Parametric Testing and Evaluation of a Novel Biphasic Absorption Process for Post-Combustion Carbon Capture

A novel biphasic CO2 absorption process (BiCAP) is being developed at the University of Illinois. BiCAP is enabled by using a new class of biphasic solvents developed based on multi-property criteria for postcombustion carbon capture. The process was previously demonstrated at the lab-scale, including in 10 kWe absorption and desorption column systems. In the current study, the process has been scaled up by building and testing a 40 kWe integrated capture skid at a power plant. Parametric tests for two biphasic solvents were conducted with the synthetic flue gas made of bottle CO2 gas and air to validate the performance and operational flexibility of the unit with respect to varying process or operating conditions. Operation of the phase separator, which is unique equipment to BiCAP, was verified to be stable and efficient. Two liquid phases could be separated via static settlement based on a density difference and >90% of the CO2 absorbed was concentrated in the separated CO2-rich phase. Results of parametric tests showed that the minimum heat duty appeared at the optimal stripping pressure. A higher stripping temperature was more favourable to improve overall energy performance. Introducing a secondary cold solvent feed stream to the top of the stripper via bypassing the cross heat exchanger helped reduce the heat loss carried with water vapour. Test results also revealed that the heat duty requirement was comparable when the CO2 concentration in flue gas decreased from ~11 to 4 vol.% as the phase separation decoupled the absorption and desorption steps in BiCAP. Under typical steady-state conditions, both biphasic solvents lowered the process heat duty by >40% compared with the reference 30 wt.% monoethanolamine solvent.

Absorption↗

Development and Bench-Scale Testing of a Novel Biphasic Solvent-Enabled Absorption Process for Post-Combustion Carbon Capture (Final Technical Report)

A new class of biphasic solvents was developed, and the concept of the enabled carbon dioxide (CO 2 ) absorption process was tested for post-combustion carbon capture in our previous lab-scale research. The primary goals of this project were to advance the development of the novel biphasic CO 2 absorption process (BiCAP) and validate its technical advantages by testing the integrated technology at a 40 kWe bench-scale with actual coal-derived flue gas in a power plant environment. The project was led by the University of Illinois at Urban-Champaign (UIUC), and Trimeric Corporation served as a sub-awardee providing support in basic design and techno-economic studies. To achieve the project goals and objectives, solvent management studies, process modeling and optimization, bench-scale equipment design, construction and testing, and technical, economic and environmental assessments have been conducted. The two top-performing biphasic solvents developed in our previous research were used in this project. Biphasic solvent emissions and control were investigated in the laboratory. The emissions of the biphasic solvents from the absorber were comparable to or lower than the reference 30 wt% monoethanolamine (MEA) solution, while they could be more effectively removed in the water wash column. Lab-scale testing of solvent degradation reclamation has revealed that vacuum distillation was feasible for biphasic solvent reclamation. Aspen Plus models were used to optimize the BiCAP, and a CO 2 stripping configuration introducing a secondary cold solvent feed to the stripper was identified to be the most energy efficient. A 40 kWe bench-scale, integrated BiCAP system was successfully designed, fabricated, and installed at the UIUC’s Abbott Power Plant. Parametric testing with synthetic flue gas has demonstrated that the two biphasic solvents required a more than 40% lower heat duty for CO 2 desorption as compared to the reference MEA tested on the same bench-scale skid. Slipstream testing with actual coal flue gas for a total of 31 days in two test campaigns has further demonstrated stable operation of the bench-scale skid. During the first campaign targeting 90% CO 2 removal, the heat duty averaged at 2,183 MJ/tonne of CO 2 captured and during the second campaign targeting 95% removal, the heat duty averaged at 2,450 MJ/tonne of CO 2 captured. A techno-economic analysis has revealed that for integration of the BiCAP into a 650-MWe pulverized coal-fired power plant, the parasitic power loss was reduced by ~20%, and the cost of CO 2 capture was reduced by ~21% ($36.3/tonne on a December 2018 dollar basis) compared to the U.S. Department of Energy (DOE)’s baseline Case B12B. As progression from this bench-scale development effort, a new project “Engineering-Scale Testing of the Biphasic Solvent Based CO 2 Absorption Capture Technology at a Covanta Waste-to-Energy Facility” was awarded by the DOE, launched in February 2023, to allow the team to further test the technology and demonstrate its technical and economic advantages at a pilot scale.

