Search NASA⌕ Search

SEARCH · Search NASA

Results for “power balancing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Intercell Power Transformer for Power Balancing of Polyphase Wireless Power Transfer Systems

Polyphase wireless power transfer (PWPT) systems experience receiver side imbalances in misaligned conditions. This paper proposes a method for power balancing in PWPT systems, specifically addressing the challenges caused by receivers coil unequal coupling. An intercell power transformer (IPT) is introduced at the receiver side to mitigate the effects of coil mismatch. Simulations of the PWPT system incorporating IPT demonstrate its effectiveness in enhancing power distribution. For voltage-fed rectifiers (VFR), the IPT increases the conduction angle, resulting in higher output power. In current- fed rectifiers (CFR), the IPT promotes uniform power sharing among rectifiers, thereby reducing electrical stress on semiconductor devices and passive components. Simulation results indicate that, under coil misalignment, the IPT improves output power by approximately 49% for VFRs and 44% for CFRs compared to conventional PWPT systems without IPT.

Wojda, Rafal [ORNL] (ORCID:0000000286609268)↗

The constraint of plasma power balance on runaway avoidance

Abstract In a post-thermal-quench plasma, mitigated or unmitigated, the plasma power balance is mostly between collisional or Ohmic heating and plasma radiative cooling. In a plasma of atomic mixture { n α } with α labeling the atomic species, the power balance sets the plasma temperature, ion charge state distribution { n α i } with i the charge number, and through the electron temperature T e and ion charge state distribution { n α i } , the parallel electric field E ∥ . Since the threshold electric field for runaway avalanche growth E a v is also set by the atomic mixture, ion charge state distribution and its derived quantity, the electron density n e , the plasma power balance between Ohmic heating and radiative cooling imposes a stringent constraint on the plasma regime for avoiding and minimizing runaways when a fusion-grade tokamak plasma is rapidly terminated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamics and Power Balance of Near Unity Target Gain Inertial Confinement Fusion Implosions

The change in the power balance, temporal dynamics, emission weighted size, temperature, mass, and areal density of inertially confined fusion plasmas have been quantified for experiments that reach target gains up to 0.72. It is observed that as the target gain rises, increased rates of self-heating initially overcome expansion power losses. This leads to reacting plasmas that reach peak fusion production at later times with increased size, temperature, mass and with lower emission weighted areal densities. Analytic models are consistent with the observations and inferences for how these quantities evolve as the rate of fusion self-heating, fusion yield, and target gain increase. At peak fusion production, it is found that as temperatures and target gains rise, the expansion power loss increases to a near constant ratio of the fusion self-heating power. Finally, this is consistent with models that indicate that the expansion losses dominate the dynamics in this regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Power balance analysis at the L-H transition in JET-ILW NBI-heated deuterium plasmas

The understanding of the physics underlying the L-H transition has strong implications for ITER experimental reactor and demonstration power plant (DEMO). In many tokamaks, including JET, it has been observed that, at a particular plasma density, n e,min , the power necessary to access H-mode P L-H is minimum. In the present work, L-H transitions of JET deuterium plasmas heated by neutral beam injection (NBI) are studied for the first time by means of a power balance analysis to characterize the main contributions in the transition, through integrated transport modelling. In the pulses analysed, we do observe a minimum of the L-H power threshold in density, indicating the presence of density branches and of n e,min . Electron and ion heat fluxes at the transition are estimated separately. The electron/ion equipartition power results in favour of the ions, as shown by QuaLiKiz quasilinear gyrokinetic simulations, which predict a larger ion transport that causes T e > T i . The resulting edge ion heat flux also shows a clear change of slope below n e,min , similarly to ASDEX-Upgrade (AUG) NBI pulses (Ryter et al 2014 Nucl. Fusion 54 083003). JET NBI data are compared to radio-frequency heated AUG and Alcator C-mod pulses (Schmidtmayr et al 2018 Nucl. Fusion 58 056003), showing a different trend of the power, coupled to ions at the L-H transition with respect to the linearity observed in the radio-frequency heated plasmas. Finally, the presence of n e,min and the role of the ion heat flux is discussed in the paper, although it seems it is not possible to explain the presence of a P L-H minimum in density by a critical ion heat flux and by the equipartition power for the JET NBI-heated plasmas analysed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Power balance and divertor asymmetries in the Super-X divertors of MAST-U using SOLPS-ITER

Spherical tokamaks (STs) present unique challenges and opportunities in the area of particle and power exhaust, intensified due to their more compact sizes. Substantial efforts are underway in STs to determine the limits in dissipative operational regimes and advanced divertor solutions, including at MAST-U which provides access to the Super-X divertor configuration. Power balance, and upper/lower divertor asymmetries have been studied using SOLPS-ITER simulations of the MAST-U Super-X divertor. A set of simulations with experimentally inferred transport coefficients with E x B and diamagnetic drifts activated, consisting of density and power scans, and high field side vs low field side gas puff locations, have been used for code experimentation to uncover trends beyond the current experimental parameter space. The upper biased asymmetry (U:L > 1) of the ratio of the peaks of the plasma energy flux densities at the outer targets increases with heating power and decreases with gas puff strength, going from symmetric to up to a factor of 15. The upper target electron temperature has been found to be a good ordering quantity for the magnitude of this asymmetry for all heating powers, gas puff strength, and gas puff locations. The lower divertor biased asymmetry (U:L < 1) of the radiation patterns processed through SOLPS-based bolometry synthetic diagnostics is in qualitative agreement with resistive bolometry experimental results, and it is in quantitative agreement with the trend of the total volume radiation within the divertors of SOLPS. However, radiation measurements alone are not sufficient to infer the magnitude of the asymmetry of the peaks of the power loads at the targets.

