Control of Dual-Opposed Stirling Convertors with Active Power Factor Correction Controllers

When using recently-developed active power factor correction (APFC) controllers in power systems comprised of dual-opposed free-piston Stirling convertors, a variety of configurations of the convertors and controller(s) can be considered, with configuration ultimately selected based on benefits of efficiency, reliability, and robust operation. The configuration must not only achieve stable control of the two convertors, but also synchronize and regulate motion of the pistons to minimize net dynamic forces. The NASA Glenn Research Center (GRC) System Dynamic Model (SDM) was used to study ten configurations of dual-opposed convertor systems. These configurations considered one controller with the alternators connected in series or in parallel, and two controllers with the alternators not connected (isolated). For the configurations where the alternators were not connected, several different approaches were evaluated to synchronize the two convertors. In addition, two thermodynamic configurations were considered: two convertors with isolated working spaces and convertors with a shared expansion space. Of the ten configurations studied, stable operating modes were found for four. Three of those four had a common expansion space. One stable configuration was found for the dual-opposed convertors with separate working spaces. That configuration required isochronous control of both convertors, and two APFC controllers were used to accomplish this. A frequency/phase control loop was necessary to allow each APFC controller to synchronize its associated convertor with a common frequency.

Regan, Timothy F.↗

Control of Dual-Opposed Stirling Convertors with Active Power Factor Correction Controllers

When using recently-developed active power factor correction (APFC) controllers in power systems comprised of dual-opposed free-piston Stirling convertors, a variety of configurations of the convertors and controller(s) can be considered, with configuration ultimately selected based on benefits of efficiency, reliability, and robust operation. The configuration must not only achieve stable control of the two convertors, but also synchronize and regulate motion of the pistons to minimize net dynamic forces. The NASA Glenn Research Center (GRC) System Dynamic Model (SDM) was used to study ten configurations of dual-opposed convertor systems. These configurations considered one controller with the alternators connected in series or in parallel, and two controllers with the alternators not connected (isolated). For the configurations where the alternators were not connected, several different approaches were evaluated to synchronize the two convertors. In addition, two thermodynamic configurations were considered: two convertors with isolated working spaces and convertors with a shared expansion space. Of the ten configurations studied, stable operating modes were found for four. Three of those four had a common expansion space. One stable configuration was found for the dual-opposed convertors with separate working spaces. That configuration required isochronous control of both convertors, and two APFC controllers were used to accomplish this. A frequency/phase control loop was necessary to allow each APFC controller to synchronize its associated convertor with a common frequency.

Regan, Timothy F.↗

Optimization, Design, and Demonstration of 1 kW Stirling Controller Using Capacitor-based Power Factor Correction

Free-piston Stirling convertors provide efficient, reliable thermal to electric power conversion, provided they are paired with a reliable controller. This paper outlines work underway on design concepts for kilowatt-class controllers. Using passive power factor correction (PFC) this design explores the possibility of reducing programmatic risk through system simplification. Efficiency is maximized through incorporating wide-bandgap gallium nitride (GaN) switches, and passive PFC volume is minimized through the use of polymer multi-layer capacitors. This work is aimed at exploring new approaches for future Stirling controllers.

Christopher Barth↗

Design of 1 kW Simplified Stirling Controller Using Capacitor-Based Power Factor Correction

Free-piston Stirling convertors hold potential for efficient, reliable thermal to electric power conversion, provided they are paired with a robust controller. This paper outlines work underway on a system-level optimization of a kW controller. Using simplified control and passive power factor correction (PFC) this design explores the possibility of reducing programmatic risk through system simplification. Efficiency is improved through incorporating wide-bandgap gallium nitride (GaN) switches, and PFC volume is minimized through the use of polymer multi-layer capacitors. This work is aimed at exploring new approaches for future Stirling space power concepts.

Stirling↗

Single Phase Passive Rectification Versus Active Rectification Applied to High Power Stirling Engines

Stirling engine converters are being considered as potential candidates for high power energy conversion systems required by future NASA explorations missions. These types of engines typically contain two major moving parts, the displacer and the piston, in which a linear alternator is attached to the piston to produce a single phase sinusoidal waveform at a specific electric frequency. Since all Stirling engines perform at low electrical frequencies (less or equal to 100 Hz), space explorations missions that will employ these engines will be required to use DC power management and distribution (PMAD) system instead of an AC PMAD system to save on space and weight. Therefore, to supply such DC power an AC to DC converter is connected to the Stirling engine. There are two types of AC to DC converters that can be employed, a passive full bridge diode rectifier and an active switching full bridge rectifier. Due to the inherent line inductance of the Stirling Engine-Linear Alternator (SE-LA), their sinusoidal voltage and current will be phase shifted producing a power factor below 1. In order to keep power the factor close to unity, both AC to DC converters topologies will implement power factor correction. This paper discusses these power factor correction methods as well as their impact on overall mass for exploration applications. Simulation results on both AC to DC converters topologies with power factor correction as a function of output power and SE-LA line inductance impedance are presented and compared.

