Search NASA⌕ Search

SEARCH · Search NASA

Results for “process tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Effect of Microgravity on Material Undergoing Melting and Freezing: the TES Experiment

This experiment is the first to melt and freeze a high temperature thermal energy storage (TES) material under an extended duration of microgravity. It is one of a series to validate an analytical computer program that predicts void behavior of substances undergoing phase change under microgravity. Two flight experiments were launched in STS-62. The first, TES-1, containing lithium fluoride in an annular volume, performed flawlessly in the 22 hours of its operation. Results are reported in this paper. A software failure in TES-2 caused its shutdown after 4 seconds. A computer program, TESSIM, for thermal energy storage simulation is being developed to analyze the phenomena occurring within the TES containment vessel. The first order effects, particularly the surface tension forces, have been incorporated into TESSIM. TESSIM validation is based on two types of results. First is the temperature history of various points of the containment structure, and second, upon return from flight, the distribution of the TES material within the containment vessel following the last freeze cycle. The temperature data over the four cycles showed a repetition of results over the third and fourth cycles. This result is a confirmation that any initial conditions prior to the first cycle had been damped out by the third cycle. The TESSIM simulation showed a close comparison with the flight data. The solidified TES material distribution within the containment vessel was obtained by a tomography imaging process. The frozen material was concentrated toward the colder end of the annular volume. The TESSIM prediction showed the same pattern. With the general agreement of TESSIM and the data, a computerized visual representation can be shown which accurately shows the movement and behavior of the void during the entire freezing and melting cycles.

Namkoong, David↗

Experimental Results from the Thermal Energy Storage-2 (TES-2) Flight Experiment

Thermal Energy Storage-2 (TES-2) is a flight experiment that flew on the Space Shuttle Endeavour (STS-72), in January 1996. TES-2 originally flew with TES-1 as part of the OAST-2 Hitchhiker payload on the Space Shuttle Columbia (STS-62) in early 1994. The two experiments, TES-1 and TES-2 were identical except for the fluoride salts to be characterized. TES-1 provided data on lithium fluoride (LiF), TES-2 provided data on a fluoride eutectic (LiF/CaF2). Each experiment was a complex autonomous payload in a Get-Away-Special payload canister. TES-1 operated flawlessly for 22 hr. Results were reported in a paper entitled, Effect of Microgravity on Materials Undergoing Melting and Freezing-The TES Experiment, by David Namkoong et al. A software failure in TES-2 caused its shutdown after 4 sec of operation. TES-1 and 2 were the first experiments in a four experiment suite designed to provide data for understanding the long duration microgravity behavior of thermal energy storage salts that undergo repeated melting and freezing. Such data have never been obtained before and have direct application for the development of space-based solar dynamic (SD) power systems. These power systems will store energy in a thermal energy salt such as lithium fluoride or a eutectic of lithium fluoride/calcium difluoride. The stored energy is extracted during the shade portion of the orbit. This enables the solar dynamic power system to provide constant electrical power over the entire orbit. Analytical computer codes were developed for predicting performance of a space-based solar dynamic power system. Experimental verification of the analytical predictions were needed prior to using the analytical results for future space power design applications. The four TES flight experiments were to be used to obtain the needed experimental data. This paper will address the flight results from the first and second experiments, TES-1 and 2, in comparison to the predicted results from the Thermal Energy Storage Simulation (TESSIM) analytical computer code. An analysis of the TES-2 data was conducted by Cleveland State University Professor, Mounir Ibrahim. TESSIM validation was based on two types of results; temperature history of various points on the containment vessel and TES material distribution within the vessel upon return from flight. The TESSIM prediction showed close comparison with the flight data. Distribution of the TES material within the vessel was obtained by a tomography imaging process. The frozen TES material was concentrated toward the colder end of the canister. The TESSIM prediction indicated a similar pattern. With agreement between TESSIM and the flight data, a computerized representation was produced to show the movement and behavior of the void during the entire melting and freezing cycles.

