Search NASA⌕ Search

SEARCH · Search NASA

Results for “pseudo measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Linear Distribution System State Estimation Using Synchrophasor Data and Pseudo-Measurement

State estimation is often a challenging task in distribution systems due to deploying a limited number of measurement devices. Moreover, the integration of precise distributionlevel phasor measurement unites, a.k.a micro-PMUs, along with inaccurate pseudo-measurements in state estimation introduces another challenge. These issues might decrease the efficiency of traditional standard weighted least squares (WLS) for distribution system state estimation. This paper proposes a novel linear distribution system state estimation with taken different types of measurements, including micro-PMU measurements and line current measurements, into account. To involve pseudomeasurements into the linear state estimation, a linearization method based on the Taylor’s approximation is adopted to reformulate pseudo-measurement functions in a linear form. The results obtained via numerical simulations show that the proposed linear state estimation method performs similarly to the standard nonlinear WLS estimator. In addition, the sensitivity analyses results show that our method has a better performance compared to WLS once a limited number of highly precise micro-PMUs are accompanied with inaccurate pseudo-measurements in state estimation.

State estimation Distribution system Micro-PMU Lin↗

A Game-Theoretic Data-Driven Approach for Pseudo-Measurement Generation in Distribution System State Estimation

In this paper, we present an efficient computational framework with the purpose of generating weighted pseudo-measurements to improve the quality of distribution system state estimation (DSSE) and provide observability with advanced metering infrastructure (AMI) against unobservable customers and missing data. The proposed technique is based on a game-theoretic expansion of relevance vector machines (RVMs). This platform is able to estimate the nodal power consumption and quantify its uncertainty while reducing the prohibitive computational burden of model training for large AMI datasets. To achieve this objective, the large training set is decomposed and distributed among multiple parallel learning entities. The resulting estimations from the parallel RVMs are then combined using a game-theoretic model based on the idea of repeated games with vector payoff. It is observed that through this approach and by exploiting the seasonal changes in customers’ behavior the accuracy of pseudo-measurements can be considerably improved, while introducing robustness against bad training data samples. The proposed pseudo-measurement generation model is integrated into a DSSE using a closed-loop information system, which takes advantage of a branch current state estimator (BCSE) to further improve the performance of the designed machine learning framework. This method has been tested on a practical distribution feeder model with smart meter data for verification.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Probabilistic Data-Driven Method for Photovoltaic Pseudo-Measurement Generation in Distribution Systems

This paper presents a probabilistic data-driven method to model the uncertainty of distributed photovoltaic (PV) generation to enhance the observability of distribution grids with a high penetration of renewable resources. The proposed method employs a kernel density estimation (KDE) technique to develop the conditional probability density function (PDF) of PV outputs given the time of the day, using the measurement data from observed PV systems. Then time series of output power of unmeasured PV generators, located at the same grid, are generated according to the corresponding PDF and used as pseudo-measurements in distribution system state estimation (DSSE). The proposed model has been tested and verified using real PV data and utility networks.

Yuan, Yuxuan↗

Robust Medium-Voltage Distribution System State Estimation using Multi-Source Data

Due to the lack of sufficient online measurements for distribution system observability, pseudo-measurements from short-term load or distributed renewable energy resources (DERs) forecasting are used. However, the accuracy of them is low and thus significantly limits the performance of distribution system state estimation (DSSE). In this paper, a robust DSSE that integrates multi-source measurement data is proposed. Specifically, the historical low-voltage (LV) side smart meters are used to forecast load and DERs injections via the support vector machine (SVM) with optimally tuned parameters. By contrast, the online smart meters at LV side are utilized to derive equivalent power injections at the MV/LV transformers, yielding more accurate pseudo-measurements compared to the forecasted injections. Furthermore, to deal with bad data caused by communication loss, instrumental errors and cyber attacks, robust DSSE that relies on generalized maximum-likelihood (GM)-estimation criterion is developed. The projection statistics are developed to adjust the weights of each measurement, leading to better balance between pseudo- and real-time measurements. Numerical results conducted on modified IEEE 33-bus system with DG integration demonstrate the effectiveness and robustness of the proposed method.

distribution system state estimation↗

Distribution System State Estimation With High Penetration of Demand Response Enabled Loads

