Search NASA⌕ Search

SEARCH · Search NASA

Results for “power duration curve”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Life-Cycle Cost and Optimization of PV Systems Based on Power Duration Curve with Variable Performance Ratio and Availability

A new derivation of Power Duration Curve is presented and applied to analysis of photovoltaic system life cycle cost. The effect of non-unity Performance Ratio and non-unity Availability on the power duration curve are illustrated. The effect of these two key performance indicators on calculation of life cycle cost and PV system design optimization (optimal DC/AC ratio) are illustrated as example applications of the method.

14 SOLAR ENERGY↗

Adaptive cold-load pickup considerations in 2-stage microgrid unit commitment for enhancing microgrid resilience

In an extended main grid outage spanning multiple days, load shedding serves as a critical mechanism for islanded microgrids to maintain essential power and energy reserves that are indispensable for fulfilling reliability and resiliency mandates. However, using load shedding for such purposes leads to increasing occurrence of cold load pickup (CLPU) events. Here, this study presents an innovative adaptive CLPU model that introduces a method for determining and incorporating parameters related to CLPU power and energy requirements into a two-stage microgrid unit commitment (MGUC) algorithm. In contrast to the traditional fixed-CLPU-curve approach, this model calculates CLPU duration, power, and energy demands by considering outage durations and ambient temperature variations within the MGUC process. By integrating the adaptive CLPU model into the MGUC problem formulation, it allows for the optimal allocation of energy resources throughout the entire scheduling horizon to fulfill the CLPU requirements when scheduling multiple CLPU events. The performance of the enhanced MGUC algorithm considering CLPU needs is assessed using actual load and photovoltaic (PV) data. Simulation results demonstrate significant improvements in dispatch optimality evaluated by the amount of load served, customer comfort, energy storage operation, and adherence to energy schedules. These enhancements collectively contribute to reliable and resilient microgrid operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Comprehensive Model for Analyzing the Effects of Power Outages on Customers

Power outages can cause significant inconveniences to critical services and substantial economic losses. Therefore, it is crucial to systematically analyze the impact on customers during power outages caused by various factors, such as severe thunderstorms, floods, vegetation, or mechanical problems, and to plan for reliable operation and control under such events. Power outages in different locations may exhibit varying characteristics regarding customer impact. In this paper, we present a mathematical model that captures the essential characteristics of customer impact during power outages. The parameters of our model include impact duration, recovery duration, maximum impact level, increase curve parameter, and decrease curve parameter. We demonstrate how historical power outage data can be fitted to our model, enabling a systematic comparison of outages caused by different factors in various locations.

Lee, Sangkeun (Matt) [ORNL] (ORCID:000000021317511↗

Multi-facility analysis using metered power data to quantify MRI energy use and utility bill costs across scanner operating modes

This study quantifies the energy consumption of magnetic resonance imaging (MRI) scanners across discrete operating modes during routine clinical workflows, based solely on electrical power measurements. Although previous studies have investigated MRI energy consumption within single hospitals or specific clinical settings, this research provides a broader and more systematic analysis. Researchers analyzed electrical power data and applied a previously developed semi-automatic method for identifying MRI operating modes using load duration curves for 20 MRI scanners across four different U.S. healthcare facilities, encompassing outpatient, inpatient, and mixed-use clinical settings. A key innovation is the inclusion of localized hourly utility rates to estimate costs, a parameter absent in prior literature. Key findings indicate significant variability in energy and cost profiles between weekdays and weekends. Scanner characteristics, including magnet strength, manufacturer, vintage, location, and clinical setting, influenced average daily energy consumption and power thresholds for operating modes. Notably, the clinical setting of a scanner predominantly determines its energy use. For example, the scanners in outpatient facilities consumed more energy. The breakdown of energy usage and costs by operating modes showed scanners spend between 61% and 93% of their time in nonproductive modes, with one outlier spending 34%. Average daily energy use for the scanners in the study ranged from 160 to 1069 kWh, with energy costs ranging from $\$$9 to $\$$149. This study uses an existing framework to quantify MRI energy behavior, leading to insights that can enable improved performance and cost savings across different healthcare environments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Generation of straight and curved hollow plasma channels by laser-generated nonlinear wakefields and studies of ultra-intense laser pulse guiding

