Search NASA⌕ Search

SEARCH · Search NASA

Results for “pressure points”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Warm Pressurant Gas Effects on the Static Bubble Point Pressure for Cryogenic LADs

This paper presents experimental results for the liquid hydrogen and nitrogen bubble point tests using warm pressurant gases conducted at the NASA Glenn Research Center. The purpose of the test series was to determine the effect of elevating the temperature of the pressurant gas on the performance of a liquid acquisition device (LAD). Three fine mesh screen samples (325x2300, 450x2750, 510x3600) were tested in liquid hydrogen and liquid nitrogen using cold and warm non-condensable (gaseous helium) and condensable (gaseous hydrogen or nitrogen) pressurization schemes. Gases were conditioned from 0K - 90K above the liquid temperature. Results clearly indicate degradation in bubble point pressure using warm gas, with a greater reduction in performance using condensable over non-condensable pressurization. Degradation in the bubble point pressure is inversely proportional to screen porosity, as the coarsest mesh demonstrated the highest degradation. Results here have implication on both pressurization and LAD system design for all future cryogenic propulsion systems. A detailed review of historical heated gas tests is also presented for comparison to current results.

Warm pressurant gas↗

A Predictive Bubble Point Pressure Model for Porous Liquid Acquisition Device Screens

This article presents a simplified model for porous screen channel liquid acquisition devices based on a maximum bubble point pressure method from Adamson and Gast (1997). To validate the model, three 304 stainless steel (325 × 2300, 450 × 2750, and 510 × 3600) mesh samples were tested in methanol, acetone, isopropyl alcohol, and water. Screen pores are estimated based on analysis from scanning electron microscopy, historical data, and current test data. Results show that the bubble point pressure is proportional to the surface tension of the fluid only when accounting for nonzero contact angles. The previous assumption that bubble point pressure scales inversely with effective pore diameter is shown to be invalid, as the second finest 450 × 2750 produced the highest bubble point of the three screens. The simplified bubble point model can be used to make predictions for any pure fluid when pore diameters are based on bubble point tests and not SEM analysis.

Liquid Acquisition Device↗

Toward Smart, Automated Junctional Tourniquets—AI Models to Interpret Vessel Occlusion at Physiological Pressure Points

Hemorrhage is the leading cause of preventable death in both civilian and military medicine. Junctional hemorrhages are especially difficult to manage since traditional tourniquet placement is often not possible. Ultrasound can be used to visualize and guide the caretaker to apply pressure at physiological pressure points to stop hemorrhage. However, this process is technically challenging, requiring the vessel to be properly positioned over rigid boney surfaces and applying sufficient pressure to maintain proper occlusion. As a first step toward automating this life-saving intervention, we demonstrate an artificial intelligence algorithm that classifies a vessel as patent or occluded, which can guide a user to apply the appropriate pressure required to stop flow. Neural network models were trained using images captured from a custom tissue-mimicking phantom and an ex vivo swine model of the inguinal region, as pressure was applied using an ultrasound probe with and without color Doppler overlays. Using these images, we developed an image classification algorithm suitable for the determination of patency or occlusion in an ultrasound image containing color Doppler overlay. Separate AI models for both test platforms were able to accurately detect occlusion status in test-image sets to more than 93% accuracy. In conclusion, this methodology can be utilized for guiding and monitoring proper vessel occlusion, which, when combined with automated actuation and other AI models, can allow for automated junctional tourniquet application.

60 APPLIED LIFE SCIENCES↗

Identification of pressure points in modern power systems using transfer entropy

Power shortages disrupt daily life, economic activity, and essential services. In modern power systems, weather is an increasingly important driver of reliability: high temperatures raise demand and limit transmission capacity, and calm or cloudy periods reduce wind and solar supply. Using a data-driven analysis, this study identifies grid infrastructure whose operating patterns help predict power shortages. The results show that reliability risks often emerge from interacting stresses across generation, transmission, and demand, rather than from single bottlenecks. By clarifying how system stress propagates through the grid, this diagnostic perspective helps explain why shortages occur under specific conditions and can complement traditional planning and operational tools to support adaptive reliability strategies, targeted monitoring, and coordinated infrastructure investments.