20 FOSSIL-FUELED POWER PLANTS↗

Computational Analysis of the Effect of Structured Packing Design on Absorption Column Hydrodynamics for Post-Combustion Carbon Capture Applications

Solvent based post-combustion carbon capture technologies have a potential for reducing carbon emissions from fossil-fuel-fired power plants and industrial sources where CO2 emissions are inherently harder to mitigate, such as steel or cement industries. A prominent technology to achieve this is by retrofitting absorption columns to the existing infrastructure. While these systems have been among the less costly alternatives for carbon capture, they still impose a considerable energy penalty to the operation of power plants or industrial facilities. The optimization of CO2 capture rate in solvent-based absorption process is complex as it depends on several factors including CO2 solubility, solvent reaction kinetics and temperature effects on the solubility, reaction rates, surface tension, and thermophysical properties of the solvent and the flue gas. The overall heat and mass transfer also depends on the hydrodynamics, which in turn, is affected by the packing geometry. In the current work, we systematically quantify the effects the design of the structured packing has on the column hydrodynamics, by performing detailed CFD simulations for different geometrical configurations and operating conditions. We then obtain relationships between the key hydrodynamic metrics, such as liquid holdup, interfacial area, wetted area, and pressure drop to the parameters defining the packing geometries and identify new more effective packing designs for the given operating conditions.

Shah, Yash Girish↗

Comparative study of machine learning techniques for post-combustion carbon capture systems

Computational analysis of countercurrent flows in packed absorption columns, often used in solvent-based post-combustion carbon capture systems (CCSs), is challenging. Typically, computational fluid dynamics (CFD) approaches are used to simulate the interactions between a solvent, gas, and column's packing geometry while accounting for the thermodynamics, kinetics, heat, and mass transfer effects of the absorption process. These simulations can then be used explain a column's hydrodynamic characteristics and evaluate its CO 2 -capture efficiency. However, these approaches are computationally expensive, making it difficult to evaluate numerous designs and operating conditions to improve efficiency at industrial scales. In this work, we comprehensively explore the application of statistical ML methods, convolutional neural networks (CNNs), and graph neural networks (GNNs) to aid and accelerate the scale-up and design optimization of solvent-based post-combustion CCSs. We apply these methods to CFD datasets of countercurrent flows in absorption columns with structured packings characterized by several geometric parameters. We train models to use these parameters, inlet velocity conditions, and other model-specific representations of the column to estimate key determinants of CO 2 -capture efficiency without having to simulate additional CFD datasets. We also evaluate the impact of different input types on the accuracy and generalizability of each model. We discuss the strengths and limitations of each approach to further elucidate the role of CNNs, GNNs, and other machine learning approaches for CO 2 -capture property prediction and design optimization.

97 MATHEMATICS AND COMPUTING↗

Energy-efficient carbon capture from industrial point sources via commercially available green solvent and hollow fiber membrane contactors

Solvent-based absorption systems have emerged in the carbon capture space due to their high absorption capacities, reusability, and favorable energy requirements. Using diethyl sebacate as a solvent for pre- and post-combustion carbon capture has advantages over other solvents, including high hydrophobicity, low viscosity, low vapor pressure, high CO 2 solubility, high CO 2 selectivity, and being commercially available in large quantities. Despite these advantageous properties, the use of diethyl sebacate as a solvent for post-combustion carbon capture has not been studied in detail. To examine the capability of diethyl sebacate, a scalable, energy-efficient, hollow fiber membrane (microporous polypropylene and polyvinylidene fluoride) contactor (HFMC)-based process with low-cost and high surface area is investigated. A purity of 95.3 % CO 2 with 46 % recovery in one absorption stage was achieved, with a permeate flux over one magnitude greater than using a deep eutectic solvent in the same system. Technoeconomic analysis determined a ∼ 0.8 GJ per ton of CO 2 at a processing cost of ∼$93 per ton of CO 2 . Results from this work underscore the potential for utilizing green solvents in HFMC-based separation processes for effective carbon capture and provide a pathway towards practical deployment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Validation Framework for Post-Combustion Carbon Capture CFD Simulations

First-principles based computational fluid dynamics (CFD) simulations are proposed as a fundamental tool for investigating solvent-based CO2 absorption in packed columns, due to the ability to accurately represent the underlying non-linear multiscale dynamics. In this work, we employ such models to investigate hydrodynamics of columns with structured by assessing the key hydrodynamic metrics, such as pressure drop and liquid holdup. Our models are validated with experimental data from a specifically designed column for this line of work. The test cases of gas and liquid flowrates and operating conditions were selected through a comprehensive sequential design of experiments approach offered by the CCSI2 toolset.

