Search NASA⌕ Search

SEARCH · Search NASA

Results for “proton transmission”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Geomagnetic transmission of solar energetic protons during the geomagnetic disturbances of October 1989

Orbit-averaged geomagnetic transmission measurements during the large solar energetic particle events of October 1989 are presented using proton data from the NOAA-10 and GOES-7 satellies. The measurements are compared to geomagnetic transmission calculations determined by tracing particle trajectories through the combination of the International Geomagnetic Reference Field (IGRF) model and the 1989 Tsyganenko magnetospheric magnetic field model. The effective 'ring current' parameter in the 1989 Tsyganenko model based on the Dst data. Results are compared to calculations employing only the IGRF and to a parameterization of geomagnetically quiet-time cutoff rigidities derived from Cosmos/intercosmos observations. The 3-hour orbit-averaged results have approximately 15% accuracy during the October 1989 events.

Boberg, P. R.↗

Proton-induced degradation of VUV transmission of LiF and MgF2

Proton-induced degradation of vacuum ultraviolet (VUV) transmittance of LiF and MgF2 was measured for 85- and 600-MeV protons for a fluence up to 2.8 x 10 to the 13th p/sq cm. Transmittances were measured from 105 to 210 nm. When the irradiation level for a given material is expressed in terms of absorbed energy per unit of volume of crystal, 85- and 600-MeV protons produce the same degradation. MgF2 is substantially more radiation resistant than LiF in the VUV. Irradiation of LiF with 1.8 x 10 to the 13th p/sq cm at 85 MeV changed the transmittance of the hydrogen Ly-alpha line at 121.6 nm from 55 to 23%. The corresponding change for MgF2 was from 52 to 42% for 2.8 x 10 to the 13th p/sq cm.

Reft, C. S.↗

In Vitro Studies on Space Radiation-Induced Delayed Genetic Responses: Shielding Effects

Understanding the radiation risks involved in spaceflight is of considerable importance, especially with the long-term occupation of ISS and the planned crewed exploration missions. Several independent causes may contribute to the overall risk to astronauts exposed to the complex space environment, such as exposure to GCR as well as SPES. Protons and high-Z energetic particles comprise the GCR spectrum and may exert considerable biological effects even at low fluence. There are also considerable uncertainties associated with secondary particle effects (e.g. HZE fragments, neutrons etc.). The interaction of protons and high-LET particles with biological materials at all levels of biological organization needs to be investigated fully in order to establish a scientific basis for risk assessment. The results of these types of investigation will foster the development of appropriately directed countermeasures. In this study, we compared the biological responses to proton irradiation presented to the target cells as a monoenergetic beam of particles of complex composition delivered to cells outside or inside a tissue phantom head placed in the United States EVA space suit helmet. Measurements of chromosome aberrations, apoptosis, and the induction of key proteins were made in bone marrow from CBA/CaJ and C57BL/6 mice at early and late times post exposure to radiation at 0, 0.5, 1 and 2 Gy while inside or outside of the helmet. The data showed that proton irradiation induced transmissible chromosomal/genomic instability in haematopoietic stem cells in both strains of mice under both irradiation conditions and especially at low doses. Although differences were noted between the mouse strains in the degree and kinetics of transforming growth factor-beta 1 and tumor necrosis factor-alpha secretion, there were no significant differences observed in the level of the induced instability under either radiation condition, or for both strains of mice. Consequently, when normalized to physical dose, the monoenergetic proton field present inside the helmet-protected phantom produced equivalent biological responses, when compared to unshielded cells, as measured by the induction of delayed genetic effects in murine haematopoietic stem cells.

Kadhim, Munira A.↗

Proton flare and magnetic storm effect in the vicinity of the Earth

We have developed a model and associated computational procedure for estimating energetic proton exposures during a major solar proton event that occur in combination with a large magnetic storm. Transmission functions for solar protons are computed using geomagnetic vertical cutoff data for quiescent amd disturbed conditions. Predicted exposures in low altitude polar orbit are found to be orders of magnitude greater for severe magnetic storm conditions than are corresponding exposures in the absence of major disturbances. We examine the response scenario for the events of November 1960 as an example.

