Commissioning of a proton gantry equipped with dual x-ray imagers and a robotic patient positioner, and evaluation of the accuracy of single-beam image registration for this system

Purpose: To check the accuracy of a gantry equipped with dual x-ray imagers and a robotic patient positioner for proton radiotherapy, and to evaluate the accuracy and feasibility of single-beam registration using the robotic positioner. Methods: One of the proton treatment rooms at their institution was upgraded to include a robotic patient positioner (couch) with 6 degrees of freedom and dual orthogonal kilovoltage x-ray imaging panels. The wander of the proton beam central axis, the wander of the beamline, and the orthogonal image panel crosswires from the gantry isocenter were measured for different gantry angles. The couch movement accuracy and couch wander from the gantry isocenter were measured for couch loadings of 50–300 lb with couch rotations from 0° to ±90°. The combined accuracy of the gantry, couch, and imagers was checked using a custom-made 30 × 30 × 30 cm{sup 3} Styrofoam phantom with beekleys embedded in it. A treatment in this room can be set up and registered at a setup field location, then moved precisely to any other treatment location without requiring additional image registration. The accuracy of the single-beam registration strategy was checked for treatments containing multiple beams with different combinations of gantry angles, couch yaws, and beam locations. Results: The proton beam central axis wander from the gantry isocenter was within 0.5 mm with gantry rotations in both clockwise (CW) and counterclockwise (CCW) directions. The maximum wander of the beamline and orthogonal imager crosswire centers from the gantry isocenter were within 0.5 and 0.8 mm, respectively, with the gantry rotations in CW and CCW directions. Vertical and horizontal couch wanders from the gantry isocenter were within 0.4 and 1.3 mm, respectively, for couch yaw from 0° to ±90°. For a treatment with multiple beams with different gantry angles, couch yaws, and beam locations, the measured displacements of treatment beam locations from the one based on the initial setup beam registered at the gantry at 0°/180° and couch yaw at 0° were within 1.5 mm in three translations and 0.5° in three rotations for a 200 lb couch loading. Conclusions: Results demonstrate that the gantry equipped with a robotic patient positioner and dual imaging panels satisfies treatment requirements for proton radiotherapy. The combined accuracy of the gantry, couch, and imagers allows a patient to be registered at one setup position and then moved precisely to another treatment position by commanding the robotic patient positioner and delivering treatment without requiring additional image registration.

07 ISOTOPE AND RADIATION SOURCES↗

Online task-space motion control for positioner-coordinated multi-robot manufacturing systems

Incorporating multiple robotic manipulators into large-scale manufacturing systems enhances production efficiency and expands manufacturing capabilities beyond those of single-robot systems. Workpiece positioners in robotic manufacturing have demonstrated significant benefits for process optimization, but coordination strategies for multi-robot systems with shared positioners have received limited attention. This work presents a task-space coordinated trajectory-tracking control framework for multi-robot manufacturing systems, in which robots coordinate their motions within a shared, dynamic workpiece positioning frame. A workpiece positioner actively adjusts the pose of the manufactured component to enable greater operational concurrency and improve overall production efficiency. The proposed motion-coordination scheme employs a distributed and scalable architecture, supporting coordination across heterogeneous multi-robot systems. Two optimization methodologies are introduced to manage kinematic redundancies and maintain continuous, near-optimal operation throughout the manufacturing process. The first strategy exploits a task-space dimensionality reduction to achieve locally optimal configurations by leveraging symmetry-axis rotations of the tool. The second strategy utilizes the workpiece positioner to drive the coordinated robots toward stable and kinematically favorable configurations. For both optimization strategies, multiple objectives are defined to improve key performance metrics, including manipulability, configuration consistency, proximity to mechanical limits, and motion efficiency. Addressing a key limitation of existing coordination approaches, the framework is designed around online setpoint modification, allowing coordinated robots to respond effectively to in-situ process feedback. The proposed control framework is validated using the Robot Operating System (ROS) middleware on a combination of physical and simulated multi-robot system hardware.

