Forced Power Systems Oscillations Due to Cyberattacks: Threats, Detection and Partial Mitigation

Forced oscillations in power systems can be caused by misconfigured controllers at generator stations. They can also be caused by cyberattacks against the exciters or governors. This paper explores the effects of forced oscillations from cyberattacks on generator excitation and governor systems and the effectiveness of a novel control system for a static var compensator in mitigating those oscillations to enhance transmission system resilience. A brief overview of oscillations, especially forced oscillations, within power systems is presented, along with an overview of cyberattacks on power systems. This paper also examines and implements FACTS devices to partially mitigate the forced oscillations created by cyberattacks by reducing the magnitude of the oscillations caused by the attack. The proposed approach is more effective against attacks targeting exciters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Demystifying Power System Oscillations - Recent and Ongoing Efforts

Summary of recent and ongoing research efforts in power system oscillation analysis and techniques for locating the source of oscillations. Review of existing technologies, best practice in industry, as well as challenges.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Approximation of the Frequency-Amplitude Curve Using the Homotopy Analysis Method

The Frequency-Amplitude (F-A) curve on power system oscillation under a large disturbance characterizes how a natural oscillation mode transitions to nonlinear oscillations with growing amplitudes and decaying frequencies. The existing formulation of the F-A curve is derived by solving elliptical integrals on oscillation of a single-machine-infinite-bus equivalent about the targeted oscillation mode. The formula is in a form of infinite series and needs to sum a large number of terms for satisfactory accuracy. This paper introduces an explicit, approximate expression obtained from the Homotopy Analysis Method on the F-A curve. The proposed F-A curve expression is derived from an SMIB system and verified on the IEEE 3-machine 9-bus system to show how the oscillation frequency of a dominant mode varies with oscillation amplitude under large disturbances.

frequency-amplitude (F-A) curve↗

Non-Stationary Power System Forced Oscillation Analysis using Synchrosqueezing Transform

Non-stationary forced oscillations (FOs) have been observed in power system operations. However, most detection methods assume that the frequency of FOs is stationary. In this paper, we present a methodology for the analysis of nonstationary FOs. Firstly, Fourier synchrosqueezing transform (FSST) is used to provide a concentrated time-frequency representation of the signals that allows identification and retrieval of non-stationary signal components. To continue, the Dissipating Energy Flow (DEF) method is applied to the extracted components to locate the source of forced oscillations. The methodology is tested using simulated as well as real PMU data. In conclusion, the results show that the proposed FSST-based signal decomposition provides a systematic framework for the application of DEF Method to non-stationary FOs.

42 ENGINEERING↗

A Robust Yule-Walker Method for Online Monitoring of Power System Electromechanical Modes of Oscillation

Reliable power system operation requires that system operators maintain a satisfactory small-signal stability margin at all times. Mode meters allow system operators to continuously monitor the stability margin by analyzing synchrophasor measurements. Experience with mode meters at the Bonneville Power Administration (BPA) has revealed that mode meters sometimes suffer severe bias following transient disturbances. In this paper, a robust version of the Yule-Walker mode meter algorithm is proposed to mitigate this bias. The robust capability is introduced by modifying the estimator of the autocovariance sequence (ACS) on which the algorithm depends. Tests with field-measured data demonstrate that the robust Yule-Walker (RYW) algorithm significantly outperforms its conventional counterpart and is better able to provide system operators with accurate information about the system's stability margin.

Follum, James D.↗

Room temperature, nanosecond, 60 mJ/pulse Fe:ZnSe master oscillator power amplifier system operating at 3.8-5.0 µm

We report on a RT gain-switched Fe:ZnSe master oscillator power amplifier (MOPA) system tunable over 3.8–5.0 µm pumped by radiation of Er:YAG laser operating at 2.94 µm. The mechanically Q-switched Er:YAG laser with output energy up to 220 mJ was used as a pump source for a master oscillator and three-stage power amplifier. The maximum output energies in 200 ns pulses exceeded 60, 56, and 48 mJ at 4.4, 4.3, and 4.1 µm, respectively, under 220 mJ of pump energy. The extraction energy efficiencies were measured to be 25, 30, and 40% at the first, second, and third stages, respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

1047 nm laser diode master oscillator Nd:YLF power amplifier laser system

A master oscillator power amplifier (MOPA) laser transmitter system at 1047 nm wavelength using a semiconductor laser diode and a diode pumped solid state (Nd:YLF) laser (DPSSL) amplifier is described. A small signal gain of 23 dB, a near diffraction limited beam, 1 Gbit/s modulation rates and greater than 0.6 W average power are achieved. This MOPA laser has the advantage of amplifying the modulation signal from the laser diode master oscillator (MO) with no signal degradation.

