Search NASA⌕ Search

SEARCH · Search NASA

Results for “profile”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Comparison of scattering ratio profiles retrieved from ALADIN/Aeolus and CALIOP/CALIPSO observations and preliminary estimates of cloud fraction profiles

The space-borne active sounders have been contributing invaluable vertically resolved information of atmospheric optical properties since the launch of Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observation (CALIPSO) in 2006. To build long-term records from space-borne lidars useful for climate studies, one has to understand the differences between successive space lidars operating at different wavelengths, flying on different orbits, and using different viewing geometries, receiving paths, and detectors. In this article, we compare the results of Atmospheric Laser Doppler INstrument (ALADIN) and Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP) lidars for the period from 28 June to 31 December 2019. First, we build a dataset of ALADIN–CALIOP collocated profiles (Δdist<1°; Δtime<6 h). Then we convert ALADIN's 355 nm particulate backscatter and extinction profiles into the scattering ratio vertical profiles SR(z) at 532 nm using molecular density profiles from Goddard Earth Observing System Data Assimilation System, version 5 (GEOS-5 DAS). And finally, we build the CALIOP and ALADIN globally gridded cloud fraction profiles CF(z) by applying the same cloud detection threshold to the SR(z) profiles of both lidars at the same spatial resolution. Before comparing the SR(z) and CF(z) profiles retrieved from the two analyzed lidar missions, we performed a numerical experiment to estimate the best achievable cloud detection agreement CDA norm (z) considering the differences between the instruments. We define CDA norm (z) in each latitude–altitude bin as the occurrence frequency of cloud layers detected by both lidars, divided by a cloud fraction value for the same latitude–altitude bin. We simulated the SR(z) and CF(z) profiles that would be observed by these two lidars if they were flying over the same atmosphere predicted by a global model. By analyzing these simulations, we show that the theoretical limit for CDA$_{norm}^{theor}$(z) for a combination of ALADIN and CALIOP instruments is equal to 0.81±0.07 at all altitudes. In other words, 19 % of the clouds cannot be detected simultaneously by two instruments due to said differences. The analyses of the actual observed CALIOP–ALADIN collocated dataset containing ~78 000 pairs of nighttime SR(z) profiles revealed the following points: (a) the values of SR(z) agree well up to ~3 km height. (b) The CF(z) profiles show agreement below ~3 km, where ~80 % of the clouds detected by CALIOP are detected by ALADIN as expected from the numerical experiment. (c) Above this height, the CDA$_{norm}^{obs}$(z) reduces to ~50 %. (d) On average, better sensitivity to lower clouds skews ALADIN's cloud peak height in pairs of ALADIN–CALIOP profiles by ~0.5±0.6 km downwards, but this effect does not alter the heights of polar stratospheric clouds and high tropical clouds thanks to their strong backscatter signals. (e) The temporal evolution of the observed CDA$_{norm}^{obs}$(z) does not reveal any statistically significant change during the considered period. This indicates that the instrument-related issues in ALADIN L0/L1 have been mitigated, at least down to the uncertainties of the following CDA$_{norm}^{obs}$(z) values: 68±12 %, 55±14 %, 34±14 %, 39±13 %, and 42±14 % estimated at 0.75, 2.25, 6.75, 8.75, and 10.25 km, respectively.

