Search NASA⌕ Search

SEARCH · Search NASA

Results for “power mismatch estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A Fast Load Control System Based on Mobile Distribution-Level Phasor Measurement Unit

The increase of renewable penetration in power grids calls for loads to participate in frequency regulation to avoid under-frequency load shedding after large resource contingencies. The motivation of our work is to fulfill a fast residential load control for frequency stability enhancement. For this purpose, a novel Mobile Distribution-level Phasor Measurement Unit (MDPMU) is developed for disturbance event detection, power mismatch estimation and fast load control. First, the systematic design of the MDPMU introduced. The proposed MDPMU has the major advantages of low cost and high frequency measurement accuracy. Second, the distribution-level measurement is utilized for the Rate Of Change Of Frequency (ROCOF) calculation. Upon detection of a power system frequency event, power mismatch is estimated at the early stage of the event. Details of a robust approach to calculate ROCOF and determine the event starting point are presented. Practical issues including the measurement reporting rate and estimation time are also examined. Finally, with the proposed control system, residential load responses can be controlled coordinately based on load availability and compensation prices offered by customers, providing adaptive frequency regulation service after large resource contingencies. The accuracy of frequency measurement and power mismatch estimation are evaluated via experimental analysis. The frequency stability improvement by load control is validated via PSS/E simulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Estimating and parameterizing mismatch power loss in bifacial photovoltaic systems

Nonuniform irradiance on the rear side of bifacial photovoltaic (PV) systems can cause additional mismatch loss, which may not be appropriately captured in PV energy production estimates and software. We evaluated several scenarios including horizontal single-axis tracking (HSAT) over natural ground-cover and rooftop-mounted systems over high albedo reflective roofs. We found mismatch losses of up to 1.5% annual loss for very close-mounted (0.15 m) rooftop systems, but losses for HSAT systems and high-ground-clearance rooftop systems were lower (<0.5%). A simplified empirical relationship was found that links the spatial variation of irradiance (specifically, the mean absolute difference of irradiance) to the resulting mismatch loss factor, with an R 2 better than .99. Furthermore, this approximate relationship was experimentally validated on mismatched PV modules, and it provides a basis for rapidly estimating bifacial mismatch loss factors for use in hourly PV performance simulations such as PVSyst or SAM. Additional parameters investigated include (a) climate dependence and module orientation, which were not found to have a strong impact on bifacial mismatch losses and (b) PV module fill factor and bifaciality ratio, which did have a strong linear impact on mismatch losses.

14 SOLAR ENERGY↗

A Practical Approach to Inertia Assessment: Analyzing New York's Grid Response to Real Events

The non-uniform distribution of inverter-based resources (IBRs) such as solar and wind energy leads to the formation of weakly coupled regions within the broader interconnection. This highlights the urgency of investigating regional dynamics. This paper proposes a practical framework for estimating regional inertia using actual event measurements from the New York (NY) region. The regional frequency is determined using measurement data from frequency disturbance recorders (FDRs) deployed across NY. The rate-of-change of frequency (RoCoF) is estimated using a hybrid methodology that combines the benefits of both moving and non-moving window techniques. By utilizing the power mismatch value and the estimated RoCoF, various inertia metrics such as regional RoCoF, inertia arrival time, and inertia percentage relative to the interconnection inertia are calculated. The identified confirmed-events that took place between 2017–2022 in NY are used in the study. This assessment of inertia using real event data reveals the true behavior of the grid under stress. The results indicate that as the generation mix in NY evolves with the rise of IBRs, both the RoCoF levels and the regional inertia undergo significant changes.

Dulal, Saurav [University of Tennessee, Knoxville ↗

Statistical Approach for Determining the Sandia Array Performance Model Coefficients that Considers String-Level Mismatch

Commonly used performance models, such as PVsyst, Sandia Array Performance Model (SAPM), and PV LIB, treat the PV array as being constructed of identical modules. Each of the models attempts to account for mismatch losses by applying a simple percent reduction factor to the overall estimated power. The present work attempted to reduce uncertainty of mismatch losses by determining a representative set of performance coefficients for the SAPM that were developed from a characterization of a sample of modules. This approach was compared with current practice, where only a single module’s thermal and electrical properties are testing. However, the results indicate that minimal to no improvements in model predictions were achieved.

