Search NASA⌕ Search

SEARCH · Search NASA

Results for “progressive precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A General Framework for Progressive Data Compression and Retrieval

In scientific simulations, observations, and experiments, the transfer of data to and from disk and across networks has become a major bottleneck for data analysis and visualization. Compression techniques have been employed to tackle this challenge, but traditional lossy methods often demand conservative error tolerances to meet the numerical accuracy requirements of both anticipated and unknown data analysis tasks. Progressive data compression and retrieval has emerged as a promising solution, where each analysis task dictates its own accuracy needs. However, few analysis algorithms inherently support progressive data processing, and adapting compression techniques, file formats, client/server frameworks, and APIs to support progressivity can be challenging. Here, this paper presents a framework that enables progressive-precision data queries for any data compressor or numerical representation. Our strategy hinges on a multi-component representation that successively reduces the error between the original and compressed field, allowing each field in the progressive sequence to be expressed as a partial sum of components. We have implemented this approach with four established scientific data compressors and assessed its effectiveness using real-world data sets from the SDRBench collection. The results show that our framework competes in accuracy with the standalone compressors it is based upon. Additionally, (de)compression time is proportional to the number of components requested by the user. Finally, our framework allows for fully lossless compression using lossy compressors when a sufficient number of components are employed.

97 MATHEMATICS AND COMPUTING↗

Three Decades of Precision Orbit Determination Progress, Achievements, Future Challenges and its Vital Contribution to Oceanography and Climate Research

Although satellite altimetry has been around for thirty years, the last fifteen beginning with the launch of TOPEX/Poseidon (TP) have yielded an abundance of significant results including: monitoring of ENS0 events, detection of internal tides, determination of accurate global tides, unambiguous delineation of Rossby waves and their propagation characteristics, accurate determination of geostrophic currents, and a multi-decadal time series of mean sea level trend and dynamic ocean topography variability. While the high level of accuracy being achieved is a result of both instrument maturity and the quality of models and correction algorithms applied to the data, improving the quality of the Climate Data Records produced from altimetry is highly dependent on concurrent progress being made in fields such as orbit determination. The precision orbits form the reference frame from which the radar altimeter observations are made. Therefore, the accuracy of the altimetric mapping is limited to a great extent by the accuracy to which a satellite orbit can be computed. The TP mission represents the first time that the radial component of an altimeter orbit was routinely computed with an accuracy of 2-cm. Recently it has been demonstrated that it is possible to compute the radial component of Jason orbits with an accuracy of better than 1-cm. Additionally, still further improvements in TP orbits are being achieved with new techniques and algorithms largely developed from combined Jason and TP data analysis. While these recent POD achievements are impressive, the new accuracies are now revealing subtle systematic orbit error that manifest as both intra and inter annual ocean topography errors. Additionally the construction of inter-decadal time series of climate data records requires the removal of systematic differences across multiple missions. Current and future efforts must focus on the understanding and reduction of these errors in order to generate a complete and consistent time series of improved orbits across multiple missions and decades required for the most stringent climate-related research. This presentation discusses the POD progress and achievements made over nearly three decades, and presents the future challenges, goals and their impact on altimetric derived ocean sciences.

Luthcke, Scott↗

History of Photometric Precision

A history of photometric precision is given. The fixing of the scale of stellar magnitudes, progress toward precision and accuracy, and the use of photography are discussed.