Santiago, Walter↗

Development of Advanced Stirling Radioisotope Generator for Space Exploration

Under the joint sponsorship of the Department of Energy and NASA, a radioisotope power system utilizing Stirling power conversion technology is being developed for potential future space missions. The higher conversion efficiency of the Stirling cycle compared with that of Radioisotope Thermoelectric Generators (RTGs) used in previous missions (Viking, Pioneer, Voyager, Galileo, Ulysses, Cassini, and New Horizons) offers the advantage of a four-fold reduction in PuO2 fuel, thereby saving cost and reducing radiation exposure to support personnel. With the advancement of state-of-the-art Stirling technology development under the NASA Research Announcement (NRA) project, the Stirling Radioisotope Generator program has evolved to incorporate the advanced Stirling convertor (ASC), provided by Sunpower, into an engineering unit. Due to the reduced envelope and lighter mass of the ASC compared to the previous Stirling convertor, the specific power of the flight generator is projected to increase from 3.5 to 7 We/kg, along with a 25 percent reduction in generator length. Modifications are being made to the ASC design to incorporate features for thermal, mechanical, and electrical integration with the engineering unit. These include the heat collector for hot end interface, cold-side flange for waste heat removal and structural attachment, and piston position sensor for ASC control and power factor correction. A single-fault tolerant, active power factor correction controller is used to synchronize the Stirling convertors, condition the electrical power from AC to DC, and to control the ASCs to maintain operation within temperature and piston stroke limits. Development activities at Sunpower and NASA Glenn Research Center (GRC) are also being conducted on the ASC to demonstrate the capability for long life, high reliability, and flight qualification needed for use in future missions.

Chan, Jack↗

Development of a Low Inductance Linear Alternator for Stirling Power Convertors

The free-piston Stirling power convertor is a promising technology for high efficiency heat-to-electricity power conversion in space. Stirling power convertors typically utilize linear alternators for converting mechanical motion into electricity. The linear alternator is one of the heaviest components of modern Stirling power convertors. In addition, state-of-art Stirling linear alternators usually require the use of tuning capacitors or active power factor correction controllers to maximize convertor output power. The linear alternator to be discussed in this paper, eliminates the need for tuning capacitors and delivers electrical power output in which current is inherently in phase with voltage. No power factor correction is needed. In addition, the linear alternator concept requires very little iron, so core loss has been virtually eliminated. This concept is a unique moving coil design where the magnetic flux path is defined by the magnets themselves. This paper presents computational predictions for two different low inductance alternator configurations, and compares the predictions with experimental data for one of the configurations that has been built and is currently being tested.

Stirling↗

Development of a Low-Inductance Linear Alternator for Stirling Power Convertors

The free-piston Stirling power convertor is a promising technology for high-efficiency heat-to-electricity power conversion in space. Stirling power convertors typically utilize linear alternators for converting mechanical motion into electricity. The linear alternator is one of the heaviest components of modern Stirling power convertors. In addition, state-of-the-art Stirling linear alternators usually require the use of tuning capacitors or active power factor correction controllers to maximize convertor output power. The linear alternator to be discussed in this paper eliminates the need for tuning capacitors and delivers electrical power output in which current is inherently in phase with voltage. No power factor correction is needed. In addition, the linear alternator concept requires very little iron, so core loss has been virtually eliminated. This concept is a unique moving coil design where the magnetic flux path is defined by the magnets themselves. This paper presents computational predictions for two different low inductance alternator configurations. Additionally, one of the configurations was built and tested at GRC, and the experimental data is compared with the predictions.

Stirling↗

Test Results from a Simulated High Voltage Lunar Power Transmission Line

The Alternator Test Unit (ATU) in the Lunar Power System Facility (LPSF) located at the NASA Glenn Research Center (GRC) in Cleveland, OH was modified to simulate high voltage transmission capability. The testbed simulated a 1 km transmission cable length from the ATU to the LPSF using resistors and inductors installed between the distribution transformers. Power factor correction circuitry was used to compensate for the reactance of the distribution system to improve the overall power factor. This test demonstrated that a permanent magnet alternator can successfully provide high frequency AC power to a lunar facility located at a distance.

