Simulation of a Wireless Power Transfer System for Electric Vehicles with Power Factor Correction
Wireless power transfer has been a popular topic of recent research. Most research has been done to address the limitations of coil-to-coil efficiency. However, little has been done to address the problem associated with the low input power factor with which the systems operate. This paper details the steps taken to analyze a wireless power transfer system from the view of the power grid under a variety of loading conditions with and without power factor correction.
Single-Phase Active Boost Rectifier with Power Factor Correction for Wireless Power Transfer Applications
Wireless Power Transfer (WPT) technology is a novel research area in the charging technology that bridges utility and the automotive industries. There are various solutions that are currently being evaluated by several research teams to find the most efficient way to manage the power flow from the grid to the vehicle energy storage system. There are different control parameters that can be utilized to compensate for the change in the impedance. To understand the power flow through the system this paper presents a novel approach to the system model and the impact of different control parameters on the load power. The implementation of an active front-end rectifier on the grid side for power factor control and voltage boost capability for load power regulation is also discussed.
SiC MOSFET Based Single Phase Active Boost Rectifier with Power Factor Correction for Wireless Power Transfer Applications
Wireless Power Transfer (WPT) technology is a novel research area in the charging technology that bridges the utility and the automotive industries. There are various solutions that are currently being evaluated by several research teams to find the most efficient way to manage the power flow from the grid to the vehicle energy storage system. There are different control parameters that can be utilized to compensate for the change in the impedance due to variable parameters such as battery state-of-charge, coupling factor, and coil misalignment. This paper presents the implementation of an active front-end rectifier on the grid side for power factor control and voltage boost capability for load power regulation. The proposed SiC MOSFET based single phase active front end rectifier with PFC resulted in >97% efficiency at 137mm air-gap and >95% efficiency at 160mm air-gap.
Optimal Time-of-Use Management with Power Factor Correction Using Behind-the-Meter Energy Storage Systems.
Abstract not provided.
Control of Dual-Opposed Stirling Convertors with Active Power Factor Correction Controllers
When using recently-developed active power factor correction (APFC) controllers in power systems comprised of dual-opposed free-piston Stirling convertors, a variety of configurations of the convertors and controller(s) can be considered, with configuration ultimately selected based on benefits of efficiency, reliability, and robust operation. The configuration must not only achieve stable control of the two convertors, but also synchronize and regulate motion of the pistons to minimize net dynamic forces. The NASA Glenn Research Center (GRC) System Dynamic Model (SDM) was used to study ten configurations of dual-opposed convertor systems. These configurations considered one controller with the alternators connected in series or in parallel, and two controllers with the alternators not connected (isolated). For the configurations where the alternators were not connected, several different approaches were evaluated to synchronize the two convertors. In addition, two thermodynamic configurations were considered: two convertors with isolated working spaces and convertors with a shared expansion space. Of the ten configurations studied, stable operating modes were found for four. Three of those four had a common expansion space. One stable configuration was found for the dual-opposed convertors with separate working spaces. That configuration required isochronous control of both convertors, and two APFC controllers were used to accomplish this. A frequency/phase control loop was necessary to allow each APFC controller to synchronize its associated convertor with a common frequency.
Control of Dual-Opposed Stirling Convertors with Active Power Factor Correction Controllers
When using recently-developed active power factor correction (APFC) controllers in power systems comprised of dual-opposed free-piston Stirling convertors, a variety of configurations of the convertors and controller(s) can be considered, with configuration ultimately selected based on benefits of efficiency, reliability, and robust operation. The configuration must not only achieve stable control of the two convertors, but also synchronize and regulate motion of the pistons to minimize net dynamic forces. The NASA Glenn Research Center (GRC) System Dynamic Model (SDM) was used to study ten configurations of dual-opposed convertor systems. These configurations considered one controller with the alternators connected in series or in parallel, and two controllers with the alternators not connected (isolated). For the configurations where the alternators were not connected, several different approaches were evaluated to synchronize the two convertors. In addition, two thermodynamic configurations were considered: two convertors with isolated working spaces and convertors with a shared expansion space. Of the ten configurations studied, stable operating modes were found for four. Three of those four had a common expansion space. One stable configuration was found for the dual-opposed convertors with separate working spaces. That configuration required isochronous control of both convertors, and two APFC controllers were used to accomplish this. A frequency/phase control loop was necessary to allow each APFC controller to synchronize its associated convertor with a common frequency.
