Search NASA⌕ Search

SEARCH · Search NASA

Results for “product sterilization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Sterilization System

Cox Sterile Products, Inc.'s Rapid Heat Transfer Sterilizer employs a heat exchange process that induces rapid air movement; the air becomes the heat transfer medium, maintaining a uniform temperature of 375 degrees Fahrenheit. It features pushbutton controls for three timing cycles for different instrument loads, a six-minute cycle for standard unpackaged instruments, eight minutes for certain specialized dental/medical instruments and 12 minutes for packaged instruments which can then be stored in a drawer in sterile condition. System will stay at 375 degrees all day. Continuous operation is not expensive because of the sterilizer's very low power requirements.

Source record↗

Control of microbial contamination.

Two specific applications are discussed of microbial contamination control in planetary quarantine. Under the first concept, using the clean room to control environmental microorganisms, the objective is to reduce the microbial species and keep the numbers of microorganisms within an enclosure at a low level. The clean room concept is aimed at obtaining a product that has a controlled and reduced level of microbial contamination. Under the second concept, using the microbiological barrier to control microbial contamination of a specific product, the barrier techniques are designed to prevent the entry of any microorganisms into a sterile work area. Thus the assembly of space flight hardware within the confines of a microbiological barrier is aimed at obtaining a sterile product. In theory and practice, both approaches are shown to be applicable to the planetary quarantine program.

Mcdade, J. J.↗

Oxygen Penalty for Waste Oxidation in an Advanced Life Support System: A Systems Approach

Oxidation is one of a number of technologies that are being considered for waste management and resource recovery from waste materials generated on board space missions. Oxidation processes are a very effective and efficient means of clean and complete conversion of waste materials to sterile products. However, because oxidation uses oxygen there is an "oxygen penalty" associated either with resupply of oxygen or with recycling oxygen from some other source. This paper is a systems approach to the issue of oxygen penalty in life support systems and presents findings on the oxygen penalty associated with an integrated oxidation-Sabatier-Oxygen Generation System (OGS) for waste management in an Advanced Life Support System. The findings reveal that such an integrated system can be operated to form a variety of useful products without a significant oxygen penalty.

Pisharody, Suresh↗

Effects of the thermal sterilization procedure on polymeric products

Properties of samples are tested, after thermal exposure, and values are compared with unexposed samples. Thermal stability or compatibility ratings of formulated or compounded organic polymers using trade names are made and degree of change in measured properties is assessed. Products are rated compatible, marginal, or not compatible.

Campbell, B. A.↗

Heat Melt Compaction as an Effective Treatment for Eliminating Microorganisms from Solid Waste

One of the technologies being tested at Ames Research Center as part of the logistics and repurposing project is heat melt compaction (HMC) of solid waste to reduce volume, remove water and render a biologically stable and safe product. Studies at Kennedy Space Center have focused on the efficacy of the heat melt compaction process for killing microorganisms in waste and specific compacter operation protocols, i.e., time and temperature required to achieve a sterile, stable product. The work. reported here includes a controlled study to examine the survival and potential re-growth of specific microorganisms over a 6-month period of storage after heating and compaction. Before heating and compaction, ersatz solid wastes were inoculated with Bacillus amyloliquefaciens and Rhodotorula mucilaginosa, previously isolated from recovered space shuttle mission food and packaging waste. Compacted HMC tiles were sampled for microbiological analysis at time points between 0 and 180 days of storage in a controlled environment chamber. In addition, biological indicator strips containing spores of Bacillus atrophaeus and Geobacillus stearothermophilus were imbedded in trash to assess the efficacy of the HMC process to achieve sterilization. Analysis of several tiles compacted at 180deg C for times of 40 minutes to over 2 hours detected organisms in all tile samples with the exception of one exposed to 180deg C for approximately 2 hours. Neither of the inoculated organisms was recovered, and the biological indicator strips were negative for growth in all tiles indicating at least local sterilization of tile areas. The findings suggest that minimum time/temperature combination is required for complete sterilization. Microbial analysis of tiles processed at lower temperatures from 130deg C-150deg C at varying times will be discussed, as well as analysis of the bacteria and fungi present on the compactor hardware as a result of exposure to the waste and the surrounding environment. The two organisms inoculated into the waste were among those isolated and identified from the HMC surfaces indicating the possibility of cross contamination.