Birchenough, Arthur↗

Test Results From a Simulated High-Voltage Lunar Power Transmission Line

The Alternator Test Unit (ATU) in the Lunar Power System Facility (LPSF) located at the NASA Glenn Research Center (GRC) in Cleveland, Ohio was modified to simulate high-voltage transmission capability. The testbed simulated a 1 km transmission cable length from the ATU to the LPSF using resistors and inductors installed between the distribution transformers. Power factor correction circuitry was used to compensate for the reactance of the distribution system to improve the overall power factor. This test demonstrated that a permanent magnet alternator can successfully provide high-frequency ac power to a lunar facility located at a distance.

Birchenough, Arthur↗

Advanced Controller for the Free-Piston Stirling Convertor

The free-piston Stirling power convertor is being considered as an advanced power conversion technology to be used for future NASA deep space missions requiring long life radioisotope power systems. This technology has a conversion efficiency of over 25%, which is significantly higher than the efficiency of the Radioisotope Thermal-electric Generators (RTG) now in use. The NASA Glenn Research Center has long been recognized as a leader in Stirling technology and is responsible for the development of advanced technologies that are intended to significantly improve key characteristics of the Stirling convertor. The advanced technologies identified for development also consider the requirements of potential future missions and the new capabilities that have become available in the associated technical areas. One of the key areas identified for technology development is the engine controller. To support this activity, an advanced controller is being developed for the Stirling power convertor. This controller utilizes active power factor correction electronics and microcontroller-based controls. The object of this paper is to present an overview of the advanced controller concept with modeling, simulation and hardware test data.

Gerber, Scott S.↗

Advanced Controller Developed for the Free-Piston Stirling Convertor

A free-piston Stirling power convertor is being considered as an advanced power-conversion technology for future NASA deep-space missions requiring long-life radioisotope power systems. The NASA Glenn Research Center has identified key areas where advanced technologies can enhance the capability of Stirling energy-conversion systems. One of these is power electronic controls. Current power-conversion technology for Glenn-tested Stirling systems consists of an engine-driven linear alternator generating an alternating-current voltage controlled by a tuning-capacitor-based alternating-current peak voltage load controller. The tuning capacitor keeps the internal alternator electromotive force (EMF) in phase with its respective current (i.e., passive power factor correction). The alternator EMF is related to the piston velocity, which must be kept in phase with the alternator current in order to achieve stable operation. This tuning capacitor, which adds volume and mass to the overall Stirling convertor, can be eliminated if the controller can actively drive the magnitude and phase of the alternator current.

Gerber, Scott S.↗

Control circuit maintains unity power factor of reactive load

Circuit including feedback control elements automatically corrects the power factor of a reactive load. It maintains power supply efficiency where negative load reactance changes and varies by providing corrective error signals to the control windings of a power supply transformer.

Kramer, M.↗

A Study on Effect of Tuning Capacitor in Dynamic Radioisotope Power Systems

This study presents the effect of tuning capacitors on the power factor and power output of a gas spring-based free-piston Stirling convertor—Advanced Stirling convertor—when the convertor runs on a forced-oscillation type controller. More specifically, this paper studies how off-nominal tuning capacitance values affects the Stirling convertor in terms of the piston stability and electrical power output, when the convertor is operated by forced-oscillation type controller, such as an alternating current bus controller, and operating conditions of the convertor are unchanged. It has been widely known that tuning capacitors are important circuit components to stabilize the piston amplitude of the free-piston Stirling convertors and correct the power factor for high electrical power output. Recent modeling analysis conducted by NASA Glenn Research Center, however, suggests that while the stability of the convertor is affected by the tuning capacitor value, the power factor and the electrical power output are not affected by the tuning capacitor value, as long as the convertor is controlled by a forced-oscillation controller and the convertor operating conditions, such as the hot-end/cold-end temperatures, piston amplitude, and operating frequency, are unchanged. To verify the modeling analysis results, a test setup is devised where the convertor is controlled by a forced-oscillation controller and the piston amplitude, hot-end temperature, and charge pressure are controlled to 4mm, 760˚C, and 485psig, respectively, while the tuning capacitor value is changed from its nominal value, 840μF to 1040μF and 1240μF. Furthermore, the vibration test results of the same convertor with the three tuning capacitor values are also presented in this paper to show the effect of the tuning capacitor value on the convertor stability. The test results suggest that when the convertor is controlled by a forced-oscillation, the tuning capacitor value determines the convertor stability but not the power factor nor electrical power output. Therefore, the tuning capacitance value in forced-oscillation controllers should be determined based on the convertor stability, system mass, and volume.