54 ENVIRONMENTAL SCIENCES↗

EVs@Scale Next-Gen Profiles - EV Profile Capture 2023

As part of the U.S. DOE EVs@Scale consortium Next-Gen Profiles (NGP) project, the profile capture of production electric vehicles undergoing high power charging (HPC) is conducted over a wide range of conditions to explore variance and performance. Charge session parameters are collected from both the electric vehicle (EV) and electric vehicle supply equipment (EVSE) at a rate of 10Hz and entered into a time-series database for analysis. These charge profiles are captured under nominal and off-nominal conditions, exploring the impact of battery state of charge (SOC), battery temperature, vehicle condition, smart charge management (SCM), and EVSE limitations. Nominal conditions are defined to be ideal conditions that should transfer the maximum allowable energy in the minimum possible amount of time. Nominal condition profiles are compared across EVs to characterize state-of-the-art EV charging performance against one another. Off-nominal condition profiles are compared against its nominal condition profile counterpart to highlight the variance across less desirable starting conditions within a single EV. Under nominal conditions, most EVs can achieve the original equipment manufacturer (OEM) rated peak-power and charge times. Peak power across EVs has variance due to the vehicle design, battery topology, charging strategy, etc. These 10-100% nominal preconditioned charge profiles across 13 EVs (11 light-duty (LD), 2 heavy-duty (HD)) were used for analysis in power curve analysis, power distribution, SOC and range comparison, thermal impacts of current draw, battery pack size and energy charged, and ramp rates. Power curve analysis show the uniqueness in power vs time curves across all EVs, breaking down the features of a typical profile and where variation is typically seen. Power distribution results showed that over 50% of charge time is spent below 50kW and only 12.1% is spent above 200kW. SOC and range performance yielded different top performing EVs when exploring goals of performance from SOC and range gained after 10-min (EV2) and 20-min (EV8), and time-to-achieve 80% SOC (EV8) and 200 miles of range (EV1). Current draw from 400-volt EVs had a higher thermal impact to cable/connector temperatures when compared to 800-volt EVs, due to a higher current requirement to achieve similar power levels. There was high variance in C rating, a useful metric when comparing the relationship between peak/average charge session power and relative battery pack size, across EVs under test. Ramp rates during initial power transfer were examined, fastest and slowest speeds ranging from 192.5kW/second to 2.6kW/second respectively. A similar analysis of ramp rates was also conducted for OCPP curtailment testing, where EVs underwent a 2-minute 65A curtailment request before returning to full-power charge. Under off-nominal conditions, most EVs experienced variation from the nominal condition profiles. EVs that underwent the full set of NGP defined testing conditions were compared, analysis of which was categorized by 800-volt and 400-volt EVs. It should be noted that the 800-volt EVs had significantly higher peak power ratings than the 400-volt EVs, and thus were more prone to variance. Initial state of charge, battery temperature, and vehicle condition had a considerable impact on peak power levels and charge time for the 800-volt vehicles under test. EVSE limited tests lowered achievable power down to 200kW, greatly impacted 800-volt charging power, and had little to no effect on 400-volt charging power. Adapter testing was performed on a single 400-volt EV, where power and current limitations were found but overall charge time was not significantly impacted. Adapter and boost converter testing was performed on a single 800-volt EV, where both charge power and charge time were greatly impacted. Charge profiles are unique, and comparing such requires analysis that examines starting conditions, vehicle and battery topologies,

Charging↗

EVs@Scale Next-Gen Profiles - EV Profile Capture 2024

As part of the U.S. DOE EVs@Scale consortium Next-Gen Profiles (NGP) project, the profile capture and analysis of production electric vehicles undergoing high power charging (HPC) is conducted over a wide range of conditions to explore variance and performance. Charge session parameters are collected from both the electric vehicle (EV) and electric vehicle supply equipment (EVSE) at a rate of 10Hz and entered into a time-series database for analysis. These charge profiles are captured under nominal and off-nominal conditions, exploring the impact of battery state of charge (SOC), battery temperature, vehicle condition, smart charge management (SCM), and EVSE limitations. Nominal conditions are defined to be ideal conditions that should transfer the maximum allowable energy in the minimum possible amount of time. Nominal condition profiles are compared across EVs to characterize state-of-the-art EV charging performance against one another. Off-nominal condition profiles are compared against its nominal condition profile counterpart to highlight the variance across less desirable starting conditions within a single EV. This EV Profile Capture 2024 report stands as an update from the EV Profile Capture 2023 report to include the additional EV & EVSE assets tested and analyzed in 2024. The major updates within this report include the addition of three next-generation electric vehicles, added test cases, and further analysis. This expansion of analysis includes power profiles, power distribution, quantifying SOC, energy and range performance, EVSE limitation impacts, boost converter performance, etc. Additionally, NGP time-series data has been used as input towards three national laboratory-led grid modelling efforts: ANL’s IEEE-37 HIL model, INL’s Caldera model, and NREL’s EVI-X model. A summary of these platforms and how NGP has worked to improve their effectiveness has also been added to this years’ report.