We report on a study of highly controllable, quasi-static hollow plasma channels generated by ion motion following a laser–plasma interaction via numerical simulations. These channels are generated by ion motion in a nonlinear wakefield, which has an asymmetry between focusing and defocusing periods. Such plasma channels, driven by a fs duration, 100 TW level laser pulse, have the capability to guide more powerful laser pulses. Moreover, we show that curved plasma channels can be generated in a transverse density gradient plasma and alloptical guiding of a second, significantly more powerful laser pulse in such a curved plasma channel. This mechanism may be useful for creating plasma optics for multi-stage TeV laser plasma accelerators and compact synchrotron radiation sources.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Dark Energy Survey Supernova Program: slow supernovae show cosmological time dilation out to z ~ 1.

ABSTRACT We present a precise measurement of cosmological time dilation using the light curves of 1504 Type Ia supernovae from the Dark Energy Survey spanning a redshift range $0.1\lesssim z\lesssim 1.2$. We find that the width of supernova light curves is proportional to $(1+z)$, as expected for time dilation due to the expansion of the Universe. Assuming Type Ia supernovae light curves are emitted with a consistent duration $\Delta t_{\rm em}$, and parametrizing the observed duration as $\Delta t_{\rm obs}=\Delta t_{\rm em}(1+z)^b$, we fit for the form of time dilation using two methods. First, we find that a power of $b \approx 1$ minimizes the flux scatter in stacked subsamples of light curves across different redshifts. Secondly, we fit each target supernova to a stacked light curve (stacking all supernovae with observed bandpasses matching that of the target light curve) and find $b=1.003\pm 0.005$ (stat) $\pm \, 0.010$ (sys). Thanks to the large number of supernovae and large redshift-range of the sample, this analysis gives the most precise measurement of cosmological time dilation to date, ruling out any non-time-dilating cosmological models at very high significance.

79 ASTRONOMY AND ASTROPHYSICS↗

Black hole to breakout: 3D GRMHD simulations of collapsar jets reveal a wide range of transients

We present a suite of the first 3D GRMHD collapsar simulations, which extend from the self-consistent jet launching by an accreting Kerr black hole (BH) to the breakout from the star. We identify three types of outflows, depending on the angular momentum, l, of the collapsing material and the magnetic field, B, on the BH horizon: (i) subrelativistic outflow (low l and high B), (ii) stationary accretion shock instability (SASI; high l and low B), (iii) relativistic jets (high l and high B). In the absence of jets, free-fall of the stellar envelope provides a good estimate for the BH accretion rate. Jets can substantially suppress the accretion rate, and their duration can be limited by the magnetization profile in the star. We find that progenitors with large (steep) inner density power-law indices (≳ 2), face extreme challenges as gamma-ray burst (GRB) progenitors due to excessive luminosity, global time evolution in the light curve throughout the burst and short breakout times, inconsistent with observations. Our results suggest that the wide variety of observed explosion appearances (supernova/supernova + GRB/low-luminosity GRBs) and the characteristics of the emitting relativistic outflows (luminosity and duration) can be naturally explained by the differences in the progenitor structure. Our simulations reveal several important jet features: (i) strong magnetic dissipation inside the star, resulting in weakly magnetized jets by breakout that may have significant photospheric emission and (ii) spontaneous emergence of tilted accretion disc-jet flows, even in the absence of any tilt in the progenitor.

