Search NASA⌕ Search

SEARCH · Search NASA

Results for “power hardware-in-the-loop validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Asynchronous Grid Connections Providing Fast-Frequency Response: System Integration Study

This paper presents an integration study for the recent power electronic-based fast-frequency response technology, "asynchronous grid connection" which operates as an aggregator for behind-the-meter resources and distributed generators. Both technical feasibility and techno-economic viability studies are presented. The fast-frequency response characteristics, validated against Power Hardware-in-the-Loop experiments, are integrated into an IEEE 9- bus system in DigSilent PowerFactory for system-level dynamic analysis. It demonstrates that droop-based control enhancements to local distributed generators allow their aggregation to provide grid-supporting functionalities and participate in the ancillary service markets. To this end, a long-term simulation embedding the system within the ancillary service market framework of PJM has been performed. The fast-frequency response regulation is subsequently used to calculate the potential revenue and project the results on a 15-year investment horizon. Finally, the techno-economic analysis provides recommendations for enhancements to access the full potential of distributed generators on a technical and regulatory level.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Community Resilience Through Rapid Restoration Leveraging Distributed Energy Resources (DERs) and Low-Cost Sensors

Equitable and automated bottoms-up power restoration following an extreme event will be demonstrated at a site in Puerto Rico. To do so, the team will develop enhanced grid situational awareness techniques integrating behind-the-meter (BTM) distributed energy resources (DER) discovery, impedance sweeping based outage boundary detection, and feasible restoration path identification algorithms. Resilience metric will be developed and incorporated along with situational awareness information in a distributed Model Predictive Control (MPC)-based restoration optimization algorithm to control and mobilize grid assets. These algorithms will be validated through power hardware-in-the-loop experiments and ultimately, a site demonstration to show that outage recovery time and total recovered load could be improved by >20% over the baseline.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid Resiliency with a 100% Renewable Microgrid

San Diego Gas & Electric Company (SDG&E) installed America’s first and largest utility-scale microgrid in Borrego Springs in 2013. The first generation Borrego Springs Microgrid utilized diesel generators to form and stabilize the microgrid island, with support from grid-scale batteries and local solar photovoltaic (PV) generation. In this project, SDG&E in partnership with National Renewable Energy Laboratory (NREL) demonstrated through modeling, simulation and utility field testing that blackstart and islanding of the microgrid can be led with 100% renewable, inverter based resources (IBRs), to help reduce community reliance on conventional generation resources. Through equipment upgrades, grid-forming island leader capability was transitioned to a battery IBR instead of the Borrego Springs Microgrid diesel generators. A new microgrid controller was integrated to the microgrid and programmed to control and manage multiple energy storage systems. Synchrophasor and other power quality data verified autonomous, high-speed response of the IBRs through blackstart, islanding, and load step testing. Results of project field evaluations provide distribution systems operators (DSO) with increased confidence that renewable, IBR can replace traditional generators to blackstart and island microgrids and rapidly establish stable island frequency with rapid changes in peak power demand. Importantly, the project validated the integration feasibility of a distributed energy resource management system (DERMS) controller that manages multiple grid-forming and grid-following IBRs, establishing a standard design interface to reduce the complexity of integrating new DERs in the future and supporting replication by the industry. As a result of learnings in this project, SDG&E has implemented the microgrid controller strategy at multiple other microgrid sites, thereby validating the replicability of the solution. Hardware-in-the-loop (HIL) simulations including power and controller HIL hardware — along with electromagnetic transient (EMT) simulations of Borrego Springs Microgrid —informed adjustments to inverter parameters and were important to characterize the performance of the IBRs in relevant operating conditions before deployment. The EMT and HIL simulations of islanding the entire community are important contributions in providing confidence in IBR performance prior to future islanding of the community in the field. High-fidelity EMT and/or HIL simulation of IBRs can de-risk field operations, and its relevance and importance as a tool is increasing as distribution grids and microgrids become more complex and dynamic with an increasing proportion of renewable generation, distributed energy storage, and two-way power and energy flows.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hybrid Dynamic Modeling of Smart Inverter

This letter proposes a novel hybrid method for assessing grid-connected three-phase converter interfaced resources (CIR) dynamics with the IEEE standard 1547-2018 grid support functions (GSFs), which blends physics and data-driven techniques. First, the letter derives an analytical model of a CIR to represent the internal physics and data-driven model (DDM) using a system identification algorithm to represent the rest of the dynamics, including the GSF. The derived hybrid model combines the analytical model of CIR and DDM, which balances accuracy and flexibility and is compared with the detailed switched model. Furthermore, the efficacy of the proposed approach to represent the advanced CIR dynamics is substantiated by power hardware-in-the-loop experiment data where real measurements from a commercial CIR are used to cross-validate the proposed approach. Furthermore, the results indicate that despite simple, the hybrid model accurately reproduces the dynamics of the detailed CIR model with an acceptable accuracy.