Panagakos, Grigorios↗

Engineering-Scale Test of a Water-Lean Solvent for Post-Combustion Capture

EPRI, Pacific Northwest National Laboratory, RTI International, and their project collaborators developed an engineering-scale test of a new water-lean solvent, N-(2-ethoxyethyl)-3-morpholinopropan-1-amine (EEMPA or 2-EEMPA) as a post-combustion CO 2 capture solvent for power plant applications. This test was conducted using the Pilot Solvent Test Unit at the National Carbon Capture Center. The primary objective of this test was to collect long-term data operating EEMPA with both coal- and natural gas-representative flue gases at the approximately 0.5 MW e -equivalent scale (5–10 metric tons CO 2 /day captured). This report details the activities preparing for that test, data collected during the test campaign, and analyses and interpretations of that data.

20 FOSSIL-FUELED POWER PLANTS↗

Oxygen Solubility in Aqueous Amine Solvents with Common Additives Used for CO 2 Chemical Absorption

Major sources of anthropogenic CO 2 are power generation and transportation industries where researcher continue to explore CO 2 emission mitigation strategies as applied to these CO 2 sources through carbon capture, utilization, and sequestration (CCUS). The most mature CO 2 capture technology is post-combustion carbon capture (PCCC) using aqueous amine solutions/solvents, however solvent degradation and regeneration costs are slowing the widespread adoption of PCCC. Solvent degradation of the aqueous amine solutions is mainly caused from the temperature gradient between the absorber and stripper columns and common flue gas components such as SOx, NOx, and oxygen (O 2 ). The two main classifications of solvent degradation are thermal degradation, occurring when the amine reacts with itself at elevated temperatures and anaerobic conditions and oxidative degradation. Oxidative degradation reactions can occur from oxygen mass transfer and free radical oxidation. Metals, such as iron from the corrosion of steel structures used in industrial applications such as PCCC, can help to catalyze these reactions. Various oxidative degradation studies have shown how O 2 concentrations in flue gas and, to a lesser extent, temperature influence the extent of oxidative degradation. Accurately measuring the O 2 solubility, commonly referred to as dissolved oxygen (DO), in a quick, continuous, and efficient manner in aqueous amine solvents should contribute to determine the effectiveness of mitigation strategies for oxidative degradation. Knowing that commercial PCCC amine solvents contain components beyond water, amine, carbonate species and CO 2 , this investigation was conducted to determine the oxygen solubility changes of common aqueous amines solutions with commonly used and published solvent additives. The impact of carbon loadings with and without the additives was also examined. A commercial dissolved oxygen probe was used to measure the DO concentrations and compared them against standard Winkler Method titration values. The results show that antifoam shows minimal change in [DO]. MBT yielded lower DO values, and NaVO 3 showed a higher DO concentration due to interferences. These results indicate that most common amine solvent additives should be expected to minimally impact oxygen solubility and amine oxidative degradation.

60 APPLIED LIFE SCIENCES↗

Mass transfer intensification through increased surface wetting and liquid turbulence using 3D printing structured packing for CO2 capture

The absorber column is one of the most expensive pieces of equipment to construct in the solvent-based post-combustion carbon capture unit. In order to decrease the absorber size and reduce capital costs, novel polymer packings were proposed by enhancing surface wettability and local turbulence within liquid solvent. The novel packings intensify the mass transfer in CO2 absorption and show better separation efficiency than traditional structured packings. In this work, the economic influence of applying the more efficient packing with a shorter absorber column is studied in a techno-economic analysis for a carbon capture unit at a coal-fired power plant. The baseline case includes CO2 capture unit in a supercritical pulverized coal power plant to generate 650 MWe (net) of electricity, where the additional CO2 capture unit leads to 63.4% increase of LCOE. While implementing UK PCC with traditional and novel packings, there will be 47.2% and 46.4% LCOE increase separately, both of which are lower than the baseline value. Applying more efficient packing and smaller absorber could further lessen the LCOE increase. The UK PCC with traditional packings reduces CO2 capture cost by 23.4% and the application of the advanced packings allows to the reduction increases to 24.4%.