79 ASTRONOMY AND ASTROPHYSICS↗

A semi–automatic analytical methodology for characterizing the energy consumption of MRI systems using load duration curves

Background and purpose: Magnetic resonance imaging (MRI) scanners are a major contributor to greenhouse gas emissions from the healthcare sector, and efforts to improve energy efficiency and reduce energy consumption rely on quantification of the characteristics of energy consumption. The purpose of this work was to develop a semi-automatic analytical methodology for the characterization of the energy consumption of MRI systems using only the load duration curve (LDC). LDCs are a fundamental tool used across various fields to analyze and understand the behavior of loads over time. Methods: An electric current transformer sensor and data logger were installed on two 3T MRI scanners from two vendors, termed M1 (outpatient scanner) and M2 (inpatient/emergency scanner). Data was collected for 1 month (7/11/2023 to 8/11/2023). Active power was calculated, assuming a balanced three-phase system, using the average current measured across all three phases, a 480 V reference voltage for both machines, and vendor-provided power factors. An LDC was constructed for each system by sorting the active power values in descending order and computing the cumulative time (in units of percentage) for each data point. The first derivative of the LDC was then computed (LDC’), smoothed by convolution with a window function (sLDC’), and used to detect transitions between different system modes including (in descending power levels): scan, prepared-to-scan, idle, low-power, and off. The final, segmented LDC was used to measure time (% total time), total energy (kWh), and mean power (kW) for each system mode on both scanners. The method was validated by comparing mean power values, computed using the segmented 1-month LDC, for each nonproductive system mode (i.e., prepared-to-scan, idle, lower-power, and off) against power levels measured after a deliberate system shutdown was performed for each scanner (1 day worth of data). Results: The validation revealed differences in mean power values <1.4% for all nonproductive modes and both scanners. In the scan system mode, the mean power values ranged from 29.8 to 37.2 kW and the total energy consumed for 1 month ranged from 11 106 to 14 466 kWh depending on the scanner. Over the course of 1 month, the portion of time the scanners were in nonproductive modes ranged from 76% to 80% across scanners and the nonproductive energy consumption ranged from 8010 to 6722 kWh depending on the scanner. The M1 (outpatient) scanner consumed 99.9 and 183.9 kWh/day in idle mode for weekdays and weekends, respectively, because the scanner spent 23% more time proportionally in idle mode on the weekends. Conclusions: A semi-automatic method for quantifying energy consumption characteristics of MRI scanners was introduced and validated. This method is relatively simple to implement as it requires only power data from the scanners and avoids the technical challenges associated with extracting and processing scanner log files. Finally, the methodology enables quantitative evaluation of the power, time, and energy characteristics of MRI scanners in scan and nonproductive system modes, providing baseline data and the capability of identifying potential opportunities for enhancing the energy efficiency of MRI scanners.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Economic Dispatch Model of Nuclear High-Temperature Reactor with Hydrogen Cogeneration in Electricity Market

Hydrogen produced without carbon emissions could be a useful fuel as nations look to decarbonize their electricity, transport, and industry sectors. Using the iodine–sulfur (IS) cycle coupled with a nuclear heat source is one method for producing hydrogen without the use of fossil fuels. An economic dispatch model was developed for a nuclear-driven IS system to determine hydrogen sale prices that would make such a system profitable. The system studied is the HTTR-GT/H2, a design for power and hydrogen cogeneration at the Japan Atomic Energy Agency’s High Temperature Engineering Test Reactor. This study focuses on the development of the economic model and the role that input data plays in the final calculated values. Using a historical price duration curve shows that the levelized cost of hydrogen (LCOH) or breakeven sale price of hydrogen would need to be 98.1 JPY/m3 or greater. Synthetic time histories were also used and found the LCOH to be 67.5 JPY/m3. The price duration input was found to have a significant effect on the LCOH. As such, great care should be used in these economic dispatch analyses to select reasonable input assumptions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Detection and Perception of Sound by Eagles and Surrogate Raptors

