Evaluation of surface energy and radiation balance systems on the Konza Prairie

Four Surface Energy and Radiation Balance Systems (SERBS) were installed and operated for two weeks in Kansas during July of 1986. Surface energy and radiation balances were investigated on six sites on the Konza Prairie about 3 km south of Manhattan, Kansas. Measurements were made to allow the computation of these radiation components: total solar and diffuse radiation, reflected solar radiation, net radiation, and longwave radiation upward and downward. Measurements were made to allow the computation of the sensible and latent heat fluxes by the Bowen ratio method using differential psychrometers on automatic exchange mechanisms. The report includes a description of the experimental sites, data acquisition systems and sensors, data acquisitions system operating instructions, and software used for data acquisition and analysis. In addition, data listings and plots of the energy balance components for all days and systems are given.

Fritschen, Leo J.↗

Relationship between wind, waves and radar backscatter

The aim of the research was to investigate the relationship between wind, waves, and radar backscatter from water surface. To this end, three field experiments with periods of 2 to 4 weeks were carried out during summer months in 1988, 1989 and 1990. For these periods, the University of Washington group provided (1) environmental parameters such as wind speed, wind stress, and atmospheric stratification through measurements of surface fluxes (of momentum, sensible heat and latent heat) and of air and water temperatures; and (2) wave height spectra including both the dominant waves and the short gravity-capillary waves. Surface flux measurements were performed by using our well tested instruments: a K-Gill twin propeller-vane anemometer and a fast response thermocouple psychrometer. Wave heights were measured by a resistance wire wave gauge. The University of Kansas group was responsible for the operation of the microwave radars.

Katsaros, Kristina B.↗

Modeling of interactions between biosphere and atmosphere on the global scale

Simulations of weather and climate with general circulation models show that the circulation and rainfall are sensitive to the transfers of radiation, sensible heat, water vapor, and momentum across the atmosphere land surface interface. Because, in nature, these transfers depend in large measure on the morphological and physiological characteristics of the surface vegetation, an interactive biosphere is needed for GCM's. The simple model of the biosphere (SiB) that the authors have constructed is based on the recognized difference between ground cover vegetation (grasses and other herbaceous plants) and canopy vegetation (trees and shrubs), where the latter act like elevated blocks of porous material which efficiently extract momentum from the air that flows through them; by a large number of multiple reflections enhance the absorption of the incident solar radiation; when the canopy is wet, act like well ventilated psychrometers which extract sensible heat from the air and produce a negative Bowen ratio; and, in all of these ways, behave differently from ground cover vegetation. The complete set of governing equations of SiB, whereby the various allowable combinations of trees, ground covers, and bare ground, in interaction with the atmosphere, determine all of the vegetation dependent transfers at the land surface, have been presented and described.

Baer, Ferdinand↗

Animal biocalorimeter and waste management system

A biocalorimeter and waste management system is provided for making metabolic heat release measurements of animals or humans in a calorimeter (enclosure) using ambient air as a low velocity source of ventilating air through the enclosure. A shroud forces ventilating air to pass over the enclosure from an end open to ambient air at the end of the enclosure opposite its ventilating air inlet end and closed around the inlet end of the enclosure in order to obviate the need for regulating ambient air temperature. Psychrometers for measuring dry- and wet-bulb temperature of ventilating air make it possible to account for the sensible and latent heat additions to the ventilating air. A waste removal system momentarily recirculates high velocity air in a closed circuit through the calorimeter wherein a sudden rise in moisture is detected in the ventilating air from the outlet.

Poppendiek, Heinz F.↗

Effect of Atmospheric Press on Wet Bulb Depression

Our measurements of wet bulb depression at different pressures matched the modeled adiabatic saturation temps reasonably well. At a dry bulb temp of 25 C, the normal wet bulb temp for 30% RH and 100 kPa is approx.15 C, but this dropped to approx.8 C at 10 kPa. The results suggest that psychrometers need direct calibration at the target pressures or that pressure corrected charts are required. For a given vapour pressure deficit, any moist surfaces, including transpiring plant leaves, will be cooler at lower pressures due to the increased evaporation rates.