Search NASA⌕ Search

SEARCH · Search NASA

Results for “pressure drop oscillation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Flow Instabilities in boiling channels and their suppression methodologies—A review

Small modular reactors (SMRs) are gaining significant attention as a promising solution for clean and sustainable nuclear-power generation. However, the operation of SMRs is subject to various challenges, including two-phase flow instabilities. Flow instability has the potential to trigger flow-induced vibration and cyclic fluctuations in local thermal stress. These instabilities frequently manifest because of the complex interplay among a multitude of factors, encompassing thermal-hydraulic conditions, the geometric configuration of the steam generator, and operational parameters. These conditions could subsequently lead to premature critical heat flux, equipment malfunctions, and other safety concerns. Here, the endeavor to address steam-generator flow instabilities is of utmost importance in augmenting the sustainability and efficiency of contemporary energy production. This study offers a comprehensive review of instabilities in two-phase flow, with a particular focus on the influential factors impacting the stability of flow boiling. Furthermore, it delves into the processes of identifying, characterizing, and ameliorating these instabilities, emphasizing pivotal findings, methodologies employed, and avenues for prospective research. The primary parameters of concern encompass the efficient transfer of thermal energy, the optimization of mass-flow rates, and the establishment of favorable boundary conditions, all in the context of steam generator design to alleviate instability for water-cooled SMRs. These discernments bear substantial ramifications for enhancing reactor performance and ensuring operational safety.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

FY-24 Progress on Computational Modeling of the Water Based NSTF

This report summarizes the computational modeling of the Natural Convection Shutdown Heat Removal Test Facility (NSTF) completed in FY24. This year’s modeling campaign focuses on the continual testing of the RELAP5 model against experimental data. Several fault cases were simulated with the RELAP5 model in FY23 to study the accuracy of the model under complex flow conditions. Similarly, in FY24, a case is simulated where the chimney outlet is throttled with a valve while the flow is undergoing two-phase oscillations. The purpose of this case is to study the effects of increasing pressure drop in the two-phase region on the system behavior. Even though the model is able to capture the experimental data qualitatively, it overpredicts the pressure drops experienced by the flow in the two-phase regime. Nevertheless, the model and the experiment show that oscillations are stabilized with increased pressure drop in the two-phase region.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Robust foil regenerator flow loss and heat transfer tests under oscillating flow condition

A regenerator works as an energy storage component in a Stirling engine. Thus, it is one of the most critical components that makes the Stirling engine highly efficient. Traditionally, the regenerators are made of wire media such as woven screens and random fibers. These wire regenerators experience considerably high flow losses through the regenerator due to the flow separation and the resulting vortices. The high flow losses associated with the flow separation and vortices result in a lower engine efficiency. This research is to test a new robust foil regenerator to investigate its feasibility for free-piston Stirling engine applications. The robust foil regenerator is configured with parallel flow channels and stiffening ribs. Comparing to complex flows patterns in woven screen and random fiber regenerators, the flows in the parallel plates are simple and the flow losses are considerably small, and the heat transfer coefficient is also relatively small. To test the regenerator experimentally, a regenerator test rig was manufactured. To verify the accuracy of the test rig, a woven screen regenerator was made and tested prior to the robust foil regenerator test. The friction factor correlation of the woven screen regenerator shows a good agreement with the published regenerator correlations. The robust foil regenerator tests were conducted under the oscillating flow condition with different Reynolds numbers. The flow losses were measured with dynamic pressure transducers and the friction coefficient was derived from measured pressure drop. The measured temperature difference over the regenerator was used to calculate the heat transfer coefficient and Nusselt number. The figure of merit with two methods of NPH/NTU ratio and j/f ratio was calculated to evaluate the suitability of the robust foil regenerator. The results show that the robust foil regenerator has considerably higher figure of merit and therefore, better performance than other types of regenerator.

42 ENGINEERING↗

Topological features in the ferromagnetic Weyl semimetal CeAlSi: Role of domain walls

In the ferromagnetic (FM) Weyl semimetal CeAlSi both space-inversion and time-reversal symmetries are broken. Our quantum oscillation (QO) data indicate that the FM ordering modifies the Fermi-surface topology and also leads to an unusual drop in the QO amplitude. In the FM phase, we find a pressure-induced suppression of the anomalous and the loop Hall effects. This cannot be explained based on the electronic band structure or magnetic structure, both of which are nearly pressure independent. Instead, we show that a simplified model describing the scattering of Weyl fermions off FM domain walls can potentially explain the observed topological features. Our study highlights the importance of domain walls for understanding transport in FM Weyl semimetals.