47 OTHER INSTRUMENTATION↗

Enhancing workload assessments for validation activities associated with DBA and BDBA scenarios - 165

After the Fukushima Daiichi accident, nuclear regulators around the world have required that power reactor licensees develop more extensive emergency mitigating responses and severe accident management provisions beyond the defense-in-depth measures for design basis accidents (DBAs), previously in place. Workload assessments represent common validation techniques that are used to demonstrate that workers are able to perform tasks without unacceptable performance degradation. High workload is known to induced stress and fatigue and may severely diminish a worker's capacity to perceive, recognize, and respond appropriately during emergency or unanticipated events, which may result in undesirable consequences. In estimating workload during emergency and severe accident scenarios, power reactor licensees tend to rely on subjective measures of workload, such as NASA-TLX. Due to reported mismatches in the literature between subjective and physiologically-derived estimates of workload, it is prudent to see what more can be done to improve the current state of practice, in the context of emergency and severe accident conditions. To improve confidence in workload estimates, it is advocated that the nuclear industry integrate physiological-based measures into current practices by making use of 'on-body' or 'wearable' physiological sensors. In this paper, an overview of three different types of empirical workload approaches is provided. The advantages of wearable physiological sensors are considered in the context of extreme environments and occupations, with tangible examples including heat stress and pupillometry. Suggestions for a consensus forum on workload are provided and a research plan directed at improving the current practice of workload estimation is offered for consideration. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Inertia Estimation and Trend Analysis of the United States Power Grid Interconnections

The transition from conventional to modern power systems is causing an increase in integration of inverter-based resources (IBRs). This generally leads to a decrease in total system inertia, which in-turn increases the system’s rate-of-change-of-frequency (RoCoF) during disturbances. This poses a threat to the frequency stability of the system and may falsely trigger protective devices. To monitor system status and plan for integrating renewable energy sources like photovoltaic, wind, and energy storage systems, a realistic study of inertia estimation and analysis in the United States (US) over the past decade is needed. This paper uses field-measured phasor measurement unit (PMU) data collected throughout the US from 2013 to 2023 via the Frequency Monitoring Network (FNET/GridEye) operated by the University of Tennessee, Knoxville (UTK) and Oak Ridge National Laboratory (ORNL). The collected PMU frequency data is utilized to estimate the system inertia of the three US interconnections: Eastern, Western, and Texas. Various RoCoF time windows are investigated for estimating the inertia of each interconnection by maximizing the correlation coefficient between the measured RoCoF and power mismatch. The resulting inertia trends over the past decade show approximately a 6% decline in inertia in the Eastern interconnection, a 15% decline in inertia in the Western interconnection, and a 16% increase in inertia in Texas. Key insights into how inertia is changing amidst the complex energy landscape are extracted using the fuel mix trend data. This provides valuable information for future energy strategies and planning.

30 DIRECT ENERGY CONVERSION↗

InGaAs concentrator cells for laser power converters and tandem cells

In(0.53)Ga(0.47)As N-on-P concentrator cells were made as part of an effort to develop 1.315 micron laser power converters. The 1.315 micron laser power conversion efficiency was estimated as 29.4 percent (at 5.57 W/cm(sup 2)) based on an 86 percent measured external quantum efficiency at 1.315 microns, and a measured open circuit voltage (484 mV), and fill-factor (67 percent) at the equivalent AM0 short-circuit photocurrent (5.07 A/cm(sup 2)). A 13.5 percent percent AMO efficiency was achieved at 89 suns and 25 C. Measured one-sun and 100-sun AMO efficiency, log I-V analysis, and quantum efficiency are presented for InGaAs cells with and without InP windows to passivate the front surface. Windowed cells performed better at concentration than windowless cells. Lattice mismatch between InGaAs epilayers and InP substrate was less than 800 ppm. Theoretical efficiency is estimated for 1.315 microns laser power converters versus the bandgap energy. Adding aluminum to InGaAs to form In(x)Al(y)Ga(1-x-y)As is presented as a way to achieve an optimal bandgap for 1.315 microns laser power conversion.

Wojtczuk, S.↗

Photovoltaic System Modeling: Uncertainty and Sensitivity Analyses

We report an uncertainty and sensitivity analysis for modeling AC energy from photovoltaic systems. Output from a PV system is predicted by a sequence of models. We quantify uncertainty in the output of each model using empirical distributions of each model’s residuals. We propagate uncertainty through the sequence of models by sampling these distributions to obtain an empirical distribution of a PV system’s output. We consider models that: (1) translate measured global horizontal, direct and global diffuse irradiance to plane-of-array irradiance; (2) estimate effective irradiance; (3) predict cell temperature; (4) estimate DC voltage, current and power; (5) reduce DC power for losses due to inefficient maximum power point tracking or mismatch among modules; and (6) convert DC to AC power. Our analysis considers a notional PV system comprising an array of FirstSolar FS-387 modules and a 250 kW AC inverter; we use measured irradiance and weather at Albuquerque, NM. We found the uncertainty in PV system output to be relatively small, on the order of 1% for daily energy. We found that uncertainty in the models for POA irradiance and effective irradiance to be the dominant contributors to uncertainty in predicted daily energy. Our analysis indicates that efforts to reduce the uncertainty in PV system output predictions may yield the greatest improvements by focusing on the POA and effective irradiance models.