Yu, A. W.↗

A Reversed Impedance-Based Stability Criterion for IBR Grids

The existing impedance-based stability criterion is effective for analyzing local control interactions; however, it is difficult to scale the existing criterion to analyze wide-area control interactions among numerous IBRs through a complex power system network. The scaled version of the existing criterion requires the impedance response of each IBR in the system as well as of the network looking from all the IBRs. It is quite challenging to obtain all these impedance responses because of the computational effort and the requirement of separately scanning the impedance of the network and the IBRs. We propose a reversed criterion for the impedance-based stability analysis to address these problems. In contrast to the existing criterion, the reversed criterion analyzes the stability of a power system when an IBR is disconnected from the system. The reversed criterion estimates the impact of an IBR on the frequency and damping of power system oscillation modes using the impedance scans of only the IBR and the grid at its terminal. It can be sequentially applied at different IBRs to evaluate their impact on the power system stability. In addition to scalability, the reversed criterion gives flexibility to focus only on a few selected IBRs, depending on their rating, the magnitude of oscillations observed at their terminals, and the vendor support available for implementing stabilizing control system updates. The reversed criterion is demonstrated on a 14-bus power system with 100% IBRs.

control interactions↗

Synergistic data analytics for electromechanical oscillation in electric power systems

Accurate real-time estimation of the four electromechanical oscillation properties, i.e., dominant oscillation modes, mode shapes, participation factors, and coherent groups, is of great importance to assess and mitigate potential electromechanical oscillations in interconnected power systems. While eigenvalue analysis can realize such estimation, it requires precise linearized dynamic models and accurate parameters, which are highly difficult to obtain in practice. Data fusion-based modal estimation methods can extract the properties of electromechanical oscillations from measurement data without the power system model and parameters, but most of the time only one or two property assessments can be accomplished each time. To overcome this challenge, this paper presents a synergistic data analytics solution to characterize the dynamic behaviors of electromechanical oscillations from real-time measurement data. Here, the proposed method uses optimized variable projection, and it is capable of estimating all four electromechanical oscillation behavior properties from measured responses. Case studies are performed using the simulated measurement data of a 16-generator 68-bus test system and the field measurements collected by the PMUs deployed in the Yunnan Power Grid. The results demonstrate that the proposed synergistic data analytics solution can achieve satisfactory performance in capturing the properties of electromechanical oscillations from measurement data and exhibit strong robustness against measurement noise when compared with existing measurement-based methods.

42 ENGINEERING↗

A Reversed Impedance-Based Stability Criterion for IBR Grids: Preprint

The existing impedance-based stability criterion is effective for analyzing local control interactions; however, it is difficult to scale the existing criterion to analyze wide-area control interactions among numerous IBRs through a complex power system network. The scaled version of the existing criterion requires the impedance response of each IBR in the system as well as of the network looking from all the IBRs. It is quite challenging to obtain all these impedance responses because of the computational effort and the requirement of separately scanning the impedance of the network and the IBRs. We propose a reversed criterion for the impedance-based stability analysis to address these problems. In contrast to the existing criterion, the reversed criterion analyzes the stability of a power system when an IBR is disconnected from the system. The reversed criterion estimates the impact of an IBR on the frequency and damping of power system oscillation modes using the impedance scans of only the IBR and the grid at its terminal. It can be sequentially applied at different IBRs to evaluate their impact on the power system stability. In addition to scalability, the reversed criterion gives flexibility to focus only on a few selected IBRs, depending on their rating, the magnitude of oscillations observed at their terminals, and the vendor support available for implementing stabilizing control system updates. The reversed criterion is demonstrated on a 14-bus power system with 100% IBRs.

control interactions↗

A Data-Driven Exploration of the Impact of Renewable Energy on Inter-Area Oscillations in the U.S. Eastern Interconnection

