Search NASA⌕ Search

SEARCH · Search NASA

Results for “probing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Perspectives in Scanning Probe Microscopy from the 2021 Joint International Scanning Probe Microscopy and Scanning Probe Microscopy on Soft and Polymeric Materials Conference

In March of 2020 we were well on our way to organizing and hosting one of the premier scanning probe microscopy (SPM) conferences in Breckenridge, Colorado, USA. For the first time, the meeting would synergistically combine International Scanning Probe Microscopy (ISPM) and Scanning Probe Microscopy on Soft and Polymeric Materials (SPMonSPM), to increase the breadth of audience expertise and experience. We coined the joint conference iSPM 3 – a moniker we hope will persist in future events. The plan for 2020 iSPM 3 screeched to a halt in mid-March, amidst the COVID-19 pandemic. Luckily, we were able to regroup and reimagine the conference for 2021 as a virtual experience. The conference took place June 28th to July 2nd with a mix of live and pre-recorded content. Spread throughout the week were 4 live panel discussions, 3 plenary talks, 23 invited talks, 75 contributed talks, 15 posters and 3 social events. The technical program represented much of the latest and most impactful research in the field. The panel discussions sought to step back from specific research findings and assess the state of SPM as it pertains to some of the most pressing opportunities and influential successes. The lively discussions painted a vibrant future for SPM in both breadth and detail, and we hope that similar discussion can be a mainstay of future SPM conferences. In this work, we attempt to distill some of that discussion to motivate researchers across the field of SPM in the coming years.

47 OTHER INSTRUMENTATION↗

Development of an immersion fiber optic Raman probe for real-time analysis of molten materials

This study presents an advancement in high-temperature Raman spectroscopy, specifically for analyzing molten materials. It introduces an approach by integrating a fiber-optic Raman probe with a copper block protection system designed to endure extreme thermal conditions. The copper block features an open port designed to accommodate an external telescope with a 3 cm focal length, enabling Raman spectra collection in challenging high-temperature environments. A built-in gas channel ensures a continuous flow of argon gas to prevent flux intrusion. The robust copper block acts as a reliable shield, safeguarding the fiber-optic Raman probe within molten materials. This enhancement maintains the probe's integrity and significantly improves its resilience, making it ideal for rigorous investigations of molten substances. This advancement is particularly relevant in metallurgy, where flux materials impact production quality and efficiency. The ability to acquire Raman signals under elevated thermal conditions offers opportunities for studying molecular dynamics, compositional changes, and chemical interactions within molten substances. This introduced direct immersion probing technique has implications, benefiting both scientific and industrial fields. It holds promise for advancing research and exploration in various contexts, from fundamental scientific inquiries to practical applications in metallurgical processes, where flux materials are critical for optimizing production quality and efficiency. Furthermore, this approach enhances the capabilities of high-temperature Raman spectroscopy, making it a valuable tool for investigating molten materials and their properties in diverse settings.

Argon↗

Experimental studies of the difference between plasma potentials measured by Langmuir probes and emissive probes in presheaths

The plasma potential measured by cylindrical and planar Langmuir probes has been shown to differ from the plasma potential measured by emissive probes in the neighborhood of the presheath near a negatively biased electrode immersed in a weakly collisional low temperature argon plasma. There are two principal results demonstrated in this paper. First, while it is well known that Langmuir probes cannot reliably measure plasma potentials inside of sheaths, results presented here demonstrate that the problem persists in presheaths, the quasineutral plasma bordering sheaths. It is known that emissive probes analyzed in the limit of zero emission accurately measure the plasma potential in the sheath. It is now clear that they are the only known electrostatic probe technique able to measure the plasma potential accurately throughout the presheath. Second, it is shown that the difference between potential measurements made by Langmuir probes and emissive probes in the body of the plasma, farther than a presheath distance from the boundary, is not proportional to T e , as has been previously claimed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Atmospheric entry probes for outer planet exploration. Outer planet entry probe technical summary

The use of unmanned space probes for investigating the conditions existing on and around the outer planets of the solar system is discussed. The subjects included in the report are: (1) the design of a common entry probe for outer planet missions, (2) the significant trades related to the development of a common probe design, (3) the impact of bus selection on probe design, (4) the impact of probe requirements on bus modifications, and (5) the key technology elements recommended for advanced development. Drawings and illustrations of typical probes are included to show the components and systems used in the space probes.