Thurston, Sam↗

EV Profile Capture 2025: Next-Gen Profiles Project Report

As part of the Next-Gen Profiles (NGP) project, the profile capture and analysis of production electric vehicles undergoing high-power charging (HPC) is conducted over a wide range of conditions to explore variance and performance. Charge session parameters are collected from both the electric vehicle (EV) and electric vehicle supply equipment (EVSE) at a rate of 10Hz and entered into a time-series database for analysis. These charge profiles are captured under nominal and off-nominal conditions, exploring the impact of starting battery state of charge (SOC), battery temperature, vehicle condition, smart charge management (SCM), EVSE limitations and charging adapter usage. Nominal conditions are defined as ideal conditions that should transfer the maximum allowable energy in the minimum possible amount of time. Nominal condition profiles are compared across EVs to characterize state-of-the-art EV charging performance against one another. Off-nominal condition profiles are compared against their nominal condition profile counterparts to highlight the variance across less desirable starting conditions within a single EV.

33 ADVANCED PROPULSION SYSTEMS↗

Tilted lidar profiling: Development and testing of a novel scanning strategy for inhomogeneous flows

The most common profiling techniques for the atmospheric boundary layer based on a monostatic Doppler wind lidar rely on the assumption of horizontal homogeneity of the flow. This assumption breaks down in the presence of either natural or human-made obstructions that can generate significant flow distortions. The need to deploy ground-based lidars near operating wind turbines for the American WAKE experimeNt (AWAKEN) spurred a search for novel profiling techniques that could avoid the influence of the flow modifications caused by the wind farms. With this goal in mind, two well-established profiling scanning strategies have been retrofitted to scan in a tilted fashion and steer the beams away from the more severely inhomogeneous region of the flow. Results from a field test at the National Renewable Energy Laboratory's 135-m meteorological tower show that the accuracy of the horizontal mean flow reconstruction is insensitive to the tilt of the scan, although higher-order wind statistics are severely deteriorated at extreme tilts mainly due to geometrical error amplification. A numerical study of the AWAKEN domain based on the Weather Research and Forecasting Model and large-eddy simulation are also conducted to test the effectiveness of tilted profiling. It is shown that a threefold reduction of the error on inflow mean wind speed can be achieved for a lidar placed at the base of the turbine using tilted profiling.

17 WIND ENERGY↗

Fast Quasi-Static Time-Series Simulation for Accurate PV Inverter Semiconductor Fatigue Analysis with a Long-Term Solar Profile

Power system simulations with long-term data typically have large time steps varying from one second to a few minutes. However, for PV inverter semiconductors, the minimum thermal stress cycle occurs over the fundamental grid frequency (50 or 60 Hz). This requires the time step of the fatigue simulation to be around 100 µs. This small time step requires long computation times to process yearly power production profiles. This paper proposes a fast fatigue simulation for inverter semiconductors using the quasi-static time series (QSTS) simulation concept. The proposed simulation calculates the steady state of the semiconductor junction temperature by using a Fast Fourier Transform (FFT). The small thermal cycling during a switching period and even over the fundamental waveform is disregarded to further accelerate the simulation speed. The resulting time step of the fatigue simulation is 15 minutes, which is consistent with the solar dataset. The error of the proposed simulation is 0.16% compared to the fatigue simulation results using the complete thermal stress profile. A PV inverter that responds to a Transactive Energy System (TES) is simulated to demonstrate the use of the proposed fatigue simulation. The proposed simulation has the potential to co-simulate with system level simulation tools that also adopt the QSTS concept.