Arbogast, Alex [ORNL] (ORCID:0000000154740723)↗

SDSS-V Algorithms: Fast, Collision-free Trajectory Planning for Heavily Overlapping Robotic Fiber Positioners

Robotic fiber positioner (RFP) arrays are becoming heavily adopted in wide-field massively multiplexed spectroscopic survey instruments. RFP arrays decrease nightly operational overheads through rapid reconfiguration between fields and exposures. In comparison to similar instruments, SDSS-V has selected a very dense RFP packing scheme where any point in a field is typically accessible to three or more robots. This design provides flexibility in target assignment. However, the task of collisionless trajectory planning is especially challenging. We present two multiagent distributed control strategies that are highly efficient and computationally inexpensive for determining collision-free paths for RFPs in heavily overlapping workspaces. We demonstrate that a reconfiguration path between two arbitrary robot configurations can be efficiently found if a “folded” state, in which all robot arms are retracted and aligned in a lattice-like orientation, is inserted between the initial and final states. Although developed for SDSS-V, the approach we describe is generic and thus applicable to a wide range of RFP designs and layouts. Robotic fiber positioner technology continues to advance rapidly, and in the near future ultra-densely packed RFP designs may be feasible. Our algorithms are especially capable in routing paths in very crowded environments, where we see efficient results even in regimes significantly more crowded than the SDSS-V RFP design.

42 ENGINEERING↗

SOLARIS 3-axis high load, low profile, high precision motorized positioner

A 3-axis optical table, shown in Figure 1, was designed, fabricated, and assembled for the SOLARIS synchrotron facility at the Jagiellonian University in Krakow, Poland. To accommodate the facility, the table was designed to be very low profile, as seen in Figure 2, and bear a high load. The platform has degrees of freedom in the vertical (Z) direction as well as horizontal transversal (X and Y) directions. The table is intended to sustain loads as large as 1500 kg which will be sufficient to support a variety of equipment to measure and facilitate synchrotron radiation. After assembly, the table was tested and calibrated to find its position error in the vertical direction. ADC has extensive experience designing and building custom complex high precision motion systems [1,2].

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fabrication of Six Degrees-of-Freedom Hexflex Positioner With Integrated Strain Sensing Using Nonlithographically Based Microfabrication

In this study, a process flow is described for the low cost, flexible fabrication of metal micro-electromechanical systems (MEMS) with high performance integrated sensing. The process is capable of producing new designs in ≈1 week at an average unit cost of <$1 k/device even at batch sizes of ≈1–10, with expected sensing performance limits of about 135 dB over a 10 kHz sensor bandwidth. This is a ≈20× reduction in cost, ≈25× reduction in time, and potentially >30× increase in sensing dynamic range over comparable state-of-the-art compliant nanopositioners. The nonlithographically based microfabrication (NLBM) process is uniquely suited to create high performance nanopositioning architectures which are customizable to the positioning requirements of a range of nanoscale applications. These can significantly reduce the cost of nanomanufacturing research and development, as well as accelerate the development of new processes and the testing of fabrication process chains without excess capital investment. A six degrees-of-freedom (6DOF) flexural nanopositioner with integrated sensing for all 6DOF was fabricated using the newly developed process chain. The fabrication process was measured to have ≈30 μ m alignment. Sensor arm, flexure, and trace widths of 150 μ m, 150 μ m, and 800 μ m, respectively, were demonstrated. Process capabilities suggest lower bounds of 25 μ m, 50 μ m, and 100 μ m, respectively. Dynamic range sensing of 52 dB was demonstrated for the nanopositioner over a 10 kHz sensor bandwidth. Improvements are proposed to approach sensor performance of about 135 dB over a 10 kHz sensor bandwidth.