Hummerick, Mary P.↗

Heat Melt Compaction as an Effective Treatment for Eliminating Microorganisms from Solid Waste

One of the technologies being tested at Ames Research Center as part of the logistics and repurposing project is heat melt compaction (HMC) of solid waste to reduce volume, remove water and render a biologically stable and safe product. Studies at Kennedy Space Center have focused on the efficacy of the heat melt compaction process for killing microorganisms in waste and specific compacter operation protocols, i.e., time and temperature, required to achieve a sterile, stable product. The work reported here includes a controlled study to examine the survival and potential re-growth of specific microorganisms over a 6-month period of storage after heating and compaction. Before heating and compaction, ersatz solid wastes were inoculated with Bacillus amyloliquefaciens and Rhodotorula mucilaginosa, previously isolated from recovered space shuttle mission food and packaging waste. Compacted HMC tiles were sampled for microbiological analysis at time points between 0 and 180 days of storage in a controlled environment chamber. In addition, biological indicator strips containing spores of Bacillus atrophaeus and Ceo bacillus stearothermophilus were imbedded in trash to assess the efficacy of the HMC process to achieve sterilization. Analysis of several tiles compacted at 180 C for times of 40 minutes to over 2 hours detected organisms in all tile samples with the exception of one exposed to 180 C for approximately 2 hours. Neither of the inoculated organisms was recovered, and the biological indicator strips were negative for growth in all tiles indicating at least local sterilization of tile areas. The findings suggest that minimum time/temperature combination is required for complete sterilization. Microbial analysis of tiles processed at lower temperatures from 130 C-150 C at varying times will be discussed, as well as analysis of the bacteria and fungi present on the compactor hardware as a result of exposure to the waste and the surrounding environment. The two organisms inoculated into the waste were among those isolated and identified from the HMC surfaces indicating the possibility of cross contamination.

Hummerick, Mary P.↗

Applications of the Strategic Defense Initiative's compact accelerators

The Strategic Defense Initiative's (SDI) investment in particle accelerator technology for its directed energy weapons program has produced breakthroughs in the size and power of new accelerators. These accelerators, in turn, have produced spinoffs in several areas: the radio frequency quadrupole linear accelerator (RFQ linac) was recently incorporated into the design of a cancer therapy unit at the Loma Linda University Medical Center, an SDI-sponsored compact induction linear accelerator may replace Cobalt-60 radiation and hazardous ethylene-oxide as a method for sterilizing medical products, and other SDIO-funded accelerators may be used to produce the radioactive isotopes oxygen-15, nitrogen-13, carbon-11, and fluorine-18 for positron emission tomography (PET). Other applications of these accelerators include bomb detection, non-destructive inspection, decomposing toxic substances in contaminated ground water, and eliminating nuclear waste.

Montanarelli, Nick↗

Portable Intravenous Fluid Production Device For Ground Use Project

Several medical conditions require the administration of intravenous (IV) fluids,but limitations of mass, volume, shelf-life, transportation, and local resources can restrict the availability of these important fluids. Such limitations are expected in long-duration space exploration missions and in remote or austere places on Earth. This design uses regular drinking water that is pumped through two filters to produce, in minutes, sterile, ultrapure water that meets the stringent quality standards of the United States Pharmacopeia for Water for Injection (Total Bacteria, Conductivity, Endo - toxins, Total Organic Carbon). The device weighs 2.2 lb (1 kg) and is 10 in. long, 5 in. wide, and 3 in. high (≈25, 13, and 7.5 cm, respectively) in its storage configuration. This handheld device produces one liter of medical-grade water in 21 minutes. Total production capacity for this innovation is expected to be in the hundreds of liters. The device contains one battery powered electric mini-pump. Alternatively, a manually powered pump can be attached and used. Drinking water enters the device from a source water bag, flows through two filters, and final sterile production water exits into a sealed, medical-grade collection bag. The collection bag contains pre-placed crystalline salts to mix with product water to form isotonic intravenous medical solutions. Alternatively, a hypertonic salt solution can be injected into a filled bag. The filled collection bag is detached from the device and is ready for use or storage. This device currently contains one collection bag, but a manifold of several pre-attached bags or replacement of single collection bags under sterile needle technique is possible for the production of multiple liters. The entire system will be flushed, sealed, and radiation-sterilized. Operation of the device is easy and requires minimal training. Drinking water is placed into the collection bag. Inline stopcock flow valves at the source and collection bags are opened, and the mini-pump is turned on by a switch to begin fluid flow. When the collection bag is completely filled with the medical- grade water, the pump can be turned off. The pump is designed so it cannot pump air, and overfilling of the collection bag with fluid is avoided by placing an equal amount of water in the source bag. Backflow is avoided by inline check valves. The filled collection bag is disconnected from its tubing and is ready for use. The source bag can be refilled for production of multiple liters, or the source bag can be replaced with an input tube that can be placed in a larger potable water source if the device is attended. The device functions in all orientations independent of any gravity fields. In addition to creating IV fluids, the device produces medical-grade water, which can be used for mixing with medications for injection, reconstituting freeze-dried blood products for injection, or for wound hydration or irrigation. Potential worldwide use is expected with medical activities in environments that have limited resources, storage, or resupply such as in military field operations, humanitarian relief efforts, submarines, commercial cruise ships, etc.