Nealy, J. E.↗

Simulation of the Charged Particle Deflection From the Sweeping Magnet Array in the Lunar Environment Heliospheric X-Ray Imager

The Lunar Environment heliospheric X-ray Imager (LEXI) is an instrument built to image x-rays from solar wind charge exchange in Earth’s magneto sheath. Monitoring the position of the magnetopause at the inner boundary of the magneto sheath allows us to understand how magnetic reconnection regulates how energy from the solar wind is deposited into Earth’s magnetosphere. LEXI is part of an upcoming lunar lander mission set to land in Mare Crisium. To repel unwanted charged particles, the instrument carries a permanent magnet array composed of 48 neodymium magnets. The array was designed to maximize charged particle deflection while minimizing stray magnetic fields, which could impact other instruments or spacecraft operation. A Runge–Kutta-based fully kinetic particle tracing model was created to evaluate the effectiveness of LEXI’s unique charged particle deflector array. Combined with the other particle suppression measures of the instrument, including physical structures and filters, the simulations show proton and electron transmission to the LEXI detector is expected to be sufficiently reduced to allow successful imaging. The flexible simulation model can be generalized to be used in examining the magnetic deflector array effectiveness of other instruments whose signals could be compromised by unwanted charged particle contamination.

Space environment effects↗

Shock Acceleration of Solar Energetic Protons: The First 10 Minutes

Proton acceleration at a parallel coronal shock is modeled with self-consistent Alfven wave excitation and shock transmission. 18 - 50 keV seed protons at 0.1% of plasma proton density are accelerated in 10 minutes to a power-law intensity spectrum rolling over at 300 MeV by a 2500km s-1 shock traveling outward from 3.5 solar radius, for typical coronal conditions and low ambient wave intensities. Interaction of high-energy protons of large pitch-angles with Alfven waves amplified by low-energy protons of small pitch angles is key to rapid acceleration. Shock acceleration is not significantly retarded by sunward streaming protons interacting with downstream waves. There is no significant second-order Fermi acceleration.

Ng, Chee K.↗

Friction and Wear Properties of As-deposited and Carbon Ion-implanted Diamond Films

Recent work on the friction and wear properties of as-deposited and carbon ion-implanted diamond films was reviewed. Diamond films were produced by the microwave plasma chemical vapor deposition (CVD) technique. Diamond films with various grain sizes and surface roughnesses were implanted with carbon ions at 60 ke V ion energy, resulting in a dose of 1.2310(exp 17) carbon ions/cm(exp 2). Various analytical techniques, including Raman spectroscopy, proton recoil analysis, Rutherford backscattering, transmission and scanning electron microscopy, x-ray photoelectron spectroscopy, and x-ray diffraction, were utilized to characterize the diamond films. Sliding friction experiments were conducted with a polished natural diamond pin in contact with diamond films in the three environments: humid air (40 percent relative humidity), dry nitrogen (less than 1 percent relative humidity), and ultrahigh vacuum (10(exp -7) Pa). The CVD diamond films indeed have friction and were properties similar to those of natural diamond in the three environments. The as-deposited, fine-grain diamond films can be effectively used as self-lubricating, wear-resistant coatings that have low coefficients of friction (0.02 to 0.04) and low wear rates (10(exp -7) to 10(exp -8)mm(exp 3)/N-m) in both humid air and dry nitrogen. However, they have high coefficients of friction (1.5 to 1.7) and a high wear rate (10(exp -4)mm(exp 3/N-m) in ultrahigh vacuum. The carbon ion implanation produced a thin surficial layer (less than 0.1 micron thick) of amorphous, nondiamond carbon on the diamond films. In humid air and dry nitrogen, the ion-implanted, fine- and coarse-grain diamond films have a low coefficient of friction (around 0.1) and a low wear rate (10(exp -7)mm(exp 3/N-m). Even in ultrahigh vacuum, the presence of the nondiamond carbon layer reduced the coefficient of friction of fine-grain diamond films to 0.1 or lower and the wear rate to 10(exp -6)mm(exp 3)/N-m. Thus, the carbon ion-implanted, fine-grain diamond films can be effectively used as wear-resistant, self-lubricating coatings not only in air and dry nitrogen, but also in ultrahigh vacuum. The wear mechanism of diamond films is that of small fragments chipping off the surface. The size of wear particles is related to the extent of wear rates.