power systems↗

Validation of UARS Microwave Limb Sounder Temperature and Pressure Measurements

The accuracy and precision of the Upper Atmosphere Research Satellite (UARS) Microwave Limb Sounder (MLS) atmospheric temperature and tangent-point pressure measurements are described. Temperatures and tangent- point pressure (atmospheric pressure at the tangent height of the field of view boresight) are retrieved from a 15-channel 63-GHz radiometer measuring O2 microwave emissions from the stratosphere and mesosphere. The Version 3 data (first public release) contains scientifically useful temperatures from 22 to 0.46 hPa. Accuracy estimates are based on instrument performance, spectroscopic uncertainty and retrieval numerics, and range from 2.1 K at 22 hPa to 4.8 K at 0.46 hPa for temperature and from 200 m (equivalent log pressure) at 10 hPa to 300 m at 0.1 hPa. Temperature accuracy is limited mainly by uncertainty in instrument characterization, and tangent-point pressure accuracy is limited mainly by the accuracy of spectroscopic parameters. Precisions are around 1 K and 100 m. Comparisons are presented among temperatures from MLS, the National Meteorological Center (NMC) stratospheric analysis and lidar stations at Table Mountain, California, Observatory of Haute Provence (OHP), France, and Goddard Spaceflight Center, Maryland. MLS temperatures tend to be 1-2 K lower than NMC and lidar, but MLS is often 5 - 10 K lower than NMC in the winter at high latitudes, especially within the northern hemisphere vortex. Winter MLS and OHP (44 deg N) lidar temperatures generally agree and tend to be lower than NMC. Problems with Version 3 MLS temperatures and tangent-point pressures are identified, but the high precision of MLS radiances will allow improvements with better algorithms planned for the future.

Fishbein, E. F.↗

Overview of On-Line Optical Measurements at High Pressure for Flue Gases, Particulates and Acid-dew Point of Pressurized Oxy-Combustion

Optical flow cells are critical measurement interfaces, yet sampling under harsh conditions — high pressure, high temperature, particles, moisture, or corrosive gases — makes it difficult to maintain optical quality without perturbing the measurement. To address this challenge, a new flow cell was developed using a laminar coaxial flow field that separates the purge and sample flows. A dedicated test system was built to evaluate particle size distribution (PSD) measurements using a Malvern Panalytical Insitec analyzer. Results demonstrated that the sample flow alone defines the measurement zone, while the purge flow effectively shields the optical windows from deposition, eliminating sampling bias. The flow cell enables reliable PSD measurement under high pressure and temperature in moist, corrosive environments. As a key demonstration, the instrument was successfully deployed for on-line PSD measurement of flue gas from a 100 kWth pressurized oxy-coal combustor at 15 bara.

Cheng, Mao↗

Aerothermal Heating Predictions for Mars Microprobe

A combination of computational predictions and experimental measurements of the aerothermal heating expected on the two Mars Microprobes during their entry to Mars are presented. The maximum, non-ablating, heating rate at the vehicle's stagnation point (at alpha = 0 degrees) is predicted for an undershoot trajectory to be 194 Watts per square centimeters with associated stagnation point pressure of 0.064 atm. Maximum stagnation point pressure occurs later during the undershoot trajectory and is 0.094 atm. From computations at seven overshoot-trajectory points, the maximum heat load expected at the stagnation point is near 8800 Joules per square centimeter. Heat rates and heat loads on the vehicle's afterbody are much lower than the forebody. At zero degree angle-of-attack, heating over much of the hemi-spherical afterbody is predicted to be less than 2 percent of the stagnation point value. Good qualitative agreement is demonstrated for forebody and afterbody heating between CFD calculations at Mars entry conditions and experimental thermographic phosphor measurements from the Langley 20-Inch Mach 6 Air Tunnel. A novel approach which incorporates six degree-of-freedom trajectory simulations to perform a statistical estimate of the effect of angle-of-attack, and other off-nominal conditions, on heating is included.

Mitcheltree, R. A.↗

Arc Jet Facility Test Condition Predictions Using the ADSI Code

The Aerothermal Design Space Interpolation (ADSI) tool is used to interpolate databases of previously computed computational fluid dynamic solutions for test articles in a NASA Ames arc jet facility. The arc jet databases are generated using an Navier-Stokes flow solver using previously determined best practices. The arc jet mass flow rates and arc currents used to discretize the database are chosen to span the operating conditions possible in the arc jet, and are based on previous arc jet experimental conditions where possible. The ADSI code is a database interpolation, manipulation, and examination tool that can be used to estimate the stagnation point pressure and heating rate for user-specified values of arc jet mass flow rate and arc current. The interpolation is performed in the other direction (predicting mass flow and current to achieve a desired stagnation point pressure and heating rate). ADSI is also used to generate 2-D response surfaces of stagnation point pressure and heating rate as a function of mass flow rate and arc current (or vice versa). Arc jet test data is used to assess the predictive capability of the ADSI code.

fluid dynamics↗

Validation of UARS Microwave Limb Sounder Temperature and Pressure Measurements

The accuracy and precision of the Upper Atmosphere Research Satellite (UARS) Microwave Limb Sounder (MLS) atmospheric temperature and tangent-point pressure measurements are described. Temperatures and tangent-point pressure are retrieved from a 15-channel 63-GHz radiometer measuring O 2 microwave emissions from the stratosphere and mesosphere.