MAST-U↗

Assessing the Accuracy of Balanced Power System Models in the Presence of Voltage Unbalance

Traditional models of electric power systems represent distribution systems with unbalanced three-phase network models and transmission systems with balanced single-phase-equivalent network models. This distinction poses a challenge for coupled models of transmission and distribution systems, which are becoming more prevalent due to the growth of distributed energy resources connected to distribution systems. In order to maintain a balanced network representation, transmission system models typically assume that the voltage phasors at the interface to the distribution system are balanced. Inaccuracies resulting from this assumption during unbalanced operation can lead to erroneous values for line currents in the transmission system model. This paper empirically quantifies the accuracy of this balanced operating assumption during unbalanced operating conditions for both a simple two-bus system along with a more complex transmission and distribution co-simulation. This paper also characterizes the performance of different methods for translating the unbalanced voltage phasors into a balanced representation in order to give recommendations for modeling coupled transmission and distribution systems.

power distribution↗

Energy management systems for forecasted demand error compensation using hybrid energy storage system in nanogrid

This paper proposes an energy management system (EMS) for nanogrids to balance the power supply and forecasted demand in consideration of forecasting errors arising from high instantaneous demand. The proposed EMS employs a power-balancing optimization process for forecasted demand and a reference power modulation strategy for forecasting errors. This power-balancing optimization utilizes nanogrid sources, such as photovoltaics, fuel cells, and batteries, to meet forecasted demand and a supercapacitor charging process to overcome issues with a low energy density. The proposed reference power modulation strategy is utilized to allocate power from a hybrid energy storage system consisting of a battery and supercapacitor in order to compensate for forecasting errors. In addition, this proposed strategy considers battery and supercapacitor constraints such as the power changing rate and total power limitations. Further, the power-balancing optimization process also operates at faster sampling rate than the reference power modulation process in order to improve the computational efficiency. The performance of the proposed EMS is evaluated using real data obtained from the Korea Electric Power Exchange.

25 ENERGY STORAGE↗

Europe’s energy policy based on large-scale use of renewables most likely will require supplemental power supplies to balance their electrical power systems

Political decisions toward an increased role for renewable energy sources (wind & solar) in Europe will have an impact on the functioning of the electrical power systems that will have to be offset due to the inherent intermittent nature of renewable sources. The offset can be accomplished either through increasing non-renewable energy supply and production from other means, including purchasing Russian piped natural gas and LNG, or decreasing demand by curtailing power consumption. Europe likely will also need increased energy supplies to cover reduced gas production in the North Sea and Netherlands. Also, expected disconnection of Baltic states from the BRELL (Belarus-Russia-EstoniaLatvia-Lithuania) grid will force these countries to acquire electricity from Europe, resulting in increased demands on the European power grid that will require additional capacity to offset.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Scalable Predictive Control and Optimization for Grid Integration of Large-Scale Distributed Energy Resources

Integrating a large number of distributed energy resources (DERs) into the power grid needs a scalable power balancing method. We formulate the power balancing problem as a look-ahead optimization problem to be solved sequentially by a power distribution system aggregator based on a model predictive control (MPC) framework. Solving large-scale look-ahead control problems requires proper configuration of the control steps. In this paper, to solve large-scale control problems, we propose a variable time granularity where control time steps nearby the current control step have finer resolutions. The aggregator objective includes maximization of power production revenue and minimization of power purchasing expense, renewable power curtailment, and mileage costs for energy storage and electric vehicle (EV) charging stations while satisfying system capacity and operational constraints. The control problem is formulated as a mixed-integer linear program (MILP) and solved using the XpressMP solver. We perform simulations considering a copper plate representation of a large distribution network consisting of 2507 devices (control-lable DERs), including curtailable photovoltaics (PVs), energy storage batteries, EV charging stations, and buildings with heating, ventilation, and air conditioning units (HVACs). We show the effectiveness of the proposed approach in managing DERs interactively for maximum energy trading profit and local supply-demand power balancing. Finally, we demonstrate that the proposed method outperforms other benchmark controllers regarding computation time without compromising operational performance.