One overarching objective of this program of study was the accumulation of objective, scientifically valid information relating to auditory performance of bald and golden eagles that may be used to guide the development of acoustic alerting/deterrence technologies intended to discourage encroachment into wind energy air spaces. To that end, analyses aimed at the characterization of sensitivity to sound in bald and golden eagles, along with findings in the supra-threshold, dynamic frequency spaces related to response latencies and amplitudes, leads us to conclude that bald, and golden eagles navigate the same basic working auditory space, as in other known and thus far characterized members of the diurnal raptor family. Specifically, bald and golden eagles, along with other raptor species within the group, operate in an auditory space characterized by a frequency band at least four octaves wide and centered on 2 kHz, with an upper frequency limit between 6 and 10 kHz at 80 dB SPL and a lower frequency limit that almost certainly extends below 0.2 kHz. Consequently, we recommend that signal designers use these data as a guideline in efforts to design effective and efficient acoustic alerting/deterrent systems. It is important to note that signal energy broadcast outside of this frequency band at moderate levels will not contribute to the efficacy of a deterrent but will add an unnecessary fraction to the overall acoustic pollution budget. The importance of this consideration is heightened by contemporaneous concerns related to the transmission of noise broadcast by wind energy farms. In addition, based on analyses of data acquired from red-tailed hawks using the same experimental paradigm and data acquisition system, we conclude that auditory function in the red-tailed hawk is sufficiently like that observed in bald and golden eagles to permit its use as a surrogate species. Response waveforms, threshold-frequency curves, and input-output characteristics match those of eagles closely. It should be noted however, that differences in sensitivity and slightly extended high-frequency limits of hearing should be taken into account when extrapolating findings from one species to the others. Although the inclusion of behavioral tests of red-tailed hawks to acoustic stimuli was beyond the scope of this investigation, future efforts to assess response parameters like signal-type preference and habituation rate will further elucidate their suitability to serve as eagle surrogates in behavioral studies; nonetheless, the species in question are well matched with respect to basic auditory performance. A second essential objective of this program of study was the acoustic characterization of a subset of calls comprising the vocal repertoires of bald and golden eagles that may be used to supplement auditory performance findings in the effort to guide the development of acoustic alerting signals. With regard to that objective, the vocal repertoires of both bald and golden eagle species are rich and varied. While similar in spectrographic structure, distinctive differences are also clear. Generally, golden eagles produce some calls with shorter durations, and similar “sounding” calls exhibit distinctively different spectrographic patterns than those of bald eagles. Both species produce calls that contain a wide variety of nonlinear elements that operate to enhance the rich and varied nature of commonly observed vocal products. Comparison of the average power spectra of commonly observed bald and golden eagle calls with threshold-frequency curves leads to the conclusion that call energies fall within the frequency bounds of hearing. Further, the acoustic energy of calls considered in this report tend to fall into overlapping, but different frequency ranges of the acoustic sensitivity curve. This condition may encourage signal designers to vary the frequency content of acoustic deterrence signals in the field. Finally, preliminary observations relating to the tendencies and proclivities of bald eagles to attend to the acoustic landscape lead to the conclusion that eagles monitor their immediate sound environment assiduously. Individuals respond to a variety of natural and synthetic sound signals reliably and, perhaps most relevant in the context of the engineering of acoustic alerting/deterrence technologies, habituation to most sounds considered in this effort was minimal. These preliminary results, while calling for extended behavioral testing, are promising and set the stage for the exportation of behavioral studies into real world scenarios.

17 WIND ENERGY↗

Analysis of Historical Power Outages of the United States and the National Risk Index

Several works have been documented in the literature to study the societal effect of power outages and to analyze their correlation with the Social Vulnerability Index (SVI). However, the relationship between National Risk Index (NRI) and power outages is yet to be explored. This work analyzes the NRI indices such as Risk, Expected Annual Loss, Social Vulnerability, and Community Resilience with several resilience metrics such as event duration, impact duration, recovery duration, impact level, impact rate, recovery rate, recovery to impact ratio, and area under the outage curves to see the correlation of NRI indices with the resilience metrics. The results show that NRI indices such as Risk and Expected Annual Loss increase with the increase of event duration, impact duration, and recovery duration. All Other metrics are indifferent to the change in the Risk and EAL ratings. The results also show that there is no strong relationship between all the metrics and community resilience and social vulnerability. This work also performed the sensitivity analysis of the extreme event selection process. This sensitivity analysis reveals that the way of identifying extreme events has a significant impact on the evaluation of the events.

