Search NASA⌕ Search

SEARCH · Search NASA

Results for “preventable blindness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Optimizing Screening for Preventable Blindness With Head-Mounted Visual Assessment Technology

Age-related macular degeneration (AMD) is a leading cause of blindness and is diagnosed as early-stage or late-stage. Early-stage AMD is usually asymptomatic and entails pigmentary changes of the retina (Ayoub & Patel, 2009). As the disorder progresses, there are atrophic or neovascular changes that distort vision, especially the central visual field (Ayoub & Patel, 2009). There are several genetic and non-genetic risk factors for AMD and no proven therapy to slow or reverse late-stage atrophic AMD, while anti-VEGF has effectively treated late-stage neovascular AMD. Several genes of interest have also been investigated thoroughly thus far in their connection to AMD and the CFH and ARMS2 genes have shown promise in understanding the genetic basis of the disorder (Awh et al., 2013). There are other epigenetic and environmental factors as well including smoking and low antioxidant levels (Cano et al., 2010). Ongoing investigations include antioxidant supplementation and a smoking cessation regimen to reverse early-stage AMD (Cano et al., 2010). Progress in treating AMD as a disorder across its varied stages requires newer therapeutics along with a more detailed understanding of the genetic and cellular pathways of pathophysiology is needed to better counter this prevalent disorder of the eye.

age-related macular degeneration↗

TDCOSMO 2025: Cosmological constraints from strong lensing time delays

We present cosmological constraints from eight strongly lensed quasars (hereafter, the TDCOSMO-2025 sample). Building on previous work, our analysis incorporated new deflector stellar velocity dispersions measured from spectra obtained with the James Webb Space Telescope (JWST), the Keck Telescopes, and the Very Large Telescope (VLT), utilizing improved methods. We used integrated JWST stellar kinematics for five lenses, VLT-MUSE for 2, and resolved kinematics from Keck and JWST for RX J1131−1231. We also considered two samples of non-time-delay lenses: 11 from the Sloan Lens ACS (SLACS) sample with Keck-KCWI resolved kinematics; and four from the Strong Lenses in the Legacy Survey (SL2S) sample. We improved our analysis of line-of-sight effects, the surface brightness profile of the lens galaxies, and orbital anisotropy, and corrected for projection effects in the dynamics. Our uncertainties are maximally conservative by accounting for the mass-sheet degeneracy in the deflectors’ mass density profiles. The analysis was blinded to prevent experimenter bias. Our primary result is based on the TDCOSMO-2025 sample, in combination with Ωm constraints from the Pantheon+ Type Ia supernovae (SN) dataset. In the flat Λ cold dark matter (CDM), we find H0 = 71.6+3.9−3.3 km s−1 Mpc−1. The SLACS and SL2S samples are in excellent agreement with the TDCOSMO-2025 sample, improving the precision on H0 in flat ΛCDM to 4.6%. Using the Dark Energy Survey SN Year-5 dataset (DES-SN5YR) or DESI-DR2 baryonic acoustic oscillations (BAO) likelihoods instead of Pantheon+ yields very similar results. We also present constraints in the open ΛCDM, wCDM, w0waCDM, and wϕCDM cosmologies. The TDCOSMO H0 inference is robust and consistent across all presented cosmological models, and our cosmological constraints in them agree with those from the BAO and SN.Key words: cosmological parameters / cosmology: observations / dark energy / distance scale⋆⋆ Brinson Fellow.⋆⋆⋆ NHFP Einstein Fellow.

Birrer, Simon [SUNY, Stony Brook] (ORCID:000000033↗

TDCOSMO XXIII. Measurement of the Hubble constant from the doubly lensed quasar HE 1104−1805