14 SOLAR ENERGY↗

The Simons Observatory: impact of bandpass, polarization angle and calibration uncertainties on small-scale power spectrum analysis

We study the effects due to mismatches in passbands, polarization angles, and temperature and polarization calibrations in the context of the upcoming cosmic microwave background experiment Simons Observatory (SO). Using the SO multi-frequency likelihood, we estimate the bias and the degradation of constraining power in cosmological and astrophysical foreground parameters assuming different levels of knowledge of the instrumental effects. We find that incorrect but reasonable assumptions about the values ofall the systematics examined here can have significant effects on cosmologicalanalyses, hence requiring marginalization approaches at the likelihood level.When doing so, we find that the most relevant effect is due to bandpass shifts. When marginalizing over them, the posteriors of parameters describing astrophysical microwave foregrounds (such as radio point sources or dust) get degraded, while cosmological parameters constraints are not significantly affected.Marginalization over polarization angles with up to 0.25$^{°}$ uncertainty causes an irrelevant bias ≲ 0.05 σ in all parameters.Marginalization over calibration factors in polarization broadens the constraints on the effective number of relativistic degrees of freedom N$_{eff}$ by a factor 1.2, interpreted here as a proxy parameter for non standard model physics targeted by high-resolution CMB measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Planar doped barrier subharmonic mixers

The Planar Doped Barrier (PDB) diode is a device consisting of a p(+) doping spike between two intrinsic layers and n(+) ohmic contacts. This device has the advantages of controllable barrier height, diode capacitance and forward to reverse current ratio. A symmetrically designed PDB has an anti-symmetric current vs. voltage characteristic and is ideal for use as millimeter wave subharmonic mixers. We have fabricated such devices with barrier heights of 0.3, 0.5 and 0.7 volts from GaAs and InGaAs using a multijunction honeycomb structure with junction diameters between one and ten microns. Initial RF measurements are encouraging. The 0.7 volt barrier height 4 micron GaAs devices were tested as subharmonic mixers at 202 GHz with an IF frequency of 1 GHz and had 18 dB of conversion loss. The estimated mismatch loss was 7 dB and was due to higher diode capacitance. The LO frequency was 100.5 GHz and the pump power was 8 mW.

Lee, T. H.↗

Monodromy relations from twisted homology

We reformulate the monodromy relations of open-string scattering amplitudes as boundary terms of twisted homologies on the configuration spaces of Riemann surfaces of arbitrary genus. This allows us to write explicit linear relations involving loop integrands of open-string theories for any number of external particles and, for the first time, to arbitrary genus. In the non-planar sector, these relations contain seemingly unphysical contributions, which we argue clarify mismatches in previous literature. The text is mostly self-contained and presents a concise introduction to twisted homologies. As a result of this powerful formulation, we can propose estimates on the number of independent loop integrands based on Euler characteristics of the relevant configuration spaces, leading to a higher-genus generalization of the famous (n - 3)! result at genus zero.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Model Calibration of Exciter and PSS Using Extended Kalman Filter

Power system modeling and controls continue to become more complex with the advent of smart grid technologies and large-scale deployment of renewable energy resources. As demonstrated in recent studies, inaccurate system models could lead to large-scale blackouts, thereby motivating the need for model calibration. Current methods of model calibration rely on manual tuning based on engineering experience, are time consuming and could yield inaccurate parameter estimates. In this paper, the Extended Kalman Filter (EKF) is used as a tool to calibrate exciter and Power System Stabilizer (PSS) models of a particular type of machine in the Western Electricity Coordinating Council (WECC). The EKF-based parameter estimation is a recursive prediction-correction process which uses the mismatch between simulation and measurement to adjust the model parameters at every time step. Numerical simulations using actual field test data demonstrate the effectiveness of the proposed approach in calibrating the parameters.

