Search NASA⌕ Search

SEARCH · Search NASA

Results for “power system coherency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Structural Impact of Grid-Forming Inverters on Power System Coherency

This paper addresses the following fundamental research question: how does the integration of grid-forming inverters (GFMs) replacing conventional synchronous generators (SGs) impact the slow coherent eigen-structure and the low frequency oscillatory behavior of future power systems? Due to time-scale separated dynamics, generator states inside a coherent area synchronize over a fast time-scale due to stronger coupling, while the areas themselves synchronize over a slower time scale. Our mathematical analysis shows that due to the large-scale integration of GFMs, the weighted Laplacian structure of the frequency dynamics is preserved, however, the entries of the Laplacian may be significantly modified based on the location and penetration levels of the GFMs. This can impact and potentially significantly alter the coherency structure of the system. We have validated our findings with numerical results using the IEEE 68-bus test system.

Mukherjee, Sayak [BATTELLE (PACIFIC NW LAB)]↗

A compact and low power coherent optical system for on-board spacecraft data processing.

Discussion of the design and performance of a compact low-power coherent optical data processing system suitable for spacecraft onboard applications. The system is a modification of the conventional optical data processing system in which a much more efficient solid state GaAs laser is substituted for the bulky and inferior He-Ne laser and paraboloidal mirror segments are substituted for the axially symmetric optical system of the conventional data processing system. Theoretical considerations are given to substantiate the improvement of performance aimed at in the modified system. Preliminary tests of the modified design being in progress indicate that a low power, rugged, small size optical system, capable of onboard spacecraft data processing, can be constructed by using off-axis paraboloidal mirror segments.-

Husain-Abidi, A. S.↗

Tailoring coherent beam combined laser pulse trains for high peak and average power applications

Laser systems based on coherent beam combination (CBC) that rely on tiled pupil architecture intrinsically carry digital capabilities independently applicable to all three essential characteristics of a laser pulse: amplitude, phase and polarization. Those capabilities allow the far-field energy distribution to be flexibly tailored in real time. Operation in the femtosecond regime at high repetition rates gives access to a wide range of applications requiring both high peak and average powers. We address the task of independent peak versus average power adjustment needed for applications seeking to decouple nonlinear phenomena associated with GW peak power from the thermal load inherent to kW average power operation. The technical solutions proposed are presented in the framework of the Ecole Polytechnique XCAN CBC laser platform (61 independent channels) with an emphasis on thermal management measures implemented to ensure its nominal operation.

47 OTHER INSTRUMENTATION↗

Coherency-Aware Learning Control of Inverter-Dominated Grids: A Distributed Risk-Constrained Approach

Here, this letter investigates the importance of integrating the coherency knowledge for designing controllers to dampen sustained oscillations in wide-area power networks with significant penetration of inverter-interfaced resources. Coherency is a fundamental property of power systems, where time-scale separation in frequency dynamics leads to clustered behavior among generators of different groups. Large-scale penetration of inverter-driven low inertia resources replacing conventional synchronous generators (SGs) can lead to perturbation in the coherent partitioning; hence, integrating such information is of utmost importance for oscillation control designs. We present the coherency-aware design of a distributed output feedback-based reinforcement learning method that additionally incorporates risk constraints to capture the uncertainties related to net-load fluctuations. The use of domain-aware coherency information has produced improved training and oscillation performance than the coherency-agnostic control design, hence proving to be effective in controller design. Finally, we validated the proposed method with numerical experiments on the benchmark IEEE 68-bus test system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Meta-Level Framework for Evaluating Resilience in Net-Zero Carbon Power Systems with Extreme Weather Events in the United States

Important changes are underway in the U.S. power industry in the way that electricity is sourced, transported, and utilized. Disruption from extreme weather events and cybersecurity events is bringing new scrutiny to power-system resilience. Recognizing the complex social and technical aspects that are involved, this article provides a meta-level framework for coherently evaluating and making decisions about power-system resilience. It does so by examining net-zero carbon strategies with quantitative, qualitative, and integrative dimensions across discrete location-specific systems and timescales. The generalizable framework is designed with a flexibility and logic that allows for refinement to accompany stakeholder review processes and highly localized decision-making. To highlight the framework’s applicability across multiple timescales, processes, and types of knowledge, power system outages are reviewed for extreme weather events, including 2021 and 2011 winter storms that impacted Texas, the 2017 Hurricane Maria that affected Puerto Rico, and a heatwave/wildfire event in California in August 2020. By design, the meta-level framework enables utility decision-makers, regulators, insurers, and communities to analyze and track levels of resilience safeguards for a given system. Future directions to advance an integrated science of resilience in net-zero power systems and the use of this framework are also discussed.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Pulsed coherent solid-state 1.06-micron and 2.1-micron laser radar systems for remote velocity measurement

A low average power, pulsed, solid-state, 1.06-micron coherent laser radar (CLR) for range and velocity measurements of atmospheric and hard targets has been developed. The system has been operating at a field test site near Boulder, CO since September, 1988. Measurements have been taken on moving targets such as atmospheric aerosol particles, belt sanders, spinning disks, and various stationary targets. The field measurements have shown that this system exhibits excellent velocity measurement performance. A fast-tuning CW Nd:YAG oscillator has also been developed which has a frequency tuning range of greater than 30 GHz (which spans a target radial velocity range of over 16 km/s) and a tuning speed greater than 30 GHz/ms.