Time-delay cosmography leverages strongly lensed quasars to measure the Universe’s current expansion rate, H 0 , independently from other methods. The latest TDCOSMO milestone measurement primarily used quadruply lensed quasars for their mass profile constraints. However, doubly lensed quasars, being more abundant and offering precise time delays, could expand the sample by a factor of 5, significantly advancing towards a 1% precision measurement of H 0 . We present the first TDCOSMO analysis of a doubly imaged source, HE 1104−1805, including the measurement of the four necessary ingredients. First, by combining 17 years of data from the SMARTS, Euler, and WFI telescopes, we measured a time delay of 176.3 +11.4 −10.3 days. Second, using MUSE data, we extracted stellar velocity dispersion measurements in three radial bins with 5% to 13% precision. Third, employing F160W HST imaging for lens modelling and marginalising over various modelling choices, we measured the Fermat potential difference between the images. Fourth, using wide-field imaging, we measured the convergence added by objects not included in the lens modelling. By combining these four ingredients, we measured the time delay distance and the angular diameter distance to the deflector, favouring a power-law mass model over a baryonic and dark matter composite model. The measurement was performed blindly to prevent experimenter bias and resulted in a Hubble constant of H 0 = +5.8 −5.0 × λ int km s −1 Mpc −1 , where λ int is the internal mass sheet degeneracy parameter. This is in agreement with the TDCOSMO-2025 milestone and its precision for λ int = 1 is comparable to that obtained with the best-observed quadruply lensed quasars (4–6%). This work is a stepping stone towards a precise measurement of H 0 using a large sample of doubly lensed quasars, supplementing the current sample. The next TDCOSMO milestone paper will include this system in its hierarchical analysis, constraining λ int and H 0 jointly with multiple lenses.

cosmological parameters↗

Smokescreen: A Python package for data vector blinding and encryption in cosmological analyses

Smokescreen is an open-source Python library for data-vector concealment (blinding) in cosmological analyses. Data-vector blinding works by applying cosmology-dependent shifts to the observed data vector, moving it away from the true cosmological signal without affecting its statistical properties, so that analysts cannot infer the true result until the analysis is frozen and the blinding is lifted. The package computes these shifts using Firecrown likelihoods applied to data vectors stored in the SACC format, ensuring that the theoretical model used for blinding is identical to that used for inference whilst remaining agnostic to the specific observable being blinded. To prevent accidental unblinding, the original SACC file, containing the true cosmology, is encrypted. Although developed for the Vera C. Rubin Observatory Legacy Survey of Space and Time (LSST), Smokescreen is applicable to any experiment using Firecrown likelihoods and the SACC data format.

Loureiro, Arthur [Stockholm U., OKC; Imperial Coll↗

Application of Rotating Wall Vessel (RWV) Cell Culture for Pancreas Islet Cell Transplantation

Type I insulin-dependent diabetes mellitus (IDDM) remains a major cause of morbidity and mortality in both pediatric and adult populations, despite significant advances in medical management. While insulin therapy treats symptoms of acute diabetes, it fails to prevent chronic complications such as microvascular disease, blindness, neuropathy, and chronic renal failure. Strict control of blood glucose concentrations delays but does not prevent the onset and progression of secondary complications. Although, whole pancreas transplantation restores physiological blood glucose levels, a continuous process of allograft rejection causes vascular and exocrine-related complications. Recent advances in methods for isolation and purification of pancreatic islets make transplantation of islet allografts an attractive alternative to whole pancreas transplantation. However, immunosuppressive drugs are necessary to prevent rejection of islet allografts and many of these drugs are known to be toxic to the islets. Since auto-transplants of isolated islets following total pancreatectomy survive and function in vivo, it is apparent that a major obstacle to successful clinical islet transplantation is the immunogenicity of the islet allografts.

Rutzky, Lynne P.↗

Keyboard With Voice Output

Voice synthesizer tells what key is about to be depressed. Verbal feedback useful for blind operators or where dim light prevents sighted operator from seeing keyboard. Also used where operator is busy observing other things while keying data into control system. Used as training aid for touch typing, and to train blind operators to use both standard and braille keyboards. Concept adapted to such equipment as typewriters, computers, calculators, telephones, cash registers, and on/off controls.