Young, A. T.↗

Mapping by VESGEN of Blood Vessels in the Retinas of ISS Crew Members and Bed Rest Subjects for Increased Understanding of VIIP

Research by NASA has established that significant risks for visual impairment in association with increased intracranial pressure (VIIP) are incurred by microgravity spaceflight, especially long-duration missions. Impairments include decreased near visual acuity, posterior globe flattening, choroidal folds, optic disc edema, and cotton wool spots. Much remains to be learned about the etiology of VIIP before effective countermeasures can be developed. Contributions of retinal vascular remodeling to the etiology of VIIP have not yet been investigated, primarily due to the current lack of ophthalmic tools for precisely measuring progressive pathophysiological remodeling of the retinal microvasculature. Although ophthalmic science and clinical practice are now highly sophisticated at detecting indirect, secondary signs of vascular remodeling such as cotton wool spots that arise during the progression of retinal vascular diseases, methods for quantifying direct, primary vascular changes are not yet established. To help develop insightful analysis of retinal vascular remodeling for aerospace medicine, we will map and quantify by our innovative VESsel GENeration Analysis (VESGEN) software the remodeling status of retinal blood vessels in crew members before and after ISS missions, and in healthy human subjects before and after head-down tilt bed rest. For this proof-of-concept study, we hypothesize that pathophysiological remodeling of retinal blood vessels occurs in coordination with microgravity-induced fluid shifts prior to development of visual impairments. VESGEN analysis in previous research supported by the US National Institutes of Health identified surprising new opportunities to regenerate retinal vessels during early-stage progression of the visually impairing, potentially blinding disease, diabetic retinopathy.

ISS Crew↗

NASA SPLICE Project: Development and Testing of Precision Landing GN&C Technologies

This presentation shows NASA's progress in developing precision landing and hazard avoidance technologies during the last few years through its ALHAT, COBALT and now SPLICE projects. The talk shows how these projects intend to use active optical sensors to map landing surfaces and identify hazards for future lander missions. The talk will be given at an Entry Descent and Landing session at a NASA Technical Interchange Meeting on active optical sensor systems.

Restrepo, Carolina↗

When Do Band Gap Calculations Agree with Experiments in Monolayer-Protected Cu 14 and Au 20 Atomically Precise Nanoclusters? A (TD)-DFT Comparison of HOMO–LUMO, Fundamental, Optical, and Electrochemical Energy Gaps

In view of the tremendous progress in atomically precise metal nanoclusters where electrochemical and optical energetics are routinely supported by computations to establish structure−function correlations, we explore the relationship between different protocols for measuring and computing band gaps of two distinct organic ligand-protected nanoclusters: [Cu 14 H 10 (MBN) 3 (PPh 3 ) 8 ] + and Au 20 (TBBT) 16 . Through UV/visible spectroscopy and differential pulse voltammetry, we measure optical and electrochemical band gaps in those systems. We then compare these experimentally determined gaps to HOMO−LUMO gaps, fundamental gaps, vertical excitation energies, and E o ox − E o red potentials computed using different density functional theory (DFT) or time-dependent DFT (TDDFT) methods. Specifically, in both copper and gold nanoclusters, we test the effect of truncating inert ligands from the model and compare density functionals with varying degrees of Hartree−Fock (HF) exchange from 0 to 50%, range-separated hybrids with a varying long-range tuning parameter, different correlation functionals, basis sets, and (equilibrium and nonequilibrium) continuum solvation models. Despite having different frontier orbital characters (the copper nanocluster has a metal-to-ligand charge transfer character while the gold nanocluster has metal-centered frontier orbitals), both nanoclusters display a similar sensitivity of the HOMO−LUMO gap to the HF exchange that is partially mitigated when computing the fundamental, optical, and electrochemical gaps. Other factors, such as the nature of the correlation functional, basis set, and geometry relaxation, have a considerably smaller effect on computed band gaps in these systems. Overall, this work provides guidelines for factors of varied importance for correlating computed and experimental band gap values.

