Search NASA⌕ Search

SEARCH · Search NASA

Results for “prototyped verification system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The RF Protection Interlock System Prototype Verification

The Radio Frequency Protection Interlock system plays vital role in the LLRF related/dependent accelerator sections Protection. It’s main role is to collect information from number different sensors and indicators around nearest cavities and cryomodule and provide instant RF signal termination in case of safety thresholds violation. This submission describes newly designed RFPI system tailored to the Proton Improvement Plan II (PIP-II) requirements. The proof of concept prototype of this system has been build. The paper includes also the CMTF environment evaluation tests results and findings as an input to the next full-scope prototype design.

43 PARTICLE ACCELERATORS↗

MO-AB-BRA-07: Prompt Gamma-Ray Spectroscopy for Range Verification of Clinical Proton Beams

Purpose: We developed a pre-clinical prototype system for range verification of proton pencil-beam scanning fields. The system was evaluated using phantom treatment plans delivered with a clinical dose rate. Methods: The absolute range of proton pencil-beams was verified through an optimization procedure, which matches energy- and time-resolved prompt gamma-ray measurements with models, based on cross sections for discrete prompt gamma-ray line excitations. Phantom experiments were performed with a pre-clinical prototype detector, using treatment plans delivered with a clinical pencil-beam scanning system. The detector consisted of an actively shielded lanthanum(III) bromide scintillator. Tungsten was used to collimate the gamma-rays. To support high event rates, the detector readout featured custom amplifiers and an active voltage divider for the photomultiplier. The detector signals were acquired by fast analog-to-digital converters and processed using digital algorithms. The data acquisition was also synchronized with the pencil-beam scanning and dosimetry systems. Results: We successfully acquired prompt gamma-ray spectra during the delivery of proton pencil-beams with a clinical beam current of 2 nA at the exit of the treatment head. The number of events in the primary detector ranged from 1 x 10{sup 6} to 2 x 10{sup 6} per second. In phantom experiments, non-uniform range errors were introduced by placing strips of plastic in the beam path. The magnitudes and positions of these range errors were correctly detected in two-dimensional range maps that were generated from the measurements. With our small scale prototype, a 1.0 mm standard deviation on the absolute range required about 5 x 10{sup 8} protons per delivered pencil-beam. Conclusions: Prompt gamma-ray spectroscopy to verify the absolute range of proton beams was demonstrated under clinical pencil-beam delivery conditions. A 1 mm to 2 mm range verification accuracy for a field delivering 1 Gy, appears feasible with a full scale system. This work was supported by the Federal Share of program income earned on C06-CA059267, Proton Therapy Research and Treatment Center.

60 APPLIED LIFE SCIENCES↗

Verification of Spent Fuel Inside Dry Storage Casks by Cask Top Fast Neutron Mapping (FY2023 Mid-Year Report)

This project is developing a prototype scanner array verification system for detection of missing fuel assemblies in spent-fuel storage casks. The prototype consists of six fast-neutron scintillator detectors mounted to a linear actuator frame that is placed on the top of a spent fuel cask to scan across all fuel assembly positions. The scanner array was assembled and tested at LLNL in FY2022. A field test schedule has been requested at the Idaho National Laboratory (INL) Cask Farm site for FY2023. Note that the Cask Farm contractor determines this scheduling and not INL directly. Further system automation will be designed and implemented with the goal of obtaining a level of system operation that meets IAEA needs. This includes integration of the scanner array and data-acquisition control software into a single interface for operator use. In addition, commercial operators and the IAEA may have special requirements for portability, shipping, lifting, and installation. Prior to the Field Test at INL, the system will be operated at LLNL to exercise lifting procedure and linear actuators, monitor stability of detector energy and pulse-shape discrimination calibration, and test system software integration efforts. Following the Field Test, we will present results and discuss the technology with the IAEA. We will incorporate additional improvements to the system based on lessons learned from the field test and feedback from the IAEA. If successful, the technology can be transferred to the IAEA or other stakeholders for assessment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

FY2024 Mid-Year Report: Verification of Spent Fuel Inside Dry Storage Casks by Cask Top Fast Neutron Mapping

