Search NASA⌕ Search

SEARCH · Search NASA

Results for “power corrections”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Control of Dual-Opposed Stirling Convertors with Active Power Factor Correction Controllers

When using recently-developed active power factor correction (APFC) controllers in power systems comprised of dual-opposed free-piston Stirling convertors, a variety of configurations of the convertors and controller(s) can be considered, with configuration ultimately selected based on benefits of efficiency, reliability, and robust operation. The configuration must not only achieve stable control of the two convertors, but also synchronize and regulate motion of the pistons to minimize net dynamic forces. The NASA Glenn Research Center (GRC) System Dynamic Model (SDM) was used to study ten configurations of dual-opposed convertor systems. These configurations considered one controller with the alternators connected in series or in parallel, and two controllers with the alternators not connected (isolated). For the configurations where the alternators were not connected, several different approaches were evaluated to synchronize the two convertors. In addition, two thermodynamic configurations were considered: two convertors with isolated working spaces and convertors with a shared expansion space. Of the ten configurations studied, stable operating modes were found for four. Three of those four had a common expansion space. One stable configuration was found for the dual-opposed convertors with separate working spaces. That configuration required isochronous control of both convertors, and two APFC controllers were used to accomplish this. A frequency/phase control loop was necessary to allow each APFC controller to synchronize its associated convertor with a common frequency.

Regan, Timothy F.↗

Control of Dual-Opposed Stirling Convertors with Active Power Factor Correction Controllers

When using recently-developed active power factor correction (APFC) controllers in power systems comprised of dual-opposed free-piston Stirling convertors, a variety of configurations of the convertors and controller(s) can be considered, with configuration ultimately selected based on benefits of efficiency, reliability, and robust operation. The configuration must not only achieve stable control of the two convertors, but also synchronize and regulate motion of the pistons to minimize net dynamic forces. The NASA Glenn Research Center (GRC) System Dynamic Model (SDM) was used to study ten configurations of dual-opposed convertor systems. These configurations considered one controller with the alternators connected in series or in parallel, and two controllers with the alternators not connected (isolated). For the configurations where the alternators were not connected, several different approaches were evaluated to synchronize the two convertors. In addition, two thermodynamic configurations were considered: two convertors with isolated working spaces and convertors with a shared expansion space. Of the ten configurations studied, stable operating modes were found for four. Three of those four had a common expansion space. One stable configuration was found for the dual-opposed convertors with separate working spaces. That configuration required isochronous control of both convertors, and two APFC controllers were used to accomplish this. A frequency/phase control loop was necessary to allow each APFC controller to synchronize its associated convertor with a common frequency.

Regan, Timothy F.↗

Optimization, Design, and Demonstration of 1 kW Stirling Controller Using Capacitor-based Power Factor Correction

Free-piston Stirling convertors provide efficient, reliable thermal to electric power conversion, provided they are paired with a reliable controller. This paper outlines work underway on design concepts for kilowatt-class controllers. Using passive power factor correction (PFC) this design explores the possibility of reducing programmatic risk through system simplification. Efficiency is maximized through incorporating wide-bandgap gallium nitride (GaN) switches, and passive PFC volume is minimized through the use of polymer multi-layer capacitors. This work is aimed at exploring new approaches for future Stirling controllers.

Christopher Barth↗

Design of 1 kW Simplified Stirling Controller Using Capacitor-Based Power Factor Correction

Free-piston Stirling convertors hold potential for efficient, reliable thermal to electric power conversion, provided they are paired with a robust controller. This paper outlines work underway on a system-level optimization of a kW controller. Using simplified control and passive power factor correction (PFC) this design explores the possibility of reducing programmatic risk through system simplification. Efficiency is improved through incorporating wide-bandgap gallium nitride (GaN) switches, and PFC volume is minimized through the use of polymer multi-layer capacitors. This work is aimed at exploring new approaches for future Stirling space power concepts.

Stirling↗

Quasi-optimal decoding of linear block codes using soft decision detection

A simple but effective decoding procedure, applicable to any (n,k) linear block code with symbols from GF(q), is described. The technique involves a transformation of the parity check equations which focuses the code's correction power on the soft symbol set while still retaining the capability to correct one symbol error from outside this set. The soft symbol set is defined to be the n-k least reliably detected code symbol positions whose parity check row-spaces are linearly independent. The process generates a number of error vector screening candidates, each a solution to the parity check equations, and the maximum-likelihood candidate is accepted.

Greene, E. P.↗

Debris Collision Warning Sensor (DCWS) telescope design

The 60-cm diameter, f/2 DCWS telescope is a modified Ritchey Chretein configuration which collects radiation in three spectral bands, 0.4 to 0.9/micron (visible), 5.0 to 9.0/microns (MWIR), and 9.0 to 12.0 microns (LWIR). The visible and infrared radiation are separated by a dichroic beamsplitter and focused on to separate focal planes; the MWIR and LWIR radiation share a common focal plane with separate detector arrays residing side-by-side. The conic constants of the primary and secondary mirrors are that of a Ritchey Chretein telescope; to improve the image quality at the edges of the field of view, a set of zero power correcting optics have been introduced to each optical train. The Ritchey Chretein telescope is corrected to have zero third order spherical aberration and zero third order coma; the DCWS telescope is further configured such that the positive power in the primary mirror is approximately equal to the negative power in the secondary mirror, resulting in a telescope with very little field curvature.