Kalsi, Karanjit↗

Planck 2015 results: IX. Diffuse component separation: CMB maps

In this paper, we present foreground-reduced cosmic microwave background (CMB) maps derived from the full Planck data set in both temperature and polarization. Compared to the corresponding Planck 2013 temperature sky maps, the total data volume is larger by a factor of 3.2 for frequencies between 30 and 70 GHz, and by 1.9 for frequencies between 100 and 857 GHz. In addition, systematic errors in the forms of temperature-to-polarization leakage, analogue-to-digital conversion uncertainties, and very long time constant errors have been dramatically reduced, to the extent that the cosmological polarization signal may now be robustly recovered on angular scales ℓ ≳ 40. On the very largest scales, instrumental systematic residuals are still non-negligible compared to the expected cosmological signal, and modes with ℓ< 20 are accordingly suppressed in the current polarization maps by high-pass filtering. As in 2013, four different CMB component separation algorithms are applied to these observations, providing a measure of stability with respect to algorithmic and modelling choices. Additionally, the resulting polarization maps have rms instrumental noise ranging between 0.21 and 0.27μK averaged over 55' pixels, and between 4.5 and 6.1μK averaged over 3$'\atop{.}$4 pixels. The cosmological parameters derived from the analysis of temperature power spectra are in agreement at the 1σ level with the Planck 2015 likelihood. Unresolved mismatches between the noise properties of the data and simulations prevent a satisfactory description of the higher-order statistical properties of the polarization maps. Thus, the primary applications of these polarization maps are those that do not require massive simulations for accurate estimation of uncertainties, for instance estimation of cross-spectra and cross-correlations, or stacking analyses. However, the amplitude of primordial non-Gaussianity is consistent with zero within 2σ for all local, equilateral, and orthogonal configurations of the bispectrum, including for polarization E-modes. Moreover, excellent agreement is found regarding the lensing B-mode power spectrum, both internally among the various component separation codes and with the best-fit Planck 2015 Λ cold dark matter model.

79 ASTRONOMY AND ASTROPHYSICS↗

Hand-Eye Calibration of Robonaut

NASA's Human Space Flight program depends heavily on Extra-Vehicular Activities (EVA's) performed by human astronauts. EVA is a high risk environment that requires extensive training and ground support. In collaboration with the Defense Advanced Research Projects Agency (DARPA), NASA is conducting a ground development project to produce a robotic astronaut's assistant, called Robonaut, that could help reduce human EVA time and workload. The project described in this paper designed and implemented a hand-eye calibration scheme for Robonaut, Unit A. The intent of this calibration scheme is to improve hand-eye coordination of the robot. The basic approach is to use kinematic and stereo vision measurements, namely the joint angles self-reported by the right arm and 3-D positions of a calibration fixture as measured by vision, to estimate the transformation from Robonaut's base coordinate system to its hand coordinate system and to its vision coordinate system. Two methods of gathering data sets have been developed, along with software to support each. In the first, the system observes the robotic arm and neck angles as the robot is operated under external control, and measures the 3-D position of a calibration fixture using Robonaut's stereo cameras, and logs these data. In the second, the system drives the arm and neck through a set of pre-recorded configurations, and data are again logged. Two variants of the calibration scheme have been developed. The full calibration scheme is a batch procedure that estimates all relevant kinematic parameters of the arm and neck of the robot The daily calibration scheme estimates only joint offsets for each rotational joint on the arm and neck, which are assumed to change from day to day. The schemes have been designed to be automatic and easy to use so that the robot can be fully recalibrated when needed such as after repair, upgrade, etc, and can be partially recalibrated after each power cycle. The scheme has been implemented on Robonaut Unit A and has been shown to reduce mismatch between kinematically derived positions and visually derived positions from a mean of 13.75cm using the previous calibration to means of 1.85cm using a full calibration and 2.02cm using a suboptimal but faster daily calibration. This improved calibration has already enabled the robot to more accurately reach for and grasp objects that it sees within its workspace. The system has been used to support an autonomous wrench-grasping experiment and significantly improved the workspace positioning of the hand based on visually derived wrench position. estimates.

Nickels, Kevin↗

Proposal and evaluation of subordinate standard solar irradiance spectra for applications in solar energy systems

Reference solar irradiance spectra are needed to specify key parameters of solar technologies such as photovoltaic cell efficiency, in a comparable way. The IEC 60904-3 and ASTM G173 standards present such spectra for Direct Normal Irradiance (DNI) and Global Tilted Irradiance (GTI) on a 37 degrees tilted sun-facing surface for one set of clear-sky conditions with an air mass of 1.5 and low aerosol content. The IEC/G173 standard spectra are the widely accepted references for these purposes. Hence, the authors support the future replacement of the outdated ISO 9845 spectra with the IEC spectra within the ongoing update of this ISO standard. The use of a single reference spectrum per component of irradiance is important for clarity when comparing and rating solar devices such as PV cells. However, at some locations the average spectra can differ strongly from those defined in the IEC/G173 standards due to widely different atmospheric conditions and collector tilt angles. Therefore, additional subordinate standard spectra for other atmospheric conditions and tilt angles are of interest for a rough comparison of product performance under representative field conditions, in addition to using the main standard spectrum for product certification under standard test conditions. This simplifies the product selection for solar power systems when a fully-detailed performance analysis is not feasible (e.g. small installations). Also, the effort for a detailed yield analyses can be reduced by decreasing the number of initial product options. After appropriate testing, this contribution suggests a number of additional spectra related to eight sets of atmospheric conditions and tilt angles that are currently considered within ASTM and ISO working groups. The additional spectra, called subordinate standard spectra, are motivated by significant spectral mismatches compared to the IEC/G173 spectra (up to 6.5%, for PV at 37 degrees tilt and 10-15% for CPV). These mismatches correspond to potential accuracy improvements for a quick estimation of the average efficiency by applying the appropriate subordinate standard spectrum instead of the IEC/G173 spectra. The applicability of these spectra for PV performance analyses is confirmed at five test sites, for which subordinate spectra could be intuitively selected based on the average atmospheric aerosol optical depth (AOD) and precipitable water vapor at those locations. The development of subordinate standard spectra for DNI and concentrating solar power (CSP) and concentrating PV (CPV) is also considered. However, it is found that many more sets of atmospheric conditions would be required to allow the intuitive selection of DNI spectra for the five test sites, due in particular to the stronger effect of AOD on DNI compared to GTI. In conclusion, the matrix of subordinate GTI spectra described in this paper are recommended to appear as an option in the annex of future standards, in addition to the obligatory use of the main spectrum from the ASTM G173 and IEC 60904 standards.

14 SOLAR ENERGY↗

Bifacial PV System Mismatch Loss Estimation

Nonuniform rear-irradiance on bifacial PV systems can cause additional mismatch loss, which may not be appropriately captured in PV energy production estimates and software. A simplified empirical relationship is presented that links the spatial variation of irradiance (to the resulting mismatch loss factor).

14 SOLAR ENERGY↗

Neutronics Analysis Supporting Baseline Fuel-Rodlet Irradiation Design in TREAT Multi-SERTTA Vehicle

The Transient Reactor Test (TREAT) Facility is a thermal-spectrum test reactor designed to evaluate reactor fuels and structural material under simulated nuclear excursion and transient power/cooling mismatch situations in nuclear reactors. TREAT was historically operated from 1959 through 1994. There are ongoing activities to resume its transient testing capabilities to support advanced reactor designs and validate computational predictions of fuel and core behavior. Such validation will be an important factor for review and approval of next generation power reactor design and safety evaluations. Historic methods used in TREAT were very approximate and served to estimate a predicted transient power shape. A number of calibration test experiments were then required prior to the actual transient test to better estimate the power that would have been deposited in the experiment during a transient pulse. Much of the experience in the use of these legacy methods has also been lost over the past two decades. Monte Carlo criticality codes are being utilized for calculation of the initial critical state, control rod reactivity worth, and power coupling between core and experiments. Current efforts primarily support neutronics characterization with safety and design analyses for the Multi-SERTTA (Static Environment Rodlet Transient Test Apparatuses) experiment test vehicle, which can accommodate up to four concurrent rodlets under separate environmental conditions. Ongoing efforts are necessary in preparation of transient testing support for Accident Tolerant Fuel (ATF) characterization and other future fuels testing requirements. The power coupling factor (PCF) is one of two key parameters utilized in designing and characterizing the performance of a TREAT fuel irradiation experiment. The second key parameter is the Transient Correction Factor (TCF) which accounts for time-dependent effects. The PCF is the effective quantity of fission-generated energy per mass of fuel specimen per total core energy. The quantity of energy deposited into a fuel rodlet under various test environments can be used to evaluate overall fuel performance, including failure mechanisms and thresholds. Baseline fuel rodlet calculations have been performed to estimate the effectiveness of the Multi-SERTTA test vehicle and optimization of PCF for various test conditions. The baseline serves as reference fuel pin conditions against which calibration and baseline experiments can be performed prior to actual ATF transient testing. Baseline experiments further serve to validate computational analyses and experimental test methods prior to design planning, experimentation, and evaluation of the ATF candidates. This paper serves to document activities performed to evaluate a reference Pressurized Water Reactor (PWR) rodlet design in the TREAT Multi-SERTTA test vehicle. (authors)

42 ENGINEERING↗