This project is developing a prototype scanner array verification system for detection of missing fuel assemblies in spent-fuel storage casks. The prototype consists of six fast-neutron scintillator detectors mounted to a linear actuator frame that is placed on the top of a spent fuel cask to scan across all fuel assembly positions. The scanner array was assembled and tested at LLNL in prior years. A field test schedule has been requested at the Idaho National Laboratory (INL) Cask Farm site for FY2024. Following the Field Test, we will present results and discuss the technology with the IAEA. The IAEA may have special requirements for portability, shipping, lifting, and installation. We will incorporate additional improvements to the system based on lessons learned from the Field Test and feedback from the IAEA. If successful, the technology can be transferred to the IAEA or other stakeholders for assessment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Characterization of a fiber-coupled Al{sub 2}O{sub 3}:C luminescence dosimetry system for online in vivo dose verification during {sup 192}Ir brachytherapy

A prototype of a new dose-verification system has been developed to facilitate prevention and identification of dose delivery errors in remotely afterloaded brachytherapy. The system allows for automatic online in vivo dosimetry directly in the tumor region using small passive detector probes that fit into applicators such as standard needles or catheters. The system measures the absorbed dose rate (0.1 s time resolution) and total absorbed dose on the basis of radioluminescence (RL) and optically stimulated luminescence (OSL) from aluminum oxide crystals attached to optical fiber cables (1 mm outer diameter). The system was tested in the range from 0 to 4 Gy using a solid-water phantom, a Varian GammaMed Plus {sup 192}Ir PDR afterloader, and dosimetry probes inserted into stainless-steel brachytherapy needles. The calibrated system was found to be linear in the tested dose range. The reproducibility (one standard deviation) for RL and OSL measurements was 1.3%. The measured depth-dose profiles agreed well with the theoretical expectations computed with the EGSNRC Monte Carlo code, suggesting that the energy dependence for the dosimeter probes (relative to water) is less than 6% for source-to-probe distances in the range of 2-50 mm. Under certain conditions, the RL signal could be greatly disturbed by the so-called stem signal (i.e., unwanted light generated in the fiber cable upon irradiation). The OSL signal is not subject to this source of error. The tested system appears to be adequate for in vivo brachytherapy dosimetry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Two-Layer Predictive Controller for V2G and G2V Services Using on Wireless Power Transfer Technology

This paper presents a comprehensive solution that allows electric vehicles (EV) to autonomously charge and discharge their batteries wirelessly during long term parking and/or the transient stops. A two-layer power-flow controller for bidirectional wireless power transfer system (BWPTS) in EVs applications is proposed. The proposed controller can manage the bidirectional power-flow between EV and surrounding infrastructures such as power grid, home microgrid, building micro-grid, road or another vehicle. It consists of two levels of control; the first is responsible for communicating with the surrounding infrastructures and gathering information from driver, charging station, power grid and battery management system and then, based on these information, it estimates the EV's psychological price as a function of its battery's state-of-charge (SOC) and compares it with the energy price to decide whether to charge, discharge or abstain, and how much the charging or discharging rate. The second layer receives the reference signal from the first one and generates the control parameters for two synchronized resonant converters (one is on the vehicle side and the other is on the grid side) to provide the requited power-flow. The proposed controller is adaptively estimating the system parameters to consider the misalignment conditions effects on the system performance. The parameter estimation is achieved using only one voltage sensor. The second layer control is designed based on a new analytical modeling for the power flow in the system. For verification purposes, a prototype for BWPTS was built and driven by the proposed controller, which was implemented using a field-programmable gate array (FPGA) integrated circuit. The proposed controller provides very fast and stable response during both the transient and steady state operation in comparison with the conventional PI controller.