60 APPLIED LIFE SCIENCES↗

TEA of a Unique Two-Pathways Process for Post-Combustion CO 2 Capture

A unique two-Pathways process using aqueous sodium glycinate for CO 2 capture from a split flue gas stream emitted from 600 MWe post-combustion coal power plant was developed in Aspen Plus v.10. The split gas flow rate used was 44.75 ton/h and contained 0.0023 mol% SO 2 and 13.33 mol% CO 2 . The process includes a washing unit, a CO 2 absorption unit, a reverse osmosis unit, and a solvent regeneration unit or an ultrafiltration unit. The washing unit uses deionized water to completely remove SO 2 and the CO 2 absorption unit uses SGS to capture at least 90 mol% of the CO 2 in the split flue gas stream. Upon CO 2 and SGS reactions, the resulting liquid products exhibit phase-separation into CO 2 -lean phase and CO 2 -rich phase, allow two distinct pathways. Pathway (i) is to regenerate mostly the CO 2 -rich phase, collect the released CO 2 , and compress it for sequestration purposes. Pathway (ii) is to send the liquid stream from the CO 2 absorption unit to the ultrafiltration unit to separate the solid nanomaterials. The hydraulics and mass transfer characteristics in the washing and CO 2 absorption units were obtained; and techno-economic analysis (TEA) for Pathways (i) and (ii), including Capital Expenditure (CAPEX), Operating Expenditure (OPEX), and Levelized Cost of CO 2 Captured (LCOC), were calculated and compared. The simulation results revealed that the CAPEX, OPEX, and LCOC for Pathway (i) were ($\$12,039,251$), (261 dollar/h), and (54.01 dollar/ton-CO 2 captured), respectively, and those for Pathway (ii) were ($\$5,908,000$), (237.2 dollar/h), and (39.90 dollar/ton-CO 2 captured), respectively. Moreover, in Pathway (ii), 8.19 ton/h of CO 2 were captured to produce 15.62 ton/h NaHCO 3 nanomaterials, which were sold to offset the overall process cost. The LCOC values indicate that Pathway (ii) is more cost-effective than Pathway (i) because LCOC values for Pathway (ii) are much lower than those for Pathway (i).COC values for Pathway (ii) are much lower than those for Pathway (i).

20 FOSSIL-FUELED POWER PLANTS↗

Modular Adaptive Packing for Integrally Cooled Absorbers

Process intensification is one cornerstone in ION Clean Energy’s (ION) efforts to lowering CO2 capture cost. ION has modeled, designed, and fabricated an innovative gas-liquid contactor known as Modular Adaptive Packing (MAP). During two successful SBIR Phase I and II projects entitled: “Rapid Design and Testing of Novel Gas-Liquid Contacting Devices for Post-Combustion CO2 Capture via 3D-printing”, ION developed and proved this new technology at bench scale. MAP, a 3D-printed lattice-structured packing, combines the absorber gas/liquid contactor with an innovative in-situ heat-exchanger. Thanks to the capabilities of 3D-printing, the lattice structure of MAP contains hollow channels through which coolant water can be pumped to remove the heat of reaction from CO2 absorption. ION refers to this novel method of heat exchange as intracooling. After 25.4 cm (10 in) diameter MAP modules were fabricated, ION built and tested a packing characterization rig at its pilot facility in Boulder, Colorado, U.S.A. To provide baseline results for the characterization rig, ION tested Sulzer’s Mellapak™ 250Y (MP250Y) as a standard structured packing. ION’s MAP was then compared directly to the baseline MP250Y packing to evaluate key indicators including pressure drop, liquid hold-up, and effective area. MAP has a higher pressure drop than MP250Y at the same gas velocities in addition to greater liquid holdup. However, ION found that MAP displays a higher wetting coverage of 93% compared to 65% for MP250Y and reduces shearing forces that result in undesirable droplet formation. Using Optimized Gas Treating’s (OGT) rate-based simulation software ProTreat®, a conceptual evaluation of MAP was modeled for a CO2 absorber using 30 wt% MEA solvent over a range of lean loadings at 90% CO2 capture from a coal-fired power plant. ION modeled a 25-meter column absorber for both the standard MP250Y packing and a hybrid column. The hybrid absorber contained 10 m of MP250Y packing at the top and bottom with the middle 5 meters comprised of MAP. Compared to a traditional intercooled absorber, MAP can remove 22% more heat and increase overall MEA carrying capacity by 4% without increasing overall pressure drop.

