Search NASA⌕ Search

SEARCH · Search NASA

Results for “protection system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Cyber-Physical Power Systems Protection: The Byzantine Cybersecurity Framework

Cybersecurity of smart grids have been topic of much interest in recent years. As this critical infrastructure operation increases dependency on automated processes and controls, exposure to cyber-physical threats become inevitable. Considering cyber-physical security of the grid, much focus of attention has been made towards smart grids real-time monitoring solutions, including the state estimation process. Analyzing the relevant literature, one can note though that seldom research has been done on cyber-physical security of smart grids protection systems. Protection systems have intangible value towards grid reliability. This paper presents a cybersecurity framework for smart grids protection systems. A physics-based inspired machine learning solution is at the core process of the framework. Processed relay inputs and outputs are used by a deep predictive coding network. Formal models, a quasi-static state estimator, provides an oracle when low confidence decision is reached. Evolving knowledge is derived through reinforcement learning. Implementation aspects considering the Pacific Northwest National Laboratory Electricity Infrastructure Operations Center are presented. Built as an extra control layer to protection systems, without hard-to-derive parameters, highlights potential aspects towards real-life applications.

Bretas, Arturo Suman↗

Validating Protection System Behavior with Machine Learning in a Master State Overseer

As power system protection devices continue the widespread transition from analog to digital, they become increasingly intricate. The internal functions and communication between critical grid components must now be significantly more complex to keep up with the demands of the modern smart grid. This brings increased difficulty in maintenance and monitoring, making it harder to identify potential misoperation, power anomalies, and cyber threats. Such issues are often only pinpointed after an exhaustive and costly post-mortem analysis, when a major outage or damage has already occurred. A solution is needed for validating protection systems as they operate, independently evaluating grid state and confirming whether the protection system is behaving accordingly. As opposed to incident response, this acts as a constant verification mechanism that raises a flag when subtler issues are noticed, catching them earlier and preventing larger incidents. This work presents the implementation of such a system, expanding on the prototype developed by the authors in a previous paper. This is accomplished with a machine learning (ML) system capable of validating the performance of protection systems by classifying anomalous events and characterizing protection system responses based solely on available current and voltage measurements. Additionally, this system is contextualized within a larger, modular Master State awareness Overseer (MSO) framework, responsible for monitoring, analyzing, and managing an electric grid.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Protection System Validation with Machine Learning Anomaly Classification

A poster for the Early Career Poster Session. Power system protection devices have transitioned over the past few decades from mechanical to analog devices, then to solid state and finally digital. Relays and their associated critical network of equipment have significantly increased in complexity. Even internally, relays have gained significant intricacy, with relatively simple overcurrent or differential functions now being assisted by a myriad of other functions. This is necessary as the grid becomes more complex, but it brings increased difficulty in monitoring and upkeep. Misoperation caused by improper relay settings or malicious actions is a constant challenge faced by all utilities. These improper settings can be difficult to identify and may require exhaustive post-mortem analysis, typically after a major outage event has already occurred. A mechanism is needed for monitoring the behavior of protection systems to validate that they act and perform as expected. This work presents a concept for a machine learning (ML) system capable of validating the performance of protection systems by classifying anomalous events and characterizing protection system responses based solely on available current and voltage measurements. As a first step in its development, an experimental dataset is generated, and a random forest model is implemented with high accuracy in distinguishing four power system scenarios.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Protection System Validation Using Post-Event Anomaly Classification with Machine Learning

Power system protection devices have transitioned over the past few decades from mechanical to analog devices, then to solid state and finally digital. Relays and their associated critical network of equipment have significantly increased in complexity. Even internally, relays have gained significant intricacy, with relatively simple overcurrent or differential functions now being assisted by a myriad of other functions. This is necessary as the grid becomes more complex, but it brings increased difficulty in monitoring and upkeep. Misoperation caused by improper relay settings or malicious actions is a constant challenge faced by all utilities. These improper settings can be difficult to identify and may require exhaustive post-mortem analysis, typically after a major outage event has already occurred. A mechanism is needed for monitoring the behavior of protection systems to validate that they act and perform as expected. This work presents a concept for a machine learning (ML) system capable of validating the performance of protection systems by classifying anomalous events and characterizing protection system responses based solely on available current and voltage measurements. As a first step in its development, an experimental dataset is generated, and a random forest model is implemented with high accuracy in distinguishing four power system scenarios.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Post-Event Fault Identification with Machine Learning for Protection System Validation