36 MATERIALS SCIENCE↗

A Semi-Empirical Correlation for the Onset of Density Wave Oscillations in a Helical Coil Steam Generator

NuScale Power has completed full length helical coil steam generator (HCSG) tests at SIET Laboratories in Piacenza, Italy. The test program included an investigation of the onset and evolution of density wave oscillations (DWO). This paper describes the mechanisms leading to the onset of DWO as inferred from tests performed in the full-height TF-2 counter-flow test facility. This research supports the concept that the onset of DWO is caused by liquid bridging inside the boiling length of the tubes. Using a separate cylinders approximation, a DWO onset correlation is obtained by performing a steady-state momentum balance on the density front created by liquid bridging. This yields a momentum balance equation in terms of a set of dimensionless superficial velocities, a corresponding dimensionless pressure drop term and an average void fraction. Envelope theory is then used to obtain a critical void fraction which is substituted into the dimensionless momentum balance to obtain a DWO onset correlation similar to the Wallis counter-current flooding correlation. A comparison of the DWO onset correlation to the TF-2 DWO experimental data is presented and shows excellent agreement when the average equilibrium vapor quality is greater than 0.2.

Density Wave Oscillations, Helical Coil Steam Gene↗

Growing Pacific Linkage with Western North Atlantic Explosive Cyclogenesis

Abstract Explosive cyclones (ECs), defined as extratropical cyclones that experience normalized pressure drops of at least 24 hPa in 24 h, are impactful weather events in the North Atlantic sector, but year-to-year changes in the frequency and impacts of these storms are sizeable. To analyze the sources of this interannual variability, we track cases of ECs and dissect them into two spatial groups: those that formed near the east coast of North America (coastal) and those in the north central Atlantic (high latitude). The frequency of high-latitude ECs is strongly correlated with the North Atlantic Oscillation, a well-known feature, whereas coastal EC frequency is statistically linked with an atmospheric wave train emanating from the North Pacific in the last 30 years. This wave train pattern of alternating high and low pressure is associated with heightened upper-level divergence and Eady growth rates along the east coast of North America, likely resulting in a stronger correspondence between the atmospheric wave train and coastal EC frequency. Using coupled model experiments, we show that the tropical and North Pacific oceans are an important factor for this atmospheric wave train and the subsequent enhancement of seasonal baroclinicity in the North Atlantic.

58 GEOSCIENCES↗

On discriminating tokamak sawtooth crash models via localized density and temperature measurements

The core electron temperature drops rapidly during the sawtooth crash in tokamak plasmas, which causes heat loss and may lead to fast particle losses or even a disruption. Several models have been proposed for the periodic crash, including the Kadomtsev model with magnetic reconnection and the quasi-interchange model with the growth of higher-mode-number pressure-driven instabilities. 3D MHD simulations were performed for these two models with a goal to develop intuition and to predict qualitatively how different types of sawtooth will appear in various diagnostics. The structures of electron density ne and electron temperature Te show a dominant (1, 1) mode for the Kadomtsev case and a dominant (4, 4) mode for the quasi-interchange case. The oscillations of ne and Te have a positive correlation near the inversion layer for both cases, while their frequencies and amplitudes are different depending on the dominant modes. Particularly, for the Kadomtsev case, we find a relation between the amount of flux reconnected during a sawtooth event and ne or Te oscillations. Therefore, we connect recently developed measurement capabilities for ne and Te to the internal sawtooth behavior. We propose that this method of analysis can help in identifying the type of sawtooth in future experiments augmented by simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Corrected Distortion model for Lagrangian spray simulation of transcritical fuel injection