Source record↗

Pressure probe and hot-film probe rsponses to acoustic excitation in mean flow

An experiment was conducted to compare the relative responses of a hot-film probe and a pressure probe positioned in a flow duct carrying mean flow and progressive acoustic waves. The response of each probe was compared with that of a condenser-type microphone flush mounted in the duct wall for flow Mach numbers up to about 0.5. The response of the pressure probe was less than that of the flush-mounted microphone by not more than about 2.1 dB at the highest centerline Mach number. This decreased response of the probe can likely be attributed to flow-induced impedance changes at the probe sensor orifices. The response of the hot-film probe, expressed in terms of fluctuating pressure, was greater than that of the flush-mounted microphone by as much as 6.0 dB at the two higher centerline Mach numbers. Removal of the contribution from fluctuating temperature in the hot-film analytical model greatly improved the agreement between the two transducer responses.

Parrott, T. L.↗

Probing Thermal Transport in Fluidized Bed Using Modulated Photothermal Radiometry

Abstract In concentrated solar power (CSP) applications, fluidized bed is a promising approach for high heat transfer coefficient (HTC) solar receivers and heat exchangers. However, the complexity of multiphase mixing has made it difficult to characterize and analyze the heat transfer mechanism. This paper presents an experimental study on simultaneously characterizing heat transfer in both the near-wall and the bulk regions of a fluidized bed using modulated photothermal radiometry (MPR). The MPR is a non-contact frequency-domain technique using an intensity-modulated laser as the heat source and surface infrared emission as thermometry. The thermal penetration depth of the laser heating is varied by controlling its modulation frequency, and thus the measurement can resolve the near-wall and the bulk thermal resistances. With the MPR technique, we measured fluidized silica sands with a mean size of 164 μm in a vertical channel of 6 mm depth. Our results show that the near-wall thermal resistance is substantially increased with increasing gas velocity, which partially offsets the benefit of higher HTC brought by stronger particle mixing during the fluidization. We also used the MPR to quantify the improvement in particle-wall heat transfer in an inclined channel. We found that an 8° inclination towards the heat exchanging side led to a lower near-wall thermal resistance and a higher HTC at high gas velocities. This work demonstrates that the MPR technique is a useful tool to quantify the important near-wall thermal resistance from a bulk particle bed, which not only advances our understanding of heat transfer in fluidized beds, but may also contribute to the design of fluidized bed heat exchangers with higher HTC.

14 SOLAR ENERGY↗

Soft x-ray absorption spectroscopy and magnetic circular dichroism as operando probes of complex oxide electrolyte gate transistors

Electrolyte-based transistors utilizing ionic liquids/gels have been highly successful in the study of charge-density-controlled phenomena, particularly in oxides. Experimental probes beyond transport have played a significant role, despite challenges in their application in electric double-layer transistors. Here, we demonstrate the application of synchrotron soft x-ray absorption spectroscopy (XAS) and x-ray magnetic circular dichroism (XMCD) as operando probes of the charge state and magnetism in ion-gel-gated ferromagnetic perovskite films. Electrochemical response via oxygen vacancies at positive gate bias in LaAlO 3 (001)/La 0.5 Sr 0.5 CoO 3-δ is used as a test case. XAS/XMCD measurements of 4–25 unit-cell-thick films first probe the evolution of hole doping (from the O K-edge pre-peak) and ferromagnetism (at the Co L-edges), to establish a baseline. Operando soft XAS/XMCD of electrolyte-gated films is then demonstrated, using optimized spin-coated gels with a thickness of ~1 μm and a specific composition. The application of gate voltages up to +4 V is shown to dramatically suppress the O K-edge XAS pre-peak intensity and Co L-edge XMCD, thus enabling the Co valence and ferromagnetism to be tracked upon gate-induced reduction. Soft XAS and XMCD, with appropriate electrolyte design, are thus established to be viable for the operando characterization of electrolyte-gated oxides.