Demand-side operations incentivize utility customers to take part in various grid services. A demand response enabled load (DREL) is a flexible grid asset that schedules electricity consumption in response to a time-of-use (TOU) energy price. Consequently, its energy profile differs from that of a conventional load that is insensitive to price. This difference may cause new challenges for distribution system state estimation (DSSE). It is well known that DSSE often needs to use pseudo-measurements based on historic load profiles to increase system observability. However, historic profiles of conventional loads are not representative of DREL behaviors. Additionally, the inaccuracy impacts DSSE results and other DSSE-dependent operations. In this paper, we propose an online pseudo-measurement generation approach for DSSE with DRELs. We formulate an optimization model to represent DRELs self-adjusting actions. Sampling-based stochastic optimization techniques are proposed to account for uncertainties in DRELs. A set of representative DREL behavior data corresponding to the samples are used to characterize DREL pseudo-measurements. Case studies with modified IEEE 123-bus test system verify the validity of the proposed work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A low cost approach to simultaneous orbit, attitude, and rate estimation using an extended Kalman filter

An innovative approach to autonomous attitude and trajectory estimation is available using only magnetic field data and rate data. The estimation is performed simultaneously using an Extended Kalman Filter (EKF), a well known algorithm used extensively in onboard applications. The magnetic field is measured on a satellite by a magnetometer, an inexpensive and reliable sensor flown on virtually all satellites in low earth orbit. Rate data is provided by a gyro, which can be costly. This system has been developed and successfully tested in a post-processing mode using magnetometer and gyro data from 4 satellites supported by the Flight Dynamics Division at Goddard. In order for this system to be truly low cost, an alternative source for rate data must be utilized. An independent system which estimates spacecraft rate has been successfully developed and tested using only magnetometer data or a combination of magnetometer data and sun sensor data, which is less costly than a gyro. This system also uses an EKF. Merging the two systems will provide an extremely low cost, autonomous approach to attitude and trajectory estimation. In this work we provide the theoretical background of the combined system. The measurement matrix is developed by combining the measurement matrix of the orbit and attitude estimation EKF with the measurement matrix of the rate estimation EKF, which is composed of a pseudo-measurement which makes the effective measurement a function of the angular velocity. Associated with this is the development of the noise covariance matrix associated with the original measurement combined with the new pseudo-measurement. In addition, the combination of the dynamics from the two systems is presented along with preliminary test results.

Deutschmann, Julie↗

A Low Cost Approach to Simultaneous Orbit, Attitude, and Rate Estimation Using an Extended Kalman Filter

An innovative approach to autonomous attitude and trajectory estimation is available using only magnetic field data and rate data. The estimation is performed simultaneously using an Extended Kalman Filter, a well known algorithm used extensively in onboard applications. The magnetic field is measured on a satellite by a magnetometer, an inexpensive and reliable sensor flown on virtually all satellites in low earth orbit. Rate data is provided by a gyro, which can be costly. This system has been developed and successfully tested in a post-processing mode using magnetometer and gyro data from 4 satellites supported by the Flight Dynamics Division at Goddard. In order for this system to be truly low cost, an alternative source for rate data must be utilized. An independent system which estimate spacecraft rate has been successfully developed and tested using only magnetometer data or a combination of magnetometer data and sun sensor data, which is less costly than a gyro. This system also uses an Extended Kalman Filter. Merging the two systems will provide an extremely low cost, autonomous approach to attitude and trajectory estimation. In this work we provide the theoretical background of the combined system. The measurement matrix is developed by combining the measurement matrix of the orbit and attitude estimation EKF with the measurement matrix of the rate estimation EKF, which is composed of a pseudo-measurement which makes the effective measurement a function of the angular velocity. Associated with this is the development of the noise covariance matrix associated with the original measurement combined with the new pseudo-measurement. In addition, the combination of the dynamics from the two systems is presented along with preliminary test results.

Deutschmann, Julie↗

LIFETIME MEASUREMENT WITH PSEUDO MOVEABLE SEPTUM IN NSLS X-RAY RING

The National Synchrotron Light Source II (NSLS-II) is a state of the art 3 GeV third generation light source currently under construction at Brookhaven National Laboratory and starts to commission in 2014. The beam injection works with two septa and four fast kicker magnets in an injection section. To improve the injection stability and reproducibility, we plan to implement a slow local bump on top of the fast bump so that the fast kicker strength is reduced. This bump works as a pseudo movable septum. We can also use this 'movable' septum to measure the storage ring beam partial lifetime resulting from the septum edge and possibly increasing the lifetime by moving the stored beam orbit away from the edge. We demonstrate the feasibility of this idea, by implementing DC bump in NSLS X-ray ring. We report the results of beam lifetime measurements as a function of the amplitude of this bumped orbit relative to the septum and the idea of a slow bump that could reduce the fast bump magnet strengths.

43 PARTICLE ACCELERATORS↗

Recursive filter initialization.