Brown, Robert J.↗

Electric Power Monitor

Control center for SAMAC (System Automatic Monitor and Control) is a sophisticated dispatch computer system, developed by Rockwell International and operated by Philadelphia Electric Co. SAMAC monitors and controls the generation and distribution of electric power throughout the Philadelphia electric network. With the assistance of NASA's Apollo computer system technology, it enables human operators to isolate and correct power distribution problems more rapidly than was possible with earlier dispatch systems without centralized computer control.

Source record↗

Polarization-sensitive spectroradiometer - Two methods for overcoming the problems of measuring reflectance spectra

The spectra obtained using a spectroradiometer are incorrect if the incident light from the sample is polarized, and if, at the same time, polarization is introduced into the transmitted beam by components of the spectroradiometer. Two methods are proposed for obtaining correct power reflectance spectra. One way is to average two incorrect reflectance spectra, which are taken at mutually orthogonal angles of rotation of the radiometer about its optical axis. Another way is by averaging reflectance spectra of mutually orthogonal polarized light components. When the orientation of one component is chosen such that it is in the plane of polarization of the incoming light, the latter method also gives the correct degree of polarization.

Auer, S.↗

On the use of colour reflectivity plots to monitor the structure of the troposphere and stratosphere

The radar reflectivity, defined as the range squared corrected power of VHF radar echoes, can be used to monitor and study the temporal development of inversion layer, frontal boundaries and convective turbulence. From typical featurs of upward or downward motion of reflectivity structures, the advection/convection of cold and warm air can be predicted. High resolution color plots appear to be useful to trace and to study the life history of these structures, particularly their persistency, descent and ascent. These displays allow an immediate determination of the tropopause height as well as the determination of the tropopause structure. The life history of warm fronts, cold fronts, and occlusions can be traced, and these reflectivity plots allow detection of even very weak events which cannot be seen in the traditional meteorological data sets. The life history of convective turbulence, particular evolving from the planetary boundary layer, can be tracked quite easily. Its development into strong convection reaching the middle troposphere can be followed and predicted.

Rottger, J.↗

Trace-shortened Reed-Solomon codes

Reed-Solomon (RS) codes have been part of standard NASA telecommunications systems for many years. RS codes are character-oriented error-correcting codes, and their principal use in space applications has been as outer codes in concatenated coding systems. However, for a given character size, say m bits, RS codes are limited to a length of, at most, 2(exp m). It is known in theory that longer character-oriented codes would be superior to RS codes in concatenation applications, but until recently no practical class of 'long' character-oriented codes had been discovered. In 1992, however, Solomon discovered an extensive class of such codes, which are now called trace-shortened Reed-Solomon (TSRS) codes. In this article, we will continue the study of TSRS codes. Our main result is a formula for the dimension of any TSRS code, as a function of its error-correcting power. Using this formula, we will give several examples of TSRS codes, some of which look very promising as candidate outer codes in high-performance coded telecommunications systems.

Mceliece, R. J.↗

From Goal-Oriented Requirements to Event-B Specifications

In goal-oriented requirements engineering methodologies, goals are structured into refinement trees from high-level system-wide goals down to fine-grained requirements assigned to specific software/ hardware/human agents that can realise them. Functional goals assigned to software agents need to be operationalised into specification of services that the agent should provide to realise those requirements. In this paper, we propose an approach for operationalising requirements into specifications expressed in the Event-B formalism. Our approach has the benefit of aiding software designers by bridging the gap between declarative requirements and operational system specifications in a rigorous manner, enabling powerful correctness proofs and allowing further refinements down to the implementation level. Our solution is based on verifying that a consistent Event-B machine exhibits properties corresponding to requirements.

Aziz, Benjamin↗

Tracking and data relay satellite fault isolation and correction using PACES: Power and attitude control expert system

The Power and Attitude Control Expert System (PACES) is an object oriented and rule based expert system which provides spacecraft engineers with assistance in isolating and correcting problems within the Power and Attitude Control Subsystems of the Tracking and Data Relay Satellites (TDRS). PACES is designed to act in a consultant role. It will not interface to telemetry data, thus preserving full operator control over spacecraft operations. The spacecraft engineer will input requested information. This information will include telemetry data, action being performed, problem characteristics, spectral characteristics, and judgments of spacecraft functioning. Questions are answered either by clicking on appropriate responses (for text), or entering numeric values. A context sensitive help facility allows access to additional information when the user has difficulty understanding a question or deciding on an answer. The major functionality of PACES is to act as a knowledge rich system which includes block diagrams, text, and graphics, linked using hypermedia techniques. This allows easy movement among pieces of the knowledge. Considerable documentation of the spacecraft Power and Attitude Control Subsystems is embedded within PACES. The development phase of TDRSS expert system technology is intended to provide NASA with the necessary expertise and capability to define requirements, evaluate proposals, and monitor the development progress of a highly competent expert system for NASA's Tracking and Data Relay Satellite Program.