42 ENGINEERING↗

Characterizing Al quasiparticle diffusion using a positionable laser (Final Technical Report)

This Career Award accomplished most of its goals, in demonstrating for the first time a low- threshold nuclear recoil detector based on the quantum evaporation of helium-4. Through this work, we trained several PhD students and evolved this niche R&D topic into a central pillar of the DOE-funded TESSERACT project, which now plans to take underground helium data in 2028.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The DESI Fiber View Camera System

The Dark Energy Spectroscopic Instrument (DESI) is a 5000 fiber multi-object spectrometer now being installed at the prime focus of the 4 m Mayall telescope at Kitt Peak. Using DESI to measure ~35 million galaxy redshifts and using the Baryon Acoustic Oscillation (BAO) technique to measure distances, the results will probe the nature of the recently discovered mysterious component of our universe called dark energy. Computer controlled robotic positioners move the 120 μm diameter fibers to positions of galaxies whose location on the sky have been obtained in a previous target selection imaging survey. To achieve good throughput the fibers should be centered on the target position to within 3 μm. The robotic positioners however are only capable of a 50 μm precision on their first move. To achieve the desired precision, the Fiber View Camera (FVC) system has been implemented. The FVC, located near the hole in the primary mirror of the Mayall telescope, has been designed to take an exposure of the focal plane, located at the prime focus some 12 m above the FVC, after the robotic positioners have completed their first move. The FVC is intended to measure the fiber locations with a precision of 3 μm and issue a set of fiber coordinate corrections for the second move correcting the fiber positions by the robotic positioners. Tests show that after two iterations better than 99% of the fibers will be in their intended location to within the desired precision. This paper describes the design of the FVC system, the R&D program preceding the final design, and the tests that have been carried out to demonstrate that the FVC can achieve the required precision.

(cosmology:) dark energy↗

Installation of the Dark Energy Spectroscopic Instrument at the Mayall 4-meter telescope

The Dark Energy Spectroscopic Instrument (DESI) is a Stage IV ground-based dark energy experiment that will measure the expansion history of the Universe using the Baryon Acoustic Oscillation technique. The spectra of 35 million galaxies and quasars over 14000 square degrees will be measured during the life of the experiment. We describe the installation of the major elements of the instrument at the Mayall 4m telescope, completed in late 2019. The previous prime focus corrector, spider vanes, and upper rings were removed from the Mayall’s Serrurier truss and replaced with the newlyconstructed DESI ring, vanes, cage, hexapod, and optical corrector. The new corrector was optically aligned with the primary mirror using a laser tracker system. The DESI focal plane system was integrated to the corrector, with each of its ten 500-fiber-positioner petal segments installed using custom installation hardware and the laser tracker. Ten DESI spectrographs with 30 cryostats were installed in a newly assembled clean room in the Large Coude Room. The ten cables carrying 5000 optical fibers from the positioners in the focal plane were routed down the telescope through cable wraps at the declination and hour angle axes, and their integral slitheads were integrated with the ten spectrographs. The fiber view camera assembly was installed to the Mayall’s primary mirror cell. Servers for the instrument control system replaced existing computer equipment. The fully integrated instrument has been commissioned and is ready to start its operations phase.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A DESI ‘Petal’ in Bloom: Time-Lapse Video

This time-lapse video sequence shows how how components are assembled for a single wedge-shaped petal that is part of the Dark Energy Spectroscopic Instrument’s focal plane. This video condenses the work on this petal – which took several weeks – down to about 5 minutes. In all, the focal plane will be composed of 10 petals, each holding 500 robotic positioners. Each of these positioners carries a fiber-optic cable, and the cables will be individually pointed at preset sequences of distant galaxies to gather their light. The light signatures from these galaxies will form the basis for the largest 3-D map of the universe. Each positioner is outfitted with a 3-meter length of fiber-optic cable that will be precisely fused with a 50-meter cable. The focal plane will sit high atop the Mayall Telescope at Kitt Peak National Observatory near Tucson, Arizona. (Credit: Berkeley Lab)

47 OTHER INSTRUMENTATION↗

ProtoDESI: First On-Sky Technology Demonstration for the Dark Energy Spectroscopic Instrument