Chemical calculations↗

Progress on Passive Sensor for Ultra-Precise Measurement of Carbon Dioxide from Space

Global measurements of atmospheric carbon dioxides (CO2) are needed to resolve significant discrepancies that exist in our understanding of the global carbon budget and, therefore, man's role in global climate change. The science measurement requirements for CO2 are extremely demanding (precision c .3%) No atmospheric chemical species has ever been measured from space with this precision. We are developing a novel application of a Fabry-Perot interferometer to detect spectral absorption of reflected sunlight by CO2 and O2 in the atmosphere. Preliminary design studies indicate that the method will be able to achieve the sensitivity and signal-to-noise required to measure column CO2 at the target specification. We are presently engaged in the construction of a prototype instrument for deployment on an aircraft to test the instrument performance and our ability to retrieve the data in the real atmosphere. In the first 6 months we have assembled a laboratory bench system to begin testing the optical and electronic components. We are also undertaking some measurements of signal and noise levels for actual sunlight reflecting from the ground. We shall present results from some of these ground based studies and discuss their implications for a space based system.

Heaps, William S.↗

Progress on Passive Sensor for Ultra-Precise Measurement of C02

We will present results from a novel instrument employing a Fabry-Perot interferometer to measure column carbon dioxide with great precision. These measurements are very important for improving our understanding of the global warming phenomenon. The instrument technique can be extended to a number of other important trace gases in the atmosphere.

Heaps, William S.↗

Surgical force detection probe

The development progress of a precision electro-mechanical instrument which allows the detection and documentation of the forces and moment applied to human tissue during surgery (under actual operation room conditions), is reported. The pen-shaped prototype probe which measures 1/2 inch in diameter and 7 inches in length was fabricated using an aerodynamic balance. The aerodynamic balance, a standard wind tunnel force and moment sensing transducer, measures the forces and the moments transmitted through the surgeon's hand to the human tissue during surgery. The prototype probe which was fabricated as a development tool was tested successfully. The final version of the surgical force detection probe will be designed based on additional laboratory tests in order to establish the full scale loads. It is expected that the final product will require a simplified aerodynamic balance with two or three force components and one moment component with lighter full scale loads. A signal conditioner was fabricated to process and display the outputs from the prototype probe. This unit will be interfaced with a PC-based data system to provide automatic data acquisition, data processing, and graphics display. The expected overall accuracy of the probe is better than one percent full scale.

Tcheng, Ping↗

GPS common-view time transfer

The introduction of the GPS common-view method at the beginning of the 1980's led to an immediate and dramatic improvement of international time comparisons. Since then, further progress brought the precision and accuracy of GPS common-view intercontinental time transfer from tens of nanoseconds to a few nanoseconds, even with SA activated. This achievement was made possible by the use of the following: ultra-precise ground antenna coordinates, post-processed precise ephemerides, double-frequency measurements of ionosphere, and appropriate international coordination and standardization. This paper reviews developments and applications of the GPS common-view method during the last decade and comments on possible future improvements whose objective is to attain sub-nanosecond uncertainty.

Lewandowski, W.↗

Precise Measurements of the Density and Critical Phenomena Near Phase Transitions in Liquid Helium

The first-year progress for the project of precise measurements of the density and critical phenomena of helium near phase transitions is summarized below: (1) completion of a cryogenic sample probe for the proposed measurements, and the rehabilitation of a designated laboratory at Caltech for this project; (2) construction and testing of a superconducting niobium cavity; (3) acquisition of one phase-locked-loop system for high-resolution frequency control and read- out; (4) setting up high-resolution thermometry (HRT) for temperature readout and control; (5) developing new approaches for calibrating the coefficient between the resonant frequency shift (delta f) and the helium density (rho), as well as for measuring the effect of gravity on T(sub lambda) to a much better precision; (6) programming of the interface control of all instruments for automatic data acquisition; and (7) improving data analyses and fitting procedures.