Huber, W. C.↗

A Preliminary Development of The Intelligent Change Detection System (ICDS): Using Machine Learning to Combat Change Blindness in Remote Operation Environments

The emergence of Advance Air Mobility (AAM) will increase the number and types of aerial vehicles operating in shared airspaces, which will subsequently affect the amount of actionable data that ground control station operators (GCSOs) will be expected to manage. In this environment, GCSOs are particularly susceptible to the visual perceptual phenomenon known as change blindness, in which a stimulus undergoes a change without the change being noticed by its observer. A machine agent designed to detect change blindness and mitigate the effects could improve human agent performance in a data-saturated remote operations environment. The objective of this paper is to describe a proof-of-concept system architecture that integrates real-time eye tracking and vehicle telemetry data to prevent human-agent errors resulting from change blindness while operating aircraft from a remote ground control station (GCS).

Real-Time Streaming Data Architecture↗

A Preliminary Development of The Intelligent Change Detection System (ICDS): Using Machine Learning to Combat Change Blindness in Remote Operation Environments

The emergence of Advance Air Mobility (AAM) will increase the number and types of aerial vehicles operating in shared airspaces, which will subsequently affect the amount of actionable data that ground control station operators (GCSOs) will be expected to manage. In this environment, GCSOs are particularly susceptible to the visual perceptual phenomenon known as change blindness, in which a stimulus undergoes a change without the change being noticed by its observer. A machine agent designed to detect change blindness and mitigate the effects could improve human agent performance in a data-saturated remote operations environment. The objective of this paper is to describe a proof-of-concept system architecture that integrates real-time eye tracking and vehicle telemetry data to prevent human-agent errors resulting from change blindness while operating aircraft from a remote ground control station (GCS).

Real-Time Streaming Data Architecture↗

Comparison of efficacy of ginger with various antimotion sickness drugs

Ginger and several other medications were compared with scopolamine and d-amphetamine for effectiveness in prevention of motion sickness. Methods: Double-blind techniques were used. The subjects were given the medications two hours before they were rotated in a chair making head movements until a symptom total short of vomiting was reached. Standardized N.A.S.A. techniques were used for speed of rotation and end-point of motion sickness. Results: The three doses of ginger were all at the placebo level of efficacy. Amitriptyline, ethopropazine and trihexyphenidyl increased the tolerated head movements but the increase was not statistically significant. Significant levels of protection were produced by dimenhydrinate, promethazine, scopolamine and d-amphetamine. Protection was further increased by combination of these latter drugs with d-amphetamine. Efficacy was greatest as the dose was increased. Conclusions: The medication of choice in this study was scopolamine 0.6 mg with d-amphetamine 10 mg. This combination provided good protection with acceptable side effects.

Non-NASA Center↗

TDCOSMO - XVI. Measurement of the Hubble constant from the lensed quasar WGD 2038–4008

Time-delay cosmography is a powerful technique to constrain cosmological parameters, particularly the Hubble constant (H0). The TDCOSMO Collaboration is performing an ongoing analysis of lensed quasars to constrain cosmology using this method. In this work, we obtain constraints from the lensed quasar WGD 2038−4008 using new time-delay measurements and previous mass models by TDCOSMO. This is the first TDCOSMO lens to incorporate multiple lens modeling codes and the full time-delay covariance matrix into the cosmological inference. The models are fixed before the time delay is measured, and the analysis is performed blinded with respect to the cosmological parameters to prevent unconscious experimenter bias. We obtain DΔ t = 1.68−0.38+0.40 Gpc using two families of mass models, a power-law describing the total mass distribution, and a composite model of baryons and dark matter, although the composite model is disfavored due to kinematics constraints. In a flat ΛCDM cosmology, we constrain the Hubble constant to be H0 = 65−14+23 km s−1 Mpc−1. The dominant source of uncertainty comes from the time delays, due to the low variability of the quasar. Future long-term monitoring, especially in the era of the Vera C. Rubin Observatory’s Legacy Survey of Space and Time, could catch stronger quasar variability and further reduce the uncertainties. This system will be incorporated into an upcoming hierarchical analysis of the entire TDCOSMO sample, and improved time delays and spatially-resolved stellar kinematics could strengthen the constraints from this system in the future.Key words: gravitational lensing: strong / cosmological parameters / distance scale⋆ Corresponding author; kcwong19@gmail.com.⋆⋆ NHFP Einstein fellow.