Yu, Biqiong↗

Suppression of MHD modes with active phase-control of probe-injected currents

Abstract Active phase-control of probe-injected current is shown to both suppress and amplify long-wavelength rotating magnetohydrodynamic instabilities in the HBT-EP tokamak. Four probes are connected in quadrature and energized to drive non-axisymmetric currents through the edge of the tokamak, creating magnetic perturbations comparable to previously-studied saturated kink modes or resonant magnetic perturbations that are generated by an external control coil array. Measurements of the magnetic perturbations from the probe-injected currents determine a set of current-carrying helical filaments used to model active feedback control of resistive wall modes. These experiments suggest current-injection feedback may be an effective alternative to external control coils for control of RWMs and other long-wavelength kink-like modes at the edge of tokamaks.

Physics↗

Outer planet entry probe system study. Volume 4: Common Saturn/Uranus probe studies

Results are summarized of a common scientific probe study to explore the atmospheres of Saturn and Uranus. This was a three-month follow-on effort to the Outer Planet Entry Probe System study. The report presents: (1) a summary, conclusions and recommendations of this study, (2) parametric analysis conducted to support the two system definitions, (3) common Saturn/Uranus probe system definition using the Science Advisory Group's exploratory payload and, (4) common Saturn/Uranus probe system definition using an expanded science complement. Each of the probe system definitions consists of detailed discussions of the mission, science, system and subsystems including telecommunications, data handling, power, pyrotechnics, attitude control, structures, propulsion, thermal control and probe-to-spacecraft integration. References are made to the contents of the first three volumes where it is feasible to do so.

Source record↗

High Temperature Ultrasonic Probe and Pulse-Echo Probe Mounting Fixture for Testing and Blind Alignment on Steam Pipes

A high temperature ultrasonic probe and a mounting fixture for attaching and aligning the probe to a steam pipe using blind alignment. The high temperature ultrasonic probe includes a piezoelectric transducer having a high temperature. The probe provides both transmitting and receiving functionality. The mounting fixture allows the high temperature ultrasonic probe to be accurately aligned to the bottom external surface of the steam pipe so that the presence of liquid water in the steam pipe can be monitored. The mounting fixture with a mounted high temperature ultrasonic probe are used to conduct health monitoring of steam pipes and to track the height of condensed water through the wall in real-time.

Bar-Cohen, Yoseph↗

A fixed bias, floating double probe technique with simple Langmuir probe characteristics

A new floating double-probe method is presented which has advantages over other floated-probe systems previously described in literature. The method utilized two electrodes, one of constant area and the other with a variable area. The two-electrode configuration is separated by a fixed bias voltage. The current-voltage characteristics of the new technique, which are generated by varying the area of the one electrode, are identical to those of a simple Langmuir probe, thus coupling all the advantages of a floated-probe system with the simple analysis scheme generally applied to the Langmuir probe for the determination of plasma density and temperature.

Szuszczewicz, E. P.↗

Fixed-bias floating double-probe technique with simple Langmuir-probe characteristics.

A new floating double-probe method is presented which has advantages over other floated-probe systems heretofore described in the literature. The method utilizes two electrodes, one of constant area and the other with a variable area, and the two-electrode configuration is separated by a fixed bias voltage. The current-voltage characteristics of the new technique, which are generated by varying the area of one electrode, are identical to those of a simple Langmuir probe, thus coupling all the advantages of a floated-probe system with the simple analysis scheme generally applied to the Langmuir probe for the determination of plasma density and temperature.

Szuszczewicz, E. P.↗

Evaluation of a flow direction probe and a pitot-static probe on the F-14 airplane at high angles of attack and sideslip

The measurement performance of a hemispherical flow-angularity probe and a fuselage-mounted pitot-static probe was evaluated at high flow angles as part of a test program on an F-14 airplane. These evaluations were performed using a calibrated pitot-static noseboom equipped with vanes for reference flow direction measurements, and another probe incorporating vanes but mounted on a pod under the fuselage nose. Data are presented for angles of attack up to 63, angles of sideslip from -22 deg to 22 deg, and for Mach numbers from approximately 0.3 to 1.3. During maneuvering flight, the hemispherical flow-angularity probe exhibited flow angle errors that exceeded 2 deg. Pressure measurements with the pitot-static probe resulted in very inaccurate data above a Mach number of 0.87 and exhibited large sensitivities with flow angle.