Yeh, Nai-Chang↗

Precision Timing in CMS at the HL-LHC: Current Progress on Validation and Production

During the High Luminosity phase of LHC, up to 200 proton-proton collisions per bunch crossing will bring severe challenges for event reconstruction. To mitigate pileup effects, an extended upgrade program of the CMS experiment is expected. Among which, a new timing layer, the MIP Timing Detector (MTD), will be integrated between the tracker and the calorimeters. With a time resolution of 30-60 ps, the MTD will enable 4D vertexing, bringing significant improvements in track-to-vertex association and object identification. The MTD is composed of two subsystems based on different technologies: the Barrel Timing Layer (BTL) consists of LYSO:Ce scintillating crystals readout by SiPMs, and the Endcap Timing Layer (ETL) is made of Low-Gain Avalanche Diodes. The BTL is currently under production, while ETL sensor prototyping and validation are ongoing. Recent system tests have confirmed the performance of the full acquisition chain. This talk will provide an overview of the MTD design, along with the physics motivation, and the current status of BTL construction and ETL development.

Safdari, Murtaza [Fermilab] (ORCID:000000018323731↗

A comparison of satellite systems for gravity field measurements

A detailed and accurate earth gravity field model is important both to geophysical progress and to the precise tracking necessary for interpretation of geophysical experiments. Various satellite techniques which may be used to determine the earth's gravity field are compared and their ability to recover the long wavelength and short wavelength features of the field are described. A high-low configuration satellite-to-satellite tracking mission is recommended for the determination of the long wavelength portion of the gravity field. Satellite altimetry and satellite gradiometry experiments are recommended for determination of the short wavelength portion of the gravity field.

Argentiero, P.↗

TPCpp-10M: Simulated proton-proton collisions in a time projection chamber for AI foundation models

Scientific foundation models hold great promise for advancing nuclear and particle physics by improving analysis precision and accelerating discovery. Yet, progress in this field is often limited by the lack of openly available large scale datasets, as well as standardized evaluation tasks and metrics. Furthermore, the specialized knowledge and software typically required to process particle physics data pose significant barriers to interdisciplinary collaboration with the broader machine learning community. This work introduces a large, openly accessible dataset of 10 million simulated proton-proton collisions, designed to support self-supervised training of foundation models. To facilitate ease of use, the dataset is provided in a common NumPy format. In addition, it includes 70,000 labeled examples spanning three well defined downstream tasks: track finding, particle identification, and noise tagging, to enable systematic evaluation of the foundation model's adaptability. The simulated data are generated using the Pythia Monte Carlo event generator at a center of mass energy of $\sqrt{s}$ = 200 GeV and processed with Geant4 to include realistic detector conditions and signal emulation in the sPHENIX Time Projection Chamber at the Relativistic Heavy Ion Collider, located at Brookhaven National Laboratory. This dataset resource establishes a common ground for interdisciplinary research, enabling machine learning scientists and physicists alike to explore scaling behaviors, assess transferability, and accelerate progress toward foundation models in nuclear and high energy physics. The complete simulation and reconstruction chain is reproducible with the sPHENIX software stack. All data and code locations are provided under Data Accessibility.

Data Analysis, Statistics and Probability (physics↗

Polaritonic Bright and Dark States Collectively Affect the Reactivity of a Hydrolysis Reaction

Vibrational strong coupling (VSC) has emerged as a means for modifying chemical reactivity. Despite the intriguing discoveries and progresses in the field, the precise mechanisms that govern polaritonic chemistry still deserve further interrogation. Herein, we use the hydrolysis of ammonia borane in D 2 O as an exemplary reaction and systematically investigate the influence of VSC on its reactivity. Experimental evidence of the coexistence of a resonant effect and reaction acceleration is observed in this system. In particular, we find that when the O-D stretching mode of D 2 O is strongly coupled to a cavity mode, reaction acceleration is observed. The reaction rate acceleration factor, mu, is consistently observed to be dependent on the coupling conditions between the vibrational and cavity modes, and reaches a minimum at zero mode detuning, suggesting that a resonant effect is likely in play. In addition, we find that mu decreases with an increasing Rabi splitting. Based on these experimental findings, we propose that the overall influence of VSC on this reaction is likely determined collectively by the polaritonic bright and dark states. In conclusion, these findings could help shed new light on the intricate effects of VSC on ground-state reaction landscapes.

Rabi splitting↗