79 ASTRONOMY AND ASTROPHYSICS↗

Low-dosage micronized 17 beta-estradiol prevents bone loss in postmenopausal women

With the use of a double-blind, randomized, dose-ranging design, we tested during an 18-month period the degree of protection against postmenopausal bone loss afforded by micronized 17 beta-estradiol in dosages of 0.5, 1.0, and 2.0 mg. All subjects received supplementation to ensure a minimum of 1500 mg calcium daily. Fifty-one subjects completed at least 1 year of follow-up bone density measurements by quantitative computed tomography and by single- and dual-photon absorptiometry. In the placebo group spinal trabecular bone density decreased 4.9% annually (p less than 0.001), whereas in those taking micronized 17 beta-estradiol bone density tended to increase (annual increases of 0.3% in the 0.5 mg micronized 17 beta-estradiol group, 1.8% in the 1.0 mg micronized 17 beta-estradiol group, and 2.5% in the 2.0 mg micronized 17 beta-estradiol group). After completing the double-blind phase, 41 subjects completed an additional 18 months of follow-up while taking 1.0 mg micronized 17 beta-estradiol. During this time one third of the subjects were randomly assigned to discontinue calcium supplements. Among those who previously received placebo, trabecular bone density increased 4.3% annually, whereas among those who had used micronized 17 beta-estradiol, trabecular bone density response was inversely related to the dosage previously used. Additionally and independently, the level of calcium intake showed a statistically significant correlation with the change in spinal trabecular bone density (r = 0.37, p = 0.02). We conclude that micronized 17 beta-estradiol has a continuous skeletal dose-response effect in the range of 0.5 to 2.0 mg and that calcium intake positively modifies the skeletal response to 1.0 mg micronized 17 beta-estradiol.

Randomized Controlled Trial↗

Prevention of experimental motion sickness by scopolamine absorbed through the skin

A double-blind placebo-controlled study compared the efficacy of the antimotion sickness drug scopolamine when administered by oral or transdermal routes. A secondary purpose was to extend our bioassay involving fixed-dose combinations of the homergic drugs promethazine and ephedrine. After receiving 12 apparently identical drug-placebo treatments, eight normal male students were exposed in a slow rotation room to stressful accelerations generated by their execution of 40 head movements out of the plane of the room's rotation at 1 rpm and at 1-rpm increments until either symptoms were experienced (just short of frank motion sickness) or the 27-rpm ceiling on the test was reached. Efficacy of a drug was defined in terms of the placebo-range and categorized as beneficial, inconsequential, or detrimental. The only detrimental effect was with scopolamine given orally. It is concluded that the advantages of the transdermal scopolamine, which include minimal side effects and prolonged effectiveness, deserve full exploitation.

Graybiel, A.↗

Evaluation of Intranasal Scopolamine for the Prevention of Wave Motion Induced Motion Sickness While Maintaining Performance on Operationally Relevant Tasks

Motion sickness represents one of the greatest clinical challenges impacting crew activities during and following g-transitions. Our overall goal is to characterize the effectiveness of motion sickness countermeasures during controlled laboratory experiments using capsule wave motion simulation and during field testing in operational environments. This laboratory study focused on prevention of motion sickness using intranasal scopolamine using a double-blinded repeated measures design in 30 subjects (19M, 11F). Intranasal scopolamine was provided by Defender Pharmaceuticals, Inc. (DPI-386 Nasal Gel, referred to as Inscop) self-administered by a nasal pump (Aptar Pharma) that delivers 0.4 mg dose (0.2 mg / nostril). During each session, subjects were exposed to complex wave motion on a six degree-of-freedom platform that included pitch, roll and heave at provocative stimulus frequencies (0.1-0.25 Hz) while seated in an illuminated cabin deprived of external visual cues. Motion sickness symptoms were compared across treatment and placebo control sessions counterbalanced across subjects and separated by at least one week. The time-to-motion sickness endpoint was based on severe malaise, defined as symptom score of ≥8 points using the Pensacola Diagnostic Index [1]. The bioavailability of scopolamine for each session was estimated from plasma concentrations obtained every 15 min[2]. Side effects during the treatment session were minimal, and performance was not impaired on a test battery including motion perception tracking, tablet-based eye-hand coordination and psychomotor vigilance testing. The plasma concentration remained near-peak levels throughout the 45 min motion sickness testing for most subjects. The percentile ranking on the Motion Sickness Susceptibility Questionnaire [MSSQ, 3]was moderately correlated with the motion sickness time-to-endpoint during the placebo control session (rho = –0.3, p=0.056). Seventeen subjects did not reach an endpoint during their placebo session and were eliminated from subsequent analysis. Another subject was excluded due to insufficient plasma concentration during the treatment session. For the remaining 12 subjects, the change in time-to-motion sickness endpoint between placebo and treatment sessions was moderately correlated with plasma concentration (rho =0.48, p = 0.056), improving on average 4.4 ± 18.4 min, mean ± std with Inscop versus placebo. Our results are consistent with previous findings that intranasal delivery of scopolamine can be effective at reducing motion sickness symptoms with minimal cognitive or sedative side effects. Future work is needed to optimize the delivery of Inscop for rescue (treatment) of symptoms following g-transitions as one of the key advantages of this formulation is self-administration in a suited environment. We will also explore how the combination of Inscop with non-pharmaceutical sensory aids, e.g., vibrotactile feedback of Earth vertical, may further mitigate motion sickness and improve task performance.