33 ADVANCED PROPULSION SYSTEMS↗

Optimization of Kaplan Hydroturbine at Very Low Head With Rim-Driven Generator

The objective of the paper is to study the design and optimization of Kaplan hydroturbines for a very low head (less than 3 m), with a particular emphasis on the use of rim-drive electrical generators. The work is based on an experimental setup and computational fluid dynamics (CFD) analysis of various design parameters for maximum output power and efficiency. Two designs are presented in this paper. One is a 90-cm (35-in.) diameter vertical-oriented Kaplan hydroturbine system as an intended product capable of generating over 50 kW. The other is a smaller, 7.6-cm (3-in.) diameter horizontal-oriented system for prototyping and laboratory verification. Both are analyzed through CFD based on large eddy simulation (LES) of transient turbulence. Specific design for the runner and the stator, intake tube shape, as well as guide vanes upstream of the turbine was studied to get the most from the available head. The intent is to use 3D-printing manufacturing techniques, which may offer original design opportunities as well as the possibility of turbine and water conduit design customization as a function of the head and flow available from a specific site. Based on the CFD analysis, the 7.6-cm diameter system achieved the highest power output and the maximum efficiency at the rotational speed range of 1500–2000 rpm, while for the experimental testing, the optimum rotational speed range was 1000–1500 rpm. Because of the mismatch between CFD and experimental results, the CFD results were correlated due to the presence of air and friction; moreover, error and uncertainty analysis were presented for both methods. For the 90-cm case, the optimum performance was found at a rotational speed around 350 rpm according to the CFD results. Finally, investigating the shape of the intake tube of the hydroturbine setup can significantly increase the power output and the efficiency of the system.

Energy & Fuels↗

SU-D-213-05: Design, Evaluation and First Applications of a Off-Site State-Of-The-Art 3D Dosimetry System

Purpose: To design, construct and commission a prototype in-house three dimensional (3D) dose verification system for stereotatic body radiotherapy (SBRT) verification at an off-site partner institution. To investigate the potential of this system to achieve sufficient performance (1mm resolution, 3% noise, within 3% of true dose reading) for SBRT verification. Methods: The system was designed utilizing a parallel ray geometry instigated by precision telecentric lenses and an LED 630nm light source. Using a radiochromic dosimeter, a 3D dosimetric comparison with our gold-standard system and treatment planning software (Eclipse) was done for a four-field box treatment, under gamma passing criteria of 3%/3mm/10% dose threshold. Post off-site installation, deviations in the system’s dose readout performance was assessed by rescanning the four-field box irradiated dosimeter and using line-profiles to compare on-site and off-site mean and noise levels in four distinct dose regions. As a final step, an end-to-end test of the system was completed at the off-site location, including CT-simulation, irradiation of the dosimeter and a 3D dosimetric comparison of the planned (Pinnacle{sup 3}) to delivered dose for a spinal SBRT treatment(12 Gy per fraction). Results: The noise level in the high and medium dose regions of the four field box treatment was relatively 5% pre and post installation. This reflects the reduction in positional uncertainty through the new design. This At 1mm dose voxels, the gamma pass rates(3%,3mm) for our in-house gold standard system and the off-site system were comparable at 95.8% and 93.2% respectively. Conclusion: This work will describe the end-to-end process and results of designing, installing, and commissioning a state-of-the-art 3D dosimetry system created for verification of advanced radiation treatments including spinal radiosurgery.

60 APPLIED LIFE SCIENCES↗

Multi-Rigor Agile Verification and Rapid Prototyping for Formally Verified Software

We propose a novel approach to developing formally verified systems through Multi-rigor Agile Verification. Multi-rigor Agile Verification is rooted in the hypothesis of Rigor Independence, that a system’s specification and verification architecture depend primarily on the system requirements to be verified, and they depend very little on the rigor level of the methods used to verify those requirements. Due to its iterative nature, Multi-rigor Agile Verification promises to mitigate many of the high upfront design costs experienced by formally verified systems and to deliver a better-architected, and thus better-trusted, system in the end. We then discuss the tooling needed to perform Multi-rigor Agile Verification and go in depth to build one of those tools, which directly generates executable prototype code from declarative formal specifications using the Maude rewrite-logic framework.

