Search NASA⌕ Search

SEARCH · Search NASA

Results for “power transformers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Intercell Power Transformer for Power Balancing of Polyphase Wireless Power Transfer Systems

Polyphase wireless power transfer (PWPT) systems experience receiver side imbalances in misaligned conditions. This paper proposes a method for power balancing in PWPT systems, specifically addressing the challenges caused by receivers coil unequal coupling. An intercell power transformer (IPT) is introduced at the receiver side to mitigate the effects of coil mismatch. Simulations of the PWPT system incorporating IPT demonstrate its effectiveness in enhancing power distribution. For voltage-fed rectifiers (VFR), the IPT increases the conduction angle, resulting in higher output power. In current- fed rectifiers (CFR), the IPT promotes uniform power sharing among rectifiers, thereby reducing electrical stress on semiconductor devices and passive components. Simulation results indicate that, under coil misalignment, the IPT improves output power by approximately 49% for VFRs and 44% for CFRs compared to conventional PWPT systems without IPT.

Wojda, Rafal [ORNL] (ORCID:0000000286609268)↗

Computational Analysis and Optimized Modeling of Geomagnetically Induced Currents in Power Transformers

In this project we aim to better understand the effect of geomagnetically induced currents (GIC) on power transformers. Expanding upon our previous work focused on producing a methodology for accuracy-enhanced computation of GIC signatures (i.e., time-domain current magnitude variation for the event duration) from a combination of physics-based and data-driven computational tools, we propose the use of these GIC signatures as inputs for a physically-detailed and optimized model of the power transformer to investigate how GIC determination and transformer modeling influence the evaluation of GIC effects on the transformer operation, as well as in its interaction with the power grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Seismic Resilience of Large Power Transformer Bushings & Non-SF6 Industrial Base Scan Review

Large (high voltage) power transformers (LPT), and more specifically, their bushings, are known to be susceptible to seismic failure. With bushing failure, a transformer will have to be replaced, which has a considerable lead time, adding to the power outage duration. Cost-efficient, proven solutions are not currently available to mitigate this risk, which can persist for the more than 30-year life of a particular transformer. This work will focus on developing and demonstrating a hardware solution to address seismic vulnerabilities and reduce outage risks from LPT failure. Sulfur Hexafluoride (SF6) is a specialty gas with excellent electrical insulation properties which has been used extensively in the power industry. This gas is unfortunately also one of the most potent greenhouse gases known to humanity. A 2014 report by the Intergovernmental Panel on Climate Change found that SF6 has a global warming potential (GWP) 23,000 times higher than Carbon Dioxide, and has the highest GWP of all gases assessed (Myhre 2013). SF6 is almost exclusively man-made and is produced for use as an insulator in high voltage electrical equipment. This makes the production and use of SF6 one of the leading sources of anthropogenic climate change. To fully eliminate the environmental impacts of SF6, alternative technology is needed. The ideal replacement would be a technology that can fulfil the same role as SF6, at the same cost or cheaper, but without adverse environmental effects. Currently, no technology fits this description, however several promising technologies have begun to enter the market. An industry scan was performed to assess the state of industry adoption and manufacturing capability for SF6-free alternative technologies for use at the high-voltage level, and the primary barriers to broader adoption.

10 SYNTHETIC FUELS↗

Large Power Transformer Supply Chain Gap Analysis and Domestic Content Strategies for Hydropower Rehabilitation: Supplemental Report

Large Power Transformers (LPTs) are indispensable to U.S. hydropower operations, serving as generator step-up (GSU) units that interconnect hydro facilities to the transmission grid. Yet the LPT supply chain faces mounting stress from aging infrastructure, limited domestic production, and long lead times. Currently, more than 80% of LPT demand is met through imports, with primary suppliers including Mexico, South Korea, Brazil, Austria, and Canada. Domestic manufacturers supply only about 20% of units, constrained by bottlenecks in high-grade Grain-Oriented Electrical Steel (GOES), copper conductors, bushings, and on-load tap changers (OLTCs). Hydropower rehabilitation projects in particular face additional challenges due to custom design requirements, remote siting, and regulatory needs around domestic content. Regional cost disparities, driven by transportation logistics, labor markets, and import price volatility, further exacerbate project risks. To address these vulnerabilities, coordinated action is required: strengthening domestic capacity for GOES and secondary components, developing near-site assembly hubs, and leveraging IRS domestic content safe harbors to incentivize U.S. manufacturing. This addendum refines the 2024 NREL Hydropower Supply Chain Gap Analysis by focusing specifically on critical issues related to LPT domestic manufacturing capacity and key considerations for hydropower developers and asset owners.