Power system protection devices have transitioned over the past few decades from mechanical to analog devices, then to solid state and finally digital. Relays and their associated critical network of equipment have significantly increased in complexity. Even internally, relays have gained significant intricacy, with relatively simple overcurrent or differential functions now being assisted by a myriad of other functions. This is necessary as the grid becomes more complex, but it brings increased difficulty in monitoring and upkeep. Misoperation caused by accidental improper relay settings or deliberate malicious actions is a constant challenge faced by all utilities. These improper settings can be difficult to identify and may require exhaustive post-mortem analysis, typically after a major outage event has already occurred. A mechanism is needed for monitoring the behavior of protection systems to validate that their performance falls within expectations. Relays that fail to isolate a fault or trip when there is no system disturbance can be flagged for settings review in situations where this behavior may not have been noticed due to manual restoration or backup protection operations. This work presents a concept for a machine learning (ML) system capable of validating the performance of protection systems by identifying fault events and characterizing protection system responses based solely on available current and voltage measurements. As a first step in its development, an experimental dataset is generated, and a random forest model is implemented with high accuracy in distinguishing four power system scenarios.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Systems and Implementation: Integrating Unmanned Aircraft Systems into Physical Protection Systems at Fixed Sites and During Transportation

Physical protection systems, and response forces in particular, are designed to prevent an adversary from successfully completing a malevolent act against a facility or transport operations. Timely detection and assessment of any potential adversary action against a target is an essential element of materials security. The timely detection and assessment must then be followed-up by a capable and timely response that might be enhanced with the additional situational awareness provided by unmanned aircraft systems (UAS). The United States Department of Energy’s National Nuclear Security Administration Office of International Nuclear Security has been exploring capabilities provided by UAS to support response force operations within the physical protection system. UAS have the potential to provide response force commanders and operators with situational awareness in assessing adversary locations and actions as well as the locations of responders. UAS may be utilized for area searches ahead of responder pathways to identify potential threats and to provide situational awareness of areas not normally covered by cameras (such as areas outside the fence line outside at fixed facilities). In addition, UAS can provide real-time information to transportation convoy teams that pass through constantly changing public access environments. This paper will provide operational recommendations to be addressed when integrating UAS into existing physical protection systems at fixed sites and during transport. Recommendations will include aspects of the following: needs analysis; tactics and techniques to support detection and assessment as well as response force deployment; remote pilot selection, qualifications, training, and currency; UAS selection criteria; UAS laws and regulations; possible cost sharing with other facility operations; and on-scene emergency management.

Stockwell, Brandon↗

ByzSec — A Multi-layered Byzantine Resilient Architecture for Bulk Power System Protective Relays

Reliability, selectivity, and sensitivity are the fundamental attributes of any protection system, acting as the main drivers in the selection of schemes, and equipment. In high-voltage systems, microprocessor-based relays represent the industry’s preferred solution, providing engineers with a vast array of benefits. However, they remain vulnerable to cybersecurity events that may compromise their functionality. To help mitigate against potential cybersecurity risks, this paper presents a fault-tolerant, Byzantine Resilient (BR) architecture that significantly increases the cybersecurity attributes of a protection system while minimizing the amount of performance impacts and integration overheads introduced. The solution relies on an array of independent relays that utilize robust consensus methods (based on Spire [1], [2]) to ensure correct system behavior is achieved even when a relay has been compromised. Furthermore, the solution has been complemented with a custom-built Situational Awareness engine that can be used to detect and identify potential threats. The implemented solution has been developed in consultation with three hardware vendors and has been tested to comply with the performance requirements of a 345kV differential protection scheme (87T). The results indicate that the proposed architecture is a comprehensive solution that: supports the strict correctness and performance requirements of the bulk power grid while providing a cost-effective alternative that offers a seamless, long-term solution.

byzantine security, Fault Tolerant Application Sof↗

Fermilab PIP-II machine protection system digitized data noise elimination scheme and its FPGA implementation

In Fermilab's PIP-II machine protection system, beam loss signals from various detectors are digitized at 125 MS/s. Noise from both high-frequency sources and low-frequency 60 Hz AC power equipment can contaminate the data. To suppress noise across these ranges—especially 60 Hz and its harmonics, which overlap with beam loss signal frequencies—advanced digital processing beyond standard filtering is required. Several real-time functional blocks were simulated and tested on an FPGA: (1) a dual time-constant discharging integrator filter, (2) a de-ripple baseline extraction and storage block, and (3) a fast-recovery discharging integrator. The nonlinear IIR integrator filter removes high-frequency noise and feeds into the baseline extractor. Upon detecting abrupt beam loss, it switches to a longer time constant to prevent baseline distortion. The de-ripple block calculates a valid baseline by averaging over multiple 60 Hz periods, storing results in a 4096-word FPGA RAM. This baseline is subtracted from raw data before integration by the fast-recovery block, which resets quickly after use. All blocks achieved expected performance and were successfully implemented on a low-cost FPGA.

