Portable Dynamic Pressure Calibrator

A portable, dynamic pressure calibrator was fabricated for use on wind tunnel models at NASA-Ames Research Center. The calibrator generates sine wave pressures at levels up to 1 PSIG P-P(168dB) at frequencies from 10Hz to 6KHz and .5 PSIG P.P (162dB) at frequencies from 6KHz to 20KHz. The calibrator consists of two units connected by a single cable. The handheld unit contains a pressure transducer, speaker, and deadman switch. This unit allows application of dynamic pressure to transducers/ports on installed wind tunnel models. The base unit contains all of power supplies, controls and displays. This unit allows amplitude and frequency to be set and verified at a safe location off of the model.

Wright, Morgan S.↗

A dynamic pressure calibration standard

A dynamic pressure calibration standard has been developed for calibrating flush diaphragm mounted pressure transducers. Pressures up to 20 kPa (3 psi) have been accurately generated over a frequency range of 50 to 1800 hz. The uncertainty of the standard is +/-5 pct to 5kPa (.75 psi) and +/-10 pct from 5 kPa (.75 psi) to 20 kPa (3 psi). The system consists of two conically shaped, aluminum columns, one 5 cm (2 in.) high for low pressures and another 11 cm (4.3 in.) high for higher pressures, each filled with a viscous fluid. A column is mounted on the armature of a vibration exciter which imparts a sinusoidally varying acceleration to the fluid column. Two pressure transducers mounted at the base of the column sense the sinusoidally varying pressure. This pressure is determined from measurements of the density of the fluid, the height of the fluid, and the acceleration of the column. A section of the taller column is filled with steel balls to control the damping of the fluid to extend its useful frequency range.

Schutte, P. C.↗

Dynamic Pressure Calibration Standard

Vibrating columns of fluid used to calibrate transducers. Dynamic pressure calibration standard developed for calibrating flush diaphragm-mounted pressure transducers. Pressures up to 20 kPa (3 psi) accurately generated over frequency range of 50 to 1,800 Hz. System includes two conically shaped aluminum columns one 5 cm (2 in.) high for low pressures and another 11 cm (4.3 in.) high for higher pressures, each filled with viscous fluid. Each column mounted on armature of vibration exciter, which imparts sinusoidally varying acceleration to fluid column. Signal noise low, and waveform highly dependent on quality of drive signal in vibration exciter.

Schutte, P. C.↗

Self-Calibrating Pressure Transducer

A self-calibrating pressure transducer is disclosed. The device uses an embedded zirconia membrane which pumps a determined quantity of oxygen into the device. The associated pressure can be determined, and thus, the transducer pressure readings can be calibrated. The zirconia membrane obtains oxygen .from the surrounding environment when possible. Otherwise, an oxygen reservoir or other source is utilized. In another embodiment, a reversible fuel cell assembly is used to pump oxygen and hydrogen into the system. Since a known amount of gas is pumped across the cell, the pressure produced can be determined, and thus, the device can be calibrated. An isolation valve system is used to allow the device to be calibrated in situ. Calibration is optionally automated so that calibration can be continuously monitored. The device is preferably a fully integrated MEMS device. Since the device can be calibrated without removing it from the process, reductions in costs and down time are realized.

Lueck, Dale E.↗

Simultaneous x-ray diffraction measurements of nine pressure calibrants to 140 GPa

Accurate pressure calibration is fundamental to quantitative high-pressure science, yet inconsistencies among widely used secondary pressure scales persist. In this work, we report simultaneous synchrotron x-ray diffraction meatogether in diamond anvil cells to 140 GPa. This simultaneous-measurement strategy minimizes transitive errors and run-to-run inconsistencies inherent to paired-measurement approaches, yielding direct experimental volume-volume (V-V) relations among the calibrants. These V-V relations link the compression state of each phase to that of every other phase measured in the same experiment. By anchoring these V-V relations to the reduced 300 K equation of state (EOS) of copper derived from ramp-compression measurements, we derive an internally consistent set of Cu-referenced pressure scales via Vinet EOS fits. Because the primary experimental result is the V-V dataset, it provides an EOS-independent constraint that can be rereferenced if primary standards are revised. The dataset further enables a direct experimental cross-check of consistency between the adopted reduced 300 K Cu EOS and the corresponding reduced 300 K ramp-derived EOSs for Pt, Au, Ta, and hcp-Fe under a fixed V-V constraint. The residuals quantify small, material-dependent mismatches between each phase EOS and the Cu reference EOS.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Raman scattering of rhenium for secondary pressure calibration

With the increasing number of 100 s GPa experiments in the diamond anvil cell (DAC), improved accuracy in secondary pressure calibrations to extreme pressures is essential. The rhenium equation of state has been proposed as a pressure calibrant via x-ray diffraction with potentially broad applications as it is commonly used as a gasket material in DAC experiments. In this work, we conducted Raman spectroscopy experiments on rhenium in the DAC and report the pressure shift of the E2g mode, a refined high-pressure C44 and mode-Grüneisen parameter above 200 GPa. We used flat, beveled, and toroidal diamond anvils under quasi-hydrostatic and non-hydrostatic conditions. By measuring the E2g mode from the culet edge to the center, we analyzed pressure distribution based on culet type and distance from the anvil center. The shift in the E2g mode can be expressed as a function of pressure, and diamond edge measurements appear reliable across all anvil types. Comparing the center and edge pressures reveals anvil cupping, offering insights into predicting or preventing anvil failure during materials properties measurements at extreme conditions.