DER↗

Scalable Predictive Control and Optimization for Grid Integration of Large-Scale Distributed Energy Resources: Preprint

Integration of a large number of distributed energy resources (DERs) into the power grid needs a scalable power balancing method. We formulate the power balancing problem as a look-ahead optimization problem to be solved sequentially by a power distribution system aggregator based on a model predictive control (MPC) framework. Solving large-scale look-ahead control problem requires proper configuration of the control steps. In this paper, to solve large-scale control problems, we propose a variable time granularity where control time steps nearby the current control step have finer resolutions. The aggregator objective includes maximization of power production revenue and minimization of power purchasing expense, renewable power curtailment, and mileage costs for energy storage and electric vehicle (EV) charging stations while satisfying system capacity and operational constraints. The control problem is formulated as a mixed-integer linear program (MILP) and solved using the XpressMP solver. We perform simulations considering a copper plate representation of a large distribution network consisting of 2507 devices (controllable DERs) including curtailable photovoltaics (PVs), energy storage batteries, EV charging stations, and buildings with heating, ventilation, and air conditioning units (HVACs). We show the effectiveness of the proposed approach in managing DERs interactively for maximum energy trading profit and local supply-demand power balancing. Finally, we demonstrate that the proposed method outperformed other benchmark controllers regarding computation time without compromising operational performance.

DER↗

Computational and numerical analysis of AC optimal power flow formulations on large-scale power grids

We report that alternating current optimal power flow (AC-OPF) is a fundamental tool in electric utilities to determine optimal operation of the various resources. Typically, the AC-OPF problem uses power balance formulation containing voltages and power equations. Yet, there is no comprehensive comparison of the different AC-OPF formulations, especially for large-scale networks. This paper presents a detailed comparative evaluation of different formulations of the AC-OPF problem on networks ranging from 9-bus to 25,000 buses. Three different formulations: 1) power balance with polar voltages, 2) power balance with Cartesian voltages, and 3) current balance with Cartesian voltages are discussed in detail by comparing their characteristics, and numerical and computational performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Scalable Predictive Control and Optimization for Grid Integration of Large-Scale Distributed Energy Resources

Integrating a large number of distributed energy resources (DERs) into the power grid needs a scalable power balancing method. We formulate the power balancing problem as a look-ahead optimization problem to be solved sequentially by a power distribution system aggregator based on a model predictive control (MPC) framework. Solving large-scale look-ahead control problems requires proper configuration of the control steps. In this paper, to solve large-scale control problems, we propose a variable time granularity where control time steps nearby the current control step have finer resolutions. The aggregator objective includes maximization of power production revenue and minimization of power purchasing expense, renewable power curtailment, and mileage costs for energy storage and electric vehicle (EV) charging stations while satisfying system capacity and operational constraints. The control problem is formulated as a mixed-integer linear program (MILP) and solved using the XpressMP solver. We perform simulations considering a copper plate representation of a large distribution network consisting of 2507 devices (controllable DERs), including curtailable photovoltaics (PVs), energy storage batteries, EV charging stations, and buildings with heating, ventilation, and air conditioning units (HVACs). We show the effectiveness of the proposed approach in managing DERs interactively for maximum energy trading profit and local supply-demand power balancing. Finally, we demonstrate that the proposed method outperforms other benchmark controllers regarding computation time without compromising operational performance.

DER↗

Computational Algorithms for Unit Commitment with AC Power Flows (Final Report)

Security-constrained unit commitment (SCUC) is a key component in power system operations. When AC power flow constraints are considered in the SCUC model (AC-SCUC), the problem becomes extremely difficult due to its discrete and non-convex nature, as described in “Grid Optimization Competition Challenge 3 Problem Formulation (GOCC)”. There are four main challenges: (i) Discrete decisions regarding unit online/offline status and start-up/shut-down procedures for every single unit. The number of discrete decision variables increases considerably when a system integrates multiple generators; (ii) Configuration-based combined-cycle formulations, and multi-commodity models that include ramping products, spin/non-spin products, and regulation up/down products. The combined-cycle units introduce additional discrete decision variables and auxiliary service products further complicate the model by connecting multi-commodity products’ continuous and discrete variables; (iii) SCUC models with AC power flow constraints are far more complex due to massive bilinear terms in the large-scale nonlinear power balance equations. The nonlinear power balance equations are further complicated by the discrete step control variables of shunts; (iv) N − 1 contingency analysis. The size of the model increases linearly with the number of contingencies considered, greatly increasing the size of the optimization model. Accordingly, there is an emergent need to develop a robust algorithm capable of deriving a high-quality solution in a short time and passing through contingency tests simultaneously. In this project, we explore innovative techniques to address this challenging problem by integrating advanced polyhedral theory, approximation methods, relaxation strategies, decomposition techniques, and parallel computing. Each technique approaches the problem from a different perspective, leveraging its specific strengths to tackle distinct challenges. Each individual method has demonstrated its effectiveness in the PI’s previous research. Their integration is expected to significantly reduce the computational time required to solve the proposed complex problem. Successful completion of this project has the potential to transform the industry by enhancing optimization solvers capable of handling large-scale day-ahead energy market clearing models within strict time constraints, while incorporating AC power flow constraints. This advancement will lead to reduced overall generation costs and, consequently, increased social welfare.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