Bhusal, Narayan↗

Degradation mechanisms and partial shading of glass-backsheet and double-glass photovoltaic modules in three climate zones determined by remote monitoring of time-series current–voltage and power datastreams

Degradation and partial shading impact the long-term reliability and power production of photovoltaic (PV) modules and power plants. Time-series power (P mp ) and current–voltage (I-V) curve datastreams from PV modules enable a remote diagnostic approach to quantify active degradation mechanisms and identify partial shading. We study three to nine years of these datastreams, including 3.6 million P mp I-V curves and 36 million values, from eight PV modules, four each of double-glass and glass-backsheet module architectures, located in three distinctly different Köppen-Geiger climate zones, to determine the module’s performance loss rates (PLR), identify active degradation mechanisms and power loss modes, along with partial shading by local objects. Considering both module architectures, PLR results indicate that the BSh climate zone is the most aggressive for module degradation, while the Alpine ET zone is the mildest climate. PLR of double-glass modules located in BWh and BSh climate zones are different due to the significantly greater uniform current loss (ΔP Isc ) for double-glass modules in BSh, at a 5% significance level. Power loss for four out of five modules located in the BWh and BSh climates are dominated by uniform current degradation. Statistical analysis of multistep I-V curves detects partial shading experienced by three studied modules with details of the shading profile, the shading Poynting vector diagram for the obstacle’s relative position, shading scenarios, and duration. Lastly, this work demonstrates how remote monitoring and diagnosis of P mp & I-V time-series of modules can provide quantitative operations and maintenance insights into system performance, degradation mechanisms, and shading.

14 SOLAR ENERGY↗

Carnegie Supernova Project II: The Slowest Rising Type Ia Supernova LSQ14fmg and Clues to the Origin of Super-Chandrasekhar/03fg-like Events

The Type Ia supernova (SN Ia) LSQ14fmg exhibits exaggerated properties that may help to reveal the origin of the "super-Chandrasekhar"(or 03fg-like) group. The optical spectrum is typical of a 03fg-like SN Ia, but the light curves are unlike those of any SNe Ia observed. The light curves of LSQ14fmg rise extremely slowly. At -23 rest-frame days relative to B-band maximum, LSQ14fmg is already brighter than M V = -19 mag before host extinction correction. Here, the observed color curves show a flat evolution from the earliest observation to approximately 1 week after maximum. The near-infrared light curves peak brighter than -20.5 mag in the J and H bands, far more luminous than any 03fg-like SNe Ia with near-infrared observations. At 1 month past maximum, the optical light curves decline rapidly. The early, slow rise and flat color evolution are interpreted to result from an additional excess flux from a power source other than the radioactive decay of the synthesized 56 Ni. The excess flux matches the interaction with a typical superwind of an asymptotic giant branch (AGB) star in density structure, mass-loss rate, and duration. The rapid decline starting at around 1 month past B-band maximum may be an indication of rapid cooling by active carbon monoxide (CO) formation, which requires a low-temperature and high-density environment. These peculiarities point to an AGB progenitor near the end of its evolution and the core degenerate scenario as the likely explosion mechanism for LSQ14fmg.

79 ASTRONOMY AND ASTROPHYSICS↗

Extracting Resilience Metrics From Distribution Utility Data Using Outage and Restore Process Statistics

Resilience curves track the accumulation and restoration of outages during an event on an electric distribution grid. We show that a resilience curve generated from utility data can always be decomposed into an outage process and a restore process and that these processes generally overlap in time. We use many events in real utility data to characterize the statistics of these processes, and derive formulas based on these statistics for resilience metrics such as restore duration, customer hours not served, and outage and restore rates. The formulas express the mean value of these metrics as a function of the number of outages in the event. We also give a formula for the variability of restore duration, which allows us to predict a maximum restore duration with 95% confidence. Overall, we give a simple and general way to decompose resilience curves into outage and restore processes and then show how to use these processes to extract resilience metrics from standard distribution system data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Gravity Well Commercial Economics Assessment: Potential Revenue and Cost: Cooperative Research and Development (Final Report)

