Search NASA⌕ Search

SEARCH · Search NASA

Results for “polystyrene”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Solid polystyrene and deuterated polystyrene light output response to fast neutrons

The Neutron Imaging System has proven to be an important diagnostic in studying DT implosion characteristics at the National Ignition Facility. Here, the current system depends on a polystyrene scintillating fiber array, which detects fusion neutrons born in the DT hotspot as well as neutrons that have scattered to lower energies in the surrounding cold fuel. Increasing neutron yields at NIF, as well as a desire to resolve three-dimensional information about the fuel assembly, have provided the impetus to build and install two additional next-generation neutron imaging systems. We are currently investigating a novel neutron imaging system that will utilize a deuterated polystyrene (CD) fiber array instead of standard hydrogen-based polystyrene (CH). Studies of deuterated xylene or deuterated benzene liquid scintillator show an improvement in imaging resolution by a factor of two, but also a reduction in light output as compared to standard plastic. Tests of the relative light output of deuterated polystyrene and standard polystyrene were completed using 14 MeV fusion neutrons generated through implosions of deuterium-tritium filled capsules at the OMEGA laser facility. In addition, we collected data of the relative response of these two scintillators to a wide energy range of neutrons (1-800 MeV) at the Weapons Neutrons Research Facility. Results of these measurements are presented.

47 OTHER INSTRUMENTATION↗

Comparison of polystyrene scintillator fiber array and monolithic polystyrene for neutron imaging and radiography

The neutron imaging diagnostic at the National Ignition Facility has been operating since 2011 generating neutron images of deuterium-tritium (DT) implosions at peak compression. The current design features a scintillating fiber array, which allows for high imaging resolution to discern small-scale structure within the implosion. In recent years, it has become clear that additional neutron imaging systems need to be constructed in order to provide 3D reconstructions of the DT source and these additional views need to be on a shorter line of sight. As a result, there has been increased effort to identify new image collection techniques that improve upon imaging resolution for these next generation neutron imaging systems, such as monolithic deuterated scintillators. This work details measurements performed at the Weapons Neutron Research Facility at Los Alamos National Laboratory that compares the radiographic abilities of the fiber scintillator with a monolithic scintillator, which may be featured in a future short line of sight neutron imaging systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of film measurements and Monte Carlo simulations of dose delivered with very high-energy electron beams in a polystyrene phantom

Purpose: To measure radiation dose in a water-equivalent medium from very high-energy electron (VHEE) beams and make comparisons to Monte Carlo (MC) simulation results. Methods: Dose in a polystyrene phantom delivered by an experimental VHEE beam line was measured with Gafchromic films for three 50 MeV and two 70 MeV Gaussian beams of 4.0–6.9 mm FWHM and compared to corresponding MC-simulated dose distributions. MC dose in the polystyrene phantom was calculated with the EGSnrc/BEAMnrc and DOSXYZnrc codes based on the experimental setup. Additionally, the effect of 2% beam energy measurement uncertainty and possible non-zero beam angular spread on MC dose distributions was evaluated. Results: MC simulated percentage depth dose (PDD) curves agreed with measurements within 4% for all beam sizes at both 50 and 70 MeV VHEE beams. Central axis PDD at 8 cm depth ranged from 14% to 19% for the 5.4–6.9 mm 50 MeV beams and it ranged from 14% to 18% for the 4.0–4.5 mm 70 MeV beams. MC simulated relative beam profiles of regularly shaped Gaussian beams evaluated at depths of 0.64 to 7.46 cm agreed with measurements to within 5%. A 2% beam energy uncertainty and 0.286° beam angular spread corresponded to a maximum 3.0% and 3.8% difference in depth dose curves of the 50 and 70 MeV electron beams, respectively. Absolute dose differences between MC simulations and film measurements of regularly shaped Gaussian beams were between 10% and 42%. Conclusions: The authors demonstrate that relative dose distributions for VHEE beams of 50–70 MeV can be measured with Gafchromic films and modeled with Monte Carlo simulations to an accuracy of 5%. The reported absolute dose differences likely caused by imperfect beam steering and subsequent charge loss revealed the importance of accurate VHEE beam control and diagnostics.