Liu, Yunting↗

Velocity Profiling of a Gas–Solid Fluidized Bed Using Electrical Capacitance Volume Tomography

In this study, a method of producing velocity profile maps from electrical capacitance volume tomography (ECVT) measurements by reconstructing displacement from measured changes in capacitance is developed and applied to fluidized bed systems. The mapping of the reconstruction leverages the gradient of the sensitivity distribution of the ECVT sensor to circumvent the need for image cross correlation techniques. Experimental data of both bubbling and slugging fluidized beds are collected in a cold flow model. Adaptation of the technique is discussed in detail, and velocity profiles are obtained for a range of gas flow rates. The produced velocity maps are compared against the established methods of cross correlation and against empirical correlations from the literature and are found to agree well in tracking slug and bubble velocity. The exception is when the tracked object is large relative to the ECVT sensor dimensions, a scenario that can be avoided through proper sensor design. The quantities of average velocity, momentum, and solid and gas volume fraction are derived from the image and velocity profiles. The results demonstrate and extend the power of ECVT as a measurement tool for the study and monitoring of gas–solid fluidized beds by providing a computationally cheaper alternative to 3-D cross correlation for deriving velocity profiles.

47 OTHER INSTRUMENTATION↗

SITCOMTN-161: PSF assessment in the field of Abell 360 and shapeHSM shear profile using LSSTComCam data

The Rubin LSSTComCam on-sky campaign performed at the end of 2024 provided observations of the Abell 360 galaxy cluster; these data allow a preliminary study of cluster weak lensing analysis using Rubin Data Preview 1 (DP1) data. Among all the steps required for such analyses, accurate modeling of the PSF is essential. This work uses several diagnostics, mostly based on the residuals between the second moments of stars and the PSF model, to characterize the accuracy of the PSF modeling in the A360 field. We find the level of the residuals to be sufficiently low not to hinder the measurement of the tangential shear profile around A360. With a simple source selection process, we demonstrate that outputs of the LSST Science Pipelines can be used to detect the tangential shear profile in Abell 360 at the 3.6σ level, and our analysis indicates that contamination from PSF modeling systematics is negligible.

Dell'Antonio, Ian [Brown University]↗

SITCOMTN-165: Surface brightness profiles around massive galaxies in LSSTComCam data

Low surface brightness photometry of massive galaxies can probe the extended stellar halos and intracluster light but is often limited by background subtraction and masking systematics. Here we present radial surface brightness profiles for the brightest cluster galaxy of Abell 360 and 2dFGRS TGS323Z113 using Rubin Observatory Commissioning Camera (LSSTComCam) Data Preview 1 in the g, r, and z bands. Our results show that the LSSTComCam data can go down to ~28 mag arcsec^-2 in the r band. Comparison to DECaLS measurements processed with Legacyhalos shows good agreement of surface brightness profiles at small radii while the LSSTComCam data extend deeper at larger radii.

79 ASTRONOMY AND ASTROPHYSICS↗

Observing Profiles of Derived Kinematic Field Quantities Using a Network of Profiling Sites

Abstract Observations of thermodynamic and kinematic parameters associated with derivatives of the thermodynamics and wind fields, namely, advection, vorticity, divergence, and deformation, can be obtained by applying Green’s theorem to a network of observing sites. The five nodes that comprise the Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) profiling network, spaced 50–80 km apart, are used to obtain measurements of these parameters over a finite region. To demonstrate the applicability of this technique at this location, it is first applied to gridded model output from the High-Resolution Rapid Refresh (HRRR) numerical weather prediction model, using profiles from the locations of ARM network sites, so that values calculated from this method can be directly compared to finite difference calculations. Good agreement is found between both approaches as well as between the model and values calculated from the observations. Uncertainties for the observations are obtained via a Monte Carlo process in which the profiles are randomly perturbed in accordance with their known error characteristics. The existing size of the ARM network is well suited to capturing these parameters, with strong correlations to model values and smaller uncertainties than a more closely spaced network, yet it is small enough that it avoids the tendency for advection to go to zero over a large area.