In the Gravity Well Revenue Study, we evaluate the potential revenue from energy storage using historical energy-only electricity prices, forward-looking projections of hourly electricity prices, and actual reported revenue. This analysis examines the impact of storage duration and round-trip efficiency, as well as the location of the storage, on storage revenue within the current and projected U.S. power system. We also investigated the impact of round-trip efficiency on storage revenue. We found that the relationship between storage revenue and round-trip efficiency is nonlinear. The value of improved round-trip efficiency declines as round-trip efficiency increases. In the Gravity Well Future Cost Study, we applied learning curves to predict the future cost trajectory of Gravity Wells (GrWs). Two types of analysis were implemented. The first was a bottom-up analysis that used historical learning rates for cost components, such as motors and gearboxes, and cost categories (e.g., engineering and design, etc.) to determine the learning-by-doing based single-factor learning curve. The single factor learning curve expresses the relationship between the cost of GrW and the number of units deployed (or the cumulative capacity). In the second analysis, we predicted future GrW costs via a top-down approach. This approach accounts for historical cost trends in other renewable energy and storage technologies, which have similarities with GrWs. Using a multifactor learning curve that accounts for both intrinsic (cumulative capacity) and extrinsic (the elasticity in the price of steel) factors, we estimated the future cost of GrWs.

25 ENERGY STORAGE↗

Non-contact Current-Voltage (I-V) Tracer for Photovoltaics

This report presents a non-contact approach to simultaneously obtain current-voltage (I-V) curves of photovoltaic (PV) substrings and modules in a string without the need of disconnecting the individual modules from the string. There are two types of I-V curve tracers currently available in the marketplace, capacitor-based and electronic load-based. The primary requirement of these conventional I-V tracers is the disconnection of individual modules in the string so the individual modules contacted through the connectors of the individual modules. These contact-tracers have three major limitations in the utility scale power plants: First limitation – Weather and Accuracy: The mass-produced commercial contact-tracers cannot obtain the I-V curves of both string and its modules (as high as 30 modules), almost simultaneously (within about 5 minutes) at, practically, a single irradiance level, a single module temperature, a single spectrum and a single AOI (angle of incidence). This inability of the contact-tracers forces the testing personnel to wait for an extended or multiple sunny (>800 W/m 2 ) duration(s) of a cloudy day. This is a serious limitation as waiting for the sunny conditions or days is a huge practical challenge in almost all locations, except desert locations. Also, since the I-V curves are obtained at different prevailing weather conditions, it becomes critical to translate all the measured I-V curves of 30 modules in the string to a single test condition, for example STC (standard test conditions), so the underperforming modules can be identified. The accuracy of translation equations is heavily influenced by the irradiance level and temperature, spectral and AOI ranges; Second limitation - Safety: The second limitation is related to the high voltage electrical safety of the test personnel during disconnecting and reconnecting of individual modules or cable connectors from the string under daylight conditions and damaging of the original module connectors (especially the field aged connectors) during the disconnecting and reconnecting process; Third limitation – Labor: The third limitation is related to the enormous amount of time and hardship for the test personnel under prevailing (often harsh) protracted field conditions. This project was executed by Arizona State University in collaboration with its industry partner, PV Measurements Inc. (PVM). To mitigate all the three challenges of the state-of-the-art equipment indicated above, we utilized a non-contact I-V (NCIV) tracer approach. In this approach, we utilized an electrostatic voltmeter (ESV) and voltage sensor/probe combination to obtain I-V curves. The ESV units are extensively used in the high voltage industry but not in the PV industry. To obtain the simultaneous I-V curves of the substrings and modules within a string, we utilized multiple commercial ESV-Probe sets. In this approach, we utilized a non-contact voltage sensor (called, Probe) placed on the glass surface of the module (above the last cell of the module). This probe senses the module voltage (with respect to ground) through measured capacitance which is dictated by the surface charges (which in turn is dictated by the module voltage) and transmits the sensed voltage to the voltmeter (called, ESV or NCV, non-contact voltmeter). The current is sensed by a non-contact hall sensor. In a 30-module string, the 30th probe obtains the entire string I-V along with the string I-V obtained by the electronic load. so that the I-V curves of the substrings and modules can be obtained by NCIV without the need of disconnecting the individual modules in the string. The string I-V curves obtained by the electronic load and NCIV can be compared for the accuracy determination. One can use 30 ESV units and 30 Probes to obtain 30 I-V curves of a 30-module string or use just 5 ESV units and 30 Probes in conjunction with 5 six-channel switchboxes (called, 6:1 switchboxes). To reduce the equipment cost, we utilized the 6:1 switchbox approach so the number of ESV units is reduced from 30 to 5. The approaches, achievements and challenges of this project are detailed in this report.