S J Wood↗

Evaluating a Commercial Dynamic Line Rating Software with the National PMU Dataset

To accelerate the development of data-driven applications for power systems, the Department of Energy (DOE) supported the collection and curation of a synchrophasor dataset spanning two years of observations from transmission utilities across the US. This National PMU Dataset (NPDS) was anonymized and distributed to awardees of a DOE research grant under nondisclosure agreements (NDAs) but has also been retained at PNNL to enable further research. Agreements with data contributors prevent the data from being shared outside the organization. However, establishing a blind research validation methodology is envisioned to maximize the value proposition of the NPDS. In this validation strategy, researchers may share algorithms/software (potentially as executables to protect intellectual property) with PNNL, and PNNL will share feedback about the software’s performance on subsets of the NPDS. Such a blind methodology ensures that sensitive information about critical infrastructure remains protected, but the value of the NPDS can be extended to research beyond PNNL. Through iterative feedback, the algorithms may be tweaked to address real-world artifacts. As the NPDS data is temporally and geographically diverse, it may capture features absent in smaller datasets used during the development of the algorithm under test. This report presents lessons learned from applying the blind validation methodology to LineID™, a synchrophasor-based dynamic line rating software developed by Topolonet Corporation. Improvements made to the software through iterative feedback, limitations of the validation methodology, as well as how the limitations of the NPDS affected the evaluation process are discussed. Observations indicate that the proposed validation methodology can be valuable for evaluating other tools in the future.

97 MATHEMATICS AND COMPUTING↗

Superelastic Ball Bearings: Materials and Design to Avoid Mounting and Dismounting Brinell Damage in an Inaccessible Press-fit Application-: Detailed Analysis - II

Rolling element bearings utilized in precision rotating machines require proper alignment, preload, and interference fits to ensure overall optimum performance. Hence, careful attention must be given to bearing installation and disassembly procedures to ensure the above conditions are met. Usually, machines are designed in such a way that bearings can be pressed into housings or onto shafts through the races without loading the rolling elements. However, in some instances, either due to limited size or access, a bearing must be installed or removed in such a way that the load path travels through the rolling elements. This can cause high contact stresses between the rolling elements and the races and introduces the potential for Brinell denting of the races. This paper is a companion to the Part I paper by the authors that discusses material selection and the general design philosophy for the bearing. Here, a more in-depth treatment is given to the design of a dent-resistant bearing utilizing a superelastic alloy, 60NiTi, for the races. A common bearing analysis tool based on rigid body dynamics is used in combination with finite element simulations to design the superelastic bearing. The primary design constraints are prevention of denting and avoiding the balls riding over the edge of the race groove during a blind disassembly process where the load passes through the rolling elements. Through an iterative process, the resulting bearing geometry is tailored to improve axial static load capability compared to a deep-groove ball bearing of the same size. The results suggest that careful selection of materials and bearing geometry can enable blind disassembly without damage to the raceways, which is necessary in the current application (a compressor in the International Space Station Environmental Control and Life Support System), and results in potential design flexibility for other applications, especially small machines with miniature bearings.