Miyoshi, Kazuhisa↗

Friction and Wear Properties of As-Deposited and Carbon Ion-Implanted Diamond Films

Recent work on the friction and wear properties of as-deposited and carbon ion-implanted diamond films was reviewed. Diamond films were produced by the microwave plasma chemical vapor deposition (CVD) technique. Diamond films with various grain sizes and surface roughnesses were implanted with carbon ions at 60 keV ion energy, resulting in a dose of 1.2 x 10(exp 17) carbon ions per cm(exp 2). Various analytical techniques, including Raman spectroscopy, proton recoil analysis, Rutherford backscattering, transmission and scanning electron microscopy, X-ray photoelectron spectroscopy, and X-ray diffraction, were utilized to characterize the diamond films. Sliding friction experiments were conducted with a polished natural diamond pin in contact with diamond films in the three environments: humid air (40% relative humidity), dry nitrogen (less than 1 percent relative humidity), and ultrahigh vacuum (10(exp -7) Pa). The CVD diamond films indeed have friction and wear properties similar to those of natural diamond in the three environments. The as-deposited, fine-grain diamond films can be effectively used as self-lubricating, wear-resistant coatings that have low coefficients of friction (0.02 to 0.04) and low wear rates (10(exp -7) to lO(exp -8) mm(exp 3) N(exp -1) m(exp -1)) in both humid air and dry nitrogen. However, they have high coefficients of friction (1.5 to 1.7) and a high wear rate (10(exp -4) mm(exp 7) N(exp -1) m(exp -1)) in ultrahigh vacuum. The carbon ion implantation produced a thin surficial layer (less than 0.1 micron thick) of amorphous, non-diamond carbon on the diamond films. In humid air and dry nitrogen, the ion-implanted, fine and coarse-grain diamond films have a low coefficient of friction (around 0.1) and a low wear rate (10(exp -7) mm(exp 3) N(exp -1) m(exp-1)). Even in ultrahigh vacuum, the presence of the non-diamond carbon layer reduced the coefficient of friction of fine-grain diamond films to 0.1 or lower and the wear rate to 10(exp -6) mm(exp 3) N(exp -1) m(exp -1). Thus, the carbon ion-implanted, fine-grain diamond films can be effectively used as wear-resistant, self-lubricating coatings not only in air and dry nitrogen, but also in ultrahigh vacuum.

Miyoshi, Kazuhisa↗

An Analytical Model for the Prediction of a Micro-Dosimeter Response Function

A rapid analytical procedure for the prediction of a micro-dosimeter response function in low Earth orbit (LEO), correlated with the Space Transportation System (STS, shuttle) Tissue Equivalent Proportional Counter (TEPC) measurements is presented. The analytical model takes into consideration the energy loss straggling and chord length distribution of the detector, and is capable of predicting energy deposition fluctuations in a cylindrical micro-volume of arbitrary aspect ratio (height/diameter) by incoming ions through both direct and indirect (ray) events. At any designated (ray traced) target point within the vehicle, the model accepts the differential flux spectrum of Galactic Cosmic Rays (GCR) and/or trapped protons at LEO as input. On a desktop PC, the response function of TEPC for each ion in the GCR/trapped field is computed at the average rate of 30 seconds/ion. The ionizing radiation environment at LEO is represented by O'Neill fs GCR model (2004), covering charged particles in the 1 less than or equal to Z less than or equal to 28. O'Neill's free space GCR model is coupled with the Langley Research Center (LaRC) angular dependent geomagnetic cutoff model to compute the transmission coefficient in LEO. The trapped proton environment is represented by a LaRC developed time dependent procedure which couples the AP8MIN/AP8MAX, Deep River Neutron Monitor (DRNM) and F10.7 solar radio frequency measurements. The albedo neutron environment is represented by the extrapolation of the Atmospheric Ionizing Radiation (AIR) measurements. The charged particle transport calculations correlated with STS 51 and 114 flights are accomplished by using the most recent version (2005) of the LaRC deterministic High charge (Z) and Energy TRaNsport (HZETRN) code. We present the correlations between the TEPC model predictions (response function) and TEPC measured differential/integral spectra in the lineal energy (y) domain for both GCR and trapped protons, with the conclusion that the model correctly accounts for the increase in flux at low y values where energetic ions are the primary contributor. We further discuss that, even with the incorporation of angular dependency in the cutoffs, comparison of the GCR differential/integral flux between STS 51 and 114 TEPC measured data and current calculations indicates that there still exists an underestimation by the simulations at low to mid range y values. This underestimation is partly related the exclusion of the secondary pion particle production from the current version of HZETRN.