54 ENVIRONMENTAL SCIENCES↗

Temperature profiling at the American WAKE ExperimeNt (AWAKEN): methodology and uncertainty quantification

We quantify the accuracy of the temperature profiling from ground-based spectral infrared radiance observations at the American WAKE ExperimeNt (AWAKEN). Results from pre-campaign tests and comparisons with in-situ ground-based and airborne sensors at AWAKEN indicate that temperature profiles agree satisfactorily with traditional instruments for wind energy applications. The bias is within a fraction of a degree and appears to be related to atmospheric stability. Root-mean-square differences from the reference instruments are always smaller than a degree and are often well described by the online uncertainty estimation product. Height-to-height and site-to-site temperature differences are in excellent agreement with in-situ observations, which justifies the use of temperature profilers to characterize static stability and spatial gradients of temperature.

17 WIND ENERGY↗

Comparative Analysis of Corrinoid Profiles across Host-Associated and Environmental Samples

Vitamin B 12 (the cyanated form of cobalamin cofactors) is best known for its essential role in human health. In addition to its function in human metabolism, cobalamin also plays important roles in microbial metabolism and can impact microbial community function. Cobalamin is a member of the structurally diverse family of cofactors known as cobamides that are produced exclusively by certain prokaryotes. Cobamides are considered shared nutrients in microbial communities because the majority of bacteria that possess cobamide-dependent enzymes cannot synthesize cobamides de novo. Furthermore, different microbes have evolved metabolic specificity for particular cobamides, and therefore, the availability of cobamides in the environment is important for cobamide-dependent microbes. Determining the cobamides present in an environment of interest is essential for understanding microbial metabolic interactions. By examining the abundances of different cobamides in diverse environments, including 10 obtained in this study, we find that, contrary to its preeminence in human metabolism, cobalamin is relatively rare in many microbial habitats. Comparison of cobamide profiles of mammalian gastrointestinal samples and wood-feeding insects reveals that host-associated cobamide abundances vary and that fecal cobamide profiles differ from those of their host gastrointestinal tracts. Environmental cobamide profiles obtained from aquatic, soil, and contaminated groundwater samples reveal that the cobamide compositions of environmental samples are highly variable. As the only commercially available cobamide, cobalamin is routinely supplied during microbial culturing efforts. Furthermore, these findings suggest that cobamides specific to a given microbiome may yield greater insight into nutrient utilization and physiological processes that occur in these habitats.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A method for modeling battery-temperature-aware EV power profiles utilizing Next-Gen Profile data

With the expected increase in the number of electric vehicles (EVs) on the road in the coming years, it is important that analysis tools are capable of modeling and predicting the expected load on the power grid due to both individual EV charging sessions as well as large populations of vehicles. To do this accurately, the power profile of an EV charge session must be accurately modeled, including for scenarios where the temperature is above or below the ideal, and also take into account the nuances of manufacturer charging preferences. This paper introduces a method that utilizes the data in the Next-Gen Profile (NGP) data collection project to build a model of EV charging that takes into account the variations in charging power that occur due to off-nominal battery temperature and manufacturer preferences that limit power due to cold temperatures or high battery state-of-charge.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Spatial profiles of photon chemical potential in near-field thermophotovoltaic cells

Emitted photons stemming from the radiative recombination of electron–hole pairs carry chemical potential in radiative energy converters. This luminescent effect can substantially alter the local net photogeneration in near-field thermophotovoltaic cells. Several assumptions involving the luminescent effect are commonly made in modeling photovoltaic devices; in particular, the photon chemical potential is assumed to be zero or a constant prescribed by the bias voltage. The significance of photon chemical potential depends upon the emitter temperature, the semiconductor properties, and the injection level. Hence, these assumptions are questionable in near-field thermophotovoltaic devices with nanoscale separation distances between the emitter and the cell. In the present work, an iterative solver that combines fluctuational electrodynamics with the drift-diffusion model is developed to tackle the coupled photon and charge transport problem, enabling the determination of the spatial profile of photon chemical potential beyond the detailed balance approach. Here, the difference between the results obtained by allowing the photon chemical potential to vary spatially and by assuming a constant value demonstrates the limitations of the conventional approaches. This study is critically important for performance evaluation of near-field thermophotovoltaic systems with nanoscale vacuum gaps.