Wu, Jinyuan [Fermilab]↗

Development of scalable design optimization parameters for bi-component protective systems

Bi-component protection-systems need to withstand a variety of extreme loading conditions such as high-velocity projectile impact to shock and blast mitigation. The large number of parameters at each stage of bi-component protection system design process results in a near-infinite number of possible variables for optimization. The aim of this project is to identify the scaling laws linking material and geometric scales of the problem to the final impact performance, further including the effects of wave propagation/interaction and inter-component bonding. Specifically, the impact dynamics for different optimal projectile/target density ratios and relative component mass fractions are quantified for bonded ceramic/titanium alloy systems. The impact behavior such as wave mechanics and damage propagation within the target system is characterized and quantified via digital image correlation or via x-ray phase-contrast imaging.

36 MATERIALS SCIENCE↗

A Risk-Informed Performance-Based Methodology to Manage Fire Protection Systems in Nuclear Facilities

Fire protection systems (FPSs) and features are installed in U.S. Department of Energy (DOE) Hazard Category 1, 2, or 3 nuclear facilities to protect property (maximum possible fire loss thresholds), life, and nuclear safety (i.e., structures, systems, and components). These FPSs and features are designed and maintained in accordance with the prescriptive guidance provided in applicable building codes and National Fire Protection Association codes and standards. Management, operations, and maintenance activities of FPSs involve significant effort. A DOE facility’s documented safety analysis or other safety basis document could also rely on FPSs to provide either a safety significant or safety class function to mitigate fire hazards and minimize radiological consequences. In some cases, the designation of safety significant or safety class may be determined to provide a layer of defense-in-depth to minimize nuclear safety risks independent of the fire risk. DOE standards allow the use of performance-based design alternatives developed by the fire industry but do not consider the defense-in-depth layers of protection provided in DOE facilities to prevent or mitigate the risks associated with unintended release of radioactive materials into the environment. Pacific Northwest National Laboratory developed a decision-making methodology tailored for DOE non-reactor nuclear facilities to manage FPSs and features by integrating nuclear safety risk insights into a performance-based analysis. This risk-informed, performance-based (RIPB) methodology can be used to provide the technical basis for classifying an FPS as safety class and safety significant, tailoring administrative controls (e.g., technical safety requirements), and ranking the importance of FPSs to prioritize maintenance, upgrades, and replacement activities. The RIPB methodology is a graded approach to inform DOE facility owners and Fire Protection Program managers of the most risk-significant FPSs and equipment, and those systems would be cost-beneficial to relax rigor if there is a need to re-design the FPS coverage or deviate from DOE and National Fire Protection Association standards for those systems that would be less significant. This paper describes the framework used to develop the RIPB methodology and the outcome of implementing this methodology in a use-case nuclear facility. This paper also discusses the impact to DOE policies and standards and the safety margins and defense-in-depth measures credited in nuclear safety assessments in a facility’s documented safety analysis and the benefits of implementing an RIPB methodology in lieu of a prescriptive method to comply with fire protection requirements.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Agent-based simulation and child protection systems: Rationale, implementation, and verification

Simulation models are an important tool used in health care and other disciplines to support operational research and decision-making. In the child protection literature, simulation models are an under-utilized source of research evidence. Here, in this paper, we describe the rationale for and the development of an agent-based simulation of a child protection system in the US. Using the investigation, prevention service, and placement histories of 600,000 children served in an urban child welfare system, we walk the reader through the development of a prototype known as OSPEDALE. The governing equations built into OSPEDALE probabilistically simulate the onset of investigations. Then, drawing from empirical survival distributions, the governing equations trace the probability of subsequent interactions with the system (recurrence of maltreatment, service referrals, and placement) conditional on the characteristics of children, their assessed risk level, and prior child protection system involvement. As an initial test of OSPEDALE's utility, we compare empirical admission counts with counts generated from OSPEDALE. Though the verification step is admittedly simple, the comparison shows that OSPEDALE replicates the empirical count of new admissions closely enough to justify further investment in OSPEDALE. Management of public child protection systems is increasingly research evidence-dependent. The emphasis on research evidence as a decision-support tool has elevated evidence acquired through randomized clinical trials. Though important, the evidence from clinical trials represents only one type of research evidence. Properly specified, simulation models are another source of evidence with real-world relevance.

60 APPLIED LIFE SCIENCES↗

Software and Firmware-logic Design for the PIP-II Machine Protection System Mode and Configuration Control at Fermilab

The PIP-II Machine Protection System (MPS) requires a dedicated set of tools for configuration control and management of the machine modes and beam modes of the accelerator. The protection system reacts to signals from various elements of the machine according to rules established in a setup database in the form of a Look-Up-Table filtered by the program Mode Controller. This is achieved in accordance with commands from the operator and governed by the firmware logic of the MPS. This paper describes the architecture, firmware logic, and implementation of the program mode controller.

