing the demand for high performance, robust and affordable membrane electrode assemblies (MEAs). There is not yet a standard method for large scale production of MEAs, or the methods employed are generally unsatisfactory in terms of quality and performance. A large number of published data of newly developed catalyst and electrolyte materials, claim to improve the state of the art, but are often not fully comparable due to different experimental studies and experimental designs. This article summarizes the trends in material developments and emerging MEA-manufacturing techniques. The materials and techniques are systematically compared in terms of cell performance and scalability. Current and future scientific challenges are identified and analysed based on published findings over the past five years. Finally, the results of the cited papers have been quantitatively compared to each other and to the internal benchmarks used in each cited work to provide a complete picture of the state of the art in PEFC MEA manufacturing.

25 ENERGY STORAGE↗

Energetics of Base–Acid Pairs for the Design of High-Temperature Fuel Cell Polymer Electrolytes

The interaction energy of base–acid plays a key role in acid retention of phosphoric acid (PA)-doped polymer electrolytes under fuel cell operating conditions. Here, we investigate the energetics of proton-accepting and hydroxide-donating organic bases using density functional theory calculations. Because of their weak basicity, proton-accepting organic bases such as benzimidazole have relatively low interaction energy with the acid in the absence of water (15.3–28.0 kcal mol –1 ). Energetics of the proton-accepting base–PA complex increases by adding water, indicating that the interactions in the base–acid complex strengthen in the presence of water. On the other hand, hydroxide-donating organic bases, such as tetramethylammonium hydroxide, have high interaction energy with PA (~110 kcal mol –1 ), which remains high in the presence of water. The chemical shifts of 31P NMR support the energetics of the base–acid complexes. Overall, this study further discusses the benefit of incorporating hydroxide-donating organic bases into the polymeric structure over proton-accepting bases as a way to increase acid retention.

25 ENERGY STORAGE↗

Effect of Commercial Gas Diffusion Layers on Catalyst Durability of Polymer Electrolyte Fuel Cells in Varied Cathode Gas Environment

Gas diffusion layers (GDLs) play a crucial role in heat transfer and water management of cathode catalyst layers in polymer electrolyte fuel cells (PEFCs). Thermal and water gradients can accelerate electrocatalyst degradation and therefore the selection of GDLs can have a major influence on PEFC durability. Currently, the role of GDLs in electrocatalyst degradation is poorly studied. Here, we perform electrocatalyst accelerated stress test studies on membrane electrode assemblies (MEAs) prepared using three most commonly used GDLs. The effect of GDLs on electrocatalyst degradation is evaluated in both nitrogen (non-reactive) and air (reactive) gas environments at 100% relative humidity. In situ electrochemical characterization and extensive physical characterization is performed to understand the subtle differences in electrocatalyst degradation and correlated to the use of different GDLs. Overall, no difference is observed in the electrocatalyst degradation due to GDLs based on polarization curves at the end of life. But interestingly, MEA with a cracked microporous layer (MPL) in the GDL exhibited a higher electrocatalyst loading loss, which resulted in a lower and more heterogeneous increase in the average electrocatalyst nanoparticle size.

25 ENERGY STORAGE↗

Understanding Platinum Ionomer Interface Properties of Polymer Electrolyte Fuel Cells

A well-designed cathode catalyst layer with optimal ionomer distribution is critical to minimizing amount of Platinum (Pt) content in polymer electrolyte fuel cells (PEFCs). The impact of Pt loading, ionomer content and carbon support types on the catalyst/ionomer interface were also investigated at dry and wet conditions. Higher Pt loadings resulted in higher double layer capacity (C dl ) and similar electrochemical surface area (ECSA) due to well dispersed ionic phase material. Higher ionomer content resulted in higher ionic conductivity but also showed similar SO 3 − group coverage. High surface area (HSA) carbon support had larger ECSA and C dl at both dry and wet conditions, as less agglomerated Pt was well dispersed in the meso-pores of the support. Lower SO 3 − group coverages were observed for HSA carbon than for Vulcan carbon due to Pt particles being buried within the porous HSA carbon support. The effect of cell conditioning and voltage recovery on the PEFC cathode catalyst layer was shown to have minimal impact on SO 3 − group coverage despite a decrease in C dl and ECSA due to the size increase of Pt particles. At dry condition, a significant increases in SO 3 − group coverage were observed for all MEAs due to higher adsorptivity of ionomer in dry conditions.

25 ENERGY STORAGE↗

Carbon Corrosion in Polymer Electrolyte Fuel Cells: A Complex Interplay between Morphological Changes and Electrochemical Performance

Due to the high gravimetric energy density of hydrogen, the focus of implementation of polymer electrolyte fuel cells (PEFCs) has shifted from light duty passenger vehicles to heavy duty vehicles such as buses, trucks, locomotives and marine vessels. A mechanistic understanding of degradation is therefore necessary to improve durability and efficiency. During start-up and shut-down (SUSD) of PEFC systems, the catalyst (Pt nanoparticles embedded on carbon support) undergoes local potentials ~ 1 - 1.5 V caused by a combination of fuel (H 2 ) starvation, mixed fuel region and cell reversal. This leads to a series of degradation phenomenon including reduction in cathode catalyst layer (cCL) thickness and porosity, loss in electrochemical surface area (ECSA), ionomer degradation and loss in electrical contact, therefore resulting in severe performance loss. The convoluted relationship between these individual degradation mechanisms, their chronology and their effects on electrochemical performance are yet unresolved. Here, the complex interplay between morphological changes due to carbon corrosion and its effects on the electrochemical performance were analyzed using a combination of detailed electrochemical characterization, spectroscopy, and electron microscopy techniques.