97 MATHEMATICS AND COMPUTING↗

A Coil Detection System for Dynamic Wireless Charging of Electric Vehicle

Application of wireless power transfer while EV is in motion can significantly reduce the battery storage capacity. A major challenge in implementation of dynamic wireless power transfer (DWPT) is automatic detection of EV to avoid loss in efficiency and alleviate any safety concerns. This paper proposes a novel coil detection method for segmented DWPT. Detection of the EV ahead of its arrival will initiate energizing of the transmitter buried inside the road to enable just-in-time transfer of power. At low speeds, communication can be a reliable method to power up the transmitter coil. However, at high speeds on highways, communication latency time for the detection of an EV is long and hence impractical. This paper proposes a low cost and low power EV detection system based on a novel orthogonal coil arrangement to detect EVs traveling at high speeds. Here, the proposed detection system was tested on a laboratory scale prototype for verification purpose. For high speed verification, simulation in PLECS was conducted to test the functionality of the proposed system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

New Prototype Safeguards Technology Offers Improved Confidence and Automation for Uranium Enrichment Facilities

An important requirement for the international safeguards community is the ability to determine the enrichment level of uranium in gas centrifuge enrichment plants and nuclear fuel fabrication facilities. This is essential to ensure that countries with nuclear nonproliferation commitments, such as States Party to the Nuclear Nonproliferation Treaty, are adhering to their obligations. However, current technologies to verify the uranium enrichment level in gas centrifuge enrichment plants or nuclear fuel fabrication facilities are technically challenging and resource-intensive. NNSA’s Office of Nonproliferation and International Security (NIS) supports the development, testing, and evaluation of future systems that will strengthen and sustain U.S. safeguards and security capabilities—in this case, by automating the monitoring of uranium enrichment in the entire inventory of a fuel fabrication facility. One such system is HEVA—hybrid enrichment verification array. This prototype was developed to provide an automated, nondestructive assay verification technology for uranium hexafluoride (UF6) cylinders at enrichment plants.

automated, nondestructive assay verification techn↗

Potential of discrete Gaussian edge feathering method for improving abutment dosimetry in eMLC-delivered segmented-field electron conformal therapy

Purpose: The purpose of this work was to investigate the potential of discrete Gaussian edge feathering of the higher energy electron fields for improving abutment dosimetry in the planning volume when using an electron multileaf collimator (eMLC) to deliver segmented-field electron conformal therapy (ECT). Methods: A discrete (five-step) Gaussian edge spread function was used to match dose penumbras of differing beam energies (6-20 MeV) at a specified depth in a water phantom. Software was developed to define the leaf eMLC positions of an eMLC that most closely fit each electron field shape. The effect of 1D edge feathering of the higher energy field on dose homogeneity was computed and measured for segmented-field ECT treatment plans for three 2D PTVs in a water phantom, i.e., depth from the water surface to the distal PTV surface varied as a function of the x-axis (parallel to leaf motion) and remained constant along the y-axis (perpendicular to leaf motion). Additionally, the effect of 2D edge feathering was computed and measured for one radially symmetric, 3D PTV in a water phantom, i.e., depth from the water surface to the distal PTV surface varied as a function of both axes. For the 3D PTV, the feathering scheme was evaluated for 0.1-1.0-cm leaf widths. Dose calculations were performed using the pencil beam dose algorithm in the Pinnacle{sup 3} treatment planning system. Dose verification measurements were made using a prototype eMLC (1-cm leaf width). Results: 1D discrete Gaussian edge feathering reduced the standard deviation of dose in the 2D PTVs by 34, 34, and 39%. In the 3D PTV, the broad leaf width (1 cm) of the eMLC hindered the 2D application of the feathering solution to the 3D PTV, and the standard deviation of dose increased by 10%. However, 2D discrete Gaussian edge feathering with simulated eMLC leaf widths of 0.1-0.5 cm reduced the standard deviation of dose in the 3D PTV by 33-28%, respectively. Conclusions: A five-step discrete Gaussian edge spread function applied in 2D improves the abutment dosimetry but requires an eMLC leaf resolution better than 1 cm.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-J-46: Development of a Compton Camera Prototype for Online Range Verification of Laser-Accelerated Proton Beams