43 PARTICLE ACCELERATORS↗

Sierra Space Technology Collaboration-Advanced Manufacturing of Thermal Protection System Tiles for Space Plane Atmospheric Reentry

Thermal protection systems (TPS) constitute a major material, engineering, and manufacturing challenge for space access. Atmospheric re-entry generates very high heats and requires advanced materials to withstand such conditions. Combining the required materials and integrating them into the vehicle is a major engineering undertaking that often must use creative designs to accommodate the selected materials and systems. Likewise, the manufacture of TPS is costly and challenging; it requires a combination of materials in a range of complex and unique shapes with specialized process conditions. Compounding these challenges, for harsh re-entry profiles or on high heat flux regions of the vehicle, even state of the art TPS is effectively single use and thereby creating a strong economic incentive to improve the TPS materials, integration, and manufacture. This work focuses on the use of ceramic modifications to TPS materials thereby allowing multi flight capability.

99 GENERAL AND MISCELLANEOUS↗

Reducing the Overnight Capital Cost of Advanced Reactors Using Equipment-Level Seismic Protective Systems

Consideration of the effects of earthquake shaking on the design and construction of nuclear power plants adds substantially to the overnight capital cost, with anecdotal estimates as high as 35+%, attributed to additional construction materials, need for one-off and sub-optimal designs of equipment due to conflicting design choices, the high cost of seismic qualification of equipment, and regulatory review. Safety-critical equipment in large light water reactors is designed and qualified for seismic demands imposed by the supporting reactor building, optimal mechanical designs are not possible, and designs of a given piece of equipment may vary with height above grade. Similar negative impacts are expected for advanced reactors unless the seismic design paradigm is changed. The overarching goal of this transformational MEITNER project, which involved a multidisciplinary engineering team and designers of three fundamentally different advanced reactors, was to adapt proven seismic isolation and damping technologies to operationalize modular protective systems for safety-class equipment inside advanced reactor buildings. Such seismic protective systems would be tightly integrated into design development for reactor support systems and balance-of-plant construction. The adoption of the technology, which is widely used in non-nuclear sectors, would simplify plant design, enable the use of standardized equipment and buildings, optimized for operational performance, and reduce plant size and weight. The need for site-specific equipment would be eliminated, enabling identical equipment to be used across multiple plants sited across the US and economies of scale, and catalyzing new interest and investment. The equipment-based protective systems would allow siting of advanced reactors in regions of high seismic hazard.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Advanced Manufacturing of Thermal Protection System Tiles for Space Plane Atmospheric Reentry

Thermal protection systems (TPS) constitute a major material, engineering, and manufacturing challenge for space access. Atmospheric re-entry generates very high heats and requires advanced materials to withstand such conditions. Combining the required materials and integrating them into the vehicle is a major engineering undertaking that often must use creative designs to accommodate the selected materials and systems. Likewise, the manufacture of TPS is costly and challenging; it requires a combination of materials in a range of complex and unique shapes with specialized process conditions. Compounding these challenges, for harsh re-entry profiles or on high heat flux regions of the vehicle, even state of the art TPS is effectively single use and thereby creating a strong economic incentive to improve the TPS materials, integration, and manufacture. This work focuses on the use of ceramic modifications to TPS materials thereby allowing multi flight capability.

36 MATERIALS SCIENCE↗

Machine-Protection System for the PIP-II Linear Accelerator: Architecture and Data Processing Schemes

PIP-II at Fermilab features a brand-new, 800 MeV leading-edge Linear Accelerator (Linac) that will enable the Fermilab complex to deliver more than a megawatt of beam power to the Long Base-line Neutrino Facility (LBNF), requiring a robust Machine Protection System (MPS) to prevent beam-induced damage to delicate cryomodules and vacuum components. Signals in various accelerator components, in both analog and digital format, are collected and processed to assest the operating conditions of the accelerator. In the situation a potential damage is foreseen, the beam permit signal will be drop. A critical element of this system is the fast Analog Machine Protection System, a high-bandwidth platform designed for real-time beam loss monitoring. The system utilizes a modular, FPGA-based architecture to digitize signals from beam-sensing devices, such as AC Current Transformers (ACCTs), non-invasive Ring Pickups (RPUs) and beam scrapers. To eliminate both high frequency as well as 60 Hz noise that might be picked up in the industrial environment, data processing schemes beyond regular digital filtering are planned and implemented.

Wu, Jinyuan [Fermilab] (ORCID:0000000344329521)↗