Tolbert, Carol↗

Computed Tomography and Thermography Increases CMC Material and Process Development Efficiency and Testing Effectiveness

Nondestructive characterization techniques have been used to steer development and testing of CMCs. Computed tomography is used to determine the volumetric integrity of the CMC plates and components. Thermography is used to determine the near surface integrity of the CMC plates and components. For process and material development, information such as density uniformity, part delamination, and dimensional tolerance conformity is generated. The information from the thermography and computed tomography is correlated and then specimen cutting maps are superimposed on the thermography images. This enables for tighter data and potential explanation of off nominal test data. Examples of nondestructive characterization utilization to make decisions in process and material development and testing are presented.

Effinger, Michael↗

First Stars and Galaxies, the Roadmap Ahead: Observation

A complete observational understanding of the first stars and galaxies will require four facilities: JWST, 30m ground-based telescopes, ALMA, and the SKA. Each provides complementary capabilities. JWST is our best hope for looking to very high redshift. 30m-class ground-based telescopes provide sensitivity to the rest-frame ultraviolet with high-resolution imaging and high-resolution NIR spectroscopy, possibly reaching as far as z approx.15. They will also allow us to study stellar populations in nearby galaxies and examine the fossil record of the first stars. ALMA will image the redshifted dust continuum emission from evolving galaxies out to z approx.10. The SKA will do cosmic tomography, mapping the process of reionization.

Gardner, Jonathan P.↗

Application of Advanced Nondestructive Evaluation Techniques for Cylindrical Composite Test Samples

Two nondestructive methods were applied to composite cylinder samples pressurized to failure in order to determine manufacturing quality and monitor damage progression under load. A unique computed tomography (CT) image processing methodology developed at NASA Glenn Research was used to assess the condition of the as-received samples while acoustic emission (AE) monitoring was used to identify both the extent and location of damage within the samples up to failure. Results show the effectiveness of both of these methods in identifying potentially critical fabrication issues and their resulting impact on performance.

Martin, Richard E.↗

Correlations of Additive Manufacturing Model-Based Process Metrics With Spatter-Induced Porosity in the Powder Bed Fusion-Laser Beam/Metallic Process

Components fabricated using the powder bed fusion laser beam metallic (PBF-LB/M) additive manufacturing (AM) process comprise a multitude of sequential weld passes. Qualifying materials for components in critical applications requires a thorough understanding of pertinent processing-microstructure-property relationships. Porosity defects have a strong adverse effect on the mechanical properties of a material. The morphology of porosity defects created by lack of fusion in PBF-LB/M often exhibit high aspect ratios that can act as stress concentrators and become crack initiation sites. The occurrence of spatter induced porosity is studied using synchronized AM model-based process metrics and porosity measured by high-resolution X-ray computed tomography. A novel AM process metric is introduced to quantify the relative exposure to spatter ejecta impacts and incorporation throughout the sequence of the PBF-LB/M process. Further characterization using optical metallography and scanning electron microscopy indicated that both keyhole and lack of fusion porosity correlated statistically with the spatter ejecta impact field of the PBF-LB/M process. Both keyhole and lack of fusion porosity can be predicted by the spatter exposure process metric, which can be exploited to control the fusion sequence.