Optimization, Design, and Demonstration of 1 kW Stirling Controller Using Capacitor-based Power Factor Correction
Free-piston Stirling convertors provide efficient, reliable thermal to electric power conversion, provided they are paired with a reliable controller. This paper outlines work underway on design concepts for kilowatt-class controllers. Using passive power factor correction (PFC) this design explores the possibility of reducing programmatic risk through system simplification. Efficiency is maximized through incorporating wide-bandgap gallium nitride (GaN) switches, and passive PFC volume is minimized through the use of polymer multi-layer capacitors. This work is aimed at exploring new approaches for future Stirling controllers.
Design of 1 kW Simplified Stirling Controller Using Capacitor-Based Power Factor Correction
Free-piston Stirling convertors hold potential for efficient, reliable thermal to electric power conversion, provided they are paired with a robust controller. This paper outlines work underway on a system-level optimization of a kW controller. Using simplified control and passive power factor correction (PFC) this design explores the possibility of reducing programmatic risk through system simplification. Efficiency is improved through incorporating wide-bandgap gallium nitride (GaN) switches, and PFC volume is minimized through the use of polymer multi-layer capacitors. This work is aimed at exploring new approaches for future Stirling space power concepts.
Reliability of IGBT in a STATCOM for Harmonic Compensation and Power Factor Correction
With smart grid integration, there is a need to characterize reliability of a power system by including reliability of power semiconductors in grid related applications. In this paper, the reliability of IGBTs in a STATCOM application is presented for two different applications, power factor correction and harmonic elimination. The STATCOM model is developed in EMTP, and analytical equations for average conduction losses in an IGBT and a diode are derived and compared with experimental data. A commonly used reliability model is used to predict reliability of IGBT.
A Two-Stage Approach for PV Inverter Engagement in Power Factor Correction and Voltage Regulation
The rapid integration of distributed energy resources, like solar photovoltaics (PVs), can lead to overvolt-age challenges due to reverse power flow and a noticeable decrease in power factor at the substation interface. While existing literature extensively explores utilizing smart inverter capabilities for reactive power flexibility using a volt-var curve (VVC), obtaining time-varying operating points of such curves in real-time is challenging due to computational demands and communication requirements. Similarly, employing optimization-based approaches for reactive power control and active voltage regulation in large-scale distribution feeders is difficult due to the complexity of the problem and the challenges in effectively engaging customer-owned resources. This paper proposes a two-stage strategy to harness smart inverters for reactive power support. The first stage formulates short-term planning by optimally designing VVCs (on a daily or hourly basis) for large-scale solar PVs based on projected system needs and communicating optimal curves to smart inverters in advance. Subsequently, the second stage employs a transactive-based method to involve customer-owned PVs for reactive power support, effectively enhancing overall system performance and addressing real-time demands. In conclusion, the efficacy of this approach will be demonstrated using real-world distribution circuits provided by Vermont Electric Power Company (VELCO) and Vermont Electric Cooperative (VEC).
Power Factor Correction in Feeders With Distributed Photovoltaics Using Residential Appliances as Virtual Batteries
Not Available
Optimal Dispatch of Energy Storage Systems for Harmonic Mitigation and Power Factor Correction.
Abstract not provided.
Harmonic Resonance Analysis for PEP-II Power Factor Correction Upgrades
Explore the source record for details and available documents.
Optimal Time-of-Use Management with Power Factor Correction Using Behind-the-Meter Energy Storage Systems.
Abstract not provided.
Optimal Dispatch of Energy Storage Systems for Harmonic Mitigation and Power Factor Correction.