Larson, T. J.↗

Carbon Nanotube Tip Probes: Stability and Lateral Resolution in Scanning Probe Microscopy and Application to Surface Science to Semiconductors

In this paper we present results on the stability and lateral resolution capability of carbon nanotube (CNT) scanning probes as applied to atomic force microscopy (AFM). Surface topography images of ultra-thin films (2-5 nm thickness) obtained with AFM are used to illustrate the lateral resolution capability of single-walled carbon nanotube probes. Images of metal films prepared by ion beam sputtering exhibit grain sizes ranging from greater than 10 nm to as small as approximately 2 nm for gold and iridium respectively. In addition, imaging stability and lifetime of multi-walled carbon nanotube scanning probes are studied on a relatively hard surface of silicon nitride (Si3N4). AFM images Of Si3N4 surface collected after more than 15 hrs of continuous scanning show no detectable degradation in lateral resolution. These results indicate the general feasibility of CNT tips and scanning probe microscopy for examining nanometer-scale surface features of deposited metals as well as non-conductive thin films. AFM coupled with CNT tips offers a simple and nondestructive technique for probing a variety of surfaces, and has immense potential as a surface characterization tool in integrated circuit manufacturing.

Nguyen, Cattien V.↗

Langmuir Probe Distortions and Probe Compensation in an Inductively Coupled Plasma

In many RF discharges, Langmuir probe measurements are usually made against a background of sinusoidal (and not so sinusoidal) fluctuations in the plasma parameters such as the plasma potential (Vp), the electron number density (ne), and the electron temperature (Te). The compensation of sinusoidal fluctuations in Vp has been extensively studied and is relatively well understood. Less attention has been paid to the possible distortions introduced by small fluctuations in plasma density and/or plasma temperature, which may arise in the sheath and pre-sheath regions of RF discharges. Here, we present the results of a model simulation of probe characteristics subject to fluctuations in both Vp and ne. The modeling of probe distortion due to possible fluctuations in Te is less straightforward. A comparison is presented of calculations with experimental measurements using a compensated and uncompensated Langmuir probe in an inductively coupled GEC reference cell plasma, operating on Ar and Ar/CF4 mixtures. The plasma parameters determined from the compensated probe characteristics are compared to previous measurements of others made in similar discharges, and to our own measurements of the average electron density derived from electrical impedance measurements.

Ji, J. S.↗

MISIP: a data standard for the reuse and reproducibility of any stable isotope probing-derived nucleic acid sequence and experiment

DNA/RNA-stable isotope probing (SIP) is a powerful tool to link in situ microbial activity to sequencing data. Every SIP dataset captures distinct information about microbial community metabolism, process rates, and population dynamics, offering valuable insights for a wide range of research questions. Data reuse maximizes the information derived from the labor and resource-intensive SIP approaches. Yet, a review of publicly available SIP sequencing metadata showed that critical information necessary for reproducibility and reuse was often missing. Here, we outline the Minimum Information for any Stable Isotope Probing Sequence (MISIP) according to the Minimum Information for any (x) Sequence (MIxS) framework and include examples of MISIP reporting for common SIP experiments. Our objectives are to expand the capacity of MIxS to accommodate SIP-specific metadata and guide SIP users in metadata collection when planning and reporting an experiment. The MISIP standard requires 5 metadata fields—isotope, isotopolog, isotopolog label, labeling approach, and gradient position—and recommends several fields that represent best practices in acquiring and reporting SIP sequencing data (e.g., gradient density and nucleic acid amount). The standard is intended to be used in concert with other MIxS checklists to comprehensively describe the origin of sequence data, such as for marker genes (MISIP-MIMARKS) or metagenomes (MISIP-MIMS), in combination with metadata required by an environmental extension (e.g., soil). The adoption of the proposed data standard will improve the reuse of any sequence derived from a SIP experiment and, by extension, deepen understanding of in situ biogeochemical processes and microbial ecology.

Simpson, Abigayle↗