07 ISOTOPE AND RADIATION SOURCES↗

First-principles investigations on ionization and thermal conductivity of polystyrene for inertial confinement fusion applications

Using quantum molecular-dynamics (QMD) methods based on the density functional theory, we have performed first-principles investigations of the ionization and thermal conductivity of polystyrene (CH) over a wide range of plasma conditions (ρ = 0.5 to 100 g/cm{sup 3} and T = 15 625 to 500 000 K). The ionization data from orbital-free molecular-dynamics calculations have been fitted with a “Saha-type” model as a function of the CH plasma density and temperature, which gives an increasing ionization as the CH density increases even at low temperatures (T < 50 eV). The orbital-free molecular dynamics method is only used to gauge the average ionization behavior of CH under the average-atom model in conjunction with the pressure-matching mixing rule. The thermal conductivities (κ{sub QMD}) of CH, derived directly from the Kohn–Sham molecular-dynamics calculations, are then analytically fitted with a generalized Coulomb logarithm [(lnΛ){sub QMD}] over a wide range of plasma conditions. When compared with the traditional ionization and thermal conductivity models used in radiation–hydrodynamics codes for inertial confinement fusion simulations, the QMD results show a large difference in the low-temperature regime in which strong coupling and electron degeneracy play an essential role in determining plasma properties. Hydrodynamic simulations of cryogenic deuterium–tritium targets with CH ablators on OMEGA and the National Ignition Facility using the QMD-derived ionization and thermal conductivity of CH have predicted ∼20% variation in target performance in terms of hot-spot pressure and neutron yield (gain) with respect to traditional model simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ionic Liquids as Additives to Polystyrene- Block -Poly(Methyl Methacrylate) Enabling Directed Self-Assembly of Patterns with Sub-10 nm Features

Polystyrene- block -poly(methyl methacrylate) (PS- b -PMMA) is one of the prototypical block copolymers in directed self-assembly (DSA) research and development, with standardized protocols in place for processing on industrially relevant 300 mm wafers. Scaling of DSA patterns to pitches below 20 nm using PS- b -PMMA, however, is hindered by the relatively low Flory–Huggins interaction parameter, $χ$. In this work, we investigate the approach of adding small amounts of ionic liquids (ILs) into PS- b -PMMA, which selectively segregates into the PMMA domain and effectively increases the $χ$ parameter and thus the pattern resolution. The amount of IL additive is small enough to result in limited changes in PS- b -PMMA’s surface and interfacial properties, thus maintaining industry-friendly processing by thermal annealing with a free surface. Three different ILs are studied comparatively regarding their compositional process window, capability of increasing $χ$, and thermal stability. By adding ~3.1 vol % of the champion IL into a low-molecular-weight PS- b -PMMA ( M n = 10.3k- b -9.5k), we demonstrated DSA on chemically patterned substrates of lamellar structures with feature sizes <8.5 nm. Compatibility of the PS- b -PMMMA/IL blends with the standardized processes that have been previously developed suggests that such blend materials could provide a drop-in solution for sub-10 nm lithography with the processing advantages of PS- b -PMMA.

36 MATERIALS SCIENCE↗

Effect of Graft Molecular Weight and Density on the Mechanical Properties of Polystyrene-Grafted Cellulose Nanocrystal Films

In this work, polymer-grafted nanoparticle (PGN) films were prepared from polystyrene (PS) grafted to rodlike cellulose nanocrystals (MxG-CNC-g-PS) with a controllable grafting density (0.03–0.25 chains/nm 2 ) and molecular weight (5–60 kg/mol). These nanorod-based PGNs are solution- and melt-processible, permitting access to one-component composite films with high nanofiller loadings (with up to 55 wt %). The impact of both grafted polymer density and molecular weight on the mechanical properties of the films was investigated and related to the polymer brush conformation: concentrated polymer brush (CPB), semidilute polymer brush (SDPB), or CPB core with SDPB corona (CPB/SDPB). The rubbery regime storage modulus (above $T_g$) showed 2 orders of magnitude increase, maximizing at a low degree of polymerization (N) and low grafting density (σ). Fracture toughness was maximized in samples with the grafted polymer in the SDPB or CPD/SDPB (higher N and relatively low σ) regime and showed enhancement relative to PS of molecular weight similar to the graft. In line with prior computation predictions, optimizing for both rubbery modulus and fracture toughness in such nanorod-based PGN films requires the polymers in the SDPB regime and CNC loading levels (ca. 50–60 wt %) that are difficult to attain in more traditional two-component CNC composites.