Additive Manufacturing↗

X-Ray Computed Tomography: The First Step in Mars Sample Return Processing

The Mars 2020 rover mission will collect and cache samples from the martian surface for possible retrieval and subsequent return to Earth. If the samples are returned, that mission would likely present an opportunity to analyze returned Mars samples within a geologic context on Mars. In addition, it may provide definitive information about the existence of past or present life on Mars. Mars sample return presents unique challenges for the collection, containment, transport, curation and processing of samples [1] Foremost in the processing of returned samples are the closely paired considerations of life detection and Planetary Protection. In order to achieve Mars Sample Return (MSR) science goals, reliable analyses will depend on overcoming some challenging signal/noise-related issues where sparse martian organic compounds must be reliably analyzed against the contamination background. While reliable analyses will depend on initial clean acquisition and robust documentation of all aspects of developing and managing the cache [2], there needs to be a reliable sample handling and analysis procedure that accounts for a variety of materials which may or may not contain evidence of past or present martian life. A recent report [3] suggests that a defined set of measurements should be made to effectively inform both science and Planetary Protection, when applied in the context of the two competing null hypotheses: 1) that there is no detectable life in the samples; or 2) that there is martian life in the samples. The defined measurements would include a phased approach that would be accepted by the community to preserve the bulk of the material, but provide unambiguous science data that can be used and interpreted by various disciplines. Fore-most is the concern that the initial steps would ensure the pristine nature of the samples. Preliminary, non-invasive techniques such as computed X-ray tomography (XCT) have been suggested as the first method to interrogate and characterize the cached samples without altering the materials [1,2]. A recent report [4] indicates that XCT may minimally alter samples for some techniques, and work is needed to quantify these effects, maximizing science return from XCT initial analysis while minimizing effects.

Welzenbach, L. C.↗

Database tomography for commercial application

Database tomography is a method for extracting themes and their relationships from text. The algorithms, employed begin with word frequency and word proximity analysis and build upon these results. When the word 'database' is used, think of medical or police records, patents, journals, or papers, etc. (any text information that can be computer stored). Database tomography features a full text, user interactive technique enabling the user to identify areas of interest, establish relationships, and map trends for a deeper understanding of an area of interest. Database tomography concepts and applications have been reported in journals and presented at conferences. One important feature of the database tomography algorithm is that it can be used on a database of any size, and will facilitate the users ability to understand the volume of content therein. While employing the process to identify research opportunities it became obvious that this promising technology has potential applications for business, science, engineering, law, and academe. Examples include evaluating marketing trends, strategies, relationships and associations. Also, the database tomography process would be a powerful component in the area of competitive intelligence, national security intelligence and patent analysis. User interests and involvement cannot be overemphasized.

Kostoff, Ronald N.↗

NDE Software Developed at NASA Glenn Research Center

NASA Glenn Research Center has developed several important Nondestructive Evaluation (NDE) related software packages for different projects in the last 10 years. Three of the software packages have been created with commercial-grade user interfaces and are available to United States entities for download on the NASA Technology Transfer and Partnership Office server (https://sr.grc.nasa.gov/). This article provides brief overviews of the software packages.

image processing↗

A Procedure to Quantify Interlaminar Damage in Refractory Composites by In-Situ Micro-X-Ray Computed Tomography

Refractory composites are relevant for hot-structure applications on re-entry vehicles. To develop optimized high-performance hot structures, accurate material property data is required. Material properties that often limit design in two-dimensional (2-D) composites are interlaminar strengths. A better understanding of the failure mechanisms for interlaminar shear (ILS), interlaminar tension (ILT), and curved-beam interlaminar tension (CB-ILT) tests can provide insight on improving the design and fabrication of refractory composites. In-situ tests were performed to capture the progressive failure in American Society for Testing and Materials (ASTM) sized ILS (ASTM D3846), ILT (ASTM D7291), and CB-ILT (ASTM D6415) specimens. Before measuring internal damage of refractory composites specimens, the methodology of the test setup warrants a complete and thorough discussion. Detail on the test procedure, test stand design, micro-x-ray computed tomography (CT) configuration, data processing, and CT system uncertainty is discussed. Through keeping the many parameters of the CT system consistent, the uncertainty of the CT system was minimized, optimizing the quality of measurements. The overall quality of a CT scan can be quantified by three metrics: voxel resolution, minimal voxel resolution feature detection, and directional variability. A better understanding of the progressive failure mechanisms of refractory composites is provided by the results of both the present discussion and the one found in the accompanying paper titled “Analysis of Interlaminar Damage in Refractory Composites by In-Situ Micro-X-Ray Computed Tomography”.