metals↗

Motorized Beam Alignment of a Commercial X-ray Diffractometer

X-ray diffraction (XRD) is a powerful analysis method that allows researchers to noninvasively probe the crystalline structure of a material. This includes the ability to determine the crystalline phases present, quantify surface residual stresses, and measure the distribution of crystallographic orientations. The Structures and Materials Division at the NASA Glenn Research Center (GRC) heavily uses the on-site XRD lab to characterize advanced metal alloys, ceramics, and polymers. One of the x-ray diffractometers in the XRD lab (Bruker D8 Discover) uses three different x-ray tubes (Cu, Cr, and Mn) for optimal performance over numerous material types and various experimental techniques. This requires that the tubes be switched out and aligned between experiments. This alignment maximizes the x-ray tube s output through an iterative process involving four set screws. However, the output of the x-ray tube cannot be monitored during the adjustment process due to standard radiation safety engineering controls that prevent exposure to the x-ray beam when the diffractometer doors are open. Therefore, the adjustment process is a very tedious series of blind adjustments, each followed by measurement of the output beam using a PIN diode after the enclosure doors are shut. This process can take up to 4 hr to perform. This technical memorandum documents an in-house project to motorize this alignment process. Unlike a human, motors are not harmed by x-ray radiation of the energy range used in this instrument. Therefore, using motors to adjust the set screws will allow the researcher to monitor the x-ray tube s output while making interactive adjustments from outside the diffractometer. The motorized alignment system consists of four motors, a motor controller, and a hand-held user interface module. Our goal was to reduce the alignment time to less than 30 min. The time available was the 10-week span of the Lewis' Educational and Research Collaborative Internship Project (LERCIP) summer internship program and the budget goal was $1200. In this report, we will describe our motorization design and discuss the results of its implementation.

Van Zandt, Noah R.↗

Dynamic Light-Scattering Probe Used for the Very Early Detection of Cataracts and to Measure Response to Therapy (or Treatment)

Half of all blindness worldwide is due to cataracts, and 34 million Americans over the age of 65 have cataracts. This figure is expected to rise to 70 million by the year 2030. Currently, no medical treatment is available to prevent or halt the progression of a cataract; nor is there any way to reverse a cataract once it has been detected by conventional methods. The only known treatment is surgical removal of the lens. It is estimated that over $5 billion will be spent this year for the treatment of cataract patients in the United States alone. According to Carl Kupfer, M.D., former Director of the National Eye Institute at the National Institutes of Health, "A delay in cataract formation of about 10 years would reduce the prevalence of visually disabling cataracts by about 45 percent." However, this vision remains a dream because of the lack of objective methods that can be used to detect cataracts very early and, hence, can be used for screening potential anticataract drugs. This is about to change. The National Eye Institute and NASA entered into a formal interagency agreement in late 1996 to develop and test a dynamic light-scattering (DLS) device to detect the earliest changes due to cataract formation. The new DLS probe developed by Dr. Ansari at the NASA Glenn Research Center is several orders of magnitude more sensitive than conventional clinical systems. This ultrahigh sensitivity enables the probe to detect the onset of a cataract before it has any effect on vision and allows researchers to test the effectiveness of anticataract drugs in reversing cataracts. This device (see the following illustration) was originally designed to study transport phenomena in microgravity fluid physics experiments onboard the space shuttle orbiters and space station. It will be very useful in testing anticataract drugs to halt or reverse the progression of cataracts during longitudinal clinical trials.

Ansari,Rafat R.↗

Blind-Side, High-Temperature Fastener Lock

Formed-in-place staple provides positive mechanical lock. Post-supported, advanced carbon/carbon standoff panels, currently under consideration as alternate thermal protection system for Shuttle orbiter, locking feature applicable to temperatures of 1,600 degrees F (870 degrees C) and higher and employable after panel installed, resulting in blind application. Blind-side locking technique employs wire staple inserted into grooves in post, formed in place by ramped portion of post grooves. This splays out wire ends that move into castellated end of grommet, mechanically locking post and grommet against relative rotation. Splayed ends provide mechanical lock to prevent wire from falling out.

Matza, E. C.↗