30 DIRECT ENERGY CONVERSION↗

Simultaneous reproduction of experimental profiles, fluxes, transport coefficients, and turbulence characteristics via nonlinear gyrokinetic profile predictions in a DIII-D ITER similar shape plasma

Experimental conditions obtained on the DIII-D tokamak in the ITER Similar Shape (ISS) have been compared extensively with nonlinear gyrokinetic simulation using the CGYRO code [Candy et al., J. Comput. Phys. 324, 73–93 (2016)] with comparisons spanning ion and electron heat fluxes, electron and impurity particle transport, and turbulent fluctuation levels and characteristics. Bayesian optimization techniques [Rodriguez-Fernandez et al., Nucl. Fusion 62(7), 076036 (2022)], combined with nonlinear gyrokinetics, have been used to obtain simultaneously Qi, Qe, and Γe flux-matched profiles that are found to be in good agreement with experimental profile measurements. Synthetic diagnostics were used to compare measured beam emission spectroscopy and correlation electron cyclotron emission turbulent fluctuations with nonlinear simulation. Although some disagreements exist, nonlinear simulations are found to be in generally good agreement with measured fluctuation levels, spectral shapes, and measured radial trends in low-k δne/ne and δTe/Te. Low (Li and C) and mid-Z (Ca) impurity transport was also compared with these flux-matched simulations. Fully stripped, low-Z impurities are well reproduced by the gyrokinetic modeling while clear disagreement exists in comparisons with mid-Z impurities. Nonlinear gyrokinetic investigation into the Z dependence of impurity transport in the ISS conditions is also performed, demonstrating clear trends of impurity diffusion with impurity Z (both D∝Z and D∝1/Z) that vary with the radial location studied. These trends are shown to result from the local dominance of ion temperature gradient or ∇n driven trapped electron mode turbulence and may contribute to the disagreement between simulation and experiment in mid-Z impurity transport. The results of this work represent one of the most complete validation studies of the gyrokinetic model performed to date and provide an example of new capabilities for predicting performance in future fusion devices.

Physics↗

Density profiles in stellarators: an overview of particle transport, fuelling and profile shaping studies at TJ-II

We provide an overview of activities carried out at the TJ-II stellarator for improving our understanding of- and developing plasma physics models for particle density profiles in stellarators. Namely, we report on recent progress in turbulent particle transport simulation, validation of pellet deposition models, density profile shaping for performance control and new experimental techniques for edge turbulence and plasma-neutral interaction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Repeated exposure to eucalyptus wood smoke alters pulmonary gene and metabolic profiles in male Long-Evans rats

Abstract Exposure to wildfire smoke is associated with both acute and chronic cardiopulmonary illnesses, which are of special concern for wildland firefighters who experience repeated exposure to wood smoke. It is necessary to better understand the underlying pathophysiology by which wood smoke exposure increases pulmonary disease burdens in this population. We hypothesize that wood smoke exposure produces pulmonary dysfunction, lung inflammation, and gene expression profiles associated with future pulmonary complications. Male Long-Evans rats were intermittently exposed to smoldering eucalyptus wood smoke at 2 concentrations, low (11.0 ± 1.89 mg/m3) and high (23.7 ± 0.077 mg/m3), over a 2-week period. Whole-body plethysmography was measured intermittently throughout. Lung tissue and lavage fluid were collected 24 h after the final exposure for transcriptomics and metabolomics. Increasing smoke exposure upregulated neutrophils and select cytokines in the bronchoalveolar lavage fluid. In total, 3446 genes were differentially expressed in the lungs of rats in the high smoke exposure and only 1 gene in the low smoke exposure (Cd151). Genes altered in the high smoke group reflected changes to the Eukaryotic Initiation Factor 2 stress and oxidative stress responses, which mirrored metabolomics analyses. xMWAS-integrated analysis revealed that smoke exposure significantly altered pathways associated with oxidative stress, lung morphogenesis, and tumor proliferation pathways. These results indicate that intermittent, 2-week exposure to eucalyptus wood smoke leads to transcriptomic and metabolic changes in the lung that may predict future lung disease development. Collectively, these findings provide insight into cellular signaling pathways that may contribute to the chronic pulmonary conditions observed in wildland firefighters.

Toxicology↗