The Dark Energy Spectroscopic Instrument (DESI) is under construction to measure the expansion history of the universe using the baryon acoustic oscillations technique. The spectra of 35 million galaxies and quasars over 14,000 square degrees will be measured during a 5-year survey. A new prime focus corrector for the Mayall telescope at Kitt Peak National Observatory will deliver light to 5,000 individually targeted fiber-fed robotic positioners. The fibers in turn feed ten broadband multi-object spectrographs. We describe the ProtoDESI experiment, that was installed and commissioned on the 4-m Mayall telescope from 2016 August 14 to September 30. ProtoDESI was an on-sky technology demonstration with the goal to reduce technical risks associated with aligning optical fibers with targets using robotic fiber positioners and maintaining the stability required to operate DESI. The ProtoDESI prime focus instrument, consisting of three fiber positioners, illuminated fiducials, and a guide camera, was installed behind the existing Mosaic corrector on the Mayall telescope. A fiber view camera was mounted in the Cassegrain cage of the telescope and provided feedback metrology for positioning the fibers. ProtoDESI also provided a platform for early integration of hardware with the DESI Instrument Control System that controls the subsystems, provides communication with the Telescope Control System, and collects instrument telemetry data. In conclusion, lacking a spectrograph, ProtoDESI monitored the output of the fibers using a fiber photometry camera mounted on the prime focus instrument. ProtoDESI was successful in acquiring targets with the robotically positioned fibers and demonstrated that the DESI guiding requirements can be met.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-505: A Novel Approach for Sparing Critical Organs at Risk for Cancer Patients Undergoing Radiation Oncology Treatments

Purpose: A major goal of an effective radiation treatment plan is to deliver the maximum dose to the tumor while minimizing radiation exposure to the surrounding normal structures. For example, due to the radiation exposure to neighboring critical structures during prostate cancer treatment, a significant increase in cancer risk was observed for the bladder (77%) and the rectum (105%) over the following decade. Consequently, an effective treatment plan necessitates limiting the exposure to such organs which can best be achieved by physically displacing the organ at-risk. The goal of this study is to present a prototype for an organ re-positioner device designed and fabricated to physically move the rectum away from the path of radiation beam during external beam and brachytherapy treatments. This device affords patient comfort and provides a fully controlled motion to safely relocate the rectum during treatment. Methods: The NiTi shape memory alloy was designed and optimized for manufacturing a rectal re-positioner device through cooling and heating the core alloy for its shaping. This has been achieved through a prototyped custom designed electronic circuit in order to induce the reversible austenitic transformation and was tested rigorously to ensure the integrity of the actuated motion in displacement of the target anatomy. Results: The desirable NiTi shape-setting was configured for easy insertion and based on anatomical constraint. When the final prototype was evaluated, accuracy and precision of the maximum displacement and temperature changes revealed that the device could safely be used within the target anatomy. Conclusion: The organ re-positioner device is a promising tool that can be implemented in clinical setting. It provides a controlled and safe displacement of the delicate organ(s) at risk. The location of the organ being treated could also be identified using conventional onboard imaging devices or MV imaging available on-board most modern clinical accelerators.

60 APPLIED LIFE SCIENCES↗

Chamber Interior Viewing System (CIVS 2.0)

The NIF facility is used to conduct fusion and high-density scientific research. The experiments are conducted inside of a 10-meter diameter vacuum chamber called the “Target Chamber”. The target chamber is covered in ports to permit adding equipment to the exterior. Some of this equipment extends into the target chamber such as the target positioners and diagnostics. Other equipment sits on the surface and looks inward, such as the CIVS system. CIVS stands for Chamber Interior Viewing System. The CIVS system provides simple black and white digital images of the interior of the target chamber in real time. These images are used for positioner alignment, trouble shooting and observing for positioner collision. The views through these cameras need to be clear enough for the operators to safely conduct these tasks. One of the products of the experiments conducted in the target chamber are neutrons. These neutrons expand outward from the center of the target chamber with great energy. If the neutrons hit the sensor chip on a digital camera they will “kill” the sensor pixel where they contact, and the result will be a permanently bright white pixel on the image. Over time these “dead” pixels will build up and make the camera less and less usable providing a “staticky” image. The current solution of replacing the cameras when they become damaged is unsustainable due to both the cameras being out of production and the increased rate of camera failure based upon the increased number and energy of neutrons being generated. Current supplies of the correct camera type are dwindling with no source of replacement and the projected rate of replacement is unsustainable. Without a redesign, the function provided by the current CIVS system will be lost.

42 ENGINEERING↗