Free-Piston Stirling Convertor Controller↗

A Study on Effect of Tuning Capacitor in Dynamic Radioisotope Power Systems

This study presents the effect of the tuning capacitor on stability and electrical power output of a gas-bearing based free-piston Stirling convertor (FPSC) when operating on a fixed-frequency type controller. It has been widely accepted that the tuning capacitor is an important circuit component of the FPSC to stabilize piston amplitude and maximize electrical power output by correcting the power factor. Models suggest the stability of the FPSC is strongly coupled to the tuning capacitance, while the coupling to the electrical power output is weak. This applies to cases where the operating frequency of the FPSC is fixed by a fixed-frequency controller and other operating conditions, such as the hot-end and cold-end temperatures, piston amplitude, and pressure are constant. To verify the modeling analysis results, an Advanced Stirling Convertor (ASC) was controlled by an AC power supply and the piston amplitude, hot-end temperature, cold-end temperature, and pressure are actively controlled to 4.3mm, 760˚C, 40˚C and 485psig, respectively, while the tuning capacitor value was changed from 840μF to 1040μF and 1240μF. Furthermore, the vibration test results of the ASC with different tuning capacitor values are also presented to show the effect of the tuning capacitor on stability. The experimental test results verified that the effect of tuning capacitor on electrical power output is negligible while the effect on stability is rather noticeable. Therefore, the ideal tuning capacitor value should be selected based on required stability of the FPSC.

Free-Piston Stirling Convertor Controller↗

A Study on Effect of Tuning Capacitor in Dynamic Radioisotope Power Systems

This study presents the effect of the tuning capacitor on the stability and electrical power output of a gas spring-based free-piston Stirling convertor (FPSC) when the FPSC runs on a forced-oscillation type controller. It has been widely accepted that the tuning capacitor is an important circuit component of the FPSC to stabilize piston amplitude and maximize electrical power output by correcting the power factor. Recent modeling analysis, however, suggests that while the effect on the stability is significant, the effect on the electrical power output is almost negligible as long as the operating frequency the FPSC is fixed by a forced-oscillation controller and operating conditions, such as the hot-end/cold-end temperatures, piston amplitude, and pressure, are unchanged. To verify the modeling analysis results, Advanced Stirling Convertor (ASC) is controlled by an AC power supply and the piston amplitude, hot-end temperature, cold-end temperature, and pressure are actively controlled to 4.3mm, 760˚C, 40˚C and 485psig, respectively, while the tuning capacitor value is changed from 840μF to 1040μF and 1240μF. Furthermore, the vibration test results of the ASC with the three tuning capacitor values are also presented to show the effect of the tuning capacitor on stability. The test results suggest that when the FPSC operates at a fixed frequency, the effect of tuning capacitor on electrical power output is negligible while the effect on stability is rather significant. Therefore, the tuning capacitor value should be selected toward the highest stability.

Free-Piston Stirling Convertor Controller↗

Performance of Titanium Optics on a NASA 30 Cm Ion Thruster

The results of performance tests with two titanium optics sets are presented and compared to those of molybdenum optics. All tests were conducted on a 30 cm ion thruster that was nearly identical to the NASA Solar Electric Propulsion Technology Application Readiness (NSTAR) thruster design. Optics performance tests were conducted over a thruster input power range of 0.5 to 4.6 kW. Optics performance including impingement-limited total voltages, electron backstreaming limits, screen grid ion transparencies, near-field beam current density profiles, beam divergence angles, and beam divergence thrust correction factors were determined throughout this power range. The impingement-limited total voltages for titanium optics were within 10 to 55 V of those for molybdenum optics. Electron backstreaming limit magnitude as a function of peak beam current density for both molybdenum and titanium optics were within a few volts of each other, indicating similar hot grid gaps for these two grid materials during steady-state operation. Beam divergence half-angles at 90 percent of the total beam current and thrust correction factors for both titanium optics sets were within one degree and one percent, respectively, of those for molybdenum optics. When thruster power was increased to 2.3 kW immediately following discharge ignition, the titanium screen grid came into contact with the accelerator grid within five minutes of ignition. Relative to molybdenum, titanium's larger thermal expansion and smaller thermal conductivity likely caused the screen grid to thermally expand more relative to the accelerator grid during startup.