Data-driven model↗

Enhancing EV Charging Station Resilience with Multifunctional Converter Leg Integration

In this paper, a multifunctional converter leg is integrated into an EV charger’s power circuit to enhance EV charging station resilience under power electronics converter device faults and grid outages. In the event of a device fault, it substitutes the failed converter leg, maintaining operation. During a grid outage, it assists the system as a fourth leg to the front-end converter, enabling grid-forming capability to supply power to the charging station critical loads while allowing limited power vehicle charging. The proposed approach’s effectiveness under both front-end power converter device faults and grid outage scenarios are validated through simulation and controller hardware-in-the-loop results.

Pereira Pinto, Joao [ORNL]↗

EUREICA: Efficient UltRa Endpoint IoT-enabled Coordinated Architecture

The electricity grid has evolved from a physical system to a cyber-physical system with digital devices that perform measurement, control, communication, computation, and actuation. The increased penetration of distributed energy resources (DERs) that include renewable generation, flexible loads, and storage provides extraordinary opportunities for improvements in efficiency and sustainability. However, they can introduce new vulnerabilities in the form of cyberattacks, which can cause significant challenges in ensuring grid resilience. The purpose of this project was to develop a framework ((Efficient, Ultra-REsilient, IoT-Coordinated Assets, or EUREICA)for achieving grid resilience through suitably coordinated assets including a network of Internet of Things (IoT) devices, and a local electricity market (LEM) to identify trustable assets and carry out this coordination. Situational Awareness (SA) of locally available DERs with the ability to inject power or reduce consumption is enabled by the market, together with a monitoring procedure for their trustability and commitment. Experiments conducted during this project demonstrated that, with this SA, a variety of cyberattacks can be mitigated using local trustable resources without stressing the bulk grid. The demonstrations were carried out using a variety of high-fidelity co-simulation platforms, real-time hardware-in-the-loop validation, and a utility-friendly simulator.

14 SOLAR ENERGY↗

SDN-Based Smart Cyber Switching (SCS) for Cyber Restoration of a Digital Substation

In recent years, critical infrastructure and power grids have increasingly been targets of cyber-attacks, causing widespread and extended blackouts. Digital substations are particularly vulnerable to such cyber incursions, jeopardizing grid stability. This paper addresses these risks by proposing a cybersecurity framework that leverages software-defined networking (SDN) to bolster the resilience of substations based on the IEC- 61850 standard. The research introduces a strategy involving smart cyber switching (SCS) for mitigation and concurrent intelligent electronic device (CIED) for restoration, ensuring ongoing operational integrity and cybersecurity within a substation. The SCS framework improves the physical network’s behavior (i.e., leveraging commercial SDN capabilities) by incorporating an adaptive port controller (APC) module for dynamic port management and an intrusion detection system (IDS) to detect and counteract malicious IEC-61850-based sampled value (SV) and generic object-oriented system event (GOOSE) messages within the substation’s communication network. The framework’s effectiveness is validated through comprehensive simulations and a hardware-in-the-loop (HIL) testbed, demonstrating its ability to sustain substation operations during cyber-attacks and significantly improve the overall resilience of the power grid.

Liu, Chen-Ching (ORCID:0000000289417958)↗

Improving EV Charger Resiliency for MW Charging Systems

In this paper, the resiliency of a megawatt-scale EV charging station is investigated. Fault detection and tolerance methodologies are presented, based on monitoring the voltage offsets in DABs and switch-level currents in three-phase inverters, with the goal of maintaining operation at rated power during single faults and at reduced power under multiple fault conditions. To validate the effectiveness of the proposed strategy, simulation results at the rated 1 MW power of the charging station are carried out, followed by controller hardware-in-the-loop (CHIL) experiments on a 250 kW section of the station. The results highlight the feasibility of the integrated fault-tolerant methods for resilient, high-power EV charging infrastructure.