Erikson, Carol-Lee↗

Single Phase Passive Rectification Versus Active Rectification Applied to High Power Stirling Engines

Stirling engine converters are being considered as potential candidates for high power energy conversion systems required by future NASA explorations missions. These types of engines typically contain two major moving parts, the displacer and the piston, in which a linear alternator is attached to the piston to produce a single phase sinusoidal waveform at a specific electric frequency. Since all Stirling engines perform at low electrical frequencies (less or equal to 100 Hz), space explorations missions that will employ these engines will be required to use DC power management and distribution (PMAD) system instead of an AC PMAD system to save on space and weight. Therefore, to supply such DC power an AC to DC converter is connected to the Stirling engine. There are two types of AC to DC converters that can be employed, a passive full bridge diode rectifier and an active switching full bridge rectifier. Due to the inherent line inductance of the Stirling Engine-Linear Alternator (SE-LA), their sinusoidal voltage and current will be phase shifted producing a power factor below 1. In order to keep power the factor close to unity, both AC to DC converters topologies will implement power factor correction. This paper discusses these power factor correction methods as well as their impact on overall mass for exploration applications. Simulation results on both AC to DC converters topologies with power factor correction as a function of output power and SE-LA line inductance impedance are presented and compared.

Santiago, Walter↗

Calculation of the relativistic Bloch correction to stopping power

Bloch's technique of joining the nonrelativistic Bethe and Bohr stopping-power expressions by taking into account wave-packet effects for close collisions is extended to the relativistic case. It is found that Bloch's nonrelativistic correction term must be modified and that charge asymmetric terms appear. Excellent agreement is observed by comparing the results of these calculations to recent data on the stopping power of relativistic heavy ions.

Ahlen, S. P.↗

A Study on Effect of Tuning Capacitor in Dynamic Radioisotope Power Systems

This study presents the effect of the tuning capacitor on stability and electrical power output of a gas-bearing based free-piston Stirling convertor (FPSC) when operating on a fixed-frequency type controller. It has been widely accepted that the tuning capacitor is an important circuit component of the FPSC to stabilize piston amplitude and maximize electrical power output by correcting the power factor. Models suggest the stability of the FPSC is strongly coupled to the tuning capacitance, while the coupling to the electrical power output is weak. This applies to cases where the operating frequency of the FPSC is fixed by a fixed-frequency controller and other operating conditions, such as the hot-end and cold-end temperatures, piston amplitude, and pressure are constant. To verify the modeling analysis results, an Advanced Stirling Convertor (ASC) was controlled by an AC power supply and the piston amplitude, hot-end temperature, cold-end temperature, and pressure are actively controlled to 4.3mm, 760˚C, 40˚C and 485psig, respectively, while the tuning capacitor value was changed from 840μF to 1040μF and 1240μF. Furthermore, the vibration test results of the ASC with different tuning capacitor values are also presented to show the effect of the tuning capacitor on stability. The experimental test results verified that the effect of tuning capacitor on electrical power output is negligible while the effect on stability is rather noticeable. Therefore, the ideal tuning capacitor value should be selected based on required stability of the FPSC.

Free-Piston Stirling Convertor Controller↗

A Study on Effect of Tuning Capacitor in Dynamic Radioisotope Power Systems

This study presents the effect of the tuning capacitor on the stability and electrical power output of a gas spring-based free-piston Stirling convertor (FPSC) when the FPSC runs on a forced-oscillation type controller. It has been widely accepted that the tuning capacitor is an important circuit component of the FPSC to stabilize piston amplitude and maximize electrical power output by correcting the power factor. Recent modeling analysis, however, suggests that while the effect on the stability is significant, the effect on the electrical power output is almost negligible as long as the operating frequency the FPSC is fixed by a forced-oscillation controller and operating conditions, such as the hot-end/cold-end temperatures, piston amplitude, and pressure, are unchanged. To verify the modeling analysis results, Advanced Stirling Convertor (ASC) is controlled by an AC power supply and the piston amplitude, hot-end temperature, cold-end temperature, and pressure are actively controlled to 4.3mm, 760˚C, 40˚C and 485psig, respectively, while the tuning capacitor value is changed from 840μF to 1040μF and 1240μF. Furthermore, the vibration test results of the ASC with the three tuning capacitor values are also presented to show the effect of the tuning capacitor on stability. The test results suggest that when the FPSC operates at a fixed frequency, the effect of tuning capacitor on electrical power output is negligible while the effect on stability is rather significant. Therefore, the tuning capacitor value should be selected toward the highest stability.

Free-Piston Stirling Convertor Controller↗