Badavi, Francis F.↗

Radiation Transport Properties of Potential In Situ-Developed Regolith-Epoxy Materials for Martian Habitats

We will evaluate the radiation transport properties of epoxy-martian regolith composites. Such composites, which would use both in situ materials and chemicals fabricated from elements found in the martian atmosphere, are candidates for use in habitats on Mars. The principal objective is to evaluate the transmission properties of these materials with respect to the protons and heavy charged particles in the galactic cosmic rays which bombard the martian surface. The secondary objective is to evaluate fabrication methods which could lead to technologies for in situ fabrication. The composites will be prepared by NASA Langley Research Center using simulated martian regolith. Initial evaluation of the radiation shielding properties will be made using transport models developed at NASA-LaRC and the results of these calculations will be used to select the composites with the most favorable radiation transmission properties. These candidates will then be empirically evaluated at particle accelerators which produce beams of protons and heavy charged particles comparable in energy to the radiation at the surface of Mars.

Miller, J.↗

Introduction to Radiation Issues for International Space Station Extravehicular Activities

The International Space Station (ISS) provides significant challenges for radiation protection of the crew due to a combination of circumstances including: the extended duration of missions for many crewmembers, the exceptionally dynamic nature of the radiation environment in ISS orbit, and the necessity for numerous planned extravehicular activities (EVA) for station construction and maintenance. Radiation protection requires accurate radiation dose measurements and precise risk modeling of the transmission of high fluxes of energetic electrons and protons through the relatively thin shielding provided by the space suits worn during EVA. Experiments and analyses have been performed due to the necessity to assure complete radiation safety for the EVA crew and thereby ensure mission success. The detailed characterization described of the material and topological properties of the ISS space suits can be used as a basis for design of space suits used in future exploration missions. In radiation protection practices, risk from exposure to ionizing radiation is determined analytically by the level of exposure, the detrimental quality of the radiation field, the inherent radiosensitivity of the tissues or organs irradiated, and the age and gender of the person at the time of exposure. During low Earth orbit (LEO) EVA, the relatively high fluxes of low-energy electrons and protons lead to large variations in exposure of the skin, lens of the eye, and tissues in other shallow anatomical locations. The technical papers in this publication describe a number of ground-based experiments that precisely measure the thickness of the NASA extravehicular mobility unit (EMU) and Russian Zvezda Orlan-M suits using medical computerized tomography (CT) X-ray analysis, and particle accelerator experiments that measure the minimum kinetic energy required by electrons and photons to penetrate major components of the suits. These studies provide information necessary for improving the understanding of the current ISS space suits and provide insights into improved approaches for the design of future suits. This chapter begins with a summary of the dynamic ionizing radiation environment in LEO space and introduces the concepts and quantities used to quantify exposure to space radiation in LEO. The space suits used for EVA and the experimental partial human phantom are described. Subsequent chapters report results from measured charged particle fields before and after incident protons and secondary particles are transported through the space suits and into organs and tissues.

Shavers, M. R.↗

Shuttle Spacesuit: Fabric/LCVG Model Validation

A detailed spacesuit computational model is being developed at the Langley Research Center for radiation exposure evaluation studies. The details of the construction of the spacesuit are critical to estimation of exposures and assessing the risk to the astronaut on EVA. Past evaluations of spacesuit shielding properties assumed the basic fabric lay-up (Thermal Micrometeroid Garment, fabric restraints, and pressure envelope) and Liquid Cooling and Ventilation Garment (LCVG) could be homogenized as a single layer overestimating the protective properties over 60 percent of the fabric area. The present spacesuit model represents the inhomogeneous distributions of LCVG materials (mainly the water filled cooling tubes). An experimental test is performed using a 34-MeV proton beam and highresolution detectors to compare with model-predicted transmission factors. Some suggestions are made on possible improved construction methods to improve the spacesuit's protection properties.

Wilson, J. W.↗

Shuttle Spacesuit: Fabric/LCVG Model Validation

A detailed spacesuit computational model is being developed at the Langley Research Center for radiation exposure evaluation studies. The details of the construction of the spacesuit are critical to estimation of exposures and assessing the risk to the astronaut on EVA. Past evaluations of spacesuit shielding properties assumed the basic fabric lay-up (Thermal Micrometeroid Garment, fabric restraints, and pressure envelope) and Liquid Cooling and Ventilation Garment (LCVG) could be homogenized as a single layer overestimating the protective properties over 60 percent of the fabric area. The present spacesuit model represents the inhomogeneous distributions of LCVG materials (mainly the water filled cooling tubes). An experimental test is performed using a 34-MeV proton beam and high- resolution detectors to compare with model-predicted transmission factors. Some suggestions are made on possible improved construction methods to improve the spacesuit's protection properties.

Wilson, J. W.↗