Adib, Aswad [ORNL] (ORCID:000000020997056X)↗

Secure Time Synchronization in Power Grids and Network HIL Synchrophasor Testing

Reliable and secure time synchronization underpins the monitoring and control functions of modern power grids. As GPS-based timing infrastructures grow more susceptible to spoofing and jamming, their vulnerabilities pose escalating risks to grid stability. This work investigates a secure, resilient timing framework that can serve as an alternative or redundant source for power grids, with a particular focus on synchrophasorbased applications. A candidate timing system architecture is evaluated to guarantee trustworthy time dissemination, even in degraded conditions. A network hardware-in-the-loop testing of two synchrophasors validates the concepts, demonstrating enhanced timing integrity, improved detection of timing anomalies, and sustained observability during adverse timing events.

Wu, Ori [ORNL] (ORCID:0000000326723410)↗

Energy Systems Integration Facility Stewardship Summary: Fiscal Year 2025

A summary of NLR's stewardship of the nationally unique Energy Systems Integration Facility (ESIF) highlighting performance metrics, capability upgrades, and examples of R&D impact. 2025 brought a national focus on energy and ESIF is meeting the moment. All eyes are on data centers and domestic manufacturing and bringing the benefits of artificial intelligence to power system planning and operations. In step with national priorities, ESIF is building out capabilities that advance secure, reliable, and affordable power. ESIF hosted 190 multidisciplinary research projects, 855 high-performance computer users, and collaborated with 81 partners from industry, academia, research, and federal agencies. These research projects resulted in an AI method for detecting high-impedance faults with 90% accuracy, a grid controls demonstration in Connecticut, power quality validation of CorePower's flagship inductor, and a cybersecurity assessment of potential rogue capabilities in digitally connected energy devices. Facility infrastructure improvements enhanced the thermal research network, the SCADA system, the cyber range, power hardware-in-the-loop testing, and more. With support from the U.S Department of Energy (DOE), the ESIF laboratories continue to deliver leading solutions for secure, reliable, and affordable power.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Virtual Self-Excited Induction Generator-Based Grid-Forming Inverter Control for Robust Voltage Regulation Under Nonideal Loading

This paper presents a generator-inspired control methodology for grid-forming (GFM) inverters that deliberately emulates a self-excited induction generator so that the inverter can hold its voltage and frequency under difficult loading and severe terminal disturbances across wide voltage and frequency ranges. The design integrates a Lyapunov energy function-based inner loop to provide high bandwidth and strong disturbance rejection, and it complements this with a passivity-based argument that furnishes a coherent large-signal stability guarantee beyond small-signal limits. Analytical insights are developed via the Krylov-Bogoliubov-Mitropolsky averaging method, which reveals an intrinsic resistive droop characteristic; these closed-form relations both explain the observed dynamics and yield simple, decentralized tuning rules. The methodology is validated on a controller-hardware-in-the-loop platform and exercised in real time across balanced, unbalanced, and nonlinear loads, as well as during parallel operation. Across these scenarios, the inverter maintains balanced three-phase voltages, limits harmonic content, settles quickly with well-damped transients, and remains resilient when multiple units operate in parallel. The contributions are a self-excited-machine-inspired GFM controller with enhanced dynamic performance and robustness, a single stability rationale grounded in passivity, closed-form expressions that guide tuning, and comprehensive hardware-in-the-loop validations demonstrating effectiveness and superiority under challenging operating conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hydrogen Production System Scaling Using a High-Fidelity Simulation-Optimization Framework