20 FOSSIL-FUELED POWER PLANTS↗

Purification of Degraded Aqueous Piperazine by Ion Exchange and Carbon Treating

Amine purification by ion exchange and carbon treating has been performed for decades to maintain low solvent impurity levels in amines used in natural gas sweetening. The use of these purification methods to remove dissolved metal catalysts and other impurities from amines used in post-combustion carbon capture is less well known. This report presents batch experiments testing the equilibrium adsorption of impurities from degraded piperazine (PZ) onto activated carbon and various ion exchange resins. Compared to cationic exchange, anionic exchange was found to better remove catalytic Fe and UV active species, making it a better candidate for large-scale PZ purification. Carbon treating greatly outperforms anion exchange in the removal of UV active species, but the adsorbents’ difference is less pronounced for the removal of other impurities. Equilibrium adsorption was determined by the UV absorption of the PZ solution at 320 nm, and the results will show this may not be an accurate way to determine equilibrium. Further bench-scale experiments comparing ion exchange and carbon treating are necessary before advancing to larger-scale testing.

amine purification↗

Beta-Amino Carboxylate (BAC) non-aqueous physical solvents for enhanced CO2 separations in pre-combustion carbon capture, industrial CO 2 capture, and biogas upgrading processes

Novel beta-amino carboxylate (BAC) solvents have been synthesized and tested to efficiently capture carbon dioxide (CO 2 ) from process gas streams with CO 2 partial pressure intermediate between pre-combustion and post-combustion capture. The BAC solvents have molecular structures characterized by alkyl-substituted amides or esters containing a secondary amine functional group on the second carbon from the carbonyl carbon (referred to as the beta “β” carbon). The ester or amide functional group combined with optimal steric crowding around the amine nitrogen by proximate alkyl groups are tailored to modify the strength of CO 2 binding in the solvent. The solvents possess high CO 2 solubilities and high gas selectivity including good CO 2 /H 2 O selectivity and can be utilized for CO 2 absorption over a range of partial pressures. Due to low volatility, many of the solvents can be operated at or above ambient temperature which eliminates solvent chilling and allows regeneration using low grade waste heat. These novel solvents offer an opportunity for efficient carbon capture for a range of applications including biogas upgrading, hydrogen production, and pre-combustion carbon capture.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Biphasic solvents for post-combustion CO 2 capture from natural gas flue Gas

Fossil fuel fired power plants are generally expected to remain one of the most significant global sources of electricity for decades to come. Consequently, carbon management technologies are needed to reduce or eliminate ongoing emissions from these sources. Amongst the many techniques for carbon capture, aqueous amine-based absorbents (monoethanolamine, MEA, in particular) are, presently, considered the leading technology for post-combustion CO 2 point-source capture. These technologies are nevertheless limited by their high capital and regeneration energy costs. Biphasic solvents have been identified as an attractive alternative to traditional MEA based absorbents due to their potential energy savings. Thus far, however, the research on biphasic solvents has largely focused on their performance in coal flue gas while more dilute natural gas flue gas applications have received relatively little attention. Here, this work examines the performances of two novel biphasic solvent blends, diethylenetriamine (DETA) and triethylenetetramine (TETA), in CO 2 capture from a natural gas flue gas simulant. Across several regeneration tests, both solvents achieved considerable energy savings over the benchmark MEA solution. Specifically, the energy consumption per mol CO 2 recovered for the DETA-based and TETA-based solvents was 46 % and 35 % less than that of the benchmark MEA solution, respectively. Molecular dynamics simulations were also performed to gain a deeper understanding of the phase separation phenomena that occur as a consequence of CO 2 absorption. These simulations indicated that phase change was driven by the strong interaction between the absorption products and water, while the degree of separation depended on the CO 2 loading.

Biphasic solvents↗

Compact Absorber Technology Leads to Significant Reduction in the Cost of Point Source CO 2 Capture

The size of columns in traditional absorption-based processes for CO 2 capture contributes significantly to the overall capital cost. A demonstrated method to reduce the cost of point source CO 2 capture, focusing on reducing the absorber height by increasing the liquid-to-gas reaction contact area and decreasing the CO 2 diffusion resistance without increasing gas-side pressure drop is presented along with techno-economic analysis results. Bench-scale tests on the unique Compact Absorber showed overall CO 2 mass transfer enhancement of varying degrees compared to a traditional packed column for similar process conditions, demonstrating that a 60+% reduction in size of a typical post-combustion absorber with a packing height of 70-100 ft and total height of 150-180 ft can be achieved. The techno-economic analysis showed significant cost reductions when the Compact Absorber is combined with other transformative aspects of the University of Kentucky Institute for Decarbonization and Energy Advancement point source CO 2 capture process compared to the U.S. Department of Energy National Energy Technology Laboratory pertinent reference case for pulverized coal plants with CO 2 capture. Here, a levelized cost of electricity excluding CO 2 transportation and storage of $\$95.6$/MWh was estimated, which is a 9% reduction, with a total capital cost contribution of $45/MWh, which is a 12% reduction. Additionally, a breakeven CO 2 sales price also referred to as the cost of CO 2 capture, of $36.70/tonne was estimated when the UK hindered primary amine solvent is used, which is a 20% reduction compared to the reference case.