atmospheric↗

Bubble Point Measurements of Three Binary Mixtures of Refrigerants: R-32/1234yf, R-32/1234ze(E), and R-1132a/1234yf

In this article, bubble point pressures of three binary mixtures at two compositions each have been measured utilizing a static method. The mixtures studied were difluoromethane + 2,3,3,3-tetrafluoroprop-1-ene (R-32/1234yf), difluoromethane + (E)-1,3,3,3-tetrafluoroprop-1-ene (R-32/1234ze(E)), and 1,1-difluoroethene + 2,3,3,3-tetrafluoroprop-1-ene (R-1132a/1234yf). For all of the mixtures, the minimum temperature measured was 270 K. The maximum temperatures measured for the R-32/1234ze(E), R-32/1234yf, and R-1132a/1234yf mixtures were 360, 345, and 325 K, respectively. A total of 100 bubble point pressures are reported and compared to available literature data relative to the REFPROP database. Lemmon, E. W. [ NIST Standard Reference Database 23: Reference Fluid Thermodynamic and Transport Properties-REFPROP, 10.0; National Institute of Standards and Technology, Standard Reference Data Program: Gaithersburg, 2018]. Additionally, the bubble point pressures obtained in this study are modeled using the perturbed-chain statistical associating fluid theory (PC-SAFT) equation of state. The PC-SAFT model parameters, as well as deviations of this work and literature data from the model, are reported.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Charge-density-wave quantum critical point under pressure in 2 H -TaSe 2

The presence of a quantum-critical point (QCP) at which a nearby ordered phase is suppressed to zero temperature is often invoked to explain emergent quantum phases, e.g. superconductivity. Yet, identifying a QCP and establishing its correlation with superconductivity remains challenging. Materials featuring charge-density-wave (CDW) order and superconductivity offer a clear scenario as both states can be associated with electron-phonon coupling. Here, we uncover a CDW-QCP and demonstrate its interrelation with superconductivity in the prototypical transition-metal dichalcogenide 2 H -TaSe 2 . We determine the evolution of the CDW state up to and beyond its suppression at the critical pressure p c = 19.9(1) GPa by means of X-ray diffraction and inelastic X-ray scattering measurements providing a full crystallographic refinement of the commensurate CDW superstructure. The pressure-induced CDW-QCP in close vicinity to the maximum superconducting transition temperature. Ab-initio lattice dynamical calculations corroborate that 2 H -TaSe 2 features order-parameter fluctuation enhanced superconductivity and can serve as a paradigm to investigate superconductivity near a CDW-QCP.

critical phenomena↗

EV space suit gloves (passive)

A pair of pressure and thermal insulating overgloves to be used with an Extravehicular (EV) suit assembly was designed, developed, fabricated, and tested. The design features extensive use of Nomex felt materials in lieu of the multiple layer insulation formerly used with the Apollo thermal glove. The glove theoretically satisfies all of the thermal requirements. The presence of the thermal glove does not degrade pressure glove tactility by more than the acceptable 10% value. On the other hand, the thermal glove generally degrades pressure glove mobility by more than the acceptable 10% value, primarily in the area of the fingers. Life cycling tests were completed with minimal problems. The thermal glove/pressure glove ensemble was also tested for comfort; the test subjects found no problems with the thermal glove although they did report difficulties with pressure points on the pressure glove which were independent of the thermal glove.

Fletcher, E. G.↗

Empirical Method to Estimate Hydrogen Embrittlement of Metals as a Function of Hydrogen Gas Pressure at Constant Temperature

High pressure Hydrogen (H) gas has been known to have a deleterious effect on the mechanical properties of certain metals, particularly, the notched tensile strength, fracture toughness and ductility. The ratio of these properties in Hydrogen as compared to Helium or Air is called the Hydrogen Environment Embrittlement (HEE) Index, which is a useful method to classify the severity of H embrittlement and to aid in the material screening and selection for safety usage H gas environment. A comprehensive world-wide database compilation, in the past 50 years, has shown that the HEE index is mostly collected at two conveniently high H pressure points of 5 ksi and 10 ksi near room temperature. Since H embrittlement is directly related to pressure, the lack of HEE index at other pressure points has posed a technical problem for the designers to select appropriate materials at a specific H pressure for various applications in aerospace, alternate and renewable energy sectors for an emerging hydrogen economy. Based on the Power-Law mathematical relationship, an empirical method to accurately predict the HEE index, as a function of H pressure at constant temperature, is presented with a brief review on Sievert's law for gas-metal absorption.