Proton exchange membrane (PEM) electrolyzers are widely used for hydrogen production, yet few validated, high-fidelity tools can reliably guide scale-up. Using measured performance from a 50-hour hardware-in-the-loop pilot test, a physics-based, plant-level model of a 1.25 MW PEM electrolyzer and its balance-of-plant (BoP) subsystems is developed and validated. The model couples electrochemistry and thermal/flow submodels and is calibrated against pilot test data via a genetic algorithm (GA) workflow. Validation yields a mean absolute percentage error (APE) of 0.43% for cell voltage and stack power. Two scale-out strategies are then benchmarked under a common 7-day wind-and-photovoltaic (PV) profile: (i) linear duplication of 1.25 MW blocks and (ii) shared-BoP architectures. Sharing BoP between stacks reduces BoP energy by 27% at 10 MW and 34% at 100 MW (vs. linear duplication) and improves system specific energy consumption (SEC) to 52.9 and 52.6 kWh/kg, respectively (from 54.0 kWh/kg with linear duplication). Partial-load studies (25-100% set-point) show that cumulative hydrogen production remains nearly constant down to 50% load because all cases use the same weekly renewable-energy input. Below 50%, the power cap limits how much energy can be used within 168 h, which reduces hydrogen output. The model further indicates that the practical operating optimum lies between 50% and 85% load, where efficiency gains begin to appear without significant loss in hydrogen output. Moreover, the efficiency gains at lower loads are offset by reduced production. The validated framework supports scenario-based engineering trade-off studies for large configurations (10-100 MW) and for operating policies under variable renewables.

08 HYDROGEN↗

Demonstration of Grid Services Using Mixed Grid-Forming and Grid-Following Technologies at the Wheatridge Renewable Energy Facility (Final Technical Report)

This Final Technical Report summarizes the analytical, modeling, and engineering work performed to evaluate grid-forming (GFM) inverter capabilities within a large hybrid renewable energy facility. The project focused on assessing the ability of advanced inverter-based resources to provide essential reliability services through coordinated operation of grid-forming (GFM) and grid-following (GFL) technologies. During Budget Period 1, the project developed a comprehensive framework of GFM performance metrics, including angle support, voltage regulation, frequency response, damping behavior, and current-limiting performance. Extensive electromagnetic transient (EMT) studies and hardware-in-the-loop (HIL) testing were conducted to validate GFM behavior under a range of operating conditions, including weak-grid scenarios, voltage disturbances, and multi-resource interactions. The project also established validated modeling approaches, plant-level control integration strategies, commissioning frameworks, and high-speed measurement infrastructure to support future field demonstration. Although the project concluded prior to field demonstration, the results provide a utility-scale foundation for evaluating, modeling, and deploying grid-forming technologies. The methodologies and tools developed contribute to industry understanding of inverter-based resource behavior and support future power system reliability under increasing renewable penetration.

14 SOLAR ENERGY↗

A Real-Time Implementation and Validation of Federated Learning for Grid Services

Grid-edge devices are becoming increasingly important in the energy transition. Preserving privacy was not previously considered an important aspect for power grid operations, but with the increased proliferation of customer-owned assets, it is now an essential consideration. Several mechanisms have been proposed to provide privacy for non-utility owned assets in the power grid. Federated learning (FL) is one method gaining prominence in this area. Although FL has been used for other applications, such as auto-complete in phones, there has not been much investigation into whether these approaches are feasible for grid applications. In this work, we use a research platform with real-time simulators and hardware-in-the-loop capabilities to investigate how FL can be applied to grid-edge devices, and we present the potential grid services that can be derived for these devices. We discuss the computational challenges with deploying complex FL approaches, and we explore several grid services, including participation in retail electricity markets, voltage control, and resilience-driven reconfiguration.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Novel Protection Scheme for Unbalanced Faults in Inverter Dominated Networks: A Computationally Efficient Algorithm for Entry-Level Relays

Microgrids are now a common practice in distribution systems to increase resilience and reliability. However, microgrid protection remains a critical challenge, considering its requirement to operate in both grid connected and islanded, and the variability in fault characteristics under each mode of operation. This paper presents unbalanced power (S unb ) based fault detection algorithm, which considers local voltage and current unbalances to determine faults in the system. S unb is a computationally efficient fault detection algorithm that is suitable for implementation in the programmable logic of entry level protective relays. In addition, the difference in current and voltage unbalance (D n ) is used to determine the fault type. The proposed method demonstrates high sensitivity and selectivity for line-to-ground (LG), line-to-line (LL), and double line-to-ground (LLG) faults, representing the most common faults in distribution systems. It also allows relay coordination with upstream and downstream protection devices in both island and grid connected operation, while preserving grading margins. The same pickup and time multiplier settings of a particular relay for both modes of operation eliminates the need for adaptive settings, which rely on communication networks. Validation was performed with a hardware-in-the-loop (HIL) setup using Typhoon HIL real time simulator interfaced with three entry-level, SEL 751 relays. Results confirmed the algorithm’s ability to discriminate fault conditions, and determine the fault type under both operating modes, maintain fast detection times, and ensure proper protection coordination.