As increasing amounts of renewable energy (RE) resources are incorporated into the bulk-power grid, power system oscillations are expected to change. This work investigates how RE generation impacts the frequency and damping ratio (DR) of two dominant inter-area modes in the U.S. Eastern Interconnection (EI) using regularly updated estimates collected over a 12-month period. Quantile regression is used to derive the correlation between operating conditions and mode properties, and a bootstrap method is used to quantify the uncertainty associated with the correlation estimates. Results show that with an increase in system load, the frequency of a mode decreases and DR increases. Evidence that increasing RE generation results in an increase in frequency and decline in DR was found for one of the two modes studied. This work shows that increasing RE levels will impact the properties of inter-area oscillations in the EI, but it does not indicate the presence of immediate threats to grid stability. The outlined approach can be used to periodically assess changing mode properties as RE levels continue to grow and flag stability concerns before they become serious reliability threats.

Inter-area oscillation, mode meters, quantile regr↗

Coordinated Control of Natural and Sub-Synchronous Oscillations via HVDC Links in Great Britain Power System

Conventional power oscillation damping (POD) controllers have been designed to be effective in damping either inter-area low-frequency oscillations (LFO) or sub-synchronous oscillations (SSO). For those POD controls, model-based control design method has been widely implemented with wide-area feedback signals from phasor measurement units (PMU). However, the model accuracy of a large realistic power system can hardly be guaranteed, which will finally impact the POD damping performance. In this paper, a measurement-based method is proposed for POD design using High Voltage Direct Current links (HVDC) to realize the coordinated control of both LFO and SSO. For each type of oscillations, a band-pass filter is added to avoid the interactions between different modes. Case studies are carried out on the Great Britain 36-bus power system model with multiple HVDC links in DIgSILENT/PowerFactory. Simulation results demonstrate that the proposed PODs are effective in damping inter-area LFO and SSO simultaneously.

Zhao, Yi↗

Estimation of Participation Factors Using the Synchrosqueezed Wavelet Transform

This paper proposes a data-driven approach for estimating participation factors for a power system using only simulation results on selected disturbances. The approach is purely response-based and does not need a linearized system model for eigen-analysis, which makes it applicable to systems whose detailed, complete mathematical models are not available. Considering the unavoidable nonlinearity as exhibited in the transient period of a system response, the Synchrosqueezed Wavelet Transform is applied to simulated responses for modal analysis to obtain participation factors. Based on simulations of Kundur's two-area system using both the electromagnetic transient model and phasor model, the participation factors estimated by the proposed approach are compared with two other signal processing tools, the Prony analysis and continuous wavelet transform, and are also benchmarked with conventional model-based participation factors.

participation factor↗

A Practical On-line Framework for a Modified Energy Detector by Whitening Ambient PMU Data

A key application of Phasor Measurement Units (PMUs) is power system oscillation detection. An energy detector is a straightforward detection method, but setting thresholds requires extensive and time consuming baselining of data. This paper proposes a novel on-line method of whitening PMU measurements supporting a framework for detecting forced oscillations without requiring extensive baselining. An example of 24 hours of actual PMU data illustrates how a forced oscillation is very visible in the energy signal of the whitened data, while being hard to detect in the colored ambient noise. With this framework, the statistical theory for setting thresholds without baselining is much more straightforward and is the focus of future work.

Xu, Zikai↗

Forced Oscillation Source Location in Power Systems Using MVMD-assisted DEF in TF Plane

Fast and accurate forced oscillation source location (FOSL) is critical for mitigating forced oscillations in power systems. Here, to overcome the shortcomings of traditional dissipating energy flow (DEF) in decomposing the forced oscillation components from the measurement responses, a multivariate variational mode decomposition (MVMD)-assisted FOSL is proposed in this paper to locate the forced oscillation sources from measurements in time-frequency (TF) plane. The multi-channel measurement matrix of each generator is formed, then the multi-channel modes are decomposed from the formed multi-channel measurement matrix using the MVMD. Further, the intrinsic mode functions (IMFs) associated with the forced oscillation mode are distinguished from the decomposed modes according to the relative energy weights. With the distinguished IMFs, the MVMD-assisted DEF calculation method is developed to locate the forced oscillation source. Finally, the performance of the proposed method is evaluated using the simulation data of the WECC 179-bus test system and IEEE-NASPI Oscillation Source Location Contest as well as the actual PMU data of ISO New England. The results validated the effectiveness and accuracy of the proposed method in the FOSL.

24 POWER TRANSMISSION AND DISTRIBUTION↗