In this work, we present a detailed implementation and validation of the droplet modeling framework proposed by Dahms and Oefelein (2016) into the engine commercial CFD software CONVERGE using the User Defined Function (UDF) interface. The model accounts for the nonlinear deformation and oscillation experienced by liquid spray droplet injected into high pressure and temperature. Lagrangian spray simulations of Engine Combustion Network (ECN) Spray A are performed. Model validation against standard experimental measurements of liquid velocity, vapor mixture fraction is conducted. To perform more rigorous model validation, new experimental measurements based on Diffused Back Illumination (DBI) are introduced. The new measurements are processed for Projected Liquid Volume (PLV), which offers as close as possible one-to-one model validation for liquid penetration while offering new insights into the spray physics. Comparison with a One-D model based on adiabatic mixing theory by Siebers (1999) and Desantes et al. (2007) are also conducted. Through these model validation exercises, it is shown that the new framework improves liquid-phase penetration predictions, following a tendency for enhanced evaporation, compared to the standard approach for both Reynolds Average Navier Stokes (RANS) and Large Eddy Simulation (LES). Additionally, at the liquid length, maximum mixture fraction values predicted by the new approach are in good agreement those of an adiabatic mixing model. Qualitative analysis of the spray behaviors during the early stage of the injection process reveals that the proposed framework predicts significant increase in droplet evaporation rate with lower drop drag compared to the current standard approach.

42 ENGINEERING↗

Revolutionizing Turbine Cooling with Micro-Architectures Enabled by Direct Metal Laser Sintering

The objective of this research effort was to explore innovative cooling architectures enabled by additive manufacturing techniques for improved turbine cooling performance. The ability to create complex internal geometries was leveraged to better distribute coolant as well as to integrate inherently unstable flow devices to enhance internal and external heat transfer. This was accomplished with a multi-faceted approach including analytical, experimental, and computational components. This final report documents progress during the total 4.25 year effort that was extended (at no additional cost) from the original 3-year cooperative agreement. Prior to starting the project, significant effort was invested in investigating innovative cooling designs from the open literature. When the project started, we quickly down-selected to 4 configurations: impingement jet fluidic oscillators (for internal leading edge cooling), reverse film cooling (for pressure surface), sweeping film cooling jets (for suction surface), and trailing edge slot cooling with microchannels. During the 2nd year, the reverse film cooling design was shown to be sub-optimal and work on that topic was halted. The three remaining technologies were integrated into a large scale nozzle guide vane and installed into a low-speed linear cascade facility for further interrogation. Initial results showed the sweeping film cooling jets (on the suction surface) to be the most promising technology compared to a baseline diffusion shaped film hole (777 design). The benefit was particularly evident at high blowing ratios (>1.5) when the 777 coolant film separated from the downstream surface. Benefits were also evident at elevated freestream turbulence levels. The leading edge cooling with unsteady jets was less effective in terms of peak or average cooling – however it was superior to round hole impingement cooling in terms of spatial uniformity. Finally, the trailing edge cooling design with micro-channels was scrapped in favor of a pinned arrangement with centerbody. During the 3rd year, the same three technologies were integrated into a transonic linear cascade for an assessment of compressibility effects. Again, the sweeping film cooling jets proved superior at high blowing ratios while the unsteady leading edge impingement and trailing edge pin-fins with centerbody designs yielded mixed results. Finally, during the 4th and final year, these 3 technologies were integrated into a direct metal laser sintered (DMLS) nozzle guide vane for testing in a high temperature, transonic annular vane cascade. The facility matches the flow temperature, Mach number, and coolant pressure ratios of an actual gas turbine. Before doing this, an additional series of tests were completed to validate a redesigned trailing edge cooling architecture. This final design included a centerbody with triangular pins between the centerbody and the vane external skin. The majority of these triangular pins are fabricated with a 30% gap to the centerbody – reducing their pressure drop considerably while still providing excellent heat transfer augmentation. This additional test campaign required an additional 3-month extension request to complete testing in the high temperature NGV test facility (Turbine Reacting Flow Rig – TuRFR). Testing of the DMLS vane in TuRFR pitted the 3 innovative cooling technologies against more traditional technologies (shaped 777 film hole, round impingement jet, and full pin arrangement in the trailing edge. The sweeping film cooling jets (on the suction surface) showed approximately 15% improvement in overall effectiveness compared to the 777 film hole while the trailing edge showed up to 20% improvement. The leading edge impingement was disappointing with a substantially lower effectiveness than traditional direct impingement. In summary, the study was successful in demonstrating that DMLS-enabled cooling technologies can yield significant gains in cooling performance.

03 NATURAL GAS↗