13 HYDRO ENERGY↗

Volume and Mass Estimation of Three-Phase High Power Transformers for Space Applications

Spacecraft historically have had sub-1kW(sub e), electrical requirements for GN&C, science, and communications: Galileo at 600W(sub e), and Cassini at 900W(sub e), for example. Because most missions have had the same order of magnitude power requirements, the Power Distribution Systems (PDS) use existing, space-qualified technology and are DC. As science payload and mission duration requirements increase, however, the required electrical power increases. Subsequently, this requires a change from a passive energy conversion (solar arrays and batteries) to dynamic (alternator, solar dynamic, etc.), because dynamic conversion has higher thermal and conversion efficiencies, has higher power densities, and scales more readily to higher power levels. Furthermore, increased power requirements and physical distribution lengths are best served with high-voltage, multi-phase AC to maintain distribution efficiency and minimize voltage drops. The generated AC-voltage must be stepped-up (or down) to interface with various subsystems or electrical hardware. Part of the trade-space design for AC distribution systems is volume and mass estimation of high-power transformers. The volume and mass are functions of the power rating, operating frequency, the ambient and allowable temperature rise, the types and amount of heat transfer available, the core material and shape, the required flux density in a core, the maximum current density, etc. McLyman has tabulated the performance of a number of transformers cores and derived a "cookbook" methodology to determine the volume of transformers, whereas Schawrze had derived an empirical method to estimate the mass of single-phase transformers. Based on the work of McLyman and Schwarze, it is the intent herein to derive an empirical solution to the volume and mass estimation of three-phase, laminated EI-core power transformers, having radiated and conducted heat transfer mechanisms available. Estimation of the mounting hardware, connectors, etc. is not included.

Kimnach, Greg L.↗

Description of a 2.3 kW power transformer for space applications

The principle features and special testing of a high voltage high power transformer designed and developed for space application are described. The transformer is operated in a series resonant inverter supplying beam power to a 30 cm mercury ion thruster. Electrical requirements include operation of 2.3 kW continuous power output, primary currents to 35 amps rms, and frequencies up to 20 kHz. High efficiency was obtained through detailed considerations of the tradeoffs available in core materials, wire selection, coil configurations and thermal control. A number of novel heat removal techniques are discussed which control the winding temperature using only the available conductive cooling.

Hansen, I.↗

Description of A 2.3 kW power transformer for space applications

The paper describes the principal features and special testing of a high-frequency high-power low-specific-weight (0.57 kg/kW) 2.3-kW electronic power transformer developed for space applications. The transformer is operated in a series resonant inverter supplying beam power to a 30-cm mercury ion thruster. High efficiency (above 98.5%) is obtained through careful detailed design. A number of unique heat removal techniques are discussed which control the winding temperature using only the available conductive cooling.

Hansen, I.↗

Rotary Power Transformer and Inverter Circuit

Noise lower than with sliprings. Rotary transformer transfers electric power across rotary joint. No wearing contacts, no contact noise, and no contamination from lubricants or wear debris. Because additional inductor not required, size and complexity of circuit reduced considerably.

Mclyman, C. W. T.↗

Geomagnetically Induced Current Field Test on Large Grid-Connected Power Transformers: Analysis, Model Development, and Simulations

Geomagnetic-induced current (GIC) flow in power grids can cause undesirable effects such as transformer overheating, harmonics, higher reactive power demand, etc. Many simulation models have been developed to study these effects, but real-world verification on modern transformer designs is rare. Here, this paper presents the first long-duration GIC field test in the U.S. performed on high-voltage, grid-connected transformers featuring winding clamps and tie rods instead of conventional tie bars. Field measurements were taken to evaluate GIC effects. These measurements also aided in developing and validating thermal and electromagnetic transient (EMT) models of the transformers. During the test, significant current and voltage distortions were observed along with considerable transformer reactive power losses. Analysis of the field measurements showed that the transformers’ hottest spot was at the inner windings, and their k-factors were close to factory test and software default values. Thermal simulations indicated that the transformers would not violate their thermal limits even for a GIC waveform that peaks at about 200 A/phase. EMT simulations revealed that increased transformer loading may reduce GIC-induced reactive power demand and harmonics in certain scenarios. The study also highlighted potential inaccuracies in using the k-factor method to calculate transformer reactive power losses.