14 SOLAR ENERGY↗

Forward Modeling of Gamma Reaction History Signatures From Anticipated Deuterium-Tritium Filled MagLIF Implosions on Sandia’s Z-Machine

Nuclear reaction history measurements provide a bang time and burn width of Inertial Confinement Fusion (ICF) implosions and are essential for understanding implosion performance to constrain ICF capsule design. When fusion fuel contains Deuterium (D) and Tritium (T) gas, reaction history is informed by measuring the 16.75 MeV gamma rays generated from the D(T,γ) 5 He reaction. Such DT based reaction history measurements have not been made on the Magnetized Laser Inertial Fusion (MagLIF) platform on Sandia’s Z-Machine due to the lack of Tritium being used. The recent development of ICF implosions with tritiated fuel will open the possibility of measuring the gamma reaction history on the Z-Machine. A forward model of the Gamma Reaction History diagnostic on Z (GRH-Z) has been developed using the MCNP6.3 (Monte-Carlo N-Particle) radiation transport code. The model included the Z-Machine geometry of interest to characterize the impact of neutron induced gamma rays on the DT reaction history measurements. In addition, the impulse response functions of the GRH-Z diagnostic to understand the temporal response of the detector, and the minimum yields required to make a reaction history measurement were calculated. This approach also predicted that with T 2 gas doping of MagLIF implosions a reaction history may be made for high performance shots >8e12-2.4e13 depending on the chosen threshold for the detector, with a maximum signal to background ratio of 25%. It was found that for long duration ICF implosions that additional collimation will be needed to prevent the neutron induced gamma rays from modifying the shape of the measured DT reaction history curve.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GRB 221009A: Discovery of an Exceptionally Rare Nearby and Energetic Gamma-Ray Burst

We report the discovery of the unusually bright long-duration gamma-ray burst (GRB), GRB 221009A, as observed by the Neil Gehrels Swift Observatory (Swift), Monitor of All-sky X-ray Image, and Neutron Star Interior Composition Explorer Mission. This energetic GRB was located relatively nearby (z = 0.151), allowing for sustained observations of the afterglow. The large X-ray luminosity and low Galactic latitude (b = 4$^°_.$3) make GRB 221009A a powerful probe of dust in the Milky Way. Using echo tomography, we map the line-of-sight dust distribution and find evidence for significant column densities at large distances (≳10 kpc). We present analysis of the light curves and spectra at X-ray and UV–optical wavelengths, and find that the X-ray afterglow of GRB 221009A is more than an order of magnitude brighter at T 0 + 4.5 ks than that from any previous GRB observed by Swift. In its rest frame, GRB 221009A is at the high end of the afterglow luminosity distribution, but not uniquely so. In a simulation of randomly generated bursts, only 1 in 10 4 long GRBs were as energetic as GRB 221009A; such a large E γ,iso implies a narrow jet structure, but the afterglow light curve is inconsistent with simple top-hat jet models. Using the sample of Swift GRBs with redshifts, we estimate that GRBs as energetic and nearby as GRB 221009A occur at a rate of ≲1 per 1000 yr—making this a truly remarkable opportunity unlikely to be repeated in our lifetime.

79 ASTRONOMY AND ASTROPHYSICS↗