Purpose: Development of a photon detection system designed for online range verification of laser-accelerated proton beams via prompt-gamma imaging of nuclear reactions. Methods: We develop a Compton camera for the position-sensitive detection of prompt photons emitted from nuclear reactions between the proton beam and biological samples. The detector is designed to be capable to reconstruct the photon source origin not only from the Compton scattering kinematics of the primary photon, but also to allow for tracking of the Compton-scattered electrons. Results: Simulation studies resulted in the design of the Compton camera based on a LaBr{sub 3}(Ce) scintillation crystal acting as absorber, preceded by a stacked array of 6 double-sided silicon strip detectors as scatterers. From the design simulations, an angular resolution of ≤ 2° and an image reconstruction efficiency of 10{sup −3} −10{sup −5} (at 2–6 MeV) can be expected. The LaBr{sub 3} crystal has been characterized with calibration sources, resulting in a time resolution of 273 ps (FWHM) and an energy resolution of about 3.8% (FWHM). Using a collimated (1 mm diameter) {sup 137}Cs calibration source, the light distribution was measured for each of 64 pixels (6×6 mm{sup 2}). Data were also taken with 0.5 mm collimation and 0.5 mm step size to generate a reference library of light distributions that allows for reconstructing the interaction position of the initial photon using a k-nearest neighbor (k-NN) algorithm developed by the Delft group. Conclusion: The Compton-camera approach for prompt-gamma detection offers promising perspectives for ion beam range verification. A Compton camera prototype is presently being developed and characterized in Garching. Furthermore, an arrangement of, e.g., 4 camera modules could even be used in a ‘gamma-PET’ mode to detect delayed annihilation radiation from positron emitters in the irradiation interrupts (with improved performance in the presence of an additional third (prompt) photon (as in 10C and 14O). This work was supported by the DFG Cluster of Excellence MAP (Munich-Centre for Advanced Photonics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laboratory-Scale Microgrid System for Control of Power Distribution in Local Energy Networks - Part II: Implementation and Case Study

In this chapter, we provide the detailed implementation of the proposed microgrid framework in part I. As a case study, a droop-based load sharing algorithm with the capability of controlling the active and reactive power have been implemented. Several load sharing scenarios have been studied to verify the capability of the suggested prototype in performance evaluation and verification of different control strategies in microgrid systems. The performed experiments confirm the capacity of the proposed structure in microgrid research and development (R&D), as well as education.

design↗

TU-FG-BRB-05: A 3 Dimensional Prompt Gamma Imaging System for Range Verification in Proton Radiotherapy

Purpose: To report on the initial developments of a clinical 3-dimensional (3D) prompt gamma (PG) imaging system for proton radiotherapy range verification. Methods: The new imaging system under development consists of a prototype Compton camera to measure PG emission during proton beam irradiation and software to reconstruct, display, and analyze 3D images of the PG emission. For initial test of the system, PGs were measured with a prototype CC during a 200 cGy dose delivery with clinical proton pencil beams (ranging from 100 MeV – 200 MeV) to a water phantom. Measurements were also carried out with the CC placed 15 cm from the phantom for a full range 150 MeV pencil beam and with its range shifted by 2 mm. Reconstructed images of the PG emission were displayed by the clinical PG imaging software and compared to the dose distributions of the proton beams calculated by a commercial treatment planning system. Results: Measurements made with the new PG imaging system showed that a 3D image could be reconstructed from PGs measured during the delivery of 200 cGy of dose, and that shifts in the Bragg peak range of as little as 2 mm could be detected. Conclusion: Initial tests of a new PG imaging system show its potential to provide 3D imaging and range verification for proton radiotherapy. Based on these results, we have begun work to improve the system with the goal that images can be produced from delivery of as little as 20 cGy so that the system could be used for in-vivo proton beam range verification on a daily basis.