Description of an initialization technique which partially accounts for the interrelation between the true-state vector errors when recursive filtering is applied in space navigation systems. The technique reduces the undesirable transient effects of the first few measurements and inhibits filter divergence when the interval between measurements is inordinately large. The key feature of this technique is the inclusion of the effect of a number of pseudo-measurements of certain orbital parameters into the initial covariance matrix. The pseudo-measurement technique has been shown to be useful when reinitialization of the error covariance matrix is required to prevent filter divergence.

Battin, R. H.↗

Multi-Fidelity Gaussian Process for Distribution System Voltage Probabilistic Estimation with PVs

The increasing penetration of behind-the-meter PVs causes challenges to maintain voltage security due to the lack of distribution system visibility. This paper proposes a nonlinear autoregressive Gaussian process (NARGP) approach to fuse limited number of SCADA/AMI data together with historical pseudo measurements for distribution node voltage probabilistic estimation. The high-fidelity SCADA data are fused with the low-fidelity AMI and pseudo measurements by the autoregressive algorithm embedded in the Gaussian process. This allows us to use multi-fidelity data to achieve entire distribution system voltage visibility. Numerical results carried out on the IEEE 123node system demonstrate that the NARGP method is able to obtain high accuracy in estimating bus voltage and quantifying estimation uncertainties as compared to other approaches.

distribution system estimation↗

A Machine Learning-Based Method to Estimate Transformer Primary-Side Voltages with Limited Customer-Side AMI Measurements

Distribution control applications such as volt/var optimization, network reconfiguration, and distribution automation require accurate knowledge of the distribution system state. The lack of sufficient sensors on the primary side of distribution networks often limits the accuracy of the control decisions by these applications. The deployment of advanced metering infrastructure (AMI) provides utilities an opportunity to translate the AMI data on the secondary onto the primary so that it can be used as pseudo-measurements to augment the limited existing measurements on the primary. This paper develops an approach for estimating service transformer primary-side voltages by using limited secondary-side AMI measurements. The estimated primary-side voltages can be used by utilities as pseudo-measurements for distribution control applications. The detailed secondary model topology, which is an essential input data for many existing algorithms, is not required for the proposed method. The performance of the proposed method is validated by using AMI measurements from the field and an actual distribution feeder model of San Diego Gas & Electric Company.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Machine Learning-Based Method to Estimate Transformer Primary-Side Voltages with Limited Customer-Side AMI Measurements: Preprint

Distribution control applications such as volt/var optimization, network reconfiguration, and distribution automation require accurate knowledge of the distribution system state. The lack of sufficient sensors on the primary side of distribution networks often limits the accuracy of the control decisions by these applications. The deployment of advanced metering infrastructure (AMI) provides utilities an opportunity to translate the AMI data on the secondary onto the primary so that it can be used as pseudo-measurements to augment the limited existing measurements on the primary. This paper develops an approach for estimating service transformer primary-side voltages by using limited secondary-side AMI measurements. The estimated primary-side voltages can be used by utilities as pseudo-measurements for distribution control applications. The detailed secondary model topology, which is an essential input data for many existing algorithms, is not required for the proposed method. The performance of the proposed method is validated by using AMI measurements from the field and an actual distribution feeder model of San Diego Gas & Electric Company.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Network design for quantifying urban CO<sub>2</sub> emissions: assessing trade-offs between precision and network density

The majority of anthropogenic CO 2 emissions are attributable to urban areas. While the emissions from urban electricity generation often occur in locations remote from consumption, many of the other emissions occur within the city limits. Evaluating the effectiveness of strategies for controlling these emissions depends on our ability to observe urban CO 2 emissions and attribute them to specific activities. Cost-effective strategies for doing so have yet to be described. Here we characterize the ability of a prototype measurement network, modeled after the Berkeley Atmospheric CO 2 Observation Network (BEACO 2 N) in California's Bay Area, in combination with an inverse model based on the coupled Weather Research and Forecasting/Stochastic Time-Inverted Lagrangian Transport (WRF-STILT) to improve our understanding of urban emissions. The pseudo-measurement network includes 34 sites at roughly 2 km spacing covering an area of roughly 400 km 2 . The model uses an hourly 1 × 1 km 2 emission inventory and 1 × 1 km 2 meteorological calculations. We perform an ensemble of Bayesian atmospheric inversions to sample the combined effects of uncertainties of the pseudo-measurements and the model. We vary the estimates of the combined uncertainty of the pseudo-observations and model over a range of 20 to 0.005 ppm and vary the number of sites from 1 to 34. We use these inversions to develop statistical models that estimate the efficacy of the combined model–observing system in reducing uncertainty in CO 2 emissions. We examine uncertainty in estimated CO 2 fluxes on the urban scale, as well as for sources embedded within the city such as a line source (e.g., a highway) or a point source (e.g., emissions from the stacks of small industrial facilities). Using our inversion framework, we find that a dense network with moderate precision is the preferred setup for estimating area, line, and point sources from a combined uncertainty and cost perspective. The dense network considered here (modeled after the BEACO 2 N network with an assumed mismatch error of 1 ppm at an hourly temporal resolution) could estimate weekly CO 2 emissions from an urban region with less than 5 % error, given our characterization of the combined observation and model uncertainty.