EMTDC↗

Development of a rotary power transformer and inverter drive for spacecraft

Many future satellites and spacecraft with spun and despun configurations will require the transfer of power across rotating interfaces in lieu of slip-rings and/or flexures. This is particularly true of spacecraft that have to demonstrate a long life expectancy. The rotary transformer has the desirable characteristics of high reliability and low noise, which qualify it as a potential replacement for slip rings. Development of a rotary power transformer follows the successful completion of a task to develop rotary signal-level transformers for the Galileo Spacecraft Project. The physical configuration of a rotary power transformer has a significant effect on its magnetic and electrical characteristics and therefore impacts the design of the dc/ac inverter driver. Important characteristics addressed during this development effort include: operating frequency, efficiency, transformer gap size, leakage inductance, and leakage flux. A breadboard inverter and rotary transformer were designed, fabricated and tested.

Mclyman, W. T.↗

Transformer-powered surrogates close the ICF simulation-experiment gap with extremely limited data

Abstract Recent advances in machine learning, specifically transformer architecture, have led to significant advancements in commercial domains. These powerful models have demonstrated superior capability to learn complex relationships and often generalize better to new data and problems. This paper presents a novel transformer-powered approach for enhancing prediction accuracy in multi-modal output scenarios, where sparse experimental data is supplemented with simulation data. The proposed approach integrates transformer-based architecture with a novel graph-based hyper-parameter optimization technique. The resulting system not only effectively reduces simulation bias, but also achieves superior prediction accuracy compared to the prior method. We demonstrate the efficacy of our approach on inertial confinement fusion experiments, where only 10 shots of real-world data are available, as well as synthetic versions of these experiments.

97 MATHEMATICS AND COMPUTING↗

High-Efficiency, Low-Weight Power Transformer

Technology for design and fabrication of radically new type of conductioncooled high-power (25 kVA) lightweight transformer having outstanding thermal and electrical characteristics. Fulfills longstanding need for conduction-cooled transformers and magnetics with low internal thermal resistances. Development techniques limited to conductive heat transfer, since other techniques such as liquid cooling, forced liquid cooling, and evaporative cooling of transformers impractical in zero-gravity space environment. Transformer uniquely designed: mechanical structure also serves as thermal paths for conduction cooling of magnetic core and windings.

Welsh, J. P.↗

20 kHz, 25 kVA node power transformer

The electrical and mechanical design information and the electrical and thermal testing performed on the 440-208-V rms, 20-kHz, 25-kVa prototype node transformer are summarized. The calculated efficiency of the node transformer is 99.3 percent based on core loss and copper loss test data, and its maximum calculated load regulation is 0.7 percent. The node transformer has a weight of 19.7 lb and has a power density of 0.8 lb/kW. The hot-spot temperature rise is estimated to be 33 C above the cold plate mounting base. This proof-of-concept transformer design is a viable candidate for the space station Freedom application.

Hussey, S.↗

Design of space-type electronic power transformers

Both open and encapsulated varieties of high reliability, low weight, and high efficiency moderate and high voltage transformers were investigated to determine the advantages and limitations of their construction in the ranges of power and voltage required for operation in the hard vacuum environment of space. Topics covered include: (1) selection of the core material; (2) preliminary calculation of core dimensions; (3) selection of insulating materials including magnet wire insulation, coil forms, and layer and interwinding insulation; (4) coil design; (5) calculation of copper losses, core losses and efficiency; (6) calculation of temperature rise; and (7) optimization of design with changes in core selection or coil design as required to meet specifications.

Ahearn, J. F.↗

Electronic-Power-Transformer Design Guide

Compilation of information on design procedures, electrical properties, and fabrication. Guide provides information on design procedures; magnetic and insulating material electrical properties; impregnating, encapsulating and processing techniques.

Schwarze, G. E.↗