60 APPLIED LIFE SCIENCES↗

In Situ Data Infrastructure for Scientific Unit Testing Platform

Testing is a significant software development process for the management of software systems and scientific code. However, as the complexity of scientific codes increases, extra checks are needed to monitor impacts to dependent models and to verify system constraints. The software complexity also impedes the efforts of module developers and software engineers to rapidly develop and extend their code. Recently, we have developed an automatic methodology and prototype platform to facilitate scientific verification of individual functions within complex scientific codes. With this system, the scientific module builders are able to track variables conveniently in one module or track variables’ changes among different modules. In this paper, we present a procedure for automatic unit testing generation. For the interest of a general audience of this conference, we are emphasizing the technical details of integrating the In Situ data infrastructure into our platform. At the end of this paper, we have included an implementation of unit testing for the ACME Land Model (ALM) to demonstrate the usefulness and correctness of the platform. We have also used single- and multipoint checks to demonstrate the efficient variable tracking capability of this platform.

97 MATHEMATICS AND COMPUTING↗

A new method for wideband characterization of resonator-based sensing platforms

A new approach to the electronic instrumentation for extracting data from resonator-based sensing devices (e.g., microelectromechanical, piezoelectric, electrochemical, and acoustic) is suggested and demonstrated here. Traditionally, oscillator-based circuitry is employed to monitor shift in the resonance frequency of the resonator. These circuits give a single point measurement at the frequency where the oscillation criterion is met. However, the resonator response itself is broadband and contains much more information than a single point measurement. Here, we present a method for the broadband characterization of a resonator using white noise as an excitation signal. The resonator is used in a two-port filter configuration, and the resonator output is subjected to frequency spectrum analysis. The result is a wideband spectral map analogous to the magnitude of the S21 parameters of a conventional filter. Compared to other sources for broadband excitation (e.g., frequency chirp, multisine, or narrow time domain pulse), the white noise source requires no design of the input signal and is readily available for very wide bandwidths (1 MHz-3 GHz). Moreover, it offers simplicity in circuit design as it does not require precise impedance matching; whereas such requirements are very strict for oscillator-based circuit systems, and can be difficult to fulfill. This results in a measurement system that does not require calibration, which is a significant advantage over oscillator circuits. Simulation results are first presented for verification of the proposed system, followed by measurement results with a prototype implementation. A 434 MHz surface acoustic wave (SAW) resonator and a 5 MHz quartz crystal microbalance (QCM) are measured using the proposed method, and the results are compared to measurements taken by a conventional bench-top network analyzer. Maximum relative differences in the measured resonance frequencies of the SAW and QCM resonators are 0.0004% and 0.002%, respectively. The ability to track a changing sensor response is demonstrated by inducing temperature variations and measuring resonance frequency simultaneously using the proposed technique in parallel with a network analyzer. The relative difference between the two measurements is about 5.53 ppm, highlighting the impressive accuracy of the proposed system. Using commercially available digital signal processors (DSPs), we believe that this technique can be implemented as a system-on-a-chip solution resulting in a very low cost, easy to use, portable, and customizable sensing system. In addition, given the simplicity of the signal and circuit design, and its immunity to other common interface concerns (injection locking, oscillator interference, and drift, etc.), this method is better suited to accommodating array-based systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NEAMS Experimental Support for Code Validation, INL FY2009

The goal is for all modeling and simulation tools to be demonstrated accurate and reliable through a formal Verification and Validation (V&V) process, especially where such tools are to be used to establish safety margins and support regulatory compliance, or to design a system in a manner that reduces the role of expensive mockups and prototypes. Whereas the Verification part of the process does not rely on experiment, the Validation part, on the contrary, necessitates as many relevant and precise experimental data as possible to make sure the models reproduce reality as closely as possible. Hence, this report presents a limited selection of experimental data that could be used to validate the codes devoted mainly to Fast Neutron Reactor calculations in the US. Emphasis has been put on existing data for thermal-hydraulics, fuel and reactor physics. The principles of a new “smart” experiment that could be used to improve our knowledge of neutron cross-sections are presented as well. In short, it consists in irradiating a few milligrams of actinides and analyzing the results with Accelerator Mass Spectroscopy to infer the neutron cross-sections. Finally, the wealth of experimental data relevant to Fast Neutron Reactors in the US should not be taken for granted and efforts should be put on saving these 30-40 years old data and on making sure they are validation-worthy, i.e. that the experimental conditions and uncertainties are well documented.

97 MATHEMATICS AND COMPUTING↗