fault classification↗

Cybersecurity Enhancement in Digital Substations: Hidden Markov Model-Based Smart Cyber Switching and Threat Response

The rising incidence of cyber-attacks on critical infrastructure and power grids poses significant threats to the stability and reliability of electrical substations, with potentially devastating consequences such as extended blackouts. This paper introduces an advanced cybersecurity framework aimed at safeguarding IEC 61850-based substations through the integration of software-defined networking (SDN) and digital twin (DT) technologies. The proposed DT-based framework employs smart cyber switching (SCS) for proactive threat mitigation and concurrent intelligent electronic device (CIED) for swift system restoration, thereby maintaining continuous operational integrity and robust cybersecurity defenses. Central to this framework is the adaptive port controller (APC), which enables dynamic port management to adapt to evolving threats, and an intrusion detection system (IDS) designed to detect and neutralize malicious attacks on IEC 61850-based sampled value (SV) and generic object-oriented substation event (GOOSE) messages within the substation’s communication network. Further, novel predictive intrusion detection and response (PIDR) algorithm is implemented on a digital substation (DS) to predict the best route to be taken by the attacker. The efficacy of these comprehensive cybersecurity frameworks is validated through rigorous simulations and a hardware-in-the-loop (HIL) testbed, showcasing the system’s ability to sustain substation operations amidst cyber-attacks.

Digital substation↗

SuperLab 2.0 Showcase: Connecting Five Labs to Tackle Grid Complexity and Unlock Unique Grid Asset Potential

SuperLab 2.0 (a five-lab demonstration) is a collaborative, national-scale experiment showcasing the coordination of geographically distributed energy assets in real time. The demonstration integrates 25 physical and digital assets, spanning wind, photovoltaics, batteries, electrolyzers, DC fast chargers, microgrid controllers, building automation systems, small modular reactors, control centers, and gas turbines, across five U.S. Department of Energy (DOE) national laboratories: National Laboratory of the Rockies (NLR), Idaho National Laboratory, National Energy Technology Laboratory, Lawrence Berkeley National Laboratory, and Sandia National Laboratories. These assets are unified using Energy Sciences Network (ESnet), a low-latency, high-performance DOE network, and are controlled via a centralized energy controller hosted at NLR's Advanced Research on Integrated Energy Systems facility. The demonstration validates the ability to stress-test hybrid energy systems under dynamic scenarios to de-risk advanced control strategies for greater resilience and flexibility.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Balance of Plant Modeling and Real-Time Hardware-in-the-Loop Integration with the Microreactor Automated Control System

The advent of novel microreactor technology has driven a focused effort to explore safety and efficiency improvements that can be achieved through the use of automated system control. Development of control strategies, especially for initial demonstration, requires an adequate surrogate environment to safely research failure modes and control integration with realistic hardware delay. However, efficiency gains from control strategies are improved when the scope of controller action is expanded to include system-level dynamics such as downstream heat extraction and mass flow. For this reason, a balance-of-plant (BOP) model of a representative microreactor system has been developed using the TRANsient Simulation Framework of Reconfigurable Models library in Modelica. This model captures a reactor and primary NaK coolant loop that represent corresponding system components of the Microreactor Applications Research Validation and EvaLuation (MARVEL) design as well as a secondary coolant loop and heat extraction representative of the Microreactor Agile Non-Nuclear Experimental Test Bed (MAGNET). This model configuration allows for hardware-in-the-loop (HIL) integration with microreactor automated control system (MACS) hardware in real time through a Python-based gRPC client. Real-time simulation of model performance with emulated hardware and communication delay suggests that under independent proportional-integral-derivative control of BOP model drum dynamics and downstream heat extraction, stable power load following is achievable. A slight delay in load following, filtering of high-frequency dynamics, and localized temperature fluctation suggest room for improvement through the development of higher-level control strategies. The simulated coupling of the MAGNET facility lays the groundwork for future digital twin analysis with a coupled MACS-MAGNET HIL demonstration.

McConnell, Jono [ORNL] (ORCID:0000000238984741)↗