Lee, Jonathan A.↗

Avoided ferromagnetic quantum critical point in pressurized La 5 Co 2 Ge 3

We present the pressure-temperature phase diagram La 5 Co 2 Ge 3 up to ~ 5 GPa, which was constructed from magnetization, resistivity, and specific heat measurements. At ambient pressure, La 5 Co 2 Ge 3 is an itinerant ferromagnet with a Curie temperature T C ~ 4 K. Upon increasing pressure up to ~ 1.7 GPa, T C is suppressed down to ~ 3 K. Upon further increasing pressure, our results suggest that La 5 Co 2 Ge 3 enters a different low-temperature ground state. The corresponding transition temperature T* has a nonmonotonic pressure dependence up to ~ 5 GPa. Our results demonstrate that the ferromagnetic quantum critical point in La 5 Co 2 Ge 3 is avoided by the appearance of a different, likely magnetically ordered, state that has an antiferromagnetic component.

36 MATERIALS SCIENCE↗

Failure Analysis of Nickel-hydrogen Cell Subjected to Simulated Low Earth Orbit Cycling

A nickel-hydrogen cell completed 10,080 simulated low earth orbit charge/discharge cycles at depths-of-discharge ranging from 50 to 80 percent prior to failure. The cell is of the Air Force design, rated at 50 ampere-hours, 8.9 cm (3.5 inches) in diameter. Upon disassembly, the end of the polysulfone core supporting the electrode stack was found to have fractured. This allowed the electrode stack to expand. A massive short was found at the inner diameter of the electrodes centered roughly at plate set 34 to 37 from the positive end of the electrode stack. The damaged area extended through approximately one third of the electrode stack, with the effect becoming progressively less with distance from plate set 34 to 37. Measured thicknesses of the positive plates were significantly greater than the initial specification values. The postulated cause of failure is that positive plate growth caused fracture of the shoulder from the end of the polysulfone core on which the electrodes are mounted. The electrode stack relieved and pressure points were created at the area near the inner diameter of the plates at the tab attachment. A short occurred at a pressure point between opposing plates and propagated to other electrode sets due to thermal and mechanical stresses caused by the short.

Mueller, V. C.↗

Analysis of Screen Channel LAD Bubble Point Tests in Liquid Oxygen at Elevated Temperature

The purpose of this paper is to examine the key parameters that affect the bubble point pressure for screen channel Liquid Acquisition Devices in cryogenic liquid oxygen at elevated pressures and temperatures. An in depth analysis of the effect of varying temperature, pressure, and pressurization gas on bubble point is presented. Testing of a 200 x 1400 and 325 x 2300 Dutch Twill screen sample was conducted in the Cryogenics Components Lab 7 facility at the NASA Glenn Research Center in Cleveland, Ohio. Test conditions ranged from 92 to 130K and 0.138 - 1.79 MPa. Bubble point is shown to be a strong function of temperature with a secondary dependence on pressure. The pressure dependence is believed to be a function of the amount of evaporation and condensation occurring at the screen. Good agreement exists between data and theory for normally saturated liquid but the model generally under predicts the bubble point in subcooled liquid. Better correlation with the data is obtained by using the liquid temperature at the screen to determine surface tension of the fluid, as opposed to the bulk liquid temperature.

Hartwig, Jason↗

Failure Investigation of an Intra-Manifold Explosion in a Horizontally-Mounted 870 lbf Reaction Control Thruster

In June 2010, an 870 lbf Space Shuttle Orbiter Reaction Control System Primary Thruster experienced an unintended shutdown during a test being performed at the NASA White Sands Test Facility. Subsequent removal and inspection of the thruster revealed permanent deformation and misalignment of the thruster valve mounting plate. Destructive evaluation determined that after three nominal firing sequences, the thruster had experienced an energetic event within the fuel (monomethylhydrazine) manifold at the start of the fourth firing sequence. The current understanding of the phenomenon of intra-manifold explosions in hypergolic bipropellant thrusters is documented in literature where it is colloquially referred to as a ZOT. The typical ZOT scenario involves operation of a thruster in a gravitational field with environmental pressures above the triple point pressure of the propellants. Post-firing, when the thruster valves are commanded closed, there remains a residual quantity of propellant in both the fuel and oxidizer (nitrogen tetroxide) injector manifolds known as the "dribble volume". In an ambient ground test configuration, these propellant volumes will drain from the injector manifolds but are impeded by the local atmospheric pressure. The evacuation of propellants from the thruster injector manifolds relies on the fluids vapor pressure to expel the liquid. The higher vapor pressure oxidizer will evacuate from the manifold before the lower vapor pressure fuel. The localized cooling resulting from the oxidizer boiling during manifold draining can result in fuel vapor migration and condensation in the oxidizer passage. The liquid fuel will then react with the oxidizer that enters the manifold during the next firing and may produce a localized high pressure reaction or explosion within the confines of the oxidizer injector manifold. The typical ZOT scenario was considered during this failure investigation, but was ultimately ruled out as a cause of the explosion. Converse to the typical ZOT failure mechanism, the failure of this particular thruster was determined to be the result of liquid oxidizer being present within the fuel manifold.

Durning, Joseph G., III↗