Henderson, Sammy W.↗

Diode laser power module for beamed power transmission

Recent progress with powerful, efficient, and coherent monolithic diode master-oscillator/power-amplifier (M-MOPA) systems is promising for the development of a space-based diode laser power station. A conceptual design of a 50-kW diode laser power module was made for space-based power stations capable of beaming coherent power to the moon, Martian rovers, or other satellites. The laser diode power module consists of a solar photovoltaic array or nuclear power source, diode laser arrays (LDAs), a phase controller, beam-steering optics, a thermal management unit, and a radiator. Thermal load management and other relevant aspects of the system (such as power requirements and system mass) are considered. The 50-kW power module described includes the highest available efficiency of LD M-MOPA system to date. However, the overall efficiency of three amplifier stages, including the coupling efficiency, turns out to be 55.5 percent. Though a chain of PA stages generates a high-power coherent beam, there is a penalty due to the coupling loss between stages. The specific power of the 50-kW module using solar power is 6.58 W/kg.

Choi, S. H.↗

The Urbana coherent-scatter radar: Synthesis and first results

A coherent scatter radar system was synthesized and several hundred hours of echo power and line of sight velocity data obtained. The coherent scatter radar utilizes a diode array and components from meteor radar. The receiving system permits a time resolution of one minute in the data. Echo power from the D region shows a high degree of variability from day to day. Examples of changes in power level at shorter time scales are observed. Velocity data show the existence of gravity waves and occasionally exhibit vertical standing wave characteristics.

Gibbs, K. P.↗

Decoherence from long-range forces in atom interferometry

Atom interferometers provide a powerful means of realizing quantum coherent systems with increasingly macroscopic extent in space and time. These systems provide an opportunity for a variety of novel tests of fundamental physics, including ultralight dark matter searches and tests of modifications of gravity, using long drop times and microgravity environments. However, as experiments operate with longer periods of free fall and become sensitive to smaller background effects, key questions start to emerge about the fundamental limits to future atom interferometry experiments. Here we study the effects on atomic coherence from hard-to-screen backgrounds due to baths of ambient particles with long-range forces, such as gravitating baths and charged cosmic rays. Our approach—working in the Heisenberg picture for the atomic motion—makes proper inclusion of the experimental apparatus feasible and clearly shows how to handle long-range forces. We find that these potential backgrounds are likely negligible for the next generation of interferometers, as aggressive estimates for the gravitational decoherence from a background bath of dark matter particles gives a decoherence timescale on the order of years.

74 ATOMIC AND MOLECULAR PHYSICS↗

Observations of solar-flare ionization in the mesosphere using coherent-scatter radar

Observations of solar-flare ionization in the mesosphere can be made using coherent-scatter radar systems. The scattered power profiles they measure in the 60-90 km altitude region is a function of the ion concentration gradient and the intensity of turbulent mixing at each altitude. By comparing the power profiles before, during and after a solar flare, it is possible to estimate the ion production rate during the flare as a function of altitude and time. This analysis is used to compare the ion production rates with generally accepted ion-chemical models. Comparisons are made with ion production rates estimated from the solar X-ray flux for the same flare made by geostationary satellites.

Parker, J. W.↗

High Power Laser Diode Arrays for 2-Micron Solid State Coherent Lidars Applications

Laser diode arrays are critical components of any diode-pumped solid state laser systems, constraining their performance and reliability. Laser diode arrays (LDAs) are used as the pump source for energizing the solid state lasing media to generate an intense coherent laser beam with a high spatial and spectral quality. The solid state laser design and the characteristics of its lasing materials define the operating wavelength, pulse duration, and power of the laser diodes. The pump requirements for high pulse energy 2-micron solid state lasers are substantially different from those of more widely used 1-micron lasers and in many aspects more challenging [1]. Furthermore, the reliability and lifetime demanded by many coherent lidar applications, such as global wind profiling from space and long-range clear air turbulence detection from aircraft, are beyond the capability of currently available LDAs. In addition to the need for more reliable LDAs with longer lifetime, further improvement in the operational parameters of high power quasi-cw LDAs, such as electrical efficiency, brightness, and duty cycle, are also necessary for developing cost-effective 2-micron coherent lidar systems for applications that impose stringent size, heat dissipation, and power constraints. Global wind sounding from space is one of such applications, which is the main driver for this work as part of NASA s Laser Risk Reduction Program. This paper discusses the current state of the 792 nm LDA technology and the technology areas being pursued toward improving their performance. The design and development of a unique characterization facility for addressing the specific issues associated with the LDAs for pumping 2-micron coherent lidar transmitters and identifying areas of technological improvement will be described. Finally, the results of measurements to date on various standard laser diode packages, as well as custom-designed packages with potentially longer lifetime, will be reported.