54 ENVIRONMENTAL SCIENCES↗

A Machine Learning-Based Method to Estimate Transformer Primary-Side Voltages with Limited Customer-Side AMI Measurements

Distribution control applications such as volt/var optimization, network reconfiguration, and distribution automation require accurate knowledge of the distribution system state. The lack of sufficient sensors on the primary side of distribution networks often limits the accuracy of the control decisions by these applications. The deployment of advanced metering infrastructure (AMI) provides utilities an opportunity to translate the AMI data on the secondary onto the primary so that it can be used as pseudo-measurements to augment the limited existing measurements on the primary. This paper develops a machine learning based approach for estimating service transformer primary-side voltages by using limited secondary-side AMI measurement. The machine learning model is developed by using random forest algorithm. The estimated primary-side voltages can be used by utilities as pseudo-measurements for distribution control applications. The detailed secondary model topology, which is an essential input data for many existing algorithms, is not required for the proposed method. The performance of the proposed method is validated by using AMI measurements from the field and an actual distribution feeder model of San Diego Gas & Electric Company.

advanced metering infrastructure↗

Spin observable measurements in pseudo scalar-meson polarized photo-production using polarized deutrons in solid HD

Recent Lattice QCD calculations have supported the long standing quark model expectation of many more excited states of the nucleon than have been experimentally observed. These missing states are expected to be broad and overlapping and require detailed partial wave analyses (PWA) to disentangle. Measurements of many polarization observables are required to constrain PWA. Furthermore, for evaluation of isoscalar and isovector contributions to photocouplings of 1/2-isospin resonances, photocouplings both off protons and neutrons are needed. To address the latter, the g14/E06-101 experiment at Jlab completed data taking in 2012 using the CLAS with circularly and linearly polarized photons incident on longitudinally polarized neutrons in solid deuterium-hydride (HD) frozen-spin targets. Analysis has been on-going for the data with linearly as well as circularly polarized photon beams. Corrections have been performed for energy loss of charged particles passing through materials on the cryogenic target. Preliminary analyses for double-spin asymmetries on deutron, such as a reaction ? + d ? ?? + p + X aiming to the one on neutron; ? + n(p) ? ?? + p (p) will be discussed.

Kageya, Tsuneo↗

Physics-Informed Deep Neural Network Method for Limited Observability State Estimation

The precise knowledge regarding the state of the power grid is important in order to ensure optimal and reliable grid operation. Specifically, knowing the state of the distribution grid becomes increasingly important as more renewable energy sources are connected directly into the distribution network, increasing the fluctuations of the injected power. In this paper, we consider the case when the distribution grid becomes partially observable, due to for example cyber attacks, and the state estimation problem is under-determined. We present a new methodology that leverages a deep neural network (DNN) to estimate the grid state. The standard DNN training method is modified to explicitly incorporate the physical information of the grid topology and line/shunt admittance. We show that our method leads to a superior accuracy of the estimation when compared to the case when no physical information is provided. Finally, we compare the performance of our method to the standard state estimation approach, which is based on the weighted least squares with pseudo-measurements, and show that our method performs significantly better with respect to the estimation accuracy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Real-Time Distribution System State Estimation with Asynchronous Measurements

We report state estimation is a fundamental task in power systems. Although distribution systems are increasingly equipped with sensing devices and smart meters, measurements are typically reported at different rates and asynchronously; these aspects pose severe strains on workhorse state estimation algorithms, which are designed to process batches of data collected in a synchronous manner from all the measurement units. In this paper, we develop a novel state estimation algorithm to continuously update the estimate of the state based on measurements received in an asynchronous manner from measurement units. The synthesis of the algorithm hinges on a proximal-point type method, implemented in an online fashion, and capable of processing measurements received sequentially from sensors. A performance analysis is presented by providing bounds on the estimation error in terms of the mean and variance that hold at each iteration and asymptotically. The scheme is also compared with a more traditional Weighted Least Squares estimator that compensates for the lack of measurement data by using, as pseudo measurements, the measurement retrieved during a certain time window. Numerical simulations on the IEEE 37-bus feeder corroborate the analytical findings.

24 POWER TRANSMISSION AND DISTRIBUTION↗