36 MATERIALS SCIENCE↗

Highly Contrasting Static Charging and Bias Stress Effects in Pentacene Transistors with Polystyrene Heterostructures Incorporating Oxidizable N , N '-Bis(4-methoxyphenyl)aniline Side Chains as Gate Dielectrics

Charge storage and trapping properties of polymer dielectrics govern the charge densities of adjacent semiconductors and greatly influence the on-off switching voltage (threshold voltage, V th ) of organic field-effect transistors (OFETs) when the polymers are used as gate insulators. Intentional charging of polymer dielectrics in OFETs can change V th and affect the bias stress. We describe a chemical design and fabrication protocol to construct multilayer-stack dielectrics for pentacene-based OFETs using different polystyrene (PS)-based polymers in each layer, with oxidizable N,N-bis(4-methoxyphenyl)anilino (TPAOMe)-substituted styrene copolymers in arbitrary vertical positions in the stacks. Thermal, byproduct-free crosslinking of benzocyclobutene subunits provides integrity to the multilayer structure by preventing dissolution of the previous deposited layer. Neutron reflectivity data verified the multilayer morphology. We compared the Vth shift before and after charging the stacks by application of ±100V across 0.5-1 µm total film thicknesses. Bias stress was the dominant effect in bilayer devices with a TPAOMe layer in contact with the pentacene, indicated by the direction of V th shift associated with either polarity of external electric field. In structures with no TPAOMe subunit in contact with the pentacene, when charging with -100V on top of the source and drain electrodes, electron injection from pentacene to dielectric was the major charging mechanism, again consistent with the bias stress direction. When charging with +100V, bilayer devices without TPAOMe showed little change in V th , suggesting there was no bias stress effect or charge injection in these devices for this charging polarity. For the bilayer devices with the TPAOMe layer in the bottom, and the trilayer devices with TPOMe in the middle, when +100V was applied, the V th shifts were opposite those expected from bias stress. Dipole formation or partial ionization of chargeable groups at the interface between the dielectric layers are likely polarization mechanisms in these cases. A simple analytical model supports the plausibility of these mechanisms. This work provides examples of both stabilization and shifting of V th , and therefore controlling charge carrier density, in semiconductors overlying the dielectric multilayers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Selective Plasticization of Poly (ethylene oxide) (PEO) Block in Nanostructured Polystyrene– PEO– Polystyrene Triblock Copolymer Electrolytes

The plasticization of a polymer electrolyte usually promotes its ionic conductivity but decreases its storage modulus due to the increased polymer chain flexibility. Herein, we show that such a tradeoff between the ionic conductivity and the mechanical robustness of the polymer electrolyte can be alleviated by selective plasticization of the ion-conductive block, such as poly(ethylene oxide) (PEO) in a polystyrene (PS)– PEO–PS block copolymer (SEO) electrolyte using an ether type plasticizer, tetraethylene glycol dimethyl ether (TEGDME). In this work, at maximum plasticizer loading, the room temperature ionic conductivity increases by up to 3 orders, whereas the storage modulus, G' reduces to half, is still on the order of 10 2 MPa. At above the melting temperature of the PEO block, the dynamic storage modulus, G' of the plasticized membrane surpasses its dry PS-PEO-PS counterpart. Such a phenomenon results from that, a) TEGDME co-crystallizes with PEO to promote its crystallinity and hence the storage modulus, b) TEGDME swells the amorphous PEO phase to enhance the polymer chain segmental mobility and hence ionic conductivity, and c) the PS phase remains intact from TEGDME to keep the SEO elastic.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