In-situ micro-x-ray CT↗

In-Situ Observations of Longitudinal Compression Damage in Carbon-Epoxy Cross Ply Laminates Using Fast Synchrotron Radiation Computed Tomography

The role of longitudinal compressive failure mechanisms in notched cross-ply laminates is studied experimentally with in-situ synchrotron radiation based computed tomography. Carbon/epoxy specimens loaded monotonically in uniaxial compression exhibited a quasi-stable failure process, which was captured with computed tomography scans recorded continuously with a temporal resolutions of 2.4 seconds and a spatial resolution of 1.1 microns per voxel. A detailed chronology of the initiation and propagation of longitudinal matrix splitting cracks, in-plane and out-of-plane kink bands, shear-driven fiber failure, delamination, and transverse matrix cracks is provided with a focus on kink bands as the dominant failure mechanism. An automatic segmentation procedure is developed to identify the boundary surfaces of a kink band. The segmentation procedure enables 3-dimensional visualization of the kink band and conveys the orientation, inclination, and spatial variation of the kink band. The kink band inclination and length are examined using the segmented data revealing tunneling and spatial variations not apparent from studying the 2-dimensional section data.

Bergan, Andrew C.↗

Modeling of polychromatic attenuation using computed tomography reconstructed images

This paper presents a procedure for estimating an accurate model of the CT imaging process including spectral effects. As raw projection data are typically unavailable to the end-user, we adopt a post-processing approach that utilizes the reconstructed images themselves. This approach includes errors from x-ray scatter and the nonidealities of the built-in soft tissue correction into the beam characteristics, which is crucial to beam hardening correction algorithms that are designed to be applied directly to CT reconstructed images. We formulate this approach as a quadratic programming problem and propose two different methods, dimension reduction and regularization, to overcome ill conditioning in the model. For the regularization method we use a statistical procedure, Cross Validation, to select the regularization parameter. We have constructed step-wedge phantoms to estimate the effective beam spectrum of a GE CT-I scanner. Using the derived spectrum, we computed the attenuation ratios for the wedge phantoms and found that the worst case modeling error is less than 3% of the corresponding attenuation ratio. We have also built two test (hybrid) phantoms to evaluate the effective spectrum. Based on these test phantoms, we have shown that the effective beam spectrum provides an accurate model for the CT imaging process. Last, we used a simple beam hardening correction experiment to demonstrate the effectiveness of the estimated beam profile for removing beam hardening artifacts. We hope that this estimation procedure will encourage more independent research on beam hardening corrections and will lead to the development of application-specific beam hardening correction algorithms.

NASA Discipline Musculoskeletal↗

Diagnostic imaging applications; Proceedings of the Meeting, Amsterdam, Netherlands, October 8, 9, 1984

It is more important than ever that engineers have an understanding of the future needs of clinical and research medicine, and that physicians know somthing about probable future developments in instrumentation capabilities. Only by maintaining such a dialog can the most effective application of technological advances to medicine be achieved. This workshop attempted to provide this kind of information transfer in the limited field of diagnostic imaging. Biomedical research at the Jet Propulsion Laboratory is discussed, taking into account imaging results from space exploration missions, as well as biomedical research tasks based in these technologies. Attention is also given to current and future indications for magnetic resonance in medicine, high speed quantitative digital microscopy, computer processing of radiographic images, computed tomography and its modern applications, position emission tomography, and developments related to medical ultrasound.

Beckenbach, E. S.↗

Assessment of Segmentation-Induced Deviations of Porosity Metrics in Powder Bed Fusion Additively Manufactured Components

Post processing X-ray computational tomography (CT) inspection data for additively manufactured (AM) components can induce deviations in defect quantification, affecting subsequent fatigue and failure predictions. To assess the influence and potential impact of segmentation-induced measurement deviations, this paper applies several segmentation techniques to X-ray CT data for powder bed fusion Ti-6Al-4V specimens exhibiting porosity conditions. X-ray CT reconstructions were segmented with varying techniques including Otsu’s thresholding, random forest, k-nearest neighbors, and the multilayer perceptron. Metrics such as pore size and global porosity were compared for internal validity. Then, top-down X-ray CT measurements of surface-breaking porosity were compared to optical profilometry for cross-validation.

Data fusion↗

X-Ray Computed Tomography of Apollo Drive Tube 73001 as Part of the Apollo Next Generation Sample Analysis Program

Introduction: Starting in 2019, the Apollo Next Generation Sample Analysis (ANGSA) Program has enabled consortium studies of specially curated Apollo samples that were previously unstudied (or under studied). This program was intended as a participating scientist program for these Apollo samples, as well as a preparation for upcoming lunar sample return missions (e.g., Artemis). The work began with studies of unsealed core tube 73002 [1,2] that is the upper ~35 cm of an Apollo 17 double drive tube (~70 cm total depth) collected on the landslide deposit near Lara Crater at Station 3 in the Taurus Littrow Valley. More recently the program extended to the study of a variety of frozen Apollo 17 samples [3], as well as the gas extraction [4] and dissection [5] of 73001, the lower half of the station 3 double drive tube. Sample 73001 was sealed under vacuum on the Moon in a Core Sample Vacuum Container (CSVC). In this abstract we will examine the role of X-ray Computed Tomography (XCT) during the preliminary examination process for sealed core 73001, including: (1) engineering scans to aid in understanding the gas extraction process, (2) whole-core scanning prior to opening to inform extrusion and dissection work, and (3) individual particle scanning to characterize rock fragment lithologies for follow on studies. Methodology: Sample 73001 is a 33 cm long, 4 cm diameter regolith sample collected inside a lunar drive tube (~1 mm aluminum walls). That drive tube was sealed inside a 0.5 mm thick stainless steel (SS) CSVC. XCT scans for engineering purposes were done on the Nikon XTH 320 system at Johnson Space Center using the 225 kV multi-metal reflection source at 215 kV, 179 A, and a 38.49 m voxel size. Individual >4 mm particles separated from the core during processing (then triply sealed in Teflon bags) were also scanned at JSC using the 180 kV source at 90 kV, 33 A, and a 2.98 – 10.65 m voxel size. Whole-core scans were done at the University of Texas High-Resolution X-ray Computed Tomography Facility (UTCT) on the 225 kV reflection source on the North Star Imaging cabinet XCT system. These scans included: (1) a series of 9 overlapping super-resolution scans each covering a ~4 cm length of the tube at 190 kV, 180 µA, and a 12.9 µm voxel size and (2) a lower resolution continuous helical scan of the entire core at 190 kV, 180 µA, and a 51.8 µm voxel size. Progress and Results: Before piercing and extracting the gas from sample 73001, an XCT scan of the bottom portion of the CSVC was used to confirm the location of the Teflon cap on the inner drive tube and whether there was an “air” gap between the Teflon cap and the CSVC. This was to ensure the Teflon cap (which immobilized the soil inside the drive tube) was not accidentally pierced during gas extraction. Similarly, after piercing, the bottom and top portions of the CSVC were scanned in order to capture engineering knowledge about the results of the piercing process, as well as the metal knife edge vacuum seal (SS into an In-Ag alloy). Both scans will provide constraints on future work of this type, both for the design of tools used on the lunar surface during Artemis, as well as how we open future samples of this type. An unexpected finding from these engineering scans was that the device in the drive tube that immobilizes the regolith (the keeper) was not seated in the tube properly. This meant that (1) the drive tube could not be removed from the CSVC for the trip to UTCT, and (2) the procedure for opening and extruding the drive tube had to be modified. Had either of these things not been known prior to opening the CSVC, it could have led to an inability to XCT scan the whole core at high resolution and/or potential disruption of the core stratigraphy during extrusion. At UTCT, the entire length of the core was scanned at high resolution (12.9 microns per voxel). This scan serves multiple purposes: (1) A lower resolution (and uncorrected) version of these scans stitched together was used to help inform the processors of potential pitfalls during extrusion and dissection (voids, angular fragments at the edges of the sample, etc.); and (2) the full resolution corrected data will serve as the permanent in situ record of the stratigraphy of the sample and will enable future researchers to perform a variety of analyses. All 121 >4 mm particles separated during dissection pass 1 of sample 73001 have been individually scanned. These scans clearly show the lithology of each particle while keeping the particles in pristine condition (they are individually triply bagged in Teflon within our N2 purged processing cabinets). Because of the dust adhering to particle exteriors, it would otherwise be impossible to determine lithologies in a non-contaminating way. Thus far the types of lithologies seen in sample 73001 (e.g., regolith breccias, impact-melt breccias, agglutinates, and bas-alts) are similar to those previously identified in sample 73002 [2]. By the time of the meeting, all particles from all 3 dissection passes will have been scanned and statistics on the different lithologies in 73001 compiled. References: [1] Shearer et al. (2020) 51st LPSC, abstract 1181. [2] Zeigler et al. (2020) 51st LPSC, abstract 3023. [3] Kent et al. (2022) This Volume. [4] McDonald et al. (2022) European Lunar Symposium. [5] Gross et al (2022) This volume.

Moon↗

X-Ray Computed Tomography During Preliminary Examination of Apollo Drive Tube 73001

Introduction: Starting in 2019, the Apollo Next Generation Sample Analysis (ANGSA) Program has enabled consortium studies of specially curated Apollo samples that were previously unstudied (or under studied). This began with unsealed core tube 73002 [1,2] that is the upper part of a station 3 double drive tube. More recently the pro-gram extended to the study of a variety of frozen Apollo 17 samples [3], as well as the gas extraction [4] and dis-section [5] of 73001, the lower half of the station 3 double drive tube, that was sealed under vacuum on the Moon. In this abstract we will examine the role of X-ray Computed Tomography (XCT) during the preliminary examination process for sealed core 73001, including: (1) engineering scans to aid in understanding the gas extraction process, whole-core scanning prior to opening to inform extrusion and dissection work, and (3) individual particle scanning to characterize rock fragment lithologies for follow on studies. Methodology: Sample 73001 is a 33 cm long, 4 cm diameter regolith sample collected inside a drive tube (~1 mm aluminum walls). That drive tube was sealed inside a 0.5 mm thick stainless steel (SS) Core Sample Vacuum Container (CSVC). XCT scans for engineering purposes were done on the Nikon XTH 320 system at Johnson Space Center using the 225 kV multi-metal reflection source at 215 kV, 179 A, and a 38.49 m voxel size. Individual >4 mm particles separated from the core during processing (then triply sealed in Teflon bags) were also scanned at JSC using the 180 kV source at 90 kV, 33 A, and a 2.98 – 10.65 m voxel size. Whole-core scans were done at the University of Texas High-Resolution X-ray Computed Tomography Facility (UTCT) on the 225 kV reflection source on the North Star Imaging cabinet XCT system. These scans included: (1) a series of 9 overlapping super-resolution scans each covering a ~4 cm length of the tube at 190 kV, 180 µA, and a 12.9 µm voxel size and (2) a lower resolution continuous helical scan of the entire core at 190 kV, 180 µA, and a 51.8 µm voxel size. Progress and Results: Before piercing and extracting the gas from sample 73001, an XCT scan of the bottom portion of the CSVC was used to confirm the location of the Teflon cap on the inner drive tube, to ensure it was not accidentally pierced during gas extraction. Similarly, after piercing, the bottom and top portions of the CSVC were scanned in order to capture engineering knowledge about the results of the piercing process, as well as the metal knife edge vacuum seal (SS into In-Ag alloy). Both scans will provide constraints on future work of this type, particularly for samples collected during the Artemis mission. Another finding from these "engineering" scans was that the device in the drive tube that immobilizes the regolith (the keeper) was not seated in the tube properly. This meant that (1) the drive tube could not be removed from the CSVC for the trip to UTCT, and (2) the procedure for opening and extruding the drive tube had to be modified. Had either of these things not been known prior to opening the CSVC, it could have led to an inability to XCT scan the whole core at high resolution and/or potential disruption of the core stratigraphy during extrusion. At UTCT, the entire length of the core was scanned at high resolution (12.9 microns per voxel). This scan serves multiple purposes: (1) A lower resolution (and uncorrected) version of these scans stitched together was used to help inform the processors of potential pitfalls during extrusion and dissection; and (2) the full resolution corrected data will serve as the permanent in situ record of the stratigraphy of the sample and will enable future researchers to perform a variety of analyses. So far, 92 of the 121 >4 mm particles separated during dissection pass 1 of sample 73001 have been individually scanned. These scans clearly show the lithology of each particle while keeping the particles in pristine condition. Because of the dust adhering to particle exteriors it would otherwise be impossible to determine lithologies in a non-contaminating way. Thus far the types of lithologies seen in sample 73001 (e.g., regolith breccias, impact-melt breccias, agglutinates, and basalts) are similar to those previously identified in sample 73002 [2]. By the time of the meeting, all particles from all 3 dissection passes will have been scanned and statistics on the different lithologies in 73001 compiled. References: [1] Shearer et al. (2020) 51st LPSC, abstract 1181. [2] Zeigler et al. (2020) 51st LPSC, abstract 3023. [3] Kent et al. (2022) This Volume. [4] McDonald et al. (2022) European Lunar Symposium. [5] Gross et al (2022) This volume.

Moon↗

GMI-IPS: Python Processing Software for Aircraft Campaigns

NASA's Atmospheric Tomography Mission (ATom) seeks to understand the impact of anthropogenic air pollution on gases in the Earth's atmosphere. Four flight campaigns are being deployed on a seasonal basis to establish a continuous global-scale data set intended to improve the representation of chemically reactive gases in global atmospheric chemistry models. The Global Modeling Initiative (GMI), is creating chemical transport simulations on a global scale for each of the ATom flight campaigns. To meet the computational demands required to translate the GMI simulation data to grids associated with the flights from the ATom campaigns, the GMI ICARTT Processing Software (GMI-IPS) has been developed and is providing key functionality for data processing and analysis in this ongoing effort. The GMI-IPS is written in Python and provides computational kernels for data interpolation and visualization tasks on GMI simulation data. A key feature of the GMI-IPS, is its ability to read ICARTT files, a text-based file format for airborne instrument data, and extract the required flight information that defines regional and temporal grid parameters associated with an ATom flight. Perhaps most importantly, the GMI-IPS creates ICARTT files containing GMI simulated data, which are used in collaboration with ATom instrument teams and other modeling groups. The initial main task of the GMI-IPS is to interpolate GMI model data to the finer temporal resolution (1-10 seconds) of a given flight. The model data includes basic fields such as temperature and pressure, but the main focus of this effort is to provide species concentrations of chemical gases for ATom flights. The software, which uses parallel computation techniques for data intensive tasks, linearly interpolates each of the model fields to the time resolution of the flight. The temporally interpolated data is then saved to disk, and is used to create additional derived quantities. In order to translate the GMI model data to the spatial grid of the flight path as defined by the pressure, latitude, and longitude points at each flight time record, a weighted average is then calculated from the nearest neighbors in two dimensions (latitude, longitude). Using SciPya's Regular Grid Interpolator, interpolation functions are generated for the GMI model grid and the calculated weighted averages. The flight path points are then extracted from the ATom ICARTT instrument file, and are sent to the multi-dimensional interpolating functions to generate GMI field quantities along the spatial path of the flight. The interpolated field quantities are then written to a ICARTT data file, which is stored for further manipulation. The GMI-IPS is aware of a generic ATom ICARTT header format, containing basic information for all flight campaigns. The GMI-IPS includes logic to edit metadata for the derived field quantities, as well as modify the generic header data such as processing dates and associated instrument files. The ICARTT interpolated data is then appended to the modified header data, and the ICARTT processing is complete for the given flight and ready for collaboration. The output ICARTT data adheres to the ICARTT file format standards V1.1. The visualization component of the GMI-IPS uses Matplotlib extensively and has several functions ranging in complexity. First, it creates a model background curtain for the flight (time versus model eta levels) with the interpolated flight data superimposed on the curtain. Secondly, it creates a time-series plot of the interpolated flight data. Lastly, the visualization component creates averaged 2D model slices (longitude versus latitude) with overlaid flight track circles at key pressure levels. The GMI-IPS consists of a handful of classes and supporting functionality that have been generalized to be compatible with any ICARTT file that adheres to the base class definition. The base class represents a generic ICARTT entry, only defining a single time entry and 3D spatial positioning parameters. Other classes inherit from this base class; several classes for input ICARTT instrument files, which contain the necessary flight positioning information as a basis for data processing, as well as other classes for output ICARTT files, which contain the interpolated model data. Utility classes provide functionality for routine procedures such as: comparing field names among ICARTT files, reading ICARTT entries from a data file and storing them in data structures, and returning a reduced spatial grid based on a collection of ICARTT entries. Although the GMI-IPS is compatible with GMI model data, it can be adapted with reasonable effort for any simulation that creates Hierarchical Data Format (HDF) files. The same can be said of its adaptability to ICARTT files outside of the context of the ATom mission. The GMI-IPS contains just under 30,000 lines of code, eight classes, and a dozen drivers and utility programs. It is maintained with GIT source code management and has been used to deliver processed GMI model data for the ATom campaigns that have taken place to date.

Damon, M. R.↗

Tomography Analysis of Orion Artemis 1 Heatshield Sample

The Orion spacecraft, under NASA's Artemis program, is an integral step in humanity's ambitions of deep space exploration, including our return to the Moon and subsequent mission to Mars. The performance of Orion's heatshield is central to ensuring the safety and success of such missions. This presentation offers a comprehensive overview of the process used in and findings derived from tomography scans of an Artemis 1 heatshield sample executed at the Lawrence Berkeley National Laboratory's Advanced Light Source. These tomography scans captured high-resolution X-Ray images of the heatshield's microstructure, allowing advanced imaging to be employed for 3D image segmentation and visualization of the sample. The Porous Media Analysis (PuMA) software stands central to our analysis, offering robust computational algorithms and methodologies to digitally compute properties of the heatshield material. The presentation discusses the following derived metrics: - Volume fractions, representing the spatial distribution and amounts of various components throughout the heatshield’s depth. - Porosity and crack distributions, offering insights into the void space within the material, critical for understanding the heatshield's structural integrity. - Fiber orientation, detailing the alignment and arrangement of fibers, significant for material orthotropy. - Permeability estimates, quantifying the passage of gas through the material, relevant for re-entry conditions and pyrolysis gasses. One distinctive feature of this study is the comparative evaluation against data obtained from tomography scans of the Exploration Flight Test-1 (EFT-1) heatshield. Such a comparison offers multiple insights, including evaluation of the consistency and repeatability of manufacturing processes as well as understanding of any evolutionary changes in heatshield design or material properties.

Micro-tomography↗