Technology Portfolio System↗

Bionutrients-1, On-Demand Production of Nutrients in Space

Future long-duration missions face significant challenges maintaining crew health. A critical area is supplying adequate nutrition, as certain vitamins and nutrients in supplied foods and supplements demonstrate substantial degradation during extended storage. To address this issue, we are developing and flight-testing a platform technology that demonstrates in situ microbial production of targeted nutrients over extended mission durations. This 5-year experiment, known as BioNutrients-1, was started on the International Space Station in May 2019. It involves two components: an on-orbit hydration and production experiment; and the development of space-compatible, key bio-manufacturing microorganisms. On-orbit testing utilizes a small “production pack” system that encloses sterile edible growth substrate and desiccated Saccharomyces cerevisiae strains genetically engineered to produce the nutrients beta-carotene or zeaxanthin. On hydration and mixing of the production pack, the organisms revive and grow until limited by the depletion of growth media, hypothetically leading to consistent amounts of biomass and nutrients. In eventual mission applications, the packet contents would be heat treated to inactivate the microorganisms prior to consumption. For these flight experiments, the packet will not be heat treated, but will instead be frozen for return to Earth for analyses. In addition to the production pack trials, 14 different microorganisms/treatments were also delivered to ISS for long-duration storage. These samples will be intermittently returned to Earth and analyzed to determine survival rates and genomics. For this presentation, initial data from returned samples and ground controls will be discussed.

Hindupur, Aditya↗

BioNutrients-1: On-Demand Production of Nutrients in Space

Future long-duration missions face significant challenges maintaining crew health. A critical area is supplying adequate nutrition, as certain vitamins and nutrients in supplied foods and supplements demonstrate substantial degradation during extended storage. To address this issue, we are developing and flight-testing a platform technology that demonstrates in situ microbial production of targeted nutrients over extended mission durations. This 5-year experiment, known as BioNutrients-1, was started on the International Space Station in May 2019. It involves two components: an on-orbit hydration and production experiment; and the development of space-compatible, key bio-manufacturing microorganisms. On-orbit testing utilizes a small "production pack" system that encloses sterile edible growth substrate and desiccated Saccharomyces cerevisiae strains genetically engineered to produce the nutrients beta-carotene or zeaxanthin. On hydration and mixing of the production pack, the organisms revive and grow until limited by the depletion of growth media, hypothetically leading to consistent amounts of biomass and nutrients. In eventual mission applications, the packet contents would be heat treated to inactivate the microorganisms prior to consumption. For these flight experiments, the packet will not be heat treated, but will instead be frozen for return to Earth for analyses. In addition to the production pack trials, 14 different microorganisms/treatments were also delivered to ISS for long-duration storage. These samples will be intermittently returned to Earth and analyzed to determine survival rates and genomics. For this presentation, initial data from returned samples and ground controls will be discussed.

Hindupur, Aditya↗

Screwworm Eradication Data System (SEDS) applications program documentation, part 2

National Oceanic and Atmospheric Administration (NOAA) satellite data, which is in analog tape form, is converted into output data products. These products are used by investigators in determining optimum areas for airdrops of steril screwworm flies over Mexico. The output product of SEDS takes the form of imagery data film slides showing Mexico and the lower southwest portion of the United States. The area analog preprocessing phase of the SEDS task is covered.

Source record↗

Microorganisms in the Stratosphere (MIST): In-flight Sterilization with UVC Leds

The stratosphere (10 km to 50 km above sea level) is a unique place on Earth for astrobiological studies of microbes in extreme environments due to the combination of harsh conditions (high ultraviolet radiation, low pressure, desiccation, and low temperatures). Microorganisms in the Stratosphere (MIST) will attempt to characterize the diversity of microbes at these altitudes using a balloon collection device on a meteorological weather balloon. A major challenge of such an aerobiology study is the potential for ground contamination that makes it difficult to distinguish between collected microbes and contaminants. One solution is to use germicidal ultraviolet light emitting diodes (UV LEDs) to sterilize the collection strip. To use this solution, an optimal spatial arrangement of the lights had to be determined to ensure the greatest chance of complete sterilization within the 30 to 60 minute time of balloon ascent. A novel, 3D-printed test stand was developed to experimentally determine viable Bacillus pumilus SAFR-032 spore reduction after exposure to ultraviolet radiation at various times, angles, and distances. Taken together, the experimental simulations suggested that the UV LEDs on the MIST flight hardware should be active for at least 15 minutes and mounted within 4 cm of the illuminated surface at any angle to achieve optimal sterilization. These findings will aid in the production of the balloon collection device to ensure pristine stratospheric microbial samples are collected. Flight hardware capable of in-flight self-sterilization will enable future life detection missions to minimize both forward contamination and false positives.

Exobiology↗