Diamond anvil cells↗

An interlaboratory comparison of piston-cylinder pressure calibration using the albite-breakdown reaction.

An attempt is made to compare pressure calibration methods among several laboratories in an unbiased way to produce some indication of the bandwidth of observations on the pressure of an equilibrium reaction where sources of discrepancy not resulting from pressure calibration are likely to have been eliminated. The reaction chosen is the breakdown of albite to jadeite and quartz under pressure.

Johannes, W.↗

Voltage-To-Frequency Converter For Pressure Calibration

Measurements of pressures on walls of wind tunnels and on surfaces of models in wind tunnels made with help of electronically scanned pressure-measurement (ESP) system. Voltage-to-frequency converter circuit, designed to convert 0- to 5-Vdc analog output voltage from high-line-pressure, low-differential-pressure standard to required frequency range. Enables selection of wider variety of high-accuracy pressure standards to enhance accuracy of measurement of ESP instrumentation while requiring little modification of manufacturer's system and no modification of operating software of system. Useful primarily in wind-tunnel instrumentation and readily adaptable to commercial instruments currently in use.

Sealey, Bradley S.↗

System for calibrating pressure transducer

A system for calibrating a pressure transducer which has a reference portion and an active portion is reported. A miniature selector valve is positioned immediately adjacent the pressure transducer. A reference pressure, known pressure, and unknown pressure can be selectively admitted to the active side of the pressure transducer by the selector valve to enable calibration of the transducer. A valve admits pressure to the selector valve which has a piston and floating piston arrangement which allows proper selection with very small linear movement.

Rollins, G. N.↗

Cryogenic Pressure Calibrator for Wide Temperature Electronically Scanned (ESP) Pressure Modules

Electronically scanned pressure (ESP) modules have been developed that can operate in ambient and in cryogenic environments, particularly Langley's National Transonic Facility (NTF). Because they can operate directly in a cryogenic environment, their use eliminates many of the operational problems associated with using conventional modules at low temperatures. To ensure the accuracy of these new instruments, calibration was conducted in a laboratory simulating the environmental conditions of NTF. This paper discusses the calibration process by means of the simulation laboratory, the system inputs and outputs and the analysis of the calibration data. Calibration results of module M4, a wide temperature ESP module with 16 ports and a pressure range of +/- 4 psid are given.

Faulcon, Nettie D.↗

Fixture For Calibrating Pressure Probe

Fixture in form of specially designed clamshell housing enables in situ calibration of pressure transducer mounted in body of pressure probe in wind tunnel. Includes two metal half shells machined with necks and matching cavities, when put together, define larger neck and cavity accommodating probe. Probe secured to bottom half shell by use of clamp before installing top half shell: necessary to follow sequence to protect probe during assembly. Clamshell calibration fixture attached to pressure probe in few minutes, making it possible to calibrate pressure transducer at convenient times. Calibrations performed before and after wind-tunnel runs each day, between runs in event of delays or suspected malfunctions, and essentially any other time, without having to remove probe from wind tunnel.

Ashby, George C., Jr.↗

A technique for dynamically calibrating pressure transducers at cryogenic temperatures

A technique was developed for the calibration of dynamic pressure transducers at cryogenic temperatures. The calibration system utilizes an 8.9 Newton peak thrust shaker which oscillates a helium-filled bellows to generate a sinusoidal dynamic pressure to calibrate transducers immersed in a cryogenic environment. The system has a dynamic pressure measurement uncertainty of approximately 11% and is capable of producing peak-to-peak dynamic pressure amplitudes of 1.4 kPa over a frequency range of 40 to 100 hertz and a temperature range of 100 to 300 K. It provides an unprecedented capability of both static and dynamic calibration of pressure transducers from ambient to cryogenic temperature.

Gibbens, B. V.↗

High frequency dynamic pressure calibration technique

A high frequency dynamic calibration technique for pressure transducers has been developed using a siren pressure generator (SPG). The SPG is an inlet-area-modulated device generating oscillating waveforms with dynamic pressure amplitudes up to 58.6 kPa (8.5 psi) in a frequency range of 1 to 10 kHz. A description of the generator, its operating characteristics and instrumentation used for pressure amplitude and frequency measurements is given. Waveform oscillographs and spectral analysis of the pressure transducers' output signals are presented.

Davis, P. A.↗

National Transonic Facility Wall Pressure Calibration Using Modern Design of Experiments (Invited)

The Modern Design of Experiments (MDOE) has been applied to wind tunnel testing at NASA Langley Research Center for several years. At Langley, MDOE has proven to be a useful and robust approach to aerodynamic testing that yields significant reductions in the cost and duration of experiments while still providing for the highest quality research results. This paper extends its application to include empty tunnel wall pressure calibrations. These calibrations are performed in support of wall interference corrections. This paper will present the experimental objectives, and the theoretical design process. To validate the tunnel-empty-calibration experiment design, preliminary response surface models calculated from previously acquired data are also presented. Finally, lessons learned and future wall interference applications of MDOE are discussed.

Underwood, Pamela J.↗

Calibrating Pressure Transducers at Cryogenic Temperatures

To calibrate transducers immersed in cryogenic environment, sealed reciprocating bellows generates sinusoidal dynamic pressure. Transducer manifold assembly and bellows immersed in cryogenic environment to minimize gradients in controllable cryogenic temperature.

Gibbens, B. V.↗