Amzajerdian, Farzin↗

Synergistic data analytics for electromechanical oscillation in electric power systems

Accurate real-time estimation of the four electromechanical oscillation properties, i.e., dominant oscillation modes, mode shapes, participation factors, and coherent groups, is of great importance to assess and mitigate potential electromechanical oscillations in interconnected power systems. While eigenvalue analysis can realize such estimation, it requires precise linearized dynamic models and accurate parameters, which are highly difficult to obtain in practice. Data fusion-based modal estimation methods can extract the properties of electromechanical oscillations from measurement data without the power system model and parameters, but most of the time only one or two property assessments can be accomplished each time. To overcome this challenge, this paper presents a synergistic data analytics solution to characterize the dynamic behaviors of electromechanical oscillations from real-time measurement data. Here, the proposed method uses optimized variable projection, and it is capable of estimating all four electromechanical oscillation behavior properties from measured responses. Case studies are performed using the simulated measurement data of a 16-generator 68-bus test system and the field measurements collected by the PMUs deployed in the Yunnan Power Grid. The results demonstrate that the proposed synergistic data analytics solution can achieve satisfactory performance in capturing the properties of electromechanical oscillations from measurement data and exhibit strong robustness against measurement noise when compared with existing measurement-based methods.

42 ENGINEERING↗

On the detection of differentially encoded polyphase signals.

Discussion of the transmission and detection of differentially encoded polyphase signals and of the ambiguity resolution problem which results from suppression of the transmitted carrier. In particular, an analysis is made of the performance of differentially encoded coherent multiple phase-shift keyed (MPSK) systems which reconstruct coherent reference signals by means of generalized Costas or nth-power loops. The performance of such systems is then compared with that of ideal reception of MPSK signals and differentially coherent detection of differentially encoded MPSK signals. Emphasis is placed upon the special cases of quadriphase and octaphase signaling.

Lindsey, W. C.↗

A Co-Simulation Framework for Steady-State Analyses of Multiple Droop-based MTdc Grids in Continental-Scale Systems

The growing scale and complexity of planning continental hybrid ac and multi-terminal dc (MTdc) systems require scalable steady-state modeling and analysis approaches not currently available in commercial tools. This paper presents a comprehensive multi-fidelity model-conversion framework that enables the efficient transition of MTdc grid models from production cost modeling (PCM) and approximated ac power flow to detailed ac–MTdc power flow for large-scale planning studies. The core of this framework is a scalable co-simulation approach that, for the first time, enables power flow analysis in continental-scale ac–MTdc systems. It seamlessly couples commercial ac solvers with a detailed MTdc grid model that incorporates droop-based control and current-limiting strategies of multiple meshed MTdc grids. Leveraging this capability, an evaluation framework to systematically assess and compare different MTdc power redispatch strategies under ac and dc contingencies is introduced. The proposed framework and algorithm are evaluated using a combined Western and Eastern Interconnection system with 11 MTdc grids of various sizes, showing a coherent transition from PCM to detailed ac–MTdc power flow and improved system performance in voltage regulation and line overload mitigation following typical contingencies.

Nguyen, Quan H.↗

Granger Causality for prediction in Dynamic Mode Decomposition: Application to power systems

Here, the dynamic mode decomposition (DMD) technique extracts the dominant modes characterizing the innate dynamical behavior of the system within the measurement data. For appropriate identification of dominant modes from the measurement data, the DMD algorithm necessitates ensuring the quality of the input measurement data sequences. On that account, for validating the usability of the dataset for the DMD algorithm, the paper proposed two conditions: Persistence of excitation (PE) and the Granger Causality Test (GCT). The virtual data sequences are designed with the hankel matrix representation such that the dimensions of the subspace spanning the essential system modes are increased with the addition of new state variables. The PE condition provides the lower bound for the trajectory length, and the GCT provides the order of the model. Satisfying the PE condition enables estimating an approximate linear model, but the predictability with the identified model is only assured with the temporal causation among data searched with GCT. The proposed methodology is validated with the application for coherency identification (CI) in a multi-machine power system (MMPS), an essential phenomenon in transient stability analysis. The significance of PE condition and GCT is demonstrated through various case studies implemented on 22 bus six generator system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-channel high-speed converter clock synchronization with autonomous coherent deterministic latency

A system and corresponding method that achieves coherency and deterministic latency (CDL) autonomously upon power on is disclosed. The system, for example, a multi-channel RF system, may require CDL with respect to the digital-to-analog converters (DACs) and analog-to-digital converters (ADCs) assigned to the channels in the system. CDL is achieved through a timed combination of external reference and synchronization signals, resetting and disabling of various clock dividers, and enabling clock generation. In addition to synchronizing all of the clocks, the data acquisition sequence must be synchronized across all of the channels, whether they are on chips, cards, or chassis. Data acquisition synchronization may be implemented using an initiator/target